Left atrial appendage myopathy: the importance of serial transesophageal assessment in atrial fibrillation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C Pollick.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: The efficacy of three different echocardiographic techniques to assess cardiac structures and function in the rat heart was studied. BACKGROUND: With increasing costs for large animal studies there is need for improved assessment of ventricular function in small animal models. METHODS: Transthoracic, transesophageal, or intracavitary echocardiography was performed in 138 rats using either a pediatric or an intravascular ultrasound transducer in control, infarcted, and obese rats. Left ventricular dimensions and wall thickness were measured. RESULTS: Transthoracic echocardiography allows qualitative and quantitative estimation of cardiac dimensions and ventricular function. End-diastolic and end-systolic diameters were 0.53 +/- 0.08 and 0.26 +/- 0.05 cm in controls, 0.63 +/- 0.08 and 0.41 +/- 0.07 cm in infarcted (p < 0.001 vs controls), and 0.66 +/- 0.1 and 0.21 +/- 0.07 cm in obese rats (p < 0.01 vs controls). Fractional shortening was 52 +/- 6% in controls, 36 +/- 5% in infarcted (p < 0.001), and 68 +/- 9% in obese rats (p < 0.001). Wall thickness was increased in obese rats. Transesophageal echocardiography allows a qualitative rather than quantitative assessment. Intracavitary ultrasound enabled visualization of the endocardium. Following coronary occlusion, fractional shortening and ejection fraction were decreased (30.8 +/- 4.5 vs 44.4 +/- 4.7%, p < 0.005, and 46.7 +/- 8.5 vs 63.4 +/- 5.4%, p < 0.005, respectively). CONCLUSIONS: Transthoracic echocardiography is a non-invasive technique to sufficiently provide information about cardiac structures and function, while transesophageal echocardiography allows rather a qualitative estimation of the rat heart. Intracavitary ultrasound can be used to assess the endocardium, ventricular function, and dimensions in open-chest studies in rats.
BACKGROUND: Costs for large animal studies have escalated. Therefore there is a need to develop small animal models of non-ischemic cardiac failure and accurate non-invasive techniques that will allow serial quantitation of left ventricular function. OBJECTIVES: The purpose of our study was to determine the efficacy and reliability of adriamycin for inducing cardiomyopathy in rats. We hypothesized that high frequency transthoracic 2-dimensional and M-mode echocardiography would allow for serial testing of cardiac function in this small animal model. METHODS: Adriamycin was administered at a dose of 2.5 mg/kg intravenously once a week for 10 weeks in 54 rats. Transthoracic echocardiography by use of a 7.5 MHz transducer was performed in 19 rats at baseline and additionally at 12 weeks after beginning of adriamycin therapy to measure left ventricular dimensions and calculate fractional shortening. RESULTS: The mortality rate during the treatment period was 11%, but increased to 52% at 13 weeks. Transthoracic echocardiography provided adequate visualization of left ventricular dimensions and cardiac function in a parasternal short axis view. In follow-up echocardiography, pericardial effusion was detected in 8/19 rats (42%). Compared to baseline, end-diastolic diameters increased from 0.56 +/- 0.06 to 0.64 +/- 0.08 mm (p < 0.001), end-systolic diameters increased from 0.27 +/- 0.03 to 0.42 +/- 0.08 mm (p < 0.001), and fractional shortening decreased from 52.8 +/- 4.0 to 34.3 +/- 7.1% (p < 0.001) at 12 weeks. Electron microscopy in a subset of rats revealed cardiomyocyte degeneration, mitochondrial and sarcoplasmatic reticular edema, numerous intracellular vacuoles and 'onion-ring' shaped mitochondrial cristae, characteristic for adriamycin cardiotoxicity in human patients. CONCLUSION: Adriamycin at an intravenous dose of 2.5 mg/kg over 10 weeks can be used to create a reliable model of non-ischemic dilated cardiomyopathy with a high success rate. For in-vivo diagnostic purposes, transthoracic echocardiography provides a reliable technique to non-invasively assess cardiac function quantitatively and qualitatively in follow-up studies in rat cardiomyopathy. This small animal model can easily be used for testing new therapeutic strategies in cardiac failure.
