Case report: Multicentric carpal/tarsal osteolysis: imaging review and 25-year follow-up.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C W Thomas.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Considerable research suggests that social influences-based drug abuse prevention programming has produced the most consistently successful preventive effects. However, a common criticism of this literature is that most prevention intervention studies rely solely on self-reported substance use. The purpose of this study was to assess the effects of normative education, arguably the most successful component of social influence based prevention programs, on alcohol and cigarette consumption using both self- and reciprocal best friend reports of substance use. Analyses of subsamples of data from 11,995 students participating in the Adolescent Alcohol Prevention Trial revealed that normative education significantly delayed the onset of alcohol use across the eighth, ninth, and tenth grades among public school students. A similar but somewhat less robust pattern was found for cigarette use. These results suggest that self-report bias does not account for previous findings and demonstrate rather convincingly that normative education is an effective drug prevention strategy for public school settings.
The Centers for Disease Control and Prevention (CDC) funds provided to state, local, and territorial health departments for HIV-prevention activities are prioritized with the substantial involvement of HIV-prevention community planning groups (CPGs). This article examines whether or not these funds (more than $261 million in fiscal year 1998) are allocated in a way that mirrors the HIV/AIDS epidemic in terms of race/ethnicity. AIDS prevalence data were used to reflect disease burden, and were compared to budget data submitted by health departments to the CDC. The budget data report expenditures by race/ethnicity for two major types of activities: (1) health education and risk reduction (more than $104 million); and (2) counseling, testing, referral, and partner notification (more than $91 million). The rank order correlation between funding and AIDS prevalence data for the five specific racial/ethnic categories was .900 (n = 5, p < .05) for health education and risk reduction (HERR) activities, and 1.000 (n = 5, p < .05) for counseling, testing, referral, and partner notification (CTRPN) activities. From 1997 to 1998, the proportion of funds targeted and accounted for by race/ethnicity increased from 79 percent to 88 percent for HERR, and from 71 percent to 84 percent for CTRPN activities. With regard to race/ethnicity, health departments and CPGs appear to be actively targeting and accounting for HIV prevention resources, and we will argue that relatively small changes in counseling and testing resources for African-American and Latino/Latina communities would result in a close match between AIDS prevalence data and devoted resources.
Forty-eight sexually active adolescents participated in an open-ended interview about the possible secondary consequences (side effects) of implementing measures to reduce the risk of contracting a sexually transmitted disease (STD). These adolescents noted 134 different consequences, which were grouped into 15 substantive categories. When four prevention measures (using condoms, being selective about sex partner(s), being monogamous, and abstaining from sexual activity) were analyzed, different patterns of consequences that were salient to these adolescents emerged. The results are discussed in terms of their implications for understanding and improving adolescent decision making about STD prevention.
1. Measurements were made in four normal human subjects of the accuracy of saccades to remembered locations of targets that were flashed on a 20 x 30 deg random dot display that was either stationary or moving horizontally and sinusoidally at +/-9 deg at 0.3 Hz. During the interval between the target flash and the memory-guided saccade, the "memory period" (1.4 s), subjects either fixated a stationary spot or pursued a spot moving vertically sinusoidally at +/-9 deg at 0.3 Hz. 2. When saccades were made toward the location of targets previously flashed on a stationary background as subjects fixated the stationary spot, median saccadic error was 0.93 deg horizontally and 1.1 deg vertically. These errors were greater than for saccades to visible targets, which had median values of 0.59 deg horizontally and 0.60 deg vertically. 3. When targets were flashed as subjects smoothly pursued a spot that moved vertically across the stationary background, median saccadic error was 1.1 deg horizontally and 1.2 deg vertically, thus being of similar accuracy to when targets were flashed during fixation. In addition, the vertical component of the memory-guided saccade was much more closely correlated with the "spatial error" than with the "retinal error"; this indicated that, when programming the saccade, the brain had taken into account eye movements that occurred during the memory period. 