Search PubMed⌕ Search

Biomedical subjects

C R Clark

Publications and source records attributed to C R Clark.

At least 19 recordsLinked to original sources

The test-retest reliability of a standardized neurocognitive and neurophysiological test battery: "neuromarker".

NeuroMarker combines EEG and ERP measures with neurocognitive tests in a fully computerized and standardized testing system. It is designed for use across the lifespan and has a large normative database of over 1,000 subjects. This study was a preliminary evaluation of "NeuroMarker" in subjects spanning four decades. Twenty-one healthy subjects (12-57 years) were tested at baseline and four weeks later. From the "Neuromarker" battery, the authors analyzed EEG data (eyes open and closed) and ERPs elicited during auditory oddball (N100, P200, N200, P300) and working memory (P150, P300) tasks. Concomitant neuropsychological data, acquired using a touch-screen system, comprised measures of sensori-motor, attention, verbal, executive, and memory function. Test-retest data were examined using analyses of variance and correlational procedures (corrected for multiple comparisons), with parallel analyses of age. EEG data did not differ across sessions, and showed high test-retest reliability (.71-.95), particularly for theta and delta (>.85). ERP components also showed sound reliability, particularly for sites where components are maximal: fronto-central N100 (.76-.77), centro-parietal P300 (.78-.81) to oddball targets, N100 and P200 (.74-.86) to oddball non-targets, and P150 amplitude and latency (.84-.93) to working memory stimuli. Neuropsychological tests showed a similarly sound level of consistency (on average, .70), with the most consistent tests tapping simple motor function, estimated intelligence, switching of attention (Part 2), verbal interference response time and memory intrusions (.71-.89). Age and sex did not have a differential impact on reliability for EEG, ERP, or neuropsychology measures. These findings provide preliminary evidence that the "NeuroMarker" battery is reliable for test-retest assessments. The results suggest that the standardized approach has utility for providing sensitive clinical and treatment evaluations across age groups.

Adolescent↗

Cognitive tasks augment gamma EEG power.

OBJECTIVE: Gamma EEG oscillations are low amplitude rhythms in the 30-100 Hz range that correlate with cognitive task execution. They are usually reported using time-locked averaging of EEG during repetitive tasks. We tested the hypothesis that continuous gamma EEG would be measurable during mental tasks. METHODS: We investigated sustained human gamma EEG oscillations induced by 8 cognitive tasks (Visual Checkerboard, Expectancy, Reading, Subtraction, Music, Expectancy, Word learning, Word recall, and a Video Segment) in 20 subjects using standard digital EEG recording and power spectral analysis. RESULTS: All of the cognitive tasks augmented gamma power relative to a control condition (eyes open watching a blank computer screen). This enhancement was statistically significant at more than one scalp site for all tasks except checkerboard. The Expectancy, Learning, Reading and Subtraction tasks expressed the most impressive gamma response, up to 5 fold above the control condition and there was some task-related specificity of the distribution of increased gamma power, especially in posterior cortex with visual tasks. CONCLUSIONS: Widespread gamma activation of cortical EEG can easily be demonstrated during mental activity. SIGNIFICANCE: These results establish the feasibility of measuring high frequency EEG rhythms with trans-cranial recordings, demonstrate that sustained gamma EEG activity correlates with mentation, and provides evidence consistent with the temporal binding model.

Adult↗

Operative treatment of cervical spondylotic myelopathy and radiculopathy. A comparison of laminectomy and laminoplasty at five year average follow-up.

BACKGROUND: The natural history of cervical spondylotic myelopathy is frequently one of slow, progressive neurological deterioration. The operative treatment for patients with moderate to severe involvement is decompression of the spinal cord. Laminectomy has been a traditional approach and laminoplasty has developed as an attractive alternative. The purpose of this study was to examine and compare the outcomes of these two procedures in similar groups of patients at a five year average follow-up. METHODS: A consecutive series of twenty patients who underwent open-door laminoplasty for multi-level cervical spondylotic myelopathy or radiculopathy was compared to a similar group of 22 matched patients who underwent multi-level laminectomies. Patients were similar in age, gender, number of operative levels, and length of follow-up. At the latest examination, each patient underwent a comprehensive neurological evaluation. A modification of the Nurick classification was used to assess the degree of myelopathy. Radiographs at latest follow-up were assessed for instability, and measurements of the space-available-for-the-cord and Pavlov ratio were made at involved levels. RESULTS: Myelopathy, as determined by our modified Nurick scale, improved from a preoperative average of 2.44 to 1.48 in laminoplasty patients and from an average of 3.09 to 2.50 in laminectomy patients. Pain improved 57 percent and 8 percent in laminoplasty and laminectomy groups, respectively. Subjective neck stiffness was not significantly different based on the numbers available, although laminoplasty patients demonstrated some loss of range of motion on examination. The only variable that predicted the postoperative degree of myelopathy in both groups was the preoperative degree of myelopathy. CONCLUSIONS: Laminectomy and laminoplasty patients demonstrated improvements in gait, strength, sensation, pain, and degree of myelopathy. Laminoplasty was associated with fewer late complications. Based on this analysis, we believe that laminoplasty is an effective alternative to laminectomy in patients with multi-level cervical spondylotic myelopathy or radiculopathy.

