[Radiofrequency ablation of the atrioventricular accessory pathways. Value of unipolar and bipolar recordings].

Radiofrequency catheter ablation has become the treatment of choice of arrhythmias related to accessory atrioventricular pathways. The reported success rate is well over 90%, irrespective of the localisation of the accessory pathway, and serious complications are rare. A basic principle of the technique is the limitation of the number of applications of radiofrequency energy during a session of ablation and this requires mapping to determine the ideal site using various electrographic parameters. With regards to bipolar recordings, they include: the atrioventricular conduction time, localisation of the ventricular pole of the accessory pathway, recording the accessory pathway potential, the atrial pole of the accessory pathway, and stability of the catheter position. However, the parameters are not readily reproducible and the positive predictive value for successful ablation is low. The use of unipolar electrograms could therefore represent a fundamental step in improving the localisation of accessory pathways and thereby reducing the number of useless applications of radiofrequency energy.

Arrhythmias, Cardiac↗

[Value of unipolar and bipolar recordings in radiofrequency ablation of accessory atrioventricular pathways].

The aim of the study was to compare the value of different modes of endocavitary recordings: unipolar alone, bipolar alone and the association of unipolar and bipolar recordings in radiofrequency ablation of accessory atrioventricular pathways. A retrospective analysis by three independent observers of 135 endocavitary recordings obtained immediately before radiofrequency application in 82 subjects who underwent radiofrequency ablation for symptomatic accessory atrioventricular pathways. In each case, the authors selected the "successful" record which corresponded to the final radiofrequency application and 0.1 or 2 records of "failures". Each initial recording being of 3 types (unipolar, bipolar and association of uni- and bipolar), a total of 390 anonymous and randomised recordings were analysed by the observers who determined whether the appearances indicated successful ablation. Univariate analysis of variants showed a correlation between success with the mode of recording (p = 0.03) and a left lateral position of the accessory pathways. In multivariate analysis, three variables remained correlated with successful ablation: the observer variable (p = 0.001), and two interactions observer - mode (p = 0.005) and observer-stability (p = 0.02). The benefits of the association of unipolar and bipolar recordings with respect to bipolar recording alone, seemed to be important in predicting failure. The results of tests of concordance in the group of failures were confirmatory: concordance between observers was only found between the unipolar mode alone and the association of unipolar and bipolar recordings. The results of this study suggest that the association of unipolar and bipolar endocavitary recordings may reduce the number of unnecessary application of radiofrequency energy by improved identification of recording showing failure.

Adult↗

[Which patients at risk of sudden death after myocardial infarction? Critical study of prognostic factors].

A lot of acquired data concerning the prognostic factors of post-infarction mortality dates from the pre-thrombolysis era. This mortality has considerably decreased since the active management of the acute phase of myocardial infarction. This has made it more complex to evaluate the post-infarction electrical risk and may have reduced the need. However, it is not less true that the assessment of the post-infarction risk necessitates a study of each factor predisposing to severe ventricular arrhythmias and sudden death: myocardial ischaemia, left ventricular dysfunction and electrical instability. The latter parameter may be assessed by non-invasive (ventricular extrasystoles, late ventricular potentials, heart rate variability, the baroreflex and the QT interval) and invasive methods (programmed ventricular stimulation). The association of these results has an excellent negative predictive value, and also improves the positive predictive value which, nevertheless, remains insufficient for expensive prophylactic measures associated with a certain morbidity, for example the implantation of a defibrillator device, to be taken.

Death, Sudden, Cardiac↗

[Atrial electrophysiological study of unexplained ischemic cerebrovascular disorders].

The aim of this study was to search for the presence of atrial vulnerability by programmed atrial stimulation in patients with unexplained ischaemic cerebrovascular strokes and to evaluate the effects of intravenous flecainide acetate on the electrophysiological parameters and on the induction of atrial arrhythmias. Thirty-eight patients (20 men, 18 women) with a mean age of 38.4 +/- 11 years were investigated. Programmed atrial pacing triggered a sustained (> 1 min) atrial arrhythmia with 1 or 2 extrastimuli in 23 of the 38 patients (61%), in these patients, there was a significant shortening of the effective refractory periods (ERP: 193 +/- 23 vs 218 +/- 30 ms; p < 0.02) and of the functional refractory periods (FRP: 228 +/- 25 vs 253 +/- 27 ms; p < 0.01) with lengthening of the A2 auriculogramme (99.7 +/- 22 vs 76.1 +/- 16 ms; p < 0.05). A combined study of the refractory periods and conduction defects provides a means of calculating an index of latent vulnerability which is greatly shortened when an atrial arrhythmia is induced (2 +/- 0.5 cm vs 3 +/- 0.6 cm; p < 0.001). Atrial arrhythmias could not be initiated after intravenous 3 mg/kg of flecainide acetate in 4 subjects (17%) with initially positive atrial stimulation tests. This study confirms the high frequency of atrial vulnerability in patients with unexplained ischaemic cerebrovascular strokes. In their population, the authors observed a low efficacy of flecainide acetate in the prevention of reinduction of atrial arrhythmias. The indication of long-term antiarrhythmic drugs in these patients are questionnable and should be assessed by a prospective long-term multicentre trial.

Adult↗

Factors influencing changes in the signal-averaged electrocardiogram within the first year after a first myocardial infarction.

One hundred twenty-nine patients were prospectively studied after a first myocardial infarction. A first signal-averaged electrocardiogram (SAECG-1) was performed in the acute phase (within 48 hours after onset of symptoms) and a second one (SAECG-2) in the late phase (6 to 18 months after hospital discharge). We studied the influence of nine parameters on the evolution of the signal-averaged electrocardiogram: age, gender, myocardial infarction location, number of diseased coronary vessels, infarct-related coronary artery patency, use of thrombolytic therapy or percutaneous transluminal coronary angioplasty in the acute phase, left ventricular ejection fraction, and recurrence of ischemic events. No follow-up data were available in 15 patients. Of the remaining 114 patients, an ischemic event occurred in 25 (22%). The signal-averaged electrocardiogram remained unchanged in 97 (85%) (remaining normal in 78 and abnormal in 19). It became abnormal in 13 (11.5%) and became normal in 4 (3.5%). In patients with a normal SAECG-1, two factors were associated with the change to an abnormal SAECG-2: (1) an ischemic event occurred in 11 (85%) of 13 patients whose SAECG-2 was abnormal compared with only 13 (17%) of 78 patients whose SAECG-2 remained normal (p < 0.0001), and (2) 100% of patients with an abnormal SAECG-2 had an inferior myocardial infarction compared with 54% of patients with a normal SAECG-2 (p = 0.004).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

[Influence of gender and size on parameters measured by signal-averaged electrocardiography in healthy subjects: preliminary study].

The aim of this study was to determine the influence of electrocardiographic and biomorphometric factors on the parameters measured by signal averaged electrocardiography (SA-ECG) in normal subjects. The study population comprised 40 Caucasian students (20 men, 20 women). The SA-ECG measured 6 parameters: total duration of the averaged QRS, the root mean square of the voltage of the last 40 ms of the QRS (RMS 40) and the length duration of the terminal signal of under 40 microV (LAS), each parameter being measured with a band pass filter of 25 and 40 Hz. The echocardiographic recording included measurement of 12 parameters including left ventricular mass and ventricular volumes. Five morphological parameters were measured, including height, weight and body surface area. The duration of QRS measured with a 25 Hz band pass filter was significantly longer by 9.7 ms in men than in women (102.9 +/- 8.5 ms versus 93.2 +/- 8.1 ms; p < 0.001). Similarly, QRS duration measured with the 40 Hz band pass filter was longer in men by 11.4 ms than in women (102.1 +/- 9.6 ms versus 90.7 +/- 7.5 ms; p < 0.001). Multiple linear regression analyses showed that in both men and women, the duration of the QRS measured with either a 25 or 40 Hz band pass filter was correlated to size: the taller the subject, the longer the QRS duration. A negative correlation was observed between size and RMS 40 measured with both 25 and 40 Hz band pass filters: the taller the subject, the smaller the value of RMS 40.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Value of permanent cardiac pacing in hypertrophic and obstructive cardiomyopathies resistant to medical treatment].