4. When saccades were made to targets flashed during attempted fixation of a stationary spot on a horizontally moving background, a condition that produces a weak Duncker-type illusion of horizontal movement of the primary target, median saccadic error increased horizontally to 3.2 deg but was 1.1 deg vertically. 5. When targets were flashed as subjects smoothly pursued a spot that moved vertically on the horizontally moving background, a condition that induces a strong illusion of diagonal target motion, median saccadic error was 4.0 deg horizontally and 1.5 deg vertically; thus the horizontal error was greater than under any other experimental condition. 6. In most trials, the initial saccade to the remembered target was followed by additional saccades while the subject was still in darkness. These secondary saccades, which were executed in the absence of visual feedback, brought the eye closer to the target location. During paradigms involving horizontal background movement, these corrections were more prominent horizontally than vertically. 7. Further measurements were made in two subjects to determine whether inaccuracy of memory-guided saccades, in the horizontal plane, was due to mislocalization at the time that the target flashed, misrepresentation of the trajectory of the pursuit eye movement during the memory period, or both. 8. The magnitude of the saccadic error, both with and without corrections made in darkness, was mislocalized by approximately 30% of the displacement of the background at the time that the target flashed. The magnitude of the saccadic error also was influenced by net movement of the background during the memory period, corresponding to approximately 25% of net background movement for the initial saccade and approximately 13% for the final eye position achieved in darkness. 9. We formulated simple linear models to test specific hypotheses about which combinations of signals best describe the observed saccadic amplitudes. We tested the possibilities that the brain made an accurate memory of target location and a reliable representation of the eye movement during the memory period, or that one or both of these was corrupted by the illusory visual stimulus. Our data were best accounted for by a model in which both the working memory of target location and the internal representation of the horizontal eye movements were corrupted by the illusory visual stimulus. We conclude that extraretinal signals played only a minor role, in comparison with visual estimates of the direction of gaze, in planning eye movements to remembered targ
We compared ocular and eye-head tracking responses to an illusion of diagonal motion produced when vertical movement of a small visual target was synchronized to horizontal movement of a background display. In response to sinusoidal movement, smooth ocular pursuit followed vertical target motion, with only a small horizontal component. In response to regular stepping movement, all anticipatory saccades were in the direction of the illusion; these erroneous oblique movements were followed by corrective horizontal saccades. When the head was free to move, it usually showed a diagonal trajectory that, for both sinusoidal and stepping target motion, was always in the direction of the illusion; no corrective movements were present. Thus, for our illusory stimuli, eye and head tracking showed qualitative differences that imply that ocular tracking was ultimately controlled by actual target motion but head tracking was controlled by illusory target motion.
1. Humans may visually track a moving object either when they are stationary or in motion. To investigate visual-vestibular interaction during both conditions, we compared horizontal smooth pursuit (SP) and active combined eye-head tracking (CEHT) of a target moving sinusoidally at 0.4 Hz in four normal subjects while the subjects were either stationary or vibrated in yaw at 2.8 Hz. We also measured the visually enhanced vestibuloocular reflex (VVOR) during vibration in yaw at 2.8 Hz over a peak head velocity range of 5-40 degrees/s. 2. We found that the gain of the VVOR at 2.8 Hz increased in all four subjects as peak head velocity increased (P < 0.001), with minimal phase changes, such that mean retinal image slip was held below 5 degrees/s. However, no corresponding modulation in vestibuloocular reflex gain occurred with increasing peak head velocity during a control condition when subjects were rotated in darkness. 3. During both horizontal SP and CEHT, tracking gains were similar, and the mean slip speed of the target's image on the retina was held below 5.5 degrees/s whether subjects were stationary or being vibrated at 2.8 Hz. During both horizontal SP and CEHT of target motion at 0.4 Hz, while subjects were vibrated in yaw, VVOR gain for the 2.8-Hz head rotations was similar to or higher than that achieved during fixation of a stationary target. This is in contrast to the decrease of VVOR gain that is reported while stationary subjects perform CEHT.(ABSTRACT TRUNCATED AT 250 WORDS)