Adult↗

Persistent abnormality detected in the non-ictal electroencephalogram in primary generalised epilepsy.

OBJECTIVES: Gamma oscillations (30-100 Hz gamma electroencephalographic (EEG) activity) correlate with high frequency synchronous rhythmic bursting in assemblies of cerebral neurons participating in aspects of consciousness. Previous studies in a kainic acid animal model of epilepsy revealed increased intensity of gamma rhythms in background EEG preceding epileptiform discharges, leading the authors to test for intensified gamma EEG in humans with epilepsy. METHODS: 64 channel cortical EEG were recorded from 10 people with primary generalised epilepsy, 11 with partial epilepsy, and 20 controls during a quiescent mental state. Using standard methods of EEG analysis the strength of EEG rhythms (fast Fourier transformation) was quantified and the strengths of rhythms in the patient groups compared with with controls by unpaired t test at 1 Hz intervals from 1 Hz to 100 Hz. RESULTS: In patients with generalised epilepsy, there was a threefold to sevenfold increase in power of gamma EEG between 30 Hz and 100 Hz (p<0.01). Analysis of three unmedicated patients with primary generalised epilepsies revealed an additional 10-fold narrow band increase of power around 35 Hz-40 Hz (p<0.0001). There were no corresponding changes in patients with partial epilepsy. CONCLUSIONS: Increased gamma EEG is probably a marker of the underlying ion channel or neurotransmitter receptor dysfunction in primary generalised epilepsies and may also be a pathophysiological prerequisite for the development of seizures. The finding provides a new diagnostic approach and also links the pathophysiology of generalised epilepsies to emerging concepts of neuronal correlates of consciousness.

Adult↗

A finite element investigation of upper cervical instrumentation.

STUDY DESIGN: The finite element technique was used to predict changes in biomechanics that accompany the application of a novel instrumentation system designed for use in the upper cervical spine. OBJECTIVE: To determine alterations in joint loading, kinematics, and instrumentation stresses in the craniovertebral junction after application of a novel instrumentation system. Specifically, this design was used to assess the changes in these parameters brought about by two different cervical anchor types: C2 pedicle versus C2-C1 transarticular screws, and unilateral versus bilateral instrumentation. SUMMARY OF BACKGROUND DATA: Arthrodesis procedures can be difficult to obtain in the highly mobile craniovertebral junction. Solid fusion is most likely achieved when motion is eliminated. Biomechanical studies have shown that C1-C2 transarticular screws provide good stability in craniovertebral constructs; however, implantation of these screws is accompanied by risk of vertebral artery injury. A novel instrumentation system that can be used with transarticular screws or with C2 pedicle screws has been developed. This design also allows for unilateral or bilateral implantation. However, the authors are unaware of any reports to date on the changes in joint loading or instrumentation stresses that are associated with the choice of C2 anchor or unilateral/bilateral use. METHODS: A ligamentous, nonlinear, sliding contact, three-dimensional finite element model of the C0-C1-C2 complex and a novel instrumentation system was developed. Validation of the model has been previously reported. Finite element models representing combinations of cervical anchor type (C1-C2 transarticular screws vs. C2 pedicle screws) and unilateral versus bilateral instrumentation were evaluated. All models were subjected to compression with pure moments in either flexion, extension, or lateral bending. Kinematic reductions with respect to the intact (uninjured and without instrumentation) case caused by instrumentation use were reported. Changes in loading profiles through the right and left C0-C1 and C1-C2 facets, transverse ligament-dens, and dens-anterior ring of C1 articulations were calculated by the finite element model. Maximum von Mises stresses within the instrumentation were predicted for each model variant and loading scenario. RESULTS: Bilateral instrumentation provided greater motion reductions than the unilateral instrumentation. When used bilaterally, C2 pedicle screws approximate the kinematic reductions and instrumentation stresses (except in lateral bending) that are seen with C1-C2 transarticular screws. The finite element model predicted that the maximum stress was always in the region in which the plate transformed into the rod. CONCLUSIONS: To the best of the authors' knowledge, this is the first report of predicting changes in loading in the upper cervical spine caused by instrumentation. The most significant conclusion that can be drawn from the finite element model predictions is that C2 pedicle screw fixation provides the same relative stability and instrumentation stresses as C1-C2 transarticular screw use. C2 pedicle screws can be a good alternative to C2-C1 transarticular screws when bilateral instrumentation is applied.

