Search PubMed⌕ Search

Biomedical subjects

C S Hickey

Publications and source records attributed to C S Hickey.

5 recordsLinked to original sources

Care and safety of pacemaker electrodes in intensive care and telemetry nursing units.

BACKGROUND: Temporary pacing leads with electrodes are a potential risk, because microshock inadvertently transmitted across the catheter or wire can paradoxically cause lethal dysrhythmias. Much attention has been paid to this complication in clinical guidelines, but little is known about actual practices used to protect patients. OBJECTIVES: A national survey was done to describe current practices related to the care of patients with temporary epicardial or transvenous pacing catheters. The survey focused on environmental factors that affect generation of static electricity, equipment used with temporary pacing, and nursing practices used when handling temporary pacing electrodes. METHODS: The Pacemaker Electrical Care and Safety Survey was developed, validated, and pilot tested before it was mailed to all 895 hospitals that perform cardiac surgery. Surveys were sent to the coronary care unit, cardiac surgical ICU, and telemetry units of each hospital. RESULTS: Responses were received from 476 units representing 388 (43%) of the 895 institutions. Most respondents reported using gloves, although few hospitals had policies mandating this practice. The insulating materials used most often, in order, were a glove or finger cot, tape, and gauze. Few units (25%) use any measure to reduce static electricity generated by movement over carpeting. Little attention was paid to insulating exposed epicardial temporary pacing electrodes at the generator. CONCLUSIONS: Temporary pacing electrodes were usually handled in an electrically safe manner; however, little attention was paid to environmental sources of microshock or connections between the generator and the cable. Although the respondents reported using a variety of insulating materials, the ideal cover for the exposed tips of the electrodes has not yet been determined.

Cardiac Pacing, Artificial↗

Temporary cardiac pacing.

The use of temporary cardiac pacing in critical care and stepdown units has grown tremendously over the past 10 years. While the concept of artificial pacing is simple, improvements in generator technology and lead design, along with broader clinical applications, have made temporary cardiac pacing more complex. Consequently, the critical care nurse is required to maintain an advanced level of knowledge regarding modes and complications of temporary pacing, and assessment skills related to recognizing pacemaker hemodynamic effects and pacemaker problems.

Cardiac Pacing, Artificial↗

Effects of pH shifts, bile salts, and glucose on sporulation of Clostridium perfringens NCTC 8798.

The sporulation of Clostridium perfringens NCTC 8798 was studied after exposing vegetative cells to: pH values of 1.5 to 8.0 in fluid thioglycolate broth (for 2h) and then transferring them to Duncan-Strong (DS) sporulation medium; sodium cholate or sodium deoxycholate (0.3 to 6.5 mM) in DS medium; or Rhia-Solberg medium with 0.4% (wt/wt) starch, glucose, or both added at 0 to 55 mM. At pH 1.5, no culturable heat-resistant spores were formed. For cells exposed to pH 3.0, 4.0, 5.0, or 6.0, increases in heat-resistant spores were not seen until after a lag of 12 to 13 h, whereas the lag was only 2 to 3 h for cells exposed to pH 7.0 or 8.0. Maximal spore crops were produced after only 6 to 8 h for cells exposed to pH 7 or 8, but 16 to 18 h was required for production of maximal spore crops by cells exposed to the lower-pH media. The addition of sodium cholate (3.5 to 6.5 mM) to DS medium only slightly reduced the culturable heat-resistant spore count from 1.9 X 10(7) to 3 X 10(6)/ml. The addition of 1.8 mM or more sodium deoxycholate reduced the culturable heat-resistant spore count to less than 10/ ml. When either starch or glucose alone was added to Rhia-Solberg medium there was no production of culturable heat-resistant spores, but a combination of 0.4% (wt/wt) starch and 4.4 mM glucose yielded 6 X 10(5) spores/ml. The spore production remained at this level for glucose concentrations of 6 to 22 mM, but then declined to about 3 X 10(3) spores per ml at higher concentrations.

Cholic Acids↗

System for evaluating clostridial inhibition in cured meat products.

A method for evaluating inhibition of Clostridium botulinum, C. sporogenes, and C. perfringens in cured meat products was developed. This system can easily be used in the microbiology laboratory using aluminum ointment tubes as the product container. Swells caused by gas production by the organism are easily observed by using the aluminum tubes. Results obtained confirmed earlier work on the inhibitory effect of sodium nitrite and sorbic acid against the clostridia in cured meat products.

Animals↗

Infection precautions with temporary pacing leads: a descriptive study.

OBJECTIVE: To describe infection precautions used by nurses when caring for patients with temporary epicardial and transvenous pacemakers. DESIGN: Descriptive, nation-wide survey. SETTING: All U.S. hospitals performing cardiac surgery. RESPONDENTS: Nurse managers and clinical specialists from cardiac and thoracic intensive care, coronary care, and telemetry units at all U.S. hospitals performing cardiac surgery. INTERVENTION: The Pacemaker Electrode Care and Safety Survey. RESULTS: Responses came from 43% (388) of the 895 hospitals. Most respondents indicated that they wore gloves when handling electrodes (approximately 96%); usually the gloves were nonsterile (73%). A sterile procedure was often used to perform site care (37% for epicardial and 65% for transvenous). The most common agent used for site cleansing was povidone-iodine. Concern has been expressed in the literature about use of this agent. Gauze was the most common type of dressing (used by 60% for epicardial dressings and 31% for transvenous). CONCLUSION: There is diversity in clinical practice. Further study is recommended to establish the safety, efficacy, and cost-effectiveness of identified infection precautions.

Bandages↗