A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models.

A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all patients. The design time was reduced from 4 to 0.5 hr.

Adult↗

Study of anatomic constraints using three dimensionally reconstructed images for total artificial heart implantation.

The authors established a method of clarifying the three dimensional interrelationship among the mitral and tricuspid annuli, ascending aorta, main pulmonary artery, diaphragmatic surface of the heart (DS), and anterior thoracic wall, using four chamber view magnetic resonance imaging. This method was applied to measuring the parameters that restrict the size and shape of a total artificial heart (TAH) from three dimensional reconstructed images of six normal subjects. Assuming that the TAH is implanted on the diaphragm, which corresponds to DS, the width of the TAH is restricted to 7.6 cm, the transverse dimension of the cardiac base (D-B), and the height to 7.8 cm, the dimension from the DS to the center of the pulmonic annulus (DS-P1). Depth is restricted by the longitudinal dimension of the left ventricle projected on the DS (D-L). While D-L in early systole is 9.7 mm, in late systole D-L is reduced to 7.6 cm. The angle (DS) (AW) is 65.7 degrees; this is the angle between the DS and anterior thoracic wall that restricts the shape of the TAH. While these data in normal subjects may be useful for TAH implantation, in the patient with acute cardiac failure, further study of patients with chronic cardiac failure is necessary.

Adult↗

Development of an electrohydraulic total artificial heart at the National Cardiovascular Center, Osaka, Japan.

The authors have been developing an electrohydraulic total artificial heart with a basic concept placing the blood pumps and an electrohydraulic energy converter separately, in the thorax and the abdominal region, respectively, to minimize anatomic constraints. Major problems of the system were a high energy consumption of 56 W at 6 L/min output and an insufficient maximum output of 6.7 L/min. The energy converter was redesigned to overcome these problems. A three phase, 4 pole brushless DC motor, which has maximum efficiency of 79% at a motor rotation of 2500 rpm with a load of 0.1 Nm, was developed for the new energy converter. Flow-channel design of the regenerative oil pump was optimized, which resulted in increasing the maximum flow rate at one directional motor rotation from 18 to 29 L/min. In vitro performance of the electrohydraulic total artificial heart was evaluated in a mock circulation with physiologic pressure conditions. Maximum output was increased to 10.7 L/min at a pump rate of 120 bpm and energy consumption of the motor at 6 L/min output was reduced to 18 W. Based upon these favorable results, the system is now being assembled for chronic animal implantation.

Animals↗

Set-up, improvement, and evaluation of an electrohydraulic total artificial heart with a separately placed energy converter.

The authors have been developing an electrohydraulic total artificial heart (TAH) system with a separately placed electrohydraulic energy converter to minimize anatomic constraints in the pericardial space. Improvements to the system and current status of the development are reported. The energy converter was miniaturized to improve implantability, and its thickness was reduced to 54 mm. System efficiency was increased by suppressing rush current at the time of motor reversal. Maximum cardiac output of the TAH system was 9 L/min, and maximum system efficiency increased to 10%. The blood pump system was implanted easily in the body of a 57 kg calf, and no significant temperature rise on the energy converter surface was observed. As the next step, main components were integrated into a total system. The transcutaneous energy transfer system could supply power to the TAH without a decline in pump performance, and the internal battery could support the system at 6.5 L/min of cardiac output for 1 hour without a decrease in cardiac output. The authors consider the TAH system with a separately placed energy converter the most promising approach to development of a TAH for smaller sized patients.

Animals↗

The inflexible mitral annulus after valve prosthesis. Inherent risk of dynamic left ventricular outflow tract obstruction.

Although chordal preserving mitral valve replacement is beneficial to cardiac function, the loss of flexibility of the annulus and consequent translational motion of the valve prosthesis during systole may cause potential left ventricular outflow tract (LVOT) obstruction after surgery. The extent of the flexibility of the mitral valve annulus (MVA) necessary for the prosthetic valve to prevent potential LVOT obstruction was determined. The three dimensional images of the MVA at 0, 100, 200, and 300 msec delay from the electrocardiogram R wave were reconstructed from cine-mode magnetic resonance images in eight normal subjects. In the lateral view of the MVA, the dorsal flexion angle (DFA) was defined. This angle implies the extent of the flexion of the anterior half of the MVA in relation to the posterior half. The data (mean +/- SD) for the DFA were 31.7 +/- 5.4 degrees (0 msec), 36.4 +/- 4.5 degrees (100 msec), 39.0 +/- 3.8 degrees (200 msec), and 43.6 +/- 2.6 degrees (300 msec), whereas the systolic increase in DFA was 11.9 +/- 3.2 degrees. The flexibility observed in normal mitral annuli is relevant to prosthetic mitral valves.