Biomechanical Phenomena↗

The effectiveness of very short scales for depression screening in elderly medical patients.

OBJECTIVE: To compare very short scales for screening for depression with longer, widely used scales. METHODS: Eighty-seven patients over the age of 60 who were admitted to rehabilitation wards or were attending a day rehabilitation facility at a British teaching hospital were screened for depression using the 1-item mental health inventory, and the 4-item, 15-item and 30-item geriatric depression scales. The sensitivity, specificity, and areas under receiver operating characteristic curves were compared, with the diagnostic criteria for research of ICD-10 providing the criterion diagnosis of depressive episode. RESULTS: All the scales had comparable sensitivity (82.4-100%), specificity (60.0-71.4%), and positive predictive values (33.3-42.9%). Comparison of receiver operating characteristic curves for each scale showed no statistically significant difference between them (range 0.80-0.88). CONCLUSIONS: The very short scales performed just as well as the widely used longer screening scales in this population. They are worthy of further examination in elderly populations at risk of depression, and may be particularly suitable for older adults due to their brevity and ease of use.

Aged↗

Cortical network dynamics during verbal working memory function.

This study is an exploratory investigation of the regional timing of cortical activity associated with verbal working memory function. ERP activity was obtained from a single subject using a 124-channel sensor array during a task requiring the monitoring of imageable words for occasional targets. Distributed cortical activity was estimated every 2.5 ms with high spatial resolution using real head, boundary element modelling of non-target activity. High-resolution structural MRI was used for segmentation of tissue boundaries and co-registration to the scalp electrode array. The inverse solution was constrained to the cortical surface. Cortical activity was observed in regions commonly associated with verbal working memory function. This included: the occipital pole (early visual processing); the superior temporal and inferior parietal gyrus bilaterally and the left angular gyrus (visual and phonological word processing); the dorsal lateral occipital gyrus (spatial processing); and aspects of the bilateral superior parietal lobe (imagery and episodic verbal memory). Activity was also observed in lateral and superior prefrontal regions associated with working memory control of sensorimotor processes. The pattern of cortical activity was relatively stable over time, with variations in the extent and amplitude of contributing local source activations. By contrast, the pattern of concomitant scalp topography varied considerably over time, reflecting the linear summation effects of volume conduction that often confound dipolar source modelling.

Adult↗

Working memory in posttraumatic stress disorder--an event-related potential study.

This study examined ERP topography during the updating and the utilization of working memory in subjects with PTSD. Event-related potentials of 18 participants with PTSD and 18 controls were recorded from 32 scalp electrodes during an auditory target detection task requiring the constant updating of target identity. Midline N2 and P3 abnormalities previously noted in PTSD during target detection were replicated. Scalp topographic data revealed sustained reduction in activity over the right hemisphere during working memory updating. Executive processes were associated with brief but widespread right hemisphere reductions during the P3, followed by sustained, bilateral reduction frontally. This study identifies an abnormal pattern of cortical network function during both the updating and use of working memory in PTSD.

Adult↗

The Knee Society Index of Severity for failed total knee arthroplasty: development and validation.

Compared with primary knee replacement, total knee arthroplasty revision surgery is a more complex procedure and accounts for greater expenditures of healthcare resources at each clinical stage. Overall, patients having revision procedures have poorer functional outcomes and higher complication rates than patients having primary arthroplasty. Despite the expanded scope of revision problems and the rapidly emerging technology in revision surgery, the long-term success of any method remains in question. Because there is little consensus on the timing of revision surgery, optimal surgical reconstruction, and the type of prosthesis to be implanted, the Knee Society began development of an Index of Severity for Failed Total Knee Arthroplasty. Fifty-four percent of Knee Society members completed an 82-item questionnaire that determined their clinical impression about potential risk factors for the outcomes of revision surgery for failed total knee replacements. Using these results, a consensus group developed the final version of the index. The result of the nominal group process was the Knee Society Index of Severity, which was based on eight distinct domains. Each domain was divided into attributes and weights based on the questionnaire responses and consensus meeting. Actual case scenarios from five institutions were used to test interrater reliability and validity. The interrater reliability of the average score of all ratings was 0.95; the correlation of the criterion rating with the mean rating was 0.77. When three outliers were not included, the Pearson product correlation increased to 0.92. These data support the application of the Knee Society Index of Severity as a critical component of risk factor studies, effectiveness research, and cost-effectiveness analysis involving revisions of total knee replacements.