OBJECTIVES: We studied the use of esmolol in patients experiencing minor side effects of palpitations, anxiety, nervousness, and tremors associated with dobutamine stress echocardiography. BACKGROUND: Dobutamine stress echocardiography is frequently used in the assessment of coronary artery disease. Esmolol administration may enhance patient comfort. METHODS: Sixty consecutive patients who experienced minor side-effects during dobutamine stress echocardiography were given 0.3 mg/kg esmolol intravenously in the recovery period and compared retrospectively to sixty consecutive controls who underwent dobutamine stress echocardiography, who did not receive esmolol, during the same time period. Both groups were matched for age, ejection fraction, and peak dose of dobutamine. Heart rate and blood pressure were assessed during and after dobutamine administration. RESULTS: Both groups had similar baseline blood pressure (mmHg) (142 +/- 19/72 +/- 14 vs 139 +/- 20/72 +/- 14) and heart rate (beats per minute) (75 +/- 14 vs 75 +/- 17) (esmolol and control respectively, p = ns), but peak heart rate was higher in the esmolol group (126 +/- 14 vs. 116 +/- 14, p < 0.01). In the group who received esmolol, symptomatic relief paralleled the statistically significant decrease in heart rate which occurred within 1 minute of esmolol administration (99.7 +/- 15.3 vs 108.5 +/- 13.1 p < 0.0001); the heart rate in the esmolol group remained significantly lower than the control group for 5 minutes following esmolol administration (92.0 +/- 10.3 vs 96.7 +/- 11.8 p < 0.05). As a percentage of peak heart rate the esmolol group remained significantly lower than the control for 7 minutes (74% vs 80% p < 0.05). Esmolol induced a significant reversal of dobutamine-induced diastolic hypotension (diastolic blood pressure at peak 66 +/- 17 vs 8 min recovery 70 +/- 12, p < 0.03) that was not seen in controls (diastolic blood pressure at peak 64 +/- 18 vs 8 min recovery 65 +/- 14, p = ns). Systolic blood pressure and heart rate remained elevated in both groups 8 min into recovery compared to baseline, suggesting persistent dobutamine effect beyond the expected 2 min pharmacologic half-life of dobutamine. No side-effects from esmolol were seen despite it being used in 9 patients with EF < 35%. CONCLUSIONS: Esmolol is effective and well tolerated for the management of dobutamine-related minor side-effects. The mechanism of benefit, in addition to heart rate reduction, may involve a reversal of dobutamine-induced diastolic hypotension. Blood pressure and heart rate recovery are slower than expected from previously published pharmacokinetic data.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Three illustrative cases of refractory hypoxemia in adults are presented. In two cases contrast echocardiography was invaluable in establishing the diagnosis of a true anatomic right to left shunt, as well as in localizing the shunt to an intracardiac or extracardiac site. In the third case true anatomic right to left shunt was excluded by means of contrast echocardiography. The pathophysiology of hypoxemia is discussed with emphasis on the potential diagnostic utility of contrast echocardiology in patients with refractory hypoxemia. A diagnostic flow chart is proposed.
