Search PubMed⌕ Search

Biomedical subjects

C Savage

Publications and source records attributed to C Savage.

88 records · Page 5Linked to original sources

Interleukin-8, aquaporin-1, and inducible nitric oxide synthase in smoke and burn injured sheep treated with percutaneous carbon dioxide removal.

We previously showed that a percutaneous arteriovenous gas exchanger was effective in removing CO2 and reversing respiratory failure in an ovine model of adult respiratory distress syndrome (ARDS) produced by smoke inhalation and burn injury (Alpard et al., Ann Surg 230:215-224, 1999). In this study, we tested the hypothesis that arteriovenous CO2 removal (AVCO2R) lessened endogenous inflammation in the lung. Myeloperoxidase activity, aquaporin-1 (AQP-1), interleukin-8 (IL-8), and inducible nitric oxide synthase mRNAs as well as aquaporin-1, and IL-8 protein were measured in ovine lung tissue. Lung tissue was taken at 96 h (time of sacrifice) from animals with combined smoke inhalation and 40% third degree dermal burn and subsequently treated with AVCO2R or sham (ventilator alone) after onset of ARDS (PaO2:FiO2 ratio of < 200). Myeloperoxidase activity was 1.862 +/- 0.302 U/mg protein in the ventilator group and 0.830 +/- 0.141 in the AVCO2R plus ventilator group. AQP-1 mRNA was 140,482 +/- 31,702 copies/microg total RNA in the ventilator group and 61,854 +/- 22,433 copies/microg total RNA in the AVCO2R plus ventilator group (p = 0.076). mRNA for IL-8 mRNA in the ventilator alone treated animals was 74,000 +/- 3,300 copies/microg total RNA compared to < 1,000 copies/microg total RNA in the ventilator plus AVCO2R group. This result was highly significant (p < 0.001) Inducible nitric oxide synthase mRNA was 7,853 +/- 2,229 copies/microg total RNA for the AVCO2R group and 5,854 +/- 2,070 copies/microg total RNA for the ventilator managed animals. These differences were not statistically significant (p = 0.54). Percutaneous AVCO2R produced a specific decrease in IL-8 in the smoke and burn injured animals. Furthermore, this effect was consistent with cell signaling mechanisms that increase the expression of IL-8 by cyclic stretching and the observed reduction in the number of neutrophils in the lung parenchyma. Therefore, we speculate that the mechanism by which CO2 removal exerts a beneficial effect may be due to both decreases in ventilatory requirements, with an accompanying reduction in alveolar stretching, and reduction of neutrophil numbers in lung tissue.

Animals↗

Air-borne contamination hazard in open heart surgery. Efficiency of HEPA air filtration and laminar flow.

Since 1975 we have reinforced all measures to prevent post-operative infection in open heart surgery. The environment where we worked has been gradually improved first in our old Hospital and later in the new University unit. It was, therefore, possible to relate post-operative infection to our surroundings and four groups of patients operated upon under different stages of asepsis in the operating theatre were examined. We conclude that air-borne contamination during the operation is a definite hazard, and that HEPA filtration is quite efficient in reducing this risk.

Air Microbiology↗