Arthroplasty, Replacement, Knee↗

The Knee Society Index of Severity for failed total knee arthroplasty: practical application.

Previous classifications of severity for total knee arthroplasty revisions have been based largely on bone loss of the femur and tibia. These approaches failed to address the more technically difficult issues in revision surgery such as surgical exposure, contractures, extremity alignment, implant removal, soft tissue stability (in the anteroposterior and in the sagittal planes), extensor mechanism integrity, and patellar revisability. Through the Knee Society, the authors developed a severity index that incorporated these latter factors into one measure. The current authors describe the application of the Knee Society Index of Severity for failed total knee arthroplasty and its method of scoring.

Arthroplasty, Replacement, Knee↗

Posterior-stabilized and cruciate-retaining total knee replacement: a randomized study.

A randomized controlled study was done to compare the clinical, radiographic, and quality of life outcomes between posterior-stabilized and cruciate-retaining primary total knee implants. One hundred forty-three patients were enrolled in the study. Patients ranged in age from 57 to 89 years, had a primary diagnosis of osteoarthritis, and an intact functioning posterior cruciate ligament. Patients were excluded if they had a flexion contracture greater than 15 degrees, a varus deformity greater than 20 degrees, or a valgus deformity greater than 15 degrees. Patients were randomized to one of two study groups, posterior-stabilized AMK total knee implants (76 patients) or cruciate-retaining AMK total knee implants (67 patients). One hundred eight patients have had a minimum 2-year followup including 57 patients in the posterior-stabilized group and 51 patients in the cruciate-retaining group. Seventy-three patients have had a minimum 3-year followup including 37 patients in the posterior stabilized group and 36 patients in the cruciate-retaining group. The overall total Knee Society clinical rating score at 2 years averaged 157.1 points in the posterior-stabilized group and 156.5 points in the cruciate-retaining group. At 3 years, the scores averaged 156.8 points in the posterior-stabilized group and 163.5 points in the cruciate-retaining group. The range of motion component of the Knee Society score averaged 113.6 degrees for the posterior-stabilized group and 108.5 degrees for the cruciate-retaining group at 2 years, and 108.3 degrees in the cruciate-retaining group and 108.5 degrees in the posterior-stabilized group. Based on the various parameters analyzed, there were no notable differences between the groups with a posterior-stabilized and a cruciate-retaining total knee implant at 2 years. This trend seemed to be the same at 3 years.

Aged↗

Pathomechanisms of failures of the odontoid.

STUDY DESIGN: A finite element investigation to determine the causal mechanisms that lead to odontoid fracture. OBJECTIVES: To elucidate which loading scenarios, including rotational moments, compression-tension, and lateral and anteroposterior shear, can result in Type I, Type II, and Type III odontoid failures. SUMMARY OF BACKGROUND DATA: There is considerable controversy about the major loading path that causes odontoid fractures. A review of the clinical and laboratory research literature did not provide a consensus on this issue. METHODS: A three-dimensional, nonlinear finite element model of the occipito-atlantoaxial (C0-C1-C2) complex was generated from human cadaveric data. Force loads were applied at the posterior margin of the occiput and were applied as lone entities or after the model was prepositioned in flexion, extension, or lateral-bending moments through applied rotation moments. Intraosseous stresses were reported to characterize the probability of fracture due to the applied loadings. RESULTS: The data indicate that hyperextension can lead to failure of the odontoid at its superior tip (Type I). Finite element model predictions also demonstrated the propensity of loads that induce axial rotation to create relatively high maximum von Mises stress in the Type II fracture region. Flexion prepositioning reduced the stress response of the odontoid. CONCLUSIONS: Force loading that puts the head in extension coupled with lateral shear or compression leads to Type I fractures, whereas axial rotation and lateral shear can produce Type II fractures. The model failed to elucidate causal mechanisms for Type III fractures. Flexion seems to provide a protective mechanism against force application that would otherwise cause a higher risk of odontoid failure.

Atlanto-Occipital Joint↗