OBJECTIVES: We postulated that femoral vein delivery of contrast medium because of streaming, might enhance precordial echocardiographic detection of patent foramen ovale. BACKGROUND: Although precordial contrast echocardiography is widely used to diagnose patent foramen ovale, this method is limited by poor sensitivity. Previous investigators have demonstrated enhanced detection of atrial defects by the dye-dilution technique after delivery of contrast medium into the inferior rather than the superior vena cava. METHODS: Transthoracic contrast examinations were performed in a randomly selected group of 70 patients (without previous history of cerebral or systemic embolus) undergoing cardiac catheterization. Paired contrast agent injections (10 ml dextrose in water/0.25 ml air) were administered from an upper extremity vein and femoral vein in each patient during spontaneous respiration, cough and Valsalva maneuvers. Studies were interpreted by an experienced echocardiographer unaware of the sequence and site of injections. Positive studies were semiquantitatively graded from +1 (minimal left ventricular opacification) to +4 (intense left ventricular opacification). Catheterization and echocardiographic assessment of patent foramen ovale were compared in 21 subjects. RESULTS: Patent foramen ovale was detected significantly more often during femoral vein versus upper extremity contrast delivery (23 of 70 patients [prevalence 33%] vs. 9 of 70 patients [prevalence 13%], p < 0.001). The intensity of left ventricular opacification was also greater during femoral vein contrast injection. Precordial echocardiography combined with femoral contrast delivery was significantly more sensitive than cardiac catheterization for assessment of patent foramen ovale (8 of 21 patients vs. 2 of 21 patients, p < 0.05). CONCLUSIONS: Femoral vein contrast delivery significantly enhances the ability of precordial contrast echocardiography to diagnose patent foramen ovale. Physiologic patency of the foramen ovale is more common (prevalence 33%) than previously documented.
Thousands of coronary bypass operations are performed in Canada each year. Some result in longer life or improved quality of life by reducing angina, but others do not. Where the potential benefit is unknown, physicians must consider the patient's work, home life, and personality. Clinical intuition is still needed to determine which patients will benefit.
OBJECTIVE: To investigate the diagnostic accuracy, electrocardiogram and hemodynamic effects and safety of dobutamine stress echocardiography. SUBJECTS: Sixty-one patients with suspected coronary artery disease. All patients underwent coronary arteriography. MAIN RESULTS: The sensitivity of dobutamine stress echocardiography in diagnosis of coronary artery disease in the whole group was 91%. In patients with left anterior descending it was 97%; right 85%; circumflex 76%; three vessel 100%; two vessel 95%; single vessel 77%. Specificity, positive predictive value and accuracy of dobutamine stress echocardiography in diagnosis of coronary disease (whole group) was 57, 94 and 87%, respectively. ST depression of more than 1 mm occurred in 11 patients, ST elevation of more than 1 mm in three patients, T wave inversion in one and T normalization in nine. Significant differences of the effects of beta-blockers were noted on the peak effects of dobutamine as follows: heart rate increase of 46 +/- 22 versus 20 +/- 13 beats/min (P less than 0.0001); systolic pressure increase of 4 +/- 26 versus 22 +/- 19 mmHg (P less than 0.01); diastolic pressure decrease of 18 +/- 16 versus 10 +/- 12 mmHg (P less than 0.03) for patients without or with beta-blockers, respectively. Unifocal ventricular premature beats were noted in 10 patients, atrial premature beats in five and ventricular couplets in one. Angina occurred in 11 patients. Atypical chest pain occurred in seven patients, tingling in 11 and nausea in four. Thirty-six patients were totally asymptomatic. CONCLUSIONS: In this population with high prevalence (85%) of coronary artery disease, dobutamine stress echocardiography had high sensitivity and positive predictive value for coronary disease detection particularly in patients with left anterior descending or three vessel disease. The specificity and accuracy were not as good, but this may reflect the small number of normal patients. Dobutamine was well tolerated and conveniently administered.