The authors report their experience of long-term dual-chamber pacing in the treatment of hypertrophic and obstructive cardiomyopathy. Between August 1990 and March 1993, 16 patients (8 men, average age 53.5 +/- 18.9 years, range 21 and 79 years) with symptomatic hypertrophic obstructive cardiomyopathy resistant to medical therapy underwent electrophysiological investigation to assess atrioventricular conduction and the effects of temporary atrioventricular pacing on the intraventricular pressure gradient before implantation of a dual-chamber pacing system. The decision to implant was taken if the endocavitary studies showed severe atrioventricular conduction defects and/or if temporary pacing reduced the systolic pressure gradient by more than 30%. Temporary dual-chamber pacing led to a decrease of 48% of the systolic pressure gradient from 78.6 +/- 21.3 to 40.1 +/- 23.6 mmHg (p < 0.0005), a regression observed in 15 of the 16 patients. After an average follow-up period of 18.7 +/- 9.5 months (range 6 and 37 months), all 15 patients who received a dual-chamber pacing system were alive and were clinically improved. The systolic pressure gradient continued to decrease during the follow-up period (24.4 +/- 17.2 mmHg at the 6th month compared with 36.5 +/- 18.6 mmHg at the time of implantation; p = 0.014). The clinical improvement was dependent on careful adjustment of the atrioventricular delay which was programmed at relatively short values (65.6 +/- 14 ms, range 47 and 75 ms) to obtain permanent right ventricular capture. The authors conclude that dual-chamber pacing is an effective means of treating symptomatic hypertrophic obstructive cardiomyopathy resistant to medical therapy, even in the absence of preexisting conduction defects.

Adult↗

[Results, complications and long-term follow-up of percutaneous ablation of atrioventricular conduction. Apropos of 85 cases].

This retrospective study reports the immediate and long-term results of percutaneous ablation of atrioventricular conduction. Between July 1983 and January 1992, 85 consecutive patients (51 men, age 64 +/- 10 years, range 43-84 years) presenting with supraventricular arrhythmias (atrial fibrillation n = 53; atrial flutter n = 50; atrial tachycardia n = 17; junctional tachycardia n = 6) resistant to antiarrhythmic therapy (number of drugs used: 4 +/- 1.3, range 1-6) underwent interruption of atrioventricular conduction by fulguration (n = 65) or radiofrequency energy (n = 13) or by an association of the two methods (n = 7). The 75 pacemakers implanted (10 patients had pacemakers before the procedure) comprised 55 VVIR, 11 VVI, 5 DDD and 4 DDDR units. The immediate results included two sudden deaths at the 4th and 7th day in patients undergoing fulguration and three complications with a favourable outcome (staphylococcal septicaemia, pulmonary embolism and haematoma at the site of implantation of the pacemaker). None of the patients was lost to follow-up and the average follow-up was 31 +/- 18 months (range 2-108 months). During follow-up, 15 patients died and there was a recurrence of symptoms in 11 patients after 1 to 9 months requiring a repeat procedure. In the 68 survivors, the follow-up is now 38 +/- 18 months (range 12-108 months). Sixty one patients have 2nd (2) or 3rd (59) degree atrioventricular block, giving 90% good electrocardiographic results.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Clinical aspects of implantable defibrillators: indication].