Pulsed fluoroscopy (hereafter called pulsed) at reduced acquisition rates, typically 15 acq/s (pulsed-15), is proposed to reduce x-ray dose in interventional procedures. However, since the human visual system (HVS) acts as a temporal low-pass filter that interacts with such acquisitions, the proper dose for pulsed must be obtained in perception experiments. We determine the dose for low-frame-rate pulsed that gives visualization equivalent to that of conventional 30 acq/s fluoroscopy, hereafter called continuous. Computer-generated phantoms are used. They consist of stationary, low-contrast disks on a flat background containing Poisson noise that mimics quantum noise in fluoroscopy. Image sequences are displayed on the video tachistoscope, a device with considerable display flexibility. Three experimental paradigms are used. (1) In a paired-comparison study, pulsed and continuous are displayed side-by-side on the same monitor, and the visibility of a contrast detail phantom is compared. (2) Using this same display, subjects record the minimally detectable disk contrast (the min-contrast measurement). (3) In a four-alternative forced-choice experiment, a disk is placed in one of four positions, and the subject determines the position of the disk. The methods are complementary--the forced-choice experiment properly eliminates the subjectivity of the observer threshold while the paired-comparison study is much more time efficient. With regard to pulsed and continuous comparisons, remarkable similarity is found between the supra-threshold experiments (1 and 2) and the detectability experiment (3); i.e., the average absolute differences in the equivalent-perception dose as determined by the three measures is approximately 3%. No difference is found between interlaced and noninterlaced display. A relatively small dependence of dose savings on disk size is found with larger disks giving increased dose savings. Average dose savings of 22%, 38%, and 49% are found for pulsed-15, pulsed-10, and pulsed-7.5, respectively.
Pulsed fluoroscopy at reduced frame rates can be used to lower x-ray dose with equivalent detection (hereafter called equivalent perception) of low-contrast, stationary objects. Experimentally average dose savings of 22%, 38%, and 49%, for pulsed fluoroscopy at 15, 10, and 7.5 acquisitions per second, respectively, are documented. Dose savings depend on object size, with fewer savings for smaller objects. To explain these data, we extend the framework of an ideal observer with three models for the spatiotemporal response of the human visual system (HVS). They are model 1, separable; model 2, nonseparable; and model 3, nonseparable with internal observer noise. With no free parameters, model 1 predicts the average dose savings within a 3% difference but does not describe the effect of object size. Models 2 and 3 explain the influence of size, and model 3, with a single free parameter, fits the measurements best. Perception of pulsed fluoroscopy is thus well described in terms of spatiotemporal processing by the HVS.
Patients with coarctation of the aorta (CoA) who previously underwent successful surgery are often diagnosed on standard electrocardiograms as having partial right bundle branch block. After surgery 24 patients with CoA had body surface potential mapping (BSPM) with the Case Western Reserve University 180 electrode system; of these 7 had additional aortic stenosis and none had ever had intracardiac communication. The average age at the initial surgery for CoA was 4.0 +/- 3.3 years and at the time of the BSPM it was 12.7 +/- 5.9 years. For the 17 patients with CoA without aortic stenosis the average age at the initial surgery was 5.0 +/- 3.4 years and at the time of the BSPM it was 14.2 +/- 6.0 years. In 11 of the 24 patients, a cardiac catheterization was performed, and each patient demonstrated normal pulmonary artery and right ventricular systolic pressure except for one child with 40 mmHg systolic. In the others all indications were that right ventricular pressure was normal. In 11 of the 24 patients, congestive heart failure had been present in infancy. All 24 cases had evidence for epicardial right ventricular breakthrough on the BSPM, a finding believed to indicate right ventricular activation from endocardium to epicardium via the normal Purkinje system. There were no findings on the BSPM suggesting that right bundle branch block was present. Right ventricular hypertrophy with or without terminal right conduction delay was present on the BSPM in 19 of the 24 patients (9 with additional left ventricular hypertrophy--left ventricular hypertrophy alone in 5). Right ventricular hypertrophy could be considered in 6 of 19 patients in the electrocardiogram, and in 11 of 19 in the vectorcardiogram. The mechanism for the persistent electrocardiographic right ventricular hypertrophy is postulated to involve right ventricular hyperplasia in utero or in early neonatal life, which never disappears.
