Search PubMed⌕ Search

Biomedical subjects

C X Yu

Publications and source records attributed to C X Yu.

At least 19 recordsLinked to original sources

Toroidal symmetry of the geodesic acoustic mode zonal flow in a tokamak plasma.

The toroidal symmetry of the geodesic acoustic mode (GAM) zonal flows is identified with toroidally distributed three step Langmuir probes at the edge of the HuanLiuqi-2A (commonly referred to as HL-2A) tokamak plasmas for the first time. High coherence of both the GAM and the ambient turbulence for the toroidally displaced measurements along a magnetic field line is observed, in contrast with the high coherence of the GAM but low coherence of the ambient turbulence when the toroidally displaced measurements are not along the same field line. The radial and poloidal features of the flows are also simultaneously determined. The nonlinear three wave coupling between the high frequency turbulent fluctuations and the flows is demonstrated to be a plausible formation mechanism of the flows.

Journal Article↗

An examination of the number of required apertures for step-and-shoot IMRT.

We have examined the degree to which step-and-shoot IMRT treatment plans can be simplified (using a small number of apertures) without sacrificing the dosimetric quality of the plans. A key element of this study was the use of direct aperture optimization (DAO), an inverse planning technique where all of the multi-leaf collimator constraints are incorporated into the optimization. For seven cases (1 phantom, 1 prostate, 3 head-and-neck and 2 lung), DAO was used to perform a series of optimizations where the number of apertures per beam direction varied from 1 to 15. In this work, we attempt to provide general guidelines for how many apertures per beam direction are sufficient for various clinical cases using DAO. Analysis of the optimized treatment plans reveals that for most cases, only modest improvements in the objective function and the corresponding DVHs are seen beyond 5 apertures per beam direction. However, for more complex cases, some dosimetric gain can be achieved by increasing the number of apertures per beam direction beyond 5. Even in these cases, however, only modest improvements are observed beyond 9 apertures per beam direction. In our clinical experience, 38 out of the first 40 patients treated using IMRT plans produced using DAO were treated with 9 or fewer apertures per beam direction. The results indicate that many step-and-shoot IMRT treatment plans delivered today are more complex than necessary and can be simplified without sacrificing plan quality.

Algorithms↗

Thomson scattering measurements of heat flux from ion-acoustic waves in laser-produced aluminum plasmas.

Thomson scattering (TS) measurements are performed at different locations in a laser-produced aluminum plasma. Variations of the separation, wavelength shift, and asymmetric distribution of the two ion-acoustic waves are investigated from their spectral-time-resolved TS images. Detailed information on the space-time evolution of the plasma parameters is obtained. Electron distribution and variation of the heat flux in the plasma are also obtained for a steep temperature gradient.

Journal Article↗

Inverse planning for intensity-modulated arc therapy using direct aperture optimization.

Intensity-modulated arc therapy (IMAT) is a radiation therapy delivery technique that combines gantry rotation with dynamic multi-leaf collimation (MLC). With IMAT, the benefits of rotational IMRT can be realized using a conventional linear accelerator and a conventional MLC. Thus far, the advantages of IMAT have gone largely unrealized due to the lack of robust automated planning tools capable of producing efficient IMAT treatment plans. This work describes an inverse treatment planning algorithm, called 'direct aperture optimization' (DAO) that can be used to generate inverse treatment plans for IMAT. In contrast to traditional inverse planning techniques where the relative weights of a series of pencil beams are optimized, DAO optimizes the leaf positions and weights of the apertures in the plan. This technique allows any delivery constraints to be enforced during the optimization, eliminating the need for a leaf-sequencing step. It is this feature that enables DAO to easily create inverse plans for IMAT. To illustrate the feasibility of DAO applied to IMAT, several cases are presented, including a cylindrical phantom, a head and neck patient and a prostate patient.

Algorithms↗

A quality assurance method for analyzing and verifying intensity modulated fields.

A quality assurance method is developed for measuring, verifying and analyzing intensity modulated radiation fields. It is applicable for rotational and fixed-beam intensity modulated radiation therapy (IMRT) treatments. A gantry-mount device was constructed to measure the transmission dose of an IMRT field using radiographic films. A double-exposure technique with optimal kernel estimate method was developed to minimize the errors from measurements. A chi2 confidence level test method was developed to detect the discrepancies between measured and prescribed IMRT fluence distributions. Our method was tested for rotational and fixed-beam IMRT treatment verifications. The method was found insensitive to the hardware-related parameters for rotational and fixed-beam IMRT deliveries. The chi2 confidence level test was found to be more sensitive than linear correlation method in detecting relative small errors for cases with a few segments or narrow regions of interest. In conclusion, we demonstrated a quantitative method for verifying and analyzing IMRT treatment deliveries.

Models, Statistical↗

Optimized intensity-modulated arc therapy for prostate cancer treatment.

We recently implemented intensity-modulated arc therapy (IMAT) at our institution. In this study, we evaluate the dosimetric merits of the application of this technique to the treatment of prostate cancer. Each IMAT treatment plan incorporated bilateral overlapping arcs. The dose from each beam segment was computed using the three-dimensional dose model of a clinical treatment planning system (Render Plan 3.5, Precision Therapy). The weights assigned to the individual arc segments were optimized using a gradient search method. For 12 patients, comparisons were made between the IMAT treatment plans and corresponding plans using fixed cone-beam intensity-modulated radiotherapy (IMRT) from a commercial inverse planning system (CORVUS, NOMOS Corp.). We found that the optimized IMAT treatments produced similar dose distributions to the IMRT deliveries. Compared with the IMRT treatments, the IMAT treatments produced slightly less target dose homogeneity with consistently greater sparing of the rectum in regions of lower dose. The trade-off between target dose conformity and rectum sparing can be adjusted in both optimization procedures. Because the total beam-on time for IMAT delivery is 1 to 2 minutes with approximately 5-6 minutes of patient setup time, the delivery efficiency of the IMAT treatment was significantly better than the multiple-beam IMRT treatment.

Humans↗

Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing.

The frequent blocking of the irradiated volume in intensity modulated radiation therapy (IMRT) makes the head-scatter fraction of the incident photon fluence more significant than that in conventional therapy with open fields. On the other hand. certain collimator configurations block scatter photons directed to a given observation point while allowing primary photons to be transmitted. The 'anomalous blocking' makes the primary field a poor indicator of the scatter fluence. Since large MU-to-cGy ratios in IMRT can magnify head-scatter uncertainties, it becomes necessary to accurately model both the effective scatter source and the collimator structure that limits the scatter reaching the irradiated volume. First we obtain a dual-source model, using a Taylor series expansion to derive the effective scatter source distribution from the data measured for the Elekta SL20 linac equipped with a multi-leaf collimator (MLC). Then, using a raytracing algorithm, we calculate the transmission of scatter rays from the effective scatter source plane to points in the patient plane. The method can account for the anomalous blocking of scatter by the MLC leaves and the backup diaphragms. For a variety of collimator settings tested, the calculations agree with measurements to an accuracy of 0.002psi10 x 10, where psi10 x 10 is the total (primary + scatter) photon fluence of an open 10 x 10 cm2 field for the same MU delivered. Although the significance of collimator structure in IMRT depends strongly on fields shapes employed for the delivery, potential cumulative errors on the order of a few per cent can be avoided in fluence calculations if the proposed method is used.

Algorithms↗

Alteration of orphanin FQ immunoreactivity and ppOFQ mRNA by combination of melatonin with electroacupuncture.

The aim of the present study was to observe the alternation of central orphanin FQ (OFQ, also known as nociceptin) system while electroacupuncture (EA) combined with melatonin (MEL). The experiments were carried out to investigate the changes of OFQ-like immunoreactivity and prepro-orphanin FQ (ppOFQ) mRNA in some certain nuclei of the rat brain. Using immunohistochemical technique we found that the level of OFQ-like immunoreactivity was increased significantly in some pain-modulation-related nuclei, such as ventromedial hypothalamic nucleus, raphe magnus nucleus, dorsal raphe nucleus and periaqueductal gray (PAG) after intraperitoneal (i.p.) injection of MEL 60 mg/kg, and it was further enhanced while MEL combined with EA. By using in situ hybridization, we found that ppOFQ mRNA expression was decreased in the same nuclei after the administration of MEL, and further decreased following the combination of EA and MEL. The results suggested that attenuating the release and synthesis of OFQ in the brain is one of the mechanisms that melatonin promotes acupuncture analgesia.

Acupuncture Analgesia↗

[Screening the mimic antigen epitopes of triosephosphate isomerase of Schistosoma japonicum Chinese strain (Sjc-Tpi) with random phage peptide library].

OBJECTIVE: To screen the mimic antigen epitopes of the triose phosphate isomerase of Schistosoma japonicum Chinese strain (SjC-TPI) and investigate their immunogenicity. METHODS: The random phage peptide library (PH.D.-12) was screened with the purified antibody(IgG) against SjC-TPI to get the positive phage which contained the mimic antigen epitopes of SjC-TPI, and the immuno-characterization of the mimic antigen epitopes were investigated. RESULTS: Two mimic antigen epitopes (M1, M2) of SjC-TPI were obtained. The immuno-sera of mice (Kunming strain) against the positive phages could recognize both the SjC-TPI and the protein of the positive phages. The DNA sequencing data showed no homology between the sequences of the deduced amino acid of the two mimic antigen peptides and the amino acid of SjC-TPI. CONCLUSION: The two mimic antigen epitopes of SjC-TPI obtained are imitative epitopes of the configuration antigen of SjC-TPI.

Animals↗

[Protective immunity induced by 23 kDa membrane protein DNA vaccine of Schistosoma japonicum Chinese strain in mice].

OBJECTIVE: To develop 23 kDa membrane protein DNA vaccine of Schistosoma japonicum Chinese strain and test its protective efficacy in infected C57BL/6 mice. METHODS: The full length cDNA encoding SjC23 amplified from pUC19-SjC23 subcloned into pcDNA3.1. 48 female mice were divided into three groups: A, B and C. Group A (control group) was each immunized i.m. with 100 micrograms of pcDNA3.1; group B (SjC23 group) was each immunized i.m. with 100 micrograms of pcDNA3.1-SjC23; group C (SjC23 + IL-12) was each immunized i.m. with a mixture of 100 micrograms of pcDNA3.1-SjC23, 100 micrograms of pcDNA3.1-p35 and 100 micrograms of pcDNA-p40, followed by two boosts of the same DNA once every two weeks. All the mice were challenged with 45 cercariae at week 8, killed and perfused for worms at week 14. The expression of SjC23 and p35, p40 in muscle tissue was determined by immuno-histochemical method. By the culture of spleen cells, the production of IL-2, IL-4, IL-10 and IFN-gamma after the stimulation of rSjC23-HD was determined two weeks before and after challenge. Anti-SjC23 antibodies were tested by Western blotting. RESULTS: SjC23 and p35, p40 were all expressed on the membrane and in the plasma of muscle cells of the infected mice. Significant increase of IL-2 and IFN-gamma in SjC23 and SjC23 + IL-12 groups was observed before and after challenge. Western blotting showed that after the third immunization (before challenge) 8 out of 10 sera from SjC23 group and 9 out of 10 sera from SjC23 + IL-12 group were positive. The worm reduction rate in SjC23 group and SjC23 + IL-12 group was 26.9% and 35.4%, respectively; the number of eggs in liver tissue was reduced by 22.2% and 28.4%, respectively. CONCLUSION: pcDNA3.1-SjC23 DNA vaccine could induce partial protection against Schistosoma japonicum in C57BL/6 mice.

Animals↗

[Changes of cerebral beta-endorphin in rats treated with combination therapy of melatonin and electroacupuncture].

OBJECTIVE: To explore the strengthening of acupuncture analgesic mechanism on the level of beta-endorphin and proopimelanocortin mRNA expression in the arcuate nucleus of hypothalamus in rats following electroacupuncture (EA) combined with melatonin (MEL). METHODS: Integrated optical density (IOD) was measured by ABC immuno-histochemical and in situ hybridization technique with computerized image processing. The rat's brain was coronally sectioned after combination of EA and MEL. RESULTS: IOD of beta-endorphin-like immunopositive substance in rat's brain was lowered significantly, which was measured after MEL (60 mg/kg) was injected intraperitoneally and followed by EA 30 min later for 30 min, and the IOD of cerebral POMC mRNA positive substance increased significantly 10 hrs later. CONCLUSION: The mechanism of MEL in enhancing EA analgesic effect might be related with the release and synthesis of beta-endorphin.

Acupuncture Analgesia↗

[Effect of melatonin on release of beta-endorphin, norepinephrine and 5-hydroxytryptamine in rat brain].

AIM: In order to explore the mechanism of action of melatonin to induce analgesia, the present study was undertaken to observe the effects of melatonin on the release of beta-endorphin (beta-Ep), norepinephrine (NE) and 5-hydroxytryptamine in rat brain. METHODS: With the measurement of pain threshold, push-pull perfusion technique and radioimmunoassay were used to determine the immunoreactive beta-Ep content in the perfusate from the third ventricle of rat brain. The contents of 3-methoxy-4-hydroxyphenyl glycol (MHPG) and 5-hydroxyindole acetic acid in the microdialysate from rat brain were measured by techniques of in vivo microdialysis and high performance liquid chromatography with electrochemical detection. RESULTS: The immunoreactive beta-Ep content in the perfusate from the third ventricle of rat brain was increased significantly (P < 0.05) following an intraperitoneal administration of 110 mg.kg-1 of melatonin, with the increase of pain threshold. The MHPG and 5-HIAA contents in the microdialysate from the periaqueductal gray (PAG) or the hypothalamus were not changed after the administration of melatonin. CONCLUSION: Melatonin may promote the release of beta-Ep in brain, which may be one of the mechanisms of the analgesic action of melatonin. The analgesic action of melatonin may not be related to the release of NE and 5-HT in the PAG or the hypothalamus.

Analgesics↗

The analgesic effects of peripheral and central administration of melatonin in rats.

To explore the site and mechanism of the analgesic action of melatonin, the present study was designed to evaluate the analgesic effects of intraperitoneal (i.p.) and intracerebroventricular (i.c.v. ) administration of melatonin, and to investigate the effect of i.c. v. naloxone on the analgesic effect induced by i.p. melatonin in rats. Antinociception was determined by tail-flick latency to hot water at 50 degrees C. On i.p. administration, melatonin (30, 60 and 120 mg/kg) produced the antinociceptive effect in a dose-dependent manner, with an A(50) of 72.8 mg/kg. Administered i.c.v., melatonin (0.25, 0.5 and 1 mg/kg) also resulted in dose-dependent antinociception, with an A(50) of only 0.693 mg/kg. Injected i.c.v. to rats, 10 microg of naloxone antagonized significantly the antinociceptive effect induced by i.p. melatonin. It is concluded that melatonin has an analgesic effect in rats and the central nervous system (CNS) may be the primary site for melatonin to elicit the response, and the effect of melatonin is related to the central opioid system.

Analgesics↗

Selective MT(2) melatonin receptor antagonist blocks melatonin-induced antinociception in rats.

The present study was undertaken to assess the effects of intracerebroventricular (i.c.v.) luzindole (a selective MT(2) melatonin receptor antagonist) and prazosin (a selective MT(3) melatonin receptor antagonist) on melatonin-induced antinociception, so as to clarify which of melatonin receptor subtypes within the central nervous system (CNS) was mediating antinociception. The pain threshold of rats was measured by the hot water (50 degrees C) tail-flick test. It was found that intraperitoneal (i.p.) melatonin (30, 60, 120 mg/kg) resulted in a dose-dependent antinociception. Luzindole (50, 100 microgram) administered intracerebroventricularly antagonized significantly the antinociceptive effect induced by i.p. melatonin (120 mg/kg), whereas prazosin (50 microgram) did not. Neither luzindole (100 microgram, i.c.v.) nor prazosin (50 microgram, i.c.v.) affected the nociceptive threshold when given alone. The results suggest that melatonin-induced antinociception is mediated through the MT(2) melatonin receptor subtype within the CNS.

Analgesics↗

An efficient method of measuring the 4 mm helmet output factor for the Gamma knife.

