Search PubMed⌕ Search

Biomedical subjects

C Wakeley

Publications and source records attributed to C Wakeley.

At least 19 recordsLinked to original sources

Dual-energy X-ray absorptiometry applied to the assessment of tibial subchondral bone mineral density in osteoarthritis of the knee.

OBJECTIVE: Plain X-ray is an imprecise tool for monitoring the subchondral bony changes associated with the development of knee osteoarthritis (OA). Our objective was to develop and validate a technique for assessing tibial subchondral bone density (BMD) in knee OA using dual energy X-ray absorptiometry (DXA). DESIGN: Patients with OA of at least one knee underwent DXA scanning of both knees. Regions of interest (ROI) were placed in the lateral and medial compartments of tibial subchondral bone. Weight-bearing plain X-rays and Te (99m) scintiscans of both knees were obtained and scored. RESULTS: One hundred and twelve patients (223 knees) underwent DXA and radiography. Intra-observer CV% was 2.4% and 1.0% for the medial and lateral ROI respectively. Definite OA (Kellgren and Lawrence Grade 2, 3 or 4) was correlated with age-related preservation of subchondral BMD compared to radiographically normal knees. Raised BMD was also associated with subchondral sclerosis, and positive scintigraphy. CONCLUSION: DXA may provide a safe, rapid and reliable means of assessing knee OA. Cross-sectional age-related subchondral tibial BMD loss is attenuated by knee OA.

Absorptiometry, Photon↗

Reconstruction of the lateral patellar retinaculum following lateral release: a case report.

The recognition and treatment of iatrogenic medial subluxation of the patella following lateral retinacular release may be difficult. The diagnosis even by magnetic resonance imaging may be difficult. The use of a medial patellar stabilising brace may be helpful in the diagnosis, alleviating symptoms in the short term and to gain the confidence of the patient. A technique of direct repair that was used successfully is described in a case report.

Adult↗

Error in radiology.

The level of error in radiology has been tabulated from articles on error and on "double reporting" or "double reading". The level of error varies depending on the radiological investigation, but the range is 2-20% for clinically significant or major error. The greatest reduction in error rates will come from changes in systems.

Magnetic Resonance Imaging↗

The STIR sequence MRI in the assessment of extraocular muscles in thyroid eye disease.

Nineteen patients with thyroid eye disease were examined with magnetic resonance imaging using the Short Tau Inversion Recovery (STIR) sequence and compared with normal controls. The Signal Intensity Ratio (SIR) of each of the four recti was obtained by comparison with the signal intensity of the adjacent temporalis muscle. The SIR was compared with disease activity assessed using Werner's grading system, a clinical inflammatory score, and the range of extraocular movements. Results show that a high SIR is associated with a high index of disease activity. This technique is likely to prove useful in assessing disease activity and planning the management of thyroid eye disease, particularly with respect to immunosuppression.

Adult↗

The value of the short tau inversion recovery sequence in magnetic resonance imaging of thyroid eye disease.

22 patients with thyroid eye disease were examined with magnetic resonance imaging (MRI) and the results compared with 10 controls. Imaging was performed on a 1.0 T scanner using a head coil. All patients were examined using both T1W and short tau inversion recovery (STIR) sequences. The relative signal intensity (SI) of individual extraocular muscles were quantified by comparison with SI from the adjacent temporalis muscle to give a signal intensity ratio (SIR). The results were compared with clinical disease activity assessed by the Werner grading system. Visual evaluation of muscle size and calculated SIRs showed an increase when compared to normals in 15 of the 22 patients. This difference was significant in patients with high grade (4-6) clinical disease. The known histological changes in this disease suggest that this increase in signal is caused by oedema secondary to acute inflammation. STIR sequences suppress the retro-orbital fat and thus enhance these changes both in the muscles and in the fat itself. The MR findings suggest that the STIR sequence can be used to predict those patients that will respond to anti-inflammatory treatment.

Adult↗

Gall-stone disease.

Explore the source record for details and available documents.

Cholecystography↗

Whitlows.

Explore the source record for details and available documents.

Fingers↗