Using the magnetic search coil technique, we measured torsional eye movements in four male subjects during and after rotation of a visual display around the line of sight. During rotation of the display, subjects developed a torsional nystagmus with slow-phases in the direction of target rotation that had a typical gain of less than 0.01. Upon cessation of display motion, subjects experienced a motion after-effect (MAE) in the direction opposite prior target rotation, which persisted for greater than 15 sec. During this MAE, slow-phase eye movements of low velocity were in the same direction as the MAE, but did not persist as long as perceptual effects. In separate experiments, horizontal eye movements were recorded during horizontal stimulus motion; during MAE, no eye movements occurred due to stronger fixation mechanisms. We conclude that MAE is not caused by retinal slip of images, but MAE and the accompanying eye movements might be produced by shared or similar mechanisms.
1. We used a modeling approach to test the hypothesis that, in humans, the smooth pursuit (SP) system provides the primary signal for cancelling the vestibuloocular reflex (VOR) during combined eye-head tracking (CEHT) of a target moving smoothly in the horizontal plane. Separate models for SP and the VOR were developed. The optimal values of parameters of the two models were calculated using measured responses of four subjects to trials of SP and the visually enhanced VOR. After optimal parameter values were specified, each model generated waveforms that accurately reflected the subjects' responses to SP and vestibular stimuli. The models were then combined into a CEHT model wherein the final eye movement command signal was generated as the linear summation of the signals from the SP and VOR pathways. 2. The SP-VOR superposition hypothesis was tested using two types of CEHT stimuli, both of which involved passive rotation of subjects in a vestibular chair. The first stimulus consisted of a "chair brake" or sudden stop of the subject's head during CEHT; the visual target continued to move. The second stimulus consisted of a sudden change from the visually enhanced VOR to CEHT ("delayed target onset" paradigm); as the vestibular chair rotated past the angular position of the stationary visual stimulus, the latter started to move in synchrony with the chair. Data collected during experiments that employed these stimuli were compared quantitatively with predictions made by the CEHT model. 3. During CEHT, when the chair was suddenly and unexpectedly stopped, the eye promptly began to move in the orbit to track the moving target. Initially, gaze velocity did not completely match target velocity, however; this finally occurred approximately 100 ms after the brake onset. The model did predict the prompt onset of eye-in-orbit motion after the brake, but it did not predict that gaze velocity would initially be only approximately 70% of target velocity. One possible explanation for this discrepancy is that VOR gain can be dynamically modulated and, during sustained CEHT, it may assume a lower value. Consequently, during CEHT, a smaller-amplitude SP signal would be needed to cancel the lower-gain VOR. This reduction of the SP signal could account for the attenuated tracking response observed immediately after the brake. We found evidence for the dynamic modulation of VOR gain by noting differences in responses to the onset and offset of head rotation in trials of the visually enhanced VOR.(ABSTRACT TRUNCATED AT 400 WORDS)
We describe a procedure for modifying horizontal eye movement measurements in a way that effectively removes signal contributions due to the eccentric location of the eyes relative to the center of rotation of the head. This procedure helps standardize measured signals so that data collected under different experimental conditions and from different subjects may be compared directly. We also present techniques for accurately determining specific parameters of head geometry that are required by the procedure. This method may be used for modifying eye movement responses to visual target motion, head motion, or both, and does not assume continual fixation of the visual target. Also, this method may be employed when either curved (iso-distance) or flat display screens are used for presenting the visual stimuli.
The portable dental X-ray machine has been used to augment standard field x-ray equipment. This allows for more rapid assessment of combat casualties. The data presented describe the use of the portable dental X-ray machine during the 100-hour ground war against Iraq.
