The effect of lead attenuators on dose in homogeneous phantoms.

In radiotherapy, the radiation beam is sometimes shaped so as to deliver different doses to different organs or give a homogeneous dose to structures of different densities. This objective is achieved by the use of attenuating materials introduced into the beam. These attenuators alter the primary as well as the scattered radiation components of the beam. There is at present no accurate method of dose calculation for these situations. Most calculations are performed considering only the effect of the attenuators on the primary radiation beam and can produce large errors in dosimetry. In the present study, the broad beam attenuation is investigated in homogeneous phantoms for various radiation field sizes, photon beam energies, and depths in phantom. A calculational method taking account of primary as well as first scatter radiation is developed. This method predicts reasonably well the transmission through lead attenuators for the various experimental conditions investigated.

Humans

Dose distributions in dynamic stereotactic radiosurgery.

A treatment planning technique for calculation of dose distributions in dynamic stereotactic "radiosurgery" with a 10-MV isocentrically mounted linear accelerator is presented. The treatment planning for dynamic radiosurgery is a three-dimensional problem, since during treatment both the gantry and the couch rotate simultaneously, the gantry from 30 degrees to 330 degrees and the couch from 75 degrees to - 75 degrees. The patient surface and anatomical information is obtained from a family of computed tomography or magnetic resonance scans, and a stereotactic frame is used for target localization, treatment setup, and patient immobilization during the treatment. The dose calculational algorithm follows the gantry and couch rotation in an incremental fashion, and relies on measured stationary beam central axis percentage depth doses and dose profiles to calculate the normalized tissue-maximum-ratio distributions over a matrix of points defined on one of three orