Search PubMed⌕ Search

Biomedical subjects

C Sachs

Publications and source records attributed to C Sachs.

At least 55 records · Page 3Linked to original sources

The exploding head syndrome: polysomnographic recordings and therapeutic suggestions.

Attention has recently been drawn to a condition termed the exploding head syndrome, which is characterized by unpleasant, even terrifying sensations of flashing lights and/or sounds during reported sleep. Nine patients complaining of sensations of explosions in the head during sleep or drowsiness were investigated with polysomnographic recordings. None of them had any neurological disorder. Five patients reported explosions during the recording sessions. According to the recordings, the attacks always took place when the patients were awake and relaxed. In two cases abrupt electroencephalographic (EEG) and electromyographic changes indicating increasing alertness were recorded at the time of the reported attacks. In the remaining three cases no EEG changes were seen. Thus, there were no indications of an epileptic etiology to the condition. In all patients the symptoms ameliorated spontaneously with time. The severity of the symptoms was reduced by reassurance of the harmlessness of the condition. Clomipramine was prescribed to three patients who all reported immediate relief of symptoms. It is concluded that symptoms of this type are probably not true hypnagogic phenomena but may be an expression of emotional stress in the awake state.

Adult↗

The sleep apnoea syndrome in obesity: risk of sudden death.

A total of 34 severely obese men with a history of heavy snoring and excessive daytime sleepiness indicative of obstructive sleep apnoea syndrome (OSAS) were studied prospectively. Their mean age was 46 years, and mean body mass index was 41.6 kg m-2. During a 4-year follow-up, 15% (5/34) of these subjects died (three cases of acute myocardial infarction and two cases of pulmonary oedema), all of them suddenly and unexpectedly, outside hospital. On autopsy the degree of atherosclerosis was found to be moderate in all cases. In 68% (15/22) of the men a pathological apnoea index (mean value 46 +/- 20) confirmed the OSAS diagnosis. Exercise tests and neurological examinations did not reveal any other causes of daytime sleepiness. Mean blood pressure at rest and during exercise was normal, and mean serum lipid and blood glucose levels were normal. Spirometry revealed intrapulmonary restrictive changes that could not be attributed to the heavy thoracic wall. Compliance was reduced to about 50% of reference values, and the mean pCO2 level (5.8 kPa) was close to the upper reference limit. Blood tests suggested that high alcohol consumption may be an important factor contributing to OSAS. These results demonstrate that morbidly obese men with a history of OSAS have a high risk of sudden cardiovascular death, despite the absence of other conventional risk factors.

Adult↗

Simulated long-term driving performance before and after uvulopalatopharyngoplasty.

To investigate whether automobile drivers with the clinical features of sleep apnea syndrome (SAS) perform worse than controls in a simulated long-term test drive, and to see if their driving improves after uvulopalatopharyngoplasty (UPPP), 15 male drivers with SAS, suffering from sleep spells whilst driving, and 10 matched controls without a history of SAS or hypersomnia at the wheel were tested in an advanced driving simulator. Brake reaction time, lateral position deviation and off-road episodes were measured during a 90-min rural drive at twilight conditions. The clinical evaluation was made by a questionnaire scoring symptoms of snoring, sleep disturbances and diurnal sleepiness before and after surgery. Before UPPP the patient group showed impaired performance in all three effect measures compared to controls. UPPP resulted in improved reaction time performance (average mean improvement: 0.5 s, average 90th percentile improvement 0.8 s). Furthermore, 12 of the 15 patients reported a marked improvement regarding sleepiness whilst driving. For these clinically successful cases the number of off-road episodes decreased substantially. We conclude that most patients improve their long-term driving performance as a result of UPPP.

Accidents, Traffic↗

Preanalytical errors in ionized calcium measurements induced by the use of liquid heparin.

The use of heparin in a liquid form to measure ionized calcium (Ca++) in plasma or whole blood can induce preanalytical errors by dilution and by changing the original Ca++ value by binding or by re-equilibration with calcium in the anticoagulant solution. To quantify these errors, Ca++ was measured on serum pools under different sampling conditions. Incomplete syringe filling and specimen volume/syringe nominal volume ratio effects were tested. Syringes were rinsed with saline to yield pure dilution effects, with sodium heparinate to study binding and with calcium-titrated heparinate to evaluate 'calcium-distortion'. Detailed tables provide percentage error values for all sampling conditions. Dilution errors could reach -5% and binding was always important (-14 to -50%). Distortion was minimal around 1.25 mmol/L but could reach -4% for high and +8% for low Ca++ values. Errors increased when syringes were not filled to their nominal volume, especially with small-sized specimens.

Anticoagulants↗

In vitro evaluation of a heparinized blood sampler for ionized calcium measurement.

When ionized calcium measurements are needed urgently blood has to be sampled with an anticoagulant to allow rapid specimen processing. Heparinate salts cause a decrease in ionized calcium by binding which is clinically significant when the concentration exceeds 15 IU/mL of whole blood. The use of an anticoagulant in an aqueous state induces 'solution-dilution' errors. To avoid these two types of error the use of calcium-titrated sodium heparinate in a dry state has been proposed. However, in this situation the actual calcium concentration could be modified if its value were different from the titration level. This possibility has been studied using a commercially available sampler (Radiometer B-129). When the sampler was used as recommended, errors were non-significant around 1.25 mmol/L. There was a +3% increase for low (0.75 mmol/L) values and a -2% decrease for high (2.50 mmol/L) values. Incomplete syringe filling increased these errors.

Calcium↗

Use of calcium-titrated sodium heparinate for ionized calcium determination on plasma and whole blood (heparinized blood sampler B-129 Radiometer).

We report modifications of ionized calcium as observed on specimens collected in a commercially available sampling device (Radiometer B-129). When the sampler is used as recommended, errors are non-significant around 1.25 mmol l-1. There is a +3% increase for low (0.75 mmol l-1) values and a -2% decrease for high (2.50 mmol l-1) values. Incomplete syringe-filling increases these errors.

Blood Specimen Collection↗

International Federation of Clinical Chemistry (IFCC) scientific division IFCC recommendation. Recommendation on sampling, transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.

The substance concentration of ionized calcium (cCa2+) in blood, plasma or serum preanalytically may be affected by pH changes of the sample, calcium binding by heparin, and dilution by the anticoagulant solution. pH changes in whole blood can be minimized by anaerobic sampling to avoid loss of CO2, by measuring as soon as possible or by storing the sample in iced water to avoid lactic acid formation. cCa2+ and pH should be determined simultaneously. Plasma or serum: if centrifuged in a closed tube and measured immediately the pH of the sample will be close to the original value. If delay has occurred between centrifugation and the measurement, causing substantial loss of CO2, equilibration of the sample with a gas mixture corresponding to PCO2 = 5.3 kPa prior to the measurement is recommended. Conversion of the measured values to cCa2+ (7.4) is only valid if the pH is in the range 7.2-7.6 Ca2+ binding by heparin can be minimized by using either of the following: a final concentration of sodium or lithium heparinate of 15 IU/ml blood or less, by use of calcium titrated heparin with a final concentration less than 50 IU/ml blood. Dilution effect can be avoided by use of dry heparin in capillaries or syringes. When heparin solutions are used errors due to dilution or calcium binding can be reduced using syringes with a heparin solution containing free calcium ions corresponding to the mean concentration of ionized calcium in normal plasma. Conditions for blood collection, storage, and transport to avoid preanalytical errors are described.

Blood Chemical Analysis↗

International Federation of Clinical Chemistry (IFCC), scientific division: IFCC recommendation on sampling transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.

The substance concentration of ionized calcium (cCa2+) in blood, plasma or serum preanalytically may be affected by pH changes of the sample, calcium binding by heparin, and dilution by the anticoagulant solution. pH changes in whole blood can be minimized by anaerobic sampling to avoid loss of CO2, by measuring as soon as possible or by storing the sample in iced water to avoid lactic acid formation. cCa2+ and pH should be determined simultaneously.

Blood Coagulation↗

Protein A-sepharose used to measure free insulin in plasma.

Diabetic patients receiving insulin therapy generally develop anti-insulin antibodies that must be eliminated, usually by extraction with polyethylene glycol (PEG), before determining the concentration of free (active) insulin in plasma. We describe a new method for removing such antibodies, with the use of Protein A coupled to Sepharose microspheres. The results correlate well with those by the PEG method, although values are systematically higher or lower for given samples, according to the initial titer of the antibody measured in terms of binding capacity. Further studies are required to clarify this observation.

Adult↗

Quantification of renal Na-K-ATPase activity by image analysing system.

The localisation of renal Na-K-ATPase activity along the rat nephron by a cytochemical method, and its quantification by an image analysis system, are described in this paper. Frozen kidney sections were exposed to a trapping agent, the lead ammoniac-citrate-acetate complex (LACA), and to all the substrates necessary to the enzyme activity. The absorbance of the histochemical reaction product (precipitated in situ), proportional to the enzymatic activity, was then measured through the analysis of the grey levels of the transmitted image of the kidney section. This method was both sufficiently sensitive and technically simple to permit measurements of the enzyme in large numbers of tubules and to determine its activity in each region of the nephron. The Na-K-ATPase activity has been determined in the proximal convoluted tubule (PCT), the medullary thick ascending limb of the Henle's loop (mTAL), and the distal convoluted tubules (DCT) of the rat nephron. The Na-K-ATPase distribution shows an activity per millimeter tubule length higher in the DCT than in the mTAL and the PCT: 1,406 +/- 33, 823 +/- 64, and 350 +/- 71 pmoles Pi/tubule mm/h, respectively. In conclusion, the described method allows the segmental quantification of Na-K-ATPase activity at a cellular level and offers a precise approach to the analysis of this enzyme along the length of nephrons.

Animals↗

Glomerular function and microalbuminuria in children with insulin-dependent diabetes.

Renal function has been evaluated in 45 diabetic children (age 12.5 +/- 4 years) with a mean diabetes duration of 4.9 +/- 3.5 years. Glomerular filtration rate (GFR; inulin and creatinine clearances), renal plasma flow (RPF; PAH clearance), resting urinary albumin excretion (UAE) were measured and compared with indexes of metabolic control: Hb A1C and blood glucose values (mean, post-prandial and maximal excursion) on the same day. GFR (inulin clearance) and RPF were significantly increased in the diabetic group (171 +/- 31 and 778 +/- 172 ml/min per 1.73 m2) compared with controls (124 +/- 18 and 631 +/- 128 ml/min per 1.73 m2). Both parameters were strongly correlated (r = 0.73; P less than 0.001). Creatinine clearance was not correlated to inulin clearance. Hyperfiltration (inulin clearance above 160 ml/min per 1.73 m2) was noted in 61% of the patients and was independent of diabetes duration. Five diabetic children had a UAE level above 15 micrograms/min. No relationship could be established between UAE and any of the metabolic indexes; GFR was weakly correlated to HbA1C (r = 0.35; P less than 0.05), to mean (r = 0.37; P less than 0.05) and post-prandial blood glucose (r = 0.37; P less than 0.05). In contrast, there was a strong correlation between GFR and the maximal blood excursion (r = 0.62; P less than 0.001). The study shows that renal abnormalities can be detected with a high frequency in diabetic subjects characterized by both an early onset and a short duration of diabetes and suggests the need for a more systematic evaluation of renal parameters in this population.

Adolescent↗

The narcolepsy-associated DRw15,DQw6,Dw2 haplotype has no unique HLA-DQA or -DQB restriction fragments and does not extend to the HLA-DP subregion.

Almost all patients with cataplectic narcolepsy are DR2-positive. It has been suggested that the non-DR2 allele/haplotype might not be neutral with respect to disease susceptibility. It has also been reported that Taq I DQA and Bam HI, Eco RI, Eco RV, and Pst I DQB restriction fragments might differentiate between narcoleptic and healthy DR2-positive individuals. In the present study, HLA class II gene polymorphisms were investigated by restriction fragment length polymorphism (RFLP) analysis in 47 Swedish patients with cataplectic narcolepsy, 100 random controls, and DR2-associated homozygous cell lines. All patients had Taq I DRB-DQA-DQB patterns corresponding to the DRw15,DQw6,Dw2 haplotype. The non-DR2 haplotype was found to be neutral. This genotyped group of patients allows firm rejection of a recessive mode of inheritance and supports a dominant or additive model. No DQA or DQB RFLPs were found that could differentiate between DR2-positive narcoleptics, DRw15,DQw6,Dw2-positive controls, or Dw2-homozygous cell lines. No significant Msp I HLA-DP association was found. No linkage disequilibrium was observed between the DRw15,DQw6,Dw2 haplotype and alleles of the DP subregion in patients or controls. Thus, the HLA-D region-associated narcolepsy susceptibility gene may be located telomeric to the HLA-DP subregion. No RFLPs have been observed that can locate the narcolepsy susceptibility gene closer to the DQ than to the DR subregion.