BACKGROUND: A reliable, noninvasive procedure to determine the location of accessory atrioventricular connections in patients with Wolff-Parkinson-White syndrome would add an important diagnostic tool to the clinical armamentarium. METHODS AND RESULTS: Body surface potential mapping (BSPM) using 180 electrodes in various-sized vests and displayed as a calibrated color map was used to determine the ventricular insertion site of the accessory atrioventricular (AV) connections in 34 patients with Wolff-Parkinson-White syndrome. Attempts were made to determine the 17 ventricular insertion sites described by Guiraudon et al. All 34 patients had an electrophysiologic study (EPS) at cardiac catheterization, and 18 had surgery so the ventricular insertion sites could be accurately located using EPS at surgery. A number of physiologic observations were also made with BSPM. CONCLUSIONS: The following conclusions were drawn: 1) BSPM using QRS analysis accurately predicts the ventricular insertion site of accessory AV connections in the presence of a delta wave in the electrocardiogram; 2) the ventricular insertion sites of accessory AV connections determined by BSPM and by EPS at surgery were identical or within one mapping site (1.5 cm or less) in all but four of 18 cases; three of the four exceptions had more than one accessory AV connection, and the other had a very broad ventricular insertion; 3) BSPM and EPS locations of the accessory AV connections correlated very well in the 34 cases despite the fact that BSPM determines the ventricular insertion site and EPS determines the atrial insertion site of the accessory AV connection; 4) as suggested by the three cases of multiple accessory AV connections, EPS and BSPM may be complementary since BSPM identified one pathway and EPS identified the other (in the case with a broad ventricular insertion, BSPM and EPS demonstrated different proportions of that insertion); 5) BSPM using ST-T analysis is very much less accurate in predicting the ventricular insertion site of accessory AV connections unless there is marked preexcitation; 6) standard electrocardiography using the Gallagher grid methodology (but with no attempt at stimulating maximal preexcitation) was not as accurate as QRS analysis of BSPM in predicting the ventricular insertion site of the accessory AV connection; however, exact comparison is hampered by the different number and size of the Gallagher and Guiraudon insertion sites; 7) BSPM using QRS analysis appears to be very accurate in predicting right ventricular versus left ventricular posteroseptal accessory AV connections; 8) typical epicardial right ventricular breakthrough, indicative of conduction via the specialized AV conduction system, occurs in all patients with left ventricular free wall accessory AV connections; 9) epicardial right ventricular breakthrough was not observed in cases with right ventricular free wall or anteroseptal accessory AV connections; 10) epicardial right ventricular breakthrough can occur in the presence of posteroseptal accessory AV connections, whether right or left ventricular; and 11) the delay in epicardial right ventricular breakthrough in cases with left ventricular insertion may provide a marker to estimate the degree of ventricular preexcitation.
Stylized chromosome images 1) serve as a format to test effects of preprocessing algorithms used in automated karyotyping; 2) enhance the ability of humans to perform quantitative analysis of chromosomal aberrations; 3) provide an alternative format for karyotype hard copies produced by automated systems. Stylized chromosomes are two-dimensional computer-generated images based on information extracted from one-dimensional width and density profiles. These profiles correspond to what cytogeneticists observe through the microscope as the shape and banding patterns of stained chromosomes. Stylized presentation sharpens chromosome band boundaries and perimeters, reduces "noise," and enhances gray level variations, which are difficult to distinguish by humans on photographic or computer generated karyotypes. Karyotyping accuracy using stylized images was used to detect difficult areas for automated chromosome identification. Landmark bands sufficient to classify chromosomes were identified; shapes of chromosomes reflected in width profiles were said to aid classification. A two-step automated karyotyping strategy proposed is: 1) classify chromosomes by landmarks, minimum information needed for identification; 2) subsequently employ the full banding pattern with maximum resolution to detect aberrations. Stylized images of abnormal chromosomes have potential for testing hypothesis regarding breakpoints and quantitative analysis, but improvements are needed in homologue normalization and definition of termini of chromosomes.
A new automatic spatiotemporal algorithm has been developed for detecting QRS onset and offset in body surface potential mapping. The new algorithm, based on a spatial and temporal approach, along with three other algorithms (total energy, 3-lead, and median), was tested in 73 normal and abnormal patients. The reference or gold standard onset and offset times were determined visually by two experienced investigators. The results demonstrate that the new method is less sensitive to noise, to the temporal overlap of the QRS and other components, and to the spatial location changes of QRS initial and final activation. The spatiotemporal method resulted in very consistent findings, with a standard deviation of less than one third of the standard deviation in the next best method.