A feedback controlled silicon microprobe for quantitative mechanical stimulation of nerve and tissue.

The ability to apply and control the force and force velocity of mechanical stimulation is essential for the study of mechanoelectric transduction and adaptation processes. Silicon micromachining technology was used to produce miniature (20-70 microns wide) mechanical microprobes. Passive polysilicon, piezoresistive, force sensing elements were deposited onto the boron-doped epitaxial silicon and the individual devices were chemically etched from the bulk wafer. These microprobes display a linear force versus output voltage relationship. Stimulation forces up to 2 mN can be generated with a measurement resolution of 1.5 microN. The probes were mounted onto circuit board holders and their output sent to a proportional-integral controller which drives an electromagnetic actuator. By using this force-feedback control circuit coupled to a PC it is possible to define any stimulus wave form pattern and independently control and measure the actual stimulus force and velocity. A computer controlled 3-axis stepper motor (0.025 micron step capability) manipulator is used to position the silicon microprobe-actuator assembly relative to the mechanoreceptive field. Sensor feedback control coupled to the 3-axis stepper motor manipulator allows automatic touchdown control and/or preloading of the probe prior to stimulation. Three-dimensional topographic manipulator feedback position control allows automated receptive field mapping.

Action Potentials↗

Force-sensing microprobe for precise stimulation of mechanosensitive tissues.

Quantitative study of the transduction mechanisms in mechanically sensitive nerve terminals has been impeded by the lack of instrumentation with which to generate precisely controlled, physically localized mechanical stimuli. We have developed high-resolution force sensing mechanical microprobes for use in the characterization of such nerve terminals. This paper describes their design, fabrication, and testing. A microprobe is comprised of a 0.5- to 2-mm long silicon cantilever beam projecting from a larger supporting silicon substrate. Acting as the variable leg of a Wheatstone bridge circuit, a piezoresistive polysilicon element located at the base of the beam is used to measure the stimulation force applied at the tip. The microprobes exhibit a stable, linear relationship between the stimulation force and the resulting output voltage signal. Stimulation forces up to 3 mN have been generated with a measurement resolution of 10 microN. These microprobes have been used as the force sensing element of a closed loop feedback-controlled stimulation system capable of stimulating the mechanoreceptive nerve terminals of the rabbit corneal epithelium.

Animals↗

Silicon-substrate microelectrode arrays for parallel recording of neural activity in peripheral and cranial nerves.

A new process for the fabrication of regeneration microelectrode arrays for peripheral and cranial nerve applications is presented. This type of array is implanted between the severed ends of nerves, the axons of which regenerate through via holes in the silicon and are thereafter held fixed with respect to the microelectrodes. The process described is designed for compatibility with industry-standard CMOS or BiCMOS processes (it does not involve high-temperature process steps nor heavily-doped etch-stop layers), and provides a thin membrane for the via holes, surrounded by a thick silicon supporting rim. Many basic questions remain regarding the optimum via hole and microelectrode geometries in terms of both biological and electrical performance of the implants, and therefore passive versions were fabricated as tools for addressing these issues in on-going work. Versions of the devices were implanted in the rat peroneal nerve and in the frog auditory nerve. In both cases, regeneration was verified histologically and it was observed that the regenerated nerves had reorganized into microfascicles containing both myelinated and unmyelinated axons and corresponding to the grid pattern of the via holes. These microelectrode arrays were shown to allow the recording of action potential signals in both the peripheral and cranial nerve setting, from several microelectrodes in parallel.

Action Potentials↗

Regeneration microelectrode array for peripheral nerve recording and stimulation.

A microelectrode array capable of recording from and stimulating peripheral nerves at prolonged intervals after surgical implantation has been demonstrated. The microelectrode array, fabricated on a silicon substrate perforated by multiple holes (referred to as via holes), is implanted between the ends of a surgically severed nerve. Regenerating tissue fixes the device in place to provide a stable mapping between the microelectrodes and the axons in the nerve. Processes were developed for the fabrication of thin-film iridium microelectrodes, micromachined via holes, and silicon nitride passivation layers. All fabrication methods were designed to be compatible with standard CMOS/BiCMOS processes to allow for on-chip signal processing circuits in future designs. Such arrays, implanted in the peroneal nerves of rats, were used to record from and stimulate the nerves at up to 13 months postoperatively.

Animals↗

A method for evaluating the selectivity of electrodes implanted for nerve simulation.

The scale of stimulating electrodes possible for use in functional electrical stimulation to restore motor and sensory function is rapidly approaching that of individual neurons. Although the electrodes may approach the dimensions of single nerve cells, it is unclear if the region of excitation elicited by each electrode will be correspondingly small. Previous techniques for evaluating this have either been tedious or have lacked the resolution necessary. This paper describes a method that uses the refractory interaction of the compound action potentials elicited by a stimulus pulse pair, along with high-resolution recording of those potentials, to achieve measurements of the selectivity of stimulation down to the scale of a few axon diameters. The feasibility of this technique is demonstrated in sciatic nerves of frogs (Rana Catesbiana) acutely implanted with a sapphire electrode array.

Action Potentials↗