BACKGROUND: The predilection of the left atrial appendage (LAA) for thrombus formation has long been known. METHODS AND RESULTS: We prospectively studied the two-dimensional echocardiographic and Doppler patterns of LAA function in 82 patients by transesophageal echocardiography. In the 63 patients in sinus rhythm, LAA area was measured during LAA diastole at the onset of the electrocardiographic (ECG) P wave (LAAmax) and after LAA systole at the ECG R wave (LAAmin) and LAA ejection fraction was calculated as (LAAmax-LAAmin)/LAAmax; peak Doppler velocity was recorded from the LAA outlet. The 58 patients in sinus rhythm without LAA thrombus were grouped according to left atrial size on transthoracic echocardiography; 39 patients had a left atrial size of less than 40 mm (group 1) and 19 had a left atrial size of 40 mm or greater (group 2). Five patients in sinus rhythm had LAA thrombus. In the 19 patients with atrial fibrillation or flutter LAAmax was measured independent of the ECG; three of these patients had LAA spontaneous contrast, four had thrombus, and one had both. Patients in sinus rhythm without LAA thrombus demonstrated a characteristic pattern of a contractile LAA apex and a noncontractile base with color flow and pulsed Doppler evidence of LAA emptying that coincided with the P wave. Patients in sinus rhythm with LAA thrombus had a mean +/- SD LAAmax (8.0 +/- 1.5 cm2) larger than that in group 1 (5.0 +/- 1.9 cm2) (p less than 0.01) but not group 2 (6.7 +/- 3.1 cm2), LAAmin (6.5 +/- 1.0 cm2) larger than that in both group 1 (2.3 +/- 1.5 cm2) and group 2 (4.2 +/- 2.7 cm2) (p less than 0.01), and LAA ejection fraction (17 +/- 11%) and LAA velocity (0.24 +/- 0.10 m/sec) less than those in both group 1 (55 +/- 21% and 0.48 +/- 0.24 m/sec, respectively) and group 2 (45 +/- 27% and 0.46 +/- 0.24 m/sec, respectively) (p less than 0.01). Patients with atrial fibrillation or flutter with LAA spontaneous contrast and/or thrombus had LAAmax (10.4 +/- 6.6 cm2) greater than that in patients with atrial fibrillation or flutter without LAA contrast and/or thrombus (6.8 +/- 3.0 cm2) (p less than 0.05). The LAA appeared as a static pouch in seven of eight of the former compared with in two of 11 of the latter. When attempted, Doppler demonstrated a recognizable fibrillatory LAA outflow velocity pattern in none of three in the former versus four of seven in the latter group. CONCLUSIONS: We conclude that the LAA has a characteristic pattern of emptying in sinus rhythm. LAA thrombus formation in sinus rhythm and atrial fibrillation is associated with both poor LAA contraction and LAA dilation.
A 52-year-old female patient treated for acute lymphoblastic leukemia with combination chemotherapy (cyclophosphamide, vincristine, adriamycin and prednisone), broad spectrum antibiotics and amphotericin via a Hickman catheter placed in the superior vena cava, developed echocardiographically confirmed tricuspid regurgitation. A second admission four months later showed only mild tricuspid regurgitation. The authors conclude that the amphotericin given via the central line caused valvulitis of the tricuspid valve.
A hemophiliac with acquired immunodeficiency syndrome-related complex was seen with sepsis related to a ventricular septal abscess. The abscess was debrided and the septum was patched with a single layer of autologous pericardium. The patient recovered and survived 6 months before dying of acquired immunodeficiency syndrome. At autopsy, the septal patch was well healed with no evidence of recurrent endocarditis.
Twenty-nine patients were entered in a clinical trial on aortic valve replacement with a stentless glutaraldehyde-fixed porcine aortic valve. This bioprosthesis is secured to the aortic root by the same technique used for aortic valve replacement with aortic valve homografts. The functional results obtained from this operation have been most satisfactory. To assess the hemodynamic benefit of eliminating the stent of a porcine aortic valve, we matched 22 patients with a stentless porcine bioprosthesis for age, sex, body surface area, valve lesion, and bioprosthesis size to 22 patients who had aortic valve replacement with a Hancock II bioprosthesis. Mean and peak systolic gradients across the aortic bioprosthesis and effective aortic valve areas were obtained by Doppler studies. Gradients across the stentless bioprosthesis were significantly lower than gradients across the Hancock II valve for every bioprosthesis size. Effective aortic valve areas of the stentless bioprosthesis were significantly larger than the valve areas of the Hancock II valve. Our data demonstrate that the hemodynamic characteristics of a glutaraldehyde-fixed porcine aortic bioprosthesis are greatly improved when the aortic root is used as a stent for the valve. This technique of implantation is expected to enhance the durability of the bioprosthesis, because the aortic root may dampen the mechanical stress to which the leaflets are subjected during the cardiac cycle.
Explore the source record for details and available documents.