Genetic Linkage↗

Does Swedish amateur boxing lead to chronic brain damage? 1. A retrospective medical, neurological and personality trait study.

Sweden banned professional boxing in 1969 and has also considered banning amateur boxing. We therefore analysed possible chronic brain damage in 47 former amateur boxers who started their careers after the introduction of stricter Swedish amateur boxing rules. The boxers were compared with three control groups--25 soccer players, 25 track and field athletes and 19 conscripts. All athletes were interviewed about their sports career, medical history and social variables. They then underwent a physical and a neurological examination, including a mini-mental state examination. Personality traits were investigated and related to their platelet MAO activity in the athletes as well as in the conscripts. No significant differences were found between the groups in any of the physical or neurological examinations. All had a normal mini-mental state examination. Thus, results from these test methods did not reveal any signs of chronic brain damage from Swedish amateur boxing. Neither were any significant differences found with regard to platelet MAO activity, while significant differences were found in some of the social and personality traits variables.

Adult↗

Bioactive parathyroid hormone in pregnant rats and fetuses.

Parathyroid function at the end of gestation (day 21) was investigated by measuring plasma calcium (PCa), immunoreactive parathyroid hormone (iPTH), bioactive parathyroid hormone (bioPTH; cytochemical bioassay), and bone histology in intact and thyroparathyroidectomized (TPTX; day 12, ether anesthesia) rats and their fetuses. In pregnant intact rats, PCa was significantly lower, and iPTH, bioPTH, and osteoclast number were higher than in nonpregnant rats. In fetuses, PCa was higher than maternal PCa and correlated with fetal bioPTH. TPTX suppressed maternal bioPTH and decreased iPTH and osteoclast number, whereas fetal iPTH and bioPTH were decreased with no change in osteoclast number. Fetal PCa was near normal and was correlated with maternal PCa but not with fetal bioPTH. The fetomaternal calcium gradient was maintained and even increased. This study shows that there is maternal physiological hyperparathyroidism and functional fetal parathyroid glands at the end of gestation in the rat. Parathyroid hormone does not seem to be responsible for maintaining the high fetomaternal calcium gradient in TPTX animals.

Animals↗

Effects of acute cisplatin administration on renal ATPase activities and magnesium excretion of rats.

Male Wistar rats were killed 1, 2, or 4 days after a single intraperitoneal injection of cisplatin (5 mg/kg). Functional renal indices, enzymatic activities, and morphological variables were studied. One day after the injection, the treated group showed an increase in the magnesium and phosphate fractional urinary excretion (FE) vs the control group (FE Mg = 5.2 +/- SEM 0.5% vs 13.0 +/- 1.7%; P less than 0.01; and FE P = 4.7 +/- 0.7% vs 14.0 +/- 1.9%; P less than 0.01). Two days after cisplatin administration, a decrease in creatinine clearance of treated animals was found, to 0.33 +/- 0.03 vs 0.51 +/- 0.03 ml/min; P less than 0.05. Na-K-ATPase and ouabain-insensitive ATPase activities were studied in the proximal convoluted tubule, the medullary thick ascending limb of the Henle's loop (mTAL), and the distal convoluted tubule. Only in mTAL one day after the cisplatin injection was there a decrease in Na-K-ATPase activity in the treated group vs controls (1103 +/- 145 vs 1734 +/- 189 pmol Pi/mm.h; P less than 0.05). Morphological studies showed a decrease in mTAL diameters on day 1, and an increase in proximal convoluted tuble diameters at day 2 of treated rats vs controls, at 27.8 +/- 0.6 vs 31.4 +/- 0.7 microns; P less than 0.05, and 50.4 +/- 1.2 vs 47.4 +/- 0.2 microns; P less than 0.05 respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Triphosphatases↗

Recovery of [13C]-bicarbonate as respiratory 13CO2 in parenterally fed infants.