Adult↗

The relationship between the mitral annulus and left ventricular outflow tract.

Mitral annular inflexibility due to rigid prostheses (ring or valve) has long been considered to contribute to the mechanism of dynamic left ventricular outflow tract (LVOT) obstruction after mitral repair or replacement. In clarifying the geometric relationship between LVOT orifice and mitral valve annulus (MVA) in eight normal subjects, the authors have endeavored to show how that a rigid mitral prosthesis might obstruct the LVOT based on the assumption that any rigid prosthesis necessarily follows the motion of the posterior half of the MVA (MVApost) in the course of every heart beat. During systole, the relationship between the MVApost and the approximated plane of the LVOT orifice was constant. However, with the respect to the relationship between the LVOT orifice and the approximated plane of the MVApost (PI-MVApost), the intersection between the two shifted toward the apex during systole. Assuming the prosthesis is aligned on the MVApost with the same orientation as the PI-MvApost, this shift implies a reduction in the effective size of the LVOT orifice due to the prosthesis. The calculated obstruction rate was 24.9% (0 ms), 30.9% (100 ms), 35.5% (200 ms), and 45.4% (300 ms). These results indicate the importance of maintaining the flexibility of the MVA after mitral valve surgery.

Adult↗

Effects of prosthetic valve placement on mitral annular dynamics and the left ventricular base.

Insertion of a rigid mitral prosthesis impairs the function of the mitral annulus and induces systolic narrowing of the left ventricular outflow tract (LVOT). To study this mechanism, we investigated dynamic changes in the left ventricular (LV) base, which consists of the mitral annulus and LVOT orifice. In seven patients with mechanical mitral valve prostheses and eight normal subjects, the image of the LV base was reconstructed three-dimensionally and its dynamic change during systole was studied. In the patients, the rigid prosthetic valve (=mitral annulus) tilted toward the left ventricle with a hinge point at the posterior mitral annulus during systole. The left ventricular base exhibited contraction, but the size of the prosthetic valve was constant. As a consequence, the prosthetic valve occupied more of the left ventricular base, which resulted in narrowing of the LVOT. In the normal subjects, the mitral annulus did not interfere with the region of the LVOT orifice during systole as the mitral annulus underwent both dorsiflexion and contraction. Thus, fixation of the mitral annulus induces an anti-physiologic motion of the annulus. Conscious preservation of annular flexibility in mitral valve surgery is important in avoiding potential dynamic LVOT obstruction.

Adult↗

Mitral annular flexibility.

An analysis of three-dimensional movement of the mitral valve annulus (MVA) may address the question of geometrical change after mitral valve repair to preserve mitral annular function. Conventionally, annular contraction has been studied for this purpose. We investigated this geometrical change occurring in the anterior half of the MVA and discuss its clinical significance. Three-dimensional images of the MVA during systole were reconstructed from magnetic resonance images of eight normal subjects. The posterior half of the MVA exhibited translational motion. We assume that this portion, exhibiting translational motion as well as contraction, purely follows the motion of the left ventricular contraction. Compensating for the discrepancy between the motion of the aortic root and that of the posterior half of the MVA, the anterior half exhibited a flexible change in shape during systole, thus maintaining a sufficient left ventricular outflow tract (LVOT). The increase in the extent of displacement of the anterior MVA from the posterior half of the MVA during systole, which was 3.6 +/- 1.0 mm (mean +/- SD), indicates the annular flexibility. The preservation of annular flexibility may prevent LVOT obstruction. Further geometrical analysis of patients after mitral repair will clarify annular function as presented in this article.

Adult↗

Reconstructed image of the human heart based on magnetic resonance images for total artificial heart implantation.

Parameters used to develop a three-dimensional reconstructed image of the remaining heart after total artificial heart implantation (i.e., for the mitral and tricuspid annuli, ascending aorta (AO), and pulmonary artery [PA]) were calculated based on reconstructed images from data obtained from four magnetic resonance (MR) image views: 1) transverse, 2) coronal, 3) left ventricular long axis (LAX), and 4) four chamber view (FCV). The values obtained were compared with those obtained from silicone models of the same hearts. It was found that, of the four MR image views, LAX and FCV provided the greatest numbers of points reflecting annular contour that were useful in reconstruction of the atrioventricular (AV) annuli, and the highest percentages of segmented outline-connecting points less than 1 cm apart for the total outline. The AV annuli were sliced in the least slice time using FCV imaging. The authors applied FCV MR imaging to a beating heart to reconstruct the AV annuli and obtained accurate results. To quantify more accurately the data for the axis directions of AO and PA, research to establish a new orientation on the thorax is in progress.

Artifacts↗

The three-dimensional relationships between mitral and tricuspid valvular annuli for total artificial heart implantation.

The three-dimensional relationship between the mitral valvular annulus (MVA) and tricuspid valvular annulus (TVA) was studied in 32 cadaver hearts. It was found that when the distance from the center of the MVA and TVA (D-G) were standardized and when MVA and TVA were overlapped by matching their centers, MVA was located in the fan shaped region in the lateral view of the TVA and pointed toward the orifice of the coronary sinus. D-G was correlated with the volume of the space occupied by both ventricles. When the value of D-G was standardized, TVA remains free to change its shape and orientation toward either the cranial or caudal direction.

Aged↗

Three-dimensional interface geometry of the human heart with the artificial heart.

The interface geometry of human and artificial hearts was defined. It included: 1) the approximate mitral orifice and mitral orifice planes; 2) the approximate tricuspid orifice and tricuspid orifice planes; 3) the long and short diameters of the aorta; 4) the long and short diameters of the pulmonary artery; and 5) the angles between the mitral orifice and tricuspid orifice planes, as well as the axes of the aorta and pulmonary artery. The orifice plane was defined as a plane such that the sum of the squared distances between the plane and points on the orifice contour was minimized. A standard coordinate system was also defined, whose origin was the centroid of the approximate mitral orifice. Its X-Y plane was the approximate mitral orifice plane. One set of interface parameters was determined using magnetic resonance images of a volunteer's heart. The angle between the approximate mitral orifice plane and tricuspid plane was found to be 19.9 degrees. The areas of the approximate mitral and tricuspid orifices were 1020 and 1655 mm2, respectively. The approximate mitral orifice was covered by a 44 x 40 mm rectangle and the approximate tricuspid orifice was covered by a 59 x 41 mm rectangle. This interface geometry is important, not only in the manufacture of artificial hearts of precise dimensions, but also in avoiding complications due to their long-term use.

Computer Graphics↗

Dynamic change in the left ventricular base with or without a rigid mitral valve prosthesis.

To evaluate the narrowing of the left ventricular outflow tract (LVOT) during systole caused by a rigid mitral prosthesis, the geometric relationship between the prosthesis (or the mitral annulus) and the left ventricular base (LVB) was studied in five patients with mechanical mitral valve prostheses and eight normal subjects. The images of the mitral valve annulus (MVA) and the LVOT orifice reconstructed in three dimensions were projected on the plane of the LV base. Calculating the areas of these projected images (i.e., those for MVA [Sm], LVOT orifice [So], the LVB [Sb; Sb = Sm + So]), the MVA-LVB ratio (Sm/Sb) was determined. In the normal subject, the MVA-LVB ratio was nearly constant during systole (59 +/- 5% at 0 msec and 62 +/- 7% at 300 msec, respectively), whereas in the patients with prostheses, the ratio increased from 61 +/- 4% (0 msec) to 69 +/- 4% (300 msec). The increase in MVA-LVB ratio reduces the proportionate share of LVOT orifice in relation to the total LVB. The ideal mitral valve prosthesis should be flexible at the annulus to attain good performance in LVB dynamics.

Adult↗