Search PubMed⌕ Search

Biomedical subjects

C R Meyer

Publications and source records attributed to C R Meyer.

119 records · Page 7Linked to original sources

Breast imaging in coronal planes with simultaneous pulse echo and transmission ultrasound.

Clear delineation of breast architecture was achieved with compound pulse echo ultrasound imaging in which the images were acquired in the coronal planes used for quantitative transmission ultrasonic computed tomography. Since most connective tissue planes in the breast radiate toward the nipple, compound scans from the sides of the breast record normal interfaces more consistently and reveal greater symmetries in normal portions of relatively full breasts than do conventional scans in sagittal or transverse planes. Simultaneous acquisition of the pulse echo images and images representing the local ultrasound attenuation coefficient and speed of ultrasound suggested complementary role for reflection and through-transmission images in breast cancer detection. The high quality of pulse echo images in coronal planes provides the potential for more complete pulse echo diagnosis and the basis for spatial correlation of lesions viewed in pulse echo and ultrasonic computed tomograms. These observations may permit routine ultrasonic computed tomography of the breast in the clinical setting.

Breast↗

Effects of irradiance on relative growth rates, net assimilation rates, and leaf area partitioning in cotton and three associated weeds.

Cotton (Gossypium hirsutum L. var. ;Stoneville 213'), velvetleaf (Abutilon theophrasti Medic.), redroot pigweed (Amaranthus retroflexus L.), and hemp sesbania (Sesbania exaltata [Raf.] Cory) were grown in a controlled environment room at 31/25 C day/night temperature and three irradiances: 90, 320, and 750 mueinsteins meter(-2) second(-1). From total dry weights and leaf areas determined at intervals during the first exponential phase of growth, we used mathematical growth analysis techniques to calculate net assimilation rates (NAR), relative growth rates (R(w)), relative leaf area expansion rates (R(a)), leaf area partition coefficients (LAP), and leaf area ratios (LAR). In all four species, R(w), R(a), and NAR decreased with decreasing growth irradiance, while LAP and LAR increased. Within each species, R(w) was positively correlated with NAR but negatively correlated with LAP and LAR. In comparisons among the four species within each growth irradiance, R(w) was positively correlated with LAP. We discuss the relationship between LAP and LAR and show that LAP = (R(a)/R(w)) (LAR).

Journal Article↗

An environmental health survey of drinking water contamination by leachate from a pesticide waste dump in Hardeman County, Tennessee.

Ground water that was used as a source of potable water by residents of a small community became contaminated by leachate from a 300,000 barrel pesticide waste dump. An environmental health survey of the residents and an apparent control group was conducted to determine if any adverse health effects resulting from exposure to the toxic compounds, many of which were hepatotoxins, could be detected. The survey utilized a health questionnaire, a clinical examination, and a biochemical screening. The latter included analysis of serum for liver and kidney function parameters, determination of hepatitis A and B serology, and bile acid determinations on fasting and postprandial serum and urine specimens. Air and water from representative homes and urine from study participants were analyzed for selected organic compounds. The biochemical screening was conducted on two occasions 2 months apart. The initial hepatic profile testing revealed elevated concentrations of the serum enzymes, alkaline phosphatase and serum glutamic oxaloacetic transaminase, in residents who had used the contaminated water. During follow-up testing of these same persons 2 months later, these values were significantly reduced, as were postprandial serum concentrations of the bile acid of cholyglycine. Six individuals in the exposed group had slight hepatomegaly compared to one individual in the intermediate exposure group and none in the controls. Concentrations of carbon tetrachloride were as high as 18,700 microgram/L in the well water samples. The biochemical and clinical observations are suggestive of a transitory liver injury probably related to exposure to the contaminated drinking water.

Adolescent↗

Sonographic identification of lung maturation in the fetal lamb.

Ultrasound evaluation of fetal lung development in utero could be a noninvasive method for frequent monitoring of the state of pulmonary maturity and predicting when parturition could occur with minimum or no risk of respiratory distress syndrome of the newborn. In cases of high-risk obstetric management in premature labor, this ability may be a particularly useful tool. To pursue this possibility, the lungs and livers of 13 living fetal lambs were successfully imaged with a modified clinical B-scanner under carefully controlled conditions; physiologic function tests on the excised lungs determined the state of pulmonary maturity. In eight cases, maturity or immaturity was correctly identified by sonographic criteria. The results wer ambiguous in four cases. One case of immature lung was incorrectly identified as mature. The trends established in these animal studies appear promising and with refinement may form the basis for sonographic assessment of fetal lung maturity in a clinical setting.

Animals↗

Determination of liver volume from CT scans using histogram cluster analysis.

The histogram cluster analysis procedure (HICAP), which was developed by NASA for processing satellite images, classifies images into discrete clusters of pixels according to one or more arbitrary imaging variables. We incorporated this nonparametric, multivariate procedure in a semiautomatic computer algorithm for calculating total liver volume from CT scans and compared its performance with that of a human observer. Total liver volumes were calculated from CT scans in adult patients by the algorithm and by an experienced radiologist using the trackball controlled cursor at the CT console. Variability in the computer calculated volumes was determined by repeating calculations three times over the course of 3-12 months. Using HICAP in the univariate mode, we calculated total liver volumes from 28 contrast enhanced CT scans in 27 patients. Liver volumes calculated by the semiautomatic and manual methods had a median absolute difference of 3.6% (Vcomputer = 1.08 * Vmanual - 99.52 cc; r2 = 0.99). Median day-to-day variability of the computer calculated volumes was 1.9% (95% confidence interval: 1.3-2.7%). Using HICAP in a bivariate mode to illustrate its ability to incorporate two image features in one analysis, we studied an additional patient and compared total liver volume calculated from the univariate data set defined by the contrast enhanced CT scan with that calculated from the bivariate data set defined by nonenhanced and contrast enhanced CT scans. The HICAP errors were 4.1% in the univariate analysis and 0.4% in the bivariate analysis. It is concluded that this statistical clustering algorithm provides a clinically accurate, repeatable, and feasible method of in vivo liver volume determination.

Adult↗

Median and spatial low-pass filtering in ultrasonic computed tomography.

To reduce noise- and reconstruction-related artifacts in ultrasound computed tomography, the use of combined median and Hamming-weighted spatial low-pass filtering is evaluated. The evaluation of the reconstruction filters uses both computer-generated projections of a known object with the least mean-square error criterion as well as a more subjective evaluation of conventional ultrasonic attenuation and speed of sound images.

Breast↗

Bulk flow model for multislice magnetic resonance imaging sequences with phantom validation.

A simple conceptual model for describing the effects of one-dimensional bulk flow on image intensities is presented and validated using a multislice imaging sequence specific to one vendor. The model allows quantitative estimates of echo amplitudes versus velocity by using the equation of motion to follow the pulse history of fluid volumes influenced by the readout pulse for any slice of interest. Each affected volume is divided into equal elemental components and the state of each component is computed at discrete times in a pulse position-timing diagram until readout occurs. The final amplitude for the composite volume is determined by the signed summation of each of the elemental components. Validation of the quantitative model was performed by imaging a rotating bulk flow phantom centered at each of the slices of a multislice, partial saturation, spin-echo sequence. Effects due to rf field inhomogeneities were normalized by dividing the results of the dynamic scans by the corresponding static one. The results presented here are relatively insensitive to odd-echo dephasing (even echo rephasing).

Humans↗