On-line correction and visualization of motion during MRI-controlled hyperthermia.

Displacement of tissue during MRI-controlled hyperthermia therapy can cause significant problems. Errors in calculated temperature may result from motion-related image artifacts and inter-image object displacement, leading to incorrect spatial temperature reference. Here, cyclic navigator echoes were incorporated in rapid gradient-echo MRI sequences, used for temperature mapping based on the proton resonance frequency. On-line evaluation of navigator information was used in three ways. First, motion artifacts were minimized in echo-shifted (TE > TR) gradient-echo images using the phase information of the navigator echo. Second, navigator profiles were matched for a quantitative evaluation of displacement. Together with a novel processing method, this information was employed to correct the reference temperature maps, thereby avoiding persistence of motion-related temperature errors throughout the hyperthermic period. Third, on-line visualization of displacement, together with temperature maps and thermal dose images, was developed, allowing physician intervention at all times. Examples are given of on-line corrections during hyperthermia procedures with focused ultrasound and radiofrequency heat sources. Magn Reson Med 45:128-137, 2001.

Animals↗

Diffusion tensor MRI of the human kidney.

This study characterizes the diffusion anisotropy of the human kidney using a diffusion-weighted, single-shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medulla were found to be 0.22 +/- 0.12 and 0.39 +/- 0.11, respectively (N = 10), which emphasizes the need for rotationally invariant diffusion measurements for clinical applications. Additional limitations for clinical diffusion imaging on the kidney are the strong susceptibility variations within the abdomen that restrict the use of imaging techniques employing long echo trains, and the severe motion sensitivity that limits the available imaging time to one breath-hold. To overcome these problems an isotropic, diffusion-weighted, segmented EPI protocol that facilitates the acquisition of high-resolution diffusion-weighted images within a single breath-hold was implemented. Using this method, the apparent diffusion coefficient (ADC) of the cortex and medulla were found to be 2.89 +/- 0.28. 10(-9) m2/s and 2.18 +/- 0.36. 10(-9) m2/s (N = 10).

Anisotropy↗

Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction.

Temperature regulation in MR-guided focused ultrasound requires rapid MR temperature mapping and automatic feedback control of the ultrasound output. Here, a regulation method is proposed based on a physical model of local energy deposition and heat conduction. The real-time evaluation of local temperature gradients from temperature maps is an essential element of the control system. Each time a new image is available, ultrasound power is adjusted on-the-fly in order to obtain the desired evolution of the focal point temperature. In vitro and in vivo performance indicated fast and accurate control of temperature and a large tolerance of errors in initial estimates of ultrasound absorption and heat conduction. When using correct estimates for the physical parameters of the model, focal point temperature was controlled within the measurement noise limit. Initial errors in absorption and diffusion parameters are compensated for exponentially with a user-defined response time, which is suggested to be on the order of 10 sec.

Animals↗

Magnetic resonance temperature imaging for guidance of thermotherapy.

Continuous thermometry during a hyperthermic procedure may help to correct for local differences in heat conduction and energy absorption, and thus allow optimization of the thermal therapy. Noninvasive, three-dimensional mapping of temperature changes is feasible with magnetic resonance (MR) and may be based on the relaxation time T(1), the diffusion coefficient (D), or proton resonance frequency (PRF) of tissue water. The use of temperature-sensitive contrast agents and proton spectroscopic imaging can provide absolute temperature measurements. The principles and performance of these methods are reviewed in this paper. The excellent linearity and near-independence with respect to tissue type, together with good temperature sensitivity, make PRF-based temperature MRI the preferred choice for many applications at mid to high field strength (>/= 1 T). The PRF methods employ radiofrequency spoiled gradient-echo imaging methods. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 second and a spatial resolution of about 2 mm, is feasible for a single slice for immobile tissues. Corrections should be made for temperature-induced susceptibility effects in the PRF method. If spin-echo methods are preferred, for example when field homogeneity is poor due to small ferromagnetic parts in the needle, the D- and T(1)-based methods may give better results. The sensitivity of the D method is higher that that of the T(1) methods provided that motion artifacts are avoided and the trace of D is evaluated. Fat suppression is necessary for most tissues when T(1), D, or PRF methods are employed. The latter three methods require excellent registration to correct for displacements between scans.

Animals↗

Local hyperthermia with MR-guided focused ultrasound: spiral trajectory of the focal point optimized for temperature uniformity in the target region.

The objective of hyperthermia treatment is to deliver a similar therapeutic thermal dose throughout the target volume within a minimum amount of time. We describe a noninvasive approach to this goal based on magnetic resonance imaging (MRI)-guided focused ultrasound (FUS) with a spherical transducer that can be moved along two directions inside the bed of a clinical MR imager and that has an adjustable focal length in the third dimension. Absorption of FUS gives rise to a highly localized thermal buildup, which then spreads by heat diffusion and blood perfusion. A uniform temperature within a large target volume can be obtained using a double spiral trajectory of the transducer focal point together with constant and maximum FUS power. Differences between the real and target temperatures during the first spiral are evaluated in real time with temperature MRI and corrected for during the second spiral trajectory employing FUS focal point velocity modulation. Once a uniform temperature distribution is reached within the entire volume, FUS heating is applied only at the region's boundaries to maintain the raised temperature levels. Heat conduction, together with the design and timing of the trajectories, therefore ensures a similar thermal dose for the entire target region. Good agreement is obtained between theory and experimental results in vitro on gel phantoms, ex vivo on meat samples, and in vivo on rabbit thigh muscle. Edema in muscle was visible 1 hour after hyperthermia as a spatially uniform rise of the signal intensity in T(2)-weighted images.

Animals↗

Diffusion tensor MRI of the spinal cord.

Apparent diffusion tensor (ADT) measurements on the spinal cord using a pulsed-field-gradient (PFG) multi-shot echo-planar imaging (EPI) sequence are presented. In a study of 10 healthy volunteers, the obtained rotationally invariant anisotropy information is compared to the results obtained by the rotationally dependent methods. The water diffusivity in the direction parallel to the fibers was found to be almost 2.5 times higher than the average diffusivity in directions perpendicular to the fibers and showed cylindrically symmetric anisotropy characteristics. The influence of partial volume effects and the point spread function on the measured results was evaluated, and it was the concluded that a resolution of 1 mm in the read and phase directions is required to obtain unbiased values. Possible clinical implications were demonstrated by investigating the diffusion characteristics of 10 patients suffering from narrowing of the cervical canal. The changes in the diffusion characteristics were found to be large enough to allow a robust detection of diffusion changes in the spine, even in cases in which conventional T(2) and T(1) weighted images were unable to detect any lesion.

Anisotropy↗

Rapid three-dimensional MR imaging method for tracking a bolus of contrast agent through the brain.

A gradient-echo three-dimensional magnetic resonance imaging technique (principles of echo shifting with a train of observations, or PRESTO) is presented for use in tracking a bolus of paramagnetic contrast agent through the brain. The approach combines a segmented echo-planar type of acquisition with echo shifting, which leads to echo times that are longer than the repetition time. Unlike echo-planar imaging, the method maintains image resolution despite drastic T2* changes and frequency shifts.

Adult↗

An echo-shifted gradient-echo MRI method for efficient diffusion weighting.

A segmented magnetic resonance imaging (MRI) method is introduced with time-efficient diffusion weighting resulting in total imaging times similar to those of single-shot methods. The approach is based on the principles of echo shifting with a train of observations (PRESTO) MRI sequence. The time efficiency of the sequence is based on the use of diffusion gradient pulses that also serve to shift the echo train to the next TR period, resulting in TE > TR. Each diffusion gradient is therefore used twice, for dephasing one set of spins as well as rephasing a second set of spins. Diffusion weighting and acquisition are thus achieved simultaneously. The sequence is validated in vitro and in vivo on rat kidney.

Animals↗

Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo imaging with spectral-spatial excitation is demonstrated, resulting in accurate and rapid, lipid-suppressed, MR thermometry. The method was validated on phantoms, fatty duck liver, and rat thigh, demonstrating improvements in both the speed and precision of temperature mapping. Heating of a rat thigh with focused ultrasound was monitored in vivo with an accuracy of 0.37 degree C and a time resolution of 438 msec.

Animals↗

Real-time control of focused ultrasound heating based on rapid MR thermometry.

RATIONALE AND OBJECTIVES: Real-time control of the heating procedure is essential for hyperthermia applications of focused ultrasound (FUS). The objective of this study is to demonstrate the feasibility of MRI-controlled FUS. METHODS: An automatic control system was developed using a dedicated interface between the MR system control computer and the FUS wave generator. Two algorithms were used to regulate FUS power to maintain the focal point temperature at a desired level. RESULTS: Automatic control of FUS power level was demonstrated ex vivo at three target temperature levels (increase of 5 degrees C, 10 degrees C, and 30 degrees C above room temperature) during 30-minute hyperthermic periods. Preliminary in vivo results on rat leg muscle confirm that necrosis estimate, calculated on-line during FUS sonication, allows prediction of tissue damage. CONCLUSIONS. The feasibility of fully automatic FUS control based on MRI thermometry has been demonstrated.

Animals↗

Magnetization transfer imaging of rat brain under non-steady-state conditions. Contrast prediction using a binary spin-bath model and a super-lorentzian lineshape.

Magnetization transfer contrast imaging using turbo spin echo and continuous wave off-resonance irradiation was carried out on rat brain in vivo at 4.7 T. By systematically varying the off-resonance irradiation power and the offset-frequency, the signal intensities obtained under steady-state for both transverse and longitudinal magnetization were successfully analyzed with a simple binary spin-bath model taking into account a free water compartment and a pool of protons with restricted motions bearing a super-Lorentzian lineshape. Due to important RF power deposition, such experimental conditions are not practical for routine imaging on humans. An extension of the model was derived to describe the system for shorter off-resonance pulse duration, i.e., when the longitudinal magnetization of the free protons has not reached a steady-state. Data sets obtained for three regions of interest, namely the corpus callosum, the basal ganglia, and the temporal lobe, were correctly interpreted for off-resonance pulse durations varying from 0.3 to 3 s. The parameter sets obtained from the calculations made it possible to predict the contrast between the different regions as a function of the pulse power, the offset frequency, and pulse duration. Such an approach could be extended to contrast prediction for human brain at 1.5 T.

Animals↗

Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure.

Motion poses severe problems for BOLD fMRI, particularly in clinical studies, as patients exhibit more involuntary movements than controls. This study focuses on the merits of a motion correction technique incorporated in multishot fMRI scans, so-called phase navigator correction. The technique entails real-time assessment and off-line elimination of signal fluctuations caused by subject motion. The purpose of this study was to quantify and characterize the effect of this type of improvement on 3D fMRI brain activity maps. For imaging, the 3D PRESTO method was used, with a relatively simple finger opposition task. The followed strategy was guided by the notion that application of any fMRI imaging tool in clinical studies requires several qualities, such as high and spatially homogeneous sensitivity to brain activity, and low sensitivity to motion. A graded motor activation protocol in 10 healthy subjects revealed that image stability was improved by approximately 20%, by the use of phase navigator correction. As a result, sensitivity for task-related BOLD signal change was enhanced considerably in the brain activity maps. Implications for use of this fMRI technique in patient studies are discussed.

Adult↗

Functional magnetic resonance imaging brain mapping in psychiatry: methodological issues illustrated in a study of working memory in schizophrenia.

Functional magnetic resonance imaging (fMRI) is a potential paradigm shift in psychiatric neuroimaging. The technique provides individual, rather than group-averaged, functional neuroimaging data, but subtle methodological confounds represent unique challenges for psychiatric research. As an exemplar of the unique potential and problems of fMRI, we present a study of 10 inpatients with schizophrenia and 10 controls performing a novel "n back" working memory (WM) task. We emphasize two key design steps: (1) the use of an internal activation standard (i.e., a physiological control region) to address activation validity, and (2) the assessment of signal stability to control for "activation" artifacts arising from unequal signal variance across groups. In the initial analysis, all but one of the patients failed to activate dorsolateral prefrontal cortex (DLPFC) during the working memory task. However, some patients (and one control) also tended to show sparse control region activation in spite of normal motor performance, a result that raises doubts about the validity of the initial analysis and concerns about unequal subject motion. Subjects were then matched for signal variance (voxel stability), producing a subset of six patients and six controls. In this comparison, the internal activation standard (i.e., motor activation) was similar in both groups, and five of six patients, including two whom were neuroleptic-naive, failed to activate DLPFC. In addition, a tendency for overactivation of parietal cortex was seen. These results illustrate some of the promise and pitfalls of fMRI. Although fMRI generates individual brain maps, a specialized survey of the data is necessary to avoid spurious or unreliable findings, related to artifacts such as motion, which are likely to be frequent in psychiatric patients.

Adult↗

Determination of cerebral glucose transport and metabolic kinetics by dynamic MR spectroscopy.

A new in vivo nuclear magnetic resonance (NMR) spectroscopy method is introduced that dynamically measures cerebral utilization of magnetically labeled [1-13C]glucose from the change in total brain glucose signals on infusion. Kinetic equations are derived using a four-compartment model incorporating glucose transport and phosphorylation. Brain extract data show that the glucose 6-phosphate concentration is negligible relative to glucose, simplifying the kinetics to three compartments and allowing direct determination of the glucose-utilization half-life time [t1/2 = ln2/(k2 + k3)] from the time dependence of the NMR signal. Results on isofluorane (n = 5)- and halothane (n = 7)-anesthetized cats give a hyperglycemic t1/2 = 5.10 +/- 0.11 min-1 (SE). Using Michaelis-Menten kinetics and an assumed half-saturation constant Kt = 5 +/- 1 mM, we determined a maximal transport rate Tmax = 0.83 +/- 0.19 mumol.g-1.min-1, a cerebral metabolic rate of glucose CMRGlc = 0.22 +/- 0.03 mumol.g-1.min-1, and a normoglycemic cerebral influx rate CIRGlc = 0.37 +/- 0.05 mumol.g-1.min-1. Possible extension of this approach to positron emission tomography and proton NMR is discussed.

Animals↗

Neurochemistry of brain lesions determined by spectroscopic imaging in systemic lupus erythematosus.

OBJECTIVE: The significance and etiology of focal brain lesions in systemic lupus erythematosus (SLE) are unknown. Our purpose was to determine whether the neurochemistry of focal lesions and normal appearing brain tissues in SLE were consistent with neuronal loss, demyelination, or ischemia. METHODS: Patients with SLE (n = 14) and controls (n = 13) were studied using magnetic resonance imaging (MRI) and spectroscopic imaging (SI) at 1.5 Tesla. RESULTS: MRI detected fixed focal brain lesions (n = 16) and SI measured brain metabolites, including N-acetylaspartate (NAA), creatine (Cre), choline (Cho), and lactate (Lac). NAA/Cre of normal appearing brain was decreased in patients with SLE compared to controls: grey matter (1.74 +/- 0.16 vs 1.92 +/- 0.18; p = 0.01), occipital white matter (1.98 +/- 0.22 vs 2.23 +/- 0.16; p = 0.004), and periventricular white matter (2.00 +/- 0.23 vs 2.33 +/- 0.23; p = 0.001). Lesions were characterized by markedly decreased NAA/Cre relative to normal appearing tissues in the same patient (1.67 +/- 0.22 vs 1.88 +/- 0.14; p = 0.0002). Elevated Cho/Cre was observed in 25% of focal lesions and 21% of normal appearing tissues. No elevation of lactate was observed in lesions or normal appearing tissues. CONCLUSION: SI detects focal and generalized brain abnormalities in SLE characterized by decreased NAA, elevated choline, and normal lactate. These findings are consistent with widespread neuronal injury and demyelination, but are not consistent with anaerobic metabolism.

Adult↗

Single-shot diffusion MRI of human brain on a conventional clinical instrument.

A single-shot diffusion MRI technique on a standard clinical 1.5T scanner is presented. The method incorporates the following elements: (a) an inversion RF pulse followed by a delay of 1.3 s to null cerebral spinal fluid (CSF) signal, (b) a stimulated echo sequence (TE = 56 ms, TM = 100 ms) to obtain strong diffusion weighting, (c) a single-shot gradient- and spin-echo (GRASE) sequence for imaging with a modified k-space trajectory and Carr-Purcell Meiboom-Gill (CPMG)-phase cycle. The trace of the diffusion coefficient obtained with this approach is in good agreement with values reported for animal brain, and for recent human studies. It is demonstrated that single-shot diffusion imaging of human brain is feasible on an unmodified standard instrument without high-gradient slew rate or extreme field homogeneity.

Brain↗

Fast 3D functional magnetic resonance imaging at 1.5 T with spiral acquisition.

A new method to perform rapid 3D fMRI in human brain is introduced and evaluated in normal subjects, on a standard clinical scanner at 1.5 Tesla. The method combines a highly stable gradient echo technique with a spiral scan method, to detect brain activation related changes in blood oxygenation with high sensitivity. A motor activation paradigm with a duration of less than 5 min, performed on 10 subjects, consistently showed significant changes in signal intensity in the area of the motor cortex. In all subjects, these changes survived high statistical thresholds.

Brain↗