The rapidity of technological progress has now made available a device which was only a dream a few years ago, a nearly ideal implantable defibrillator. Despite the persistence of a number of technical and clinical problems, the fourth generation defibrillators are multiprogrammable, with antitachycardia and antibradycardia functions, implantable by the endocavitary approach in most cases thanks to the introduction of biphasic shocks, fitted with constantly improving systems of telemetry, and are progressively smaller in size. The selection of a defibrillator device requires consideration of the patient's needs and the technical characteristics of the defibrillator. Apart from special situations in which the indications of the implantable defibrillator are generally accepted, it is only possible in the absence of results of prospective clinical trials, to use data accumulated on the place of defibrillation compared with other forms of management of severe ventricular arrhythmias. As there is a wide choice of treatment of these ventricular arrhythmias, the role of each must be defined for each individual patient. With regards to the implantable defibrillator, it is essential to take into consideration a number of clinical and paraclinical factors such as the clinical preservation of the arrhythmia, the underlying cardiac disease, left ventricular function and the type of arrhythmia induced by programmed ventricular stimulation.

Arrhythmias, Cardiac↗

[Left-sided His bundle ablation after failure of right-sided approach: technique and initial results].

Although interruption of atrioventricular conduction has been widely used over the last decade in patients with supraventricular arrhythmias and rapid conduction resistant to antiarrhythmic therapy, the incidence of atrioventricular block obtained by delivering the energy at the tricuspid ring ranges from 45 to 92%. Failure of this technique is usually related to the inhability to record endocavitary electrogrammes compatible with probable success by the right-sided approach. The authors report four cases of interruption of atrioventricular conduction in 4 men (average age 61.5 +/- 10 years) by the retrograde arterial catheterisation after one or more (1 to 3) failures by the right-sided approach. After arterial puncture, the ablation catheter is positioned against the interventricular septum below the aortic cusps to record the His bundle electrogram. His bundle ablation was obtained after an average of 2 radio frequency energy applications (range 1 to 3). At the time of effective application, the average amplitude of the endocavitary electrogram was as follows: auriculogram 0.09 mV (range 0.05 to 0.2 mV), His bundle electrogram 0.19 mV (0.15-0.22 mV), ventriculogram 1.36 mV (1.0 to 1.7 mV). No complications were observed. After an average follow-up of 4 months, the 4 patients were still in complete atrioventricular block. This preliminary series shows that left-sided interruption of atrioventricular conduction is effective and safe. It may be proposed after failure of a right-sided attempt.

Aged↗

The 12-lead electrocardiogram in midseptal, anteroseptal, posteroseptal and right free wall accessory pathways.

The 12-lead electrocardiograms of 50 patients with 1 anterogradely conducting accessory pathway were analyzed to obtain characteristics of electrocardiographic findings in the midseptal, anteroseptal, true posteroseptal and right free wall accessory pathway locations. Locations were confirmed by surgery (33 patients) or radiofrequency catheter ablation (17 patients). This study analyzed (1) QRS in the frontal plane, (2) delta wave axis in the frontal plane, (3) the angle between QRS and delta wave axes, (4) the R/S ratio in lead III, (5) negativity of delta wave in inferior leads, and (6) the R/S ratio in precordial leads.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Improvement in left ventricular function by ablation of atrioventricular nodal conduction in selected patients with lone atrial fibrillation.

Left ventricular (LV) function was studied in 30 patients with lone atrial fibrillation (AF) (paroxysmal [n = 27] and persistent [n = 3]) before and after ablation of atrioventricular conduction. In all patients, drug treatment did not control ventricular rate during AF or prevent recurrences of the arrhythmia, or both. LV ejection fraction, and LV end-systolic and end-diastolic, and left atrial dimensions were measured by echocardiography before (mean 7 +/- 10 months, range < 1 to 37) and after (14 +/- 20 months, < 1 to 77) ablation. Before ablation, LV ejection fraction was < or = 50% in 12 patients (group I) and > 50% in 18 (group II). After ablation, LV ejection fraction increased significantly in group I from 43 +/- 8% to 54 +/- 7% (p < 0.0001). There were also significant decreases in LV-end systolic and end-diastolic, and left atrial dimensions. No changes in these parameters were observed in group II. Groups I and II had a significant difference in the duration of AF (group I: mean 11 years, range 8 to 28; and group II: 5 years, 2 to 14) (p < 0.05). No difference was present in age, sex, New York Heart Association functional class for dyspnea, or type of ablation procedure. Thus, some patients with lone AF may show deterioration of LV function, which appears to be related to the duration of the arrhythmia; in these cases, LV function may improve significantly after ventricular rate control is accomplished by ablation of atrioventricular conduction.