Ten infants on continuous total parenteral nutrition (TPN) were infused with NaH13CO3 for 6 h in order to assess the amount of 13C recovered as breath 13CO2. Protein intake was 2.8 +/- 0.3 g/kg/d and non-protein energy intake 107 +/- 4 kcal/kg/d (447 +/- 18 kJ/kg/d), provided either as glucose alone or as an isoenergetic glucose-lipid mixture. In the five infants receiving glucose as the sole non-protein energy source, total CO2 production (559 +/- 50 mumol/kg/min), natural 13C abundance of breath CO2 (-11.8 +/- 0.6 delta % versus PDB) and basal 13CO2 production (6.1 +/- 0.6 mumol/kg/min) were higher than in the five infants infused the glucose-lipid mixture (465 +/- 30 mumol/kg/min, P less than 0.02; -16.1 +/- 0.5 delta %, P less than 0.01 and 5.0 +/- 0.3 mumol/kg min, P less than 0.02, respectively). There was a good agreement, in the glucose-infused infants, between the net glucose oxidation rate measured by indirect calorimetry (25.6 +/- 2 g/kg/d) and the glucose oxidation rate estimated from the 13C natural abundances of breath CO2 and infused substrates (23.5 +/- 3 g/kg/d). Steady state 13C enrichment of breath CO2 was reached in all infants after 120 min infusion and ranged from 11.0 to 21.5 delta % over baseline. Steady state 13C enrichment was negatively related to total CO2 production (r = -0.72; P less than 0.02). In contrast, steady state 13CO2 production in excess of baseline was only correlated to bicarbonate infusion rate (r = 0.95; P less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Bicarbonates↗

Anomalies in pH 7.40 correction in ionised calcium analysers.

As a preliminary step in a study of the effects of calcium ligands on the pH standardisation of ionised calcium (Ca2+) measurement in blood, the change in Ca2+ induced by Pco2 variation was investigated in 12 serum pools on three different instruments. This type of study should yield a log Ca2+ = f(pH) linear relationship in a pH range around pH 7.40 with a slope characterising the pH-sensitive calcium buffer capacity of the specimen. The pH 7.40 correction line should be horizontal. This was the case for an ICA2 analyser but not for an ICA1 or a Nova 8 analyser. The difference was due to an incorrect setting of the built-in slope correction factor in the ICA2: fortuitously its value was close to the effective slopes of the serum pools used for the test. Thus the anomalous behaviour of the ICA1 and the Nova 8 was due to a discrepancy between the standard built-in algorithm and the characteristics of our serum pools. These findings led us to question the use of a constant correction factor to normalise actual ionised calcium values.

Autoanalysis↗

Energy substrate utilization in infants receiving total parenteral nutrition with different glucose to fat ratios.

As the fate of glucose and lipids infused during total parenteral nutrition is not well known in infants, we assessed energy substrate oxidation in 36 patients (mean age: 5.8 +/- 3.6 mo) on continuous total parenteral nutrition. The infants received isocaloric feeding regimens with nonprotein energy intakes either based on glucose alone (group 1) or on glucose-lipid mixtures providing 15% (group 2), 35% (group 3), 50% (group 4), or 70% (group 5) energy as fat for at least 6 d before glucose and fat oxidation rates were measured by open-circuit indirect calorimetry. Oxidative glucose disposal reached a maximal rate of 12.6 +/- 1.2 mg/kg.min (17.9 +/- 1.7 g/kg.d) in patients with the higher glucose infusion rates. Glucose infused in excess of maximal oxidative disposal was stored, mainly as fat. The increase in glucose infusion rate was paralleled by an increase in energy expenditure amounting to 16% of the energy value of infused glucose. Net fat oxidation was only observed in group 3 (1.6 +/- 0.7 g/kg.d), 4 (3.4 +/- 0.6 g/kg.d), and 5 (3.9 +/- 0.4 g/kg.d) patients, with glucose infusion rates lower than 18.3 g/kg.d. However, there was no further increase in fat oxidation in group 5 as compared to group 4 patients, despite a further increase in fat intake, which only resulted in increasing fat deposition. Thus, fat infusion aiming at a significant contribution to coverage of energy expenditure requires that glucose oxidation be equal to or lower than maximal oxidative glucose disposal, hence that glucose infusion rates be lower than 18 g/kg.d.(ABSTRACT TRUNCATED AT 250 WORDS)

Dietary Carbohydrates↗