It is essential to have accurate measurements of the 4 mm helmet output factor in the treatment of trigeminal neuralgia patients using the Gamma Knife. Because of the small collimator size and the sharp dose gradient at the beam focus, this measurement is generally tedious and difficult. We have developed an efficient method of measuring the 4 mm helmet output factor using regular radiographic films. The helmet output factor was measured by exposing a single Kodak XV film in the standard Leksell spherical phantom using the 18 mm helmet with 30-40 of its plug collimators replaced by the 4 mm plug collimators. The 4 mm helmet output factor was measured to be 0.876 +/- 0.009. This is in excellent agreement with our EGS4 Monte Carlo simulated value of 0.876 +/- 0.005. This helmet output factor value also agrees with more tedious TLD, diode and radiochromic film measurements that were each obtained using two separate measurements with the 18 mm helmet and the 4 mm helmet respectively. The 4 mm helmet output factor measured by the diode was 0.884 +/- 0.016, and the TLD measurement was 0.890 +/- 0.020. The radiochromic film measured value was 0.870 +/- 0.018. Because a single-exposure measurement was performed instead of a double exposure measurement, most of the systematic errors that appeared in the double-exposure measurements due to experimental setup variations were cancelled out. Consequently, the 4 mm helmet output factor is more precisely determined by the single-exposure approach. Therefore, routine measurement and quality assurance of the 4 mm helmet output factor of the Gamma Knife could be efficiently carried out using the proposed single-exposure technique.

Film Dosimetry↗

Evaluation of EGS4/PRESTA multiple-scattering algorithms for 90Sr/90Y intravascular brachytherapy dosimetry.

The purpose of this work is to evaluate the EGS4/PRESTA electron multiple-scattering (MS) algorithms for dose calculation in intravascular brachytherapy (IVBT) using a 90Sr/90Y source. The small source size and the small volume of interest in IVBT require very fine spatial resolution, which may break down the constraints of Molière's MS theory as implemented in EGS4. The theory is accurate only when the electron step sizes are large enough to allow the number of collisions omega0 to be much greater than e = 2.7183. When step sizes are too small to allow at least 2.7183 collisions, as may be necessitated by the fine geometry, the algorithm may switch off MS, producing dosimetric artefacts. This study showed that switching off MS could produce a dose deviation of up to 6% when the half-thickness (d/2) of the dose scoring region is comparable with the Moliere minimum step size (t(min) = 2.7183). The effect of switching off MS is negligible if d/2 >> t(min) For the case of omega0 > e, if the electron step sizes are chosen to allow five to 40 collisions, with increasing step size, the doses surrounding the source increase and the error decreases. On the other hand, when larger step sizes are chosen, the dose calculation voxel size must also be increased in order for the calculations to converge. A good compromise between accuracy and applicability for IVBT simulation can be made, if the thickness of the scoring region is 0.1 mm and the electron step sizes are in the range allowing 10 to 30 collisions.

Algorithms↗

Effect of melatonin on pro-opiomelanocortin mRNA expression in arcuate nucleus of rat hypothalamus.

AIM: To observe altered expression of pro-opiomelanocortin (POMC) mRNA localized in neurons in the arcuate nucleus of rat hypothalamus following exogenous administration of melatonin. METHODS: The experimental animals were divided into two groups injected i.p. with melatonin 90 mg.kg-1 and vehicle at 12 h interval (9:00 am and 9:00 pm). Twelve hours after the last injection, the rat brains were processed for coronal sections and nonradioactive in situ hybridization histochemistry technic was used. The integral optical density (IOD) and mean optical density (OD) of the stained brain sections were measured using the computer-assisted image processing technique. RESULTS: The POMC mRNA expression in the arcuate nucleus showed obvious enhancement in the brain sections of rats treated with melatonin. The IOD and OD values in the hypothalamic arcuate nucleus area were increased significantly (P < 0.01, P < 0.05 respectively) with melatonin treatment. CONCLUSION: Melatonin may enhance the POMC mRNA expression in the arcuate nucleus of rat hypothalamus.

Animals↗

[Melatonin influences the release of endogenous opioid peptides in rat periaqueductal gray].

The present study was undertaken to explore central mechanisms underlying the analgesic effect of melatonin. Push-pull perfusion technique and radioimmunoassay were used to observe the changes in the contents of beta-endorphin (beta-Ep) and leucine-enkephalin (L-EK) in the perfusate from the rat periaqueductal gray (PAG) after administration of melatonin. 30 50 min after an intraperitoneal injection of melatonin (110 mg/kg), the beta-Ep content in the perfusate was increased significantly, while the L-EK content was not changed. Pain threshold was measured using the warm water tail-flick test during the push-pull perfusion of the PAG. It was found that the rat pain threshold was increased significantly 40 min after the intraperitoneal injection of melatonin (110 mg/kg). The results suggest that melatonin may promote the release of beta-Ep in the PAG, which may be one of the mechanisms of the analgesic effect of melatonin.

Analgesics, Opioid↗