Adult↗

Value of the 12-lead electrocardiogram in arrhythmogenic right ventricular dysplasia, and absence of correlation with echocardiographic findings.

The 12-lead electrocardiogram during sinus rhythm was studied in 20 patients with arrhythmogenic right ventricular (RV) dysplasia with symptomatic ventricular tachycardia. Findings were analyzed, together with echocardiographic evaluation of site, extent and progression of RV wall abnormalities. Electrocardiographic abnormalities were found in 90% of patients. No correlation was found between abnormalities on the initial 12-lead electrocardiogram, and the echocardiographic extent and location of RV involvement. Over time, echocardiographic progression of the disease was observed; RV size increased in 6 of 7 patients from 34 +/- 3 to 39 +/- 3 mm (p = 0.01), and there was progression in the extent of RV wall motion abnormalities in 4 of 7 patients. Analysis of serial electrocardiographic recordings did not reveal changes indicative of progression of the disease during follow-up of 71 +/- 48 months. It is concluded that electrocardiographic abnormalities suggesting arrhythmogenic RV dysplasia are present in 90% of symptomatic patients on the first electrocardiogram recorded during sinus rhythm. However, serial electrocardiographic recordings in these patients do not provide information regarding anatomic progression of the disease.

Adolescent↗

Effects on the signal-averaged electrocardiogram of opening the coronary artery by thrombolytic therapy or percutaneous transluminal coronary angioplasty during acute myocardial infarction.

One hundred twenty-nine patients were retrospectively analyzed and divided into 3 groups according to (1) the presence of a patent artery obtained either spontaneously or after thrombolytic therapy but without percutaneous transluminal coronary angioplasty (PTCA) (group I, n = 83), (2) the presence of a patent artery after opening by PTCA (group II, n = 29), or (3) absence of reperfusion despite thrombolytic therapy or PTCA (group III, n = 17). Thrombolytic therapy was given within 4 hours after onset of symptoms (mean 2.5 +/- 1.0 hours) and PTCA was performed within 24 hours after the onset of symptoms (mean 6 +/- 6 hours). Signal averaging was performed within 24 hours after cardiac catheterization. An abnormal signal-averaged electrocardiogram was present in 10 of 83 (12%) group I, 9 of 29 (31%) group II and 7 of 17 (41%) group III patients (p < 0.05 group I vs II, p < 0.01 group I vs III, no statistical difference group II vs III). Therefore, in contrast to reperfusion by thrombolytic therapy the incidence of abnormalities on the signal-averaged electrocardiogram early after myocardial infarction is not reduced by an early opening of the culprit vessel by PTCA.

Angioplasty, Balloon, Coronary↗

Echocardiographic wall motion abnormalities and the signal averaged electrocardiogram in the acute phase of a first myocardial infarction.

We studied the relationship between wall motion abnormalities determined by echocardiography and the signal-averaged electrocardiogram in 82 consecutive patients during the acute phase of a first myocardial infarction. An abnormal signal-averaged electrocardiogram was defined as the presence of two of the following criteria: a QRS duration > or = 114 ms, a root mean square voltage (RMS) of the last 40 ms < or = 25 microV and an amplitude signal lower than 40 microV lasting > or = 39 ms. The left ventricle was divided into 13 segments and the contraction pattern divided into akinesia alone (including dyskinesia) (group A), hypokinesia alone (group B) and both hypokinesia and akinesia (group C). An abnormal signal-averaged electrocardiogram was found in 14/82 patients (17%) and was correlated with the persistence of occlusion of the infarct-related vessel (32% vs 9%, P < 0.02). In patients with a patent vessel, the incidence of an abnormal signal-averaged electrocardiogram was 14% in group A, 9% in group B and 0% in group C (NS). In patients with an occluded vessel an abnormal signal-averaged electrocardiogram was found in 10% of group A patients, in 36% in group B patients and in 75% of group C patients (P = 0.05). Our study suggests that the presence of hypokinetic areas during the acute phase of a first myocardial infarction and an abnormal signal-averaged electrocardiogram indicate an occluded infarct-related vessel.

Aged↗

[Correlation between parameters measured by high amplification ECG and results of programmed ventricular stimulation after myocardial infarct].

The presence of late ventricular potentials and the induction of sustained ventricular tachycardia (SVT) by programmed ventricular stimulation (PVS) after myocardial infarction are markers of the risk of serious ventricular arrhythmias. The authors studied the value of signal averaged electrocardiography (SAECG) compared with induction of SVT by PVS in 118 consecutive patients 4 to 8 weeks after myocardial infarction. In addition to this study population, a control group of 22 patients with spontaneous SVT after myocardial infarction was also considered. Three parameters were measured after averaging 200 QRS complexes: the duration of the filtered QRS complex (QRSd), the duration of signals not exceeding 40 microV (LAS) and the root mean square of the voltage of the last 40 milliseconds (RMS). Abnormal values were defined as: QRSd > or = 120 ms, LAS > or = 39 ms, RMS < or = 20 microV. Patients in the study population were subdivided into 3 groups: Group I (n = 17) inducible SVT; Group II (n = 72) no inducible arrhythmias; Group III (n = 29) induction of sustained ventricular flutter or primary ventricular fibrillation requiring immediate cardioversion. The results showed a good correlation between SAECG and induction of SVT. The sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were as follows: 1) QRSd > 120 ms: Se = 82%, Sp = 80%, PPV = 41%, NPV = 96%; 2) LAS > 39 ms: Se = 59%, Sp = 85%, PPV = 38%, NPV = 92%; 3) RMS < 20 V: Se = 59%, Sp = 88%, PPV = 43%, NPV = 93%.(ABSTRACT TRUNCATED AT 250 WORDS)

Action Potentials↗

[Implantable defibrillator using epicardial and endocardial leads. Results of 36 implantations].

The authors report their experience of implantable defibrillators over a 5 year period. Between February 1988 and July 1992, 36 patients (25 men, 11 women, average age 51 +/- 11 years, range 18 +/- 71 years) underwent implantation of an automatic defibrillator with epicardial (n = 13, Group I) or endocardial leads (n = 23, Group II) without patch electrodes (n = 7), with subcutaneous patch electrodes (n = 12) or epicardial patch electrodes (n = 4). Three serious early complications were observed: 2 cardiogenic shocks in Group I, one of which died on Day 1 and one case of infection which required explanation of the defibrillator on Day 23 in Group II. Late complications in Group I included one case of disactivation of the defibrillator, 2 losses of output, one of which required replacement of the defibrillator and 2 increases of threshold treated by implantation of an endocardial lead. In Group II, 2 patients had inappropriate shocks due to overdetection (n = 1) and double counting (n = 1). During an average follow-up period of 28.5 +/- 9 months in group I and 13 +/- 6 months in Group II, 4 patients died, 2 from sudden death. Ninety seven shocks were delivered in 19 patients (56%), 5.1 shocks per patient. In the 17 patients with an antitachycardia function, 14 (82%) developed 947 episodes of VT treated successfully by antitachycardia pacing in 917 cases. This retrospective study confirms the efficacy of implantable defibrillators in the treatment of malignant ventricular arrhythmias. The efficacy of endocardial and epicardial leads seems to be the same but there seems to be a lower immediate mortality and morbidity with the endocardial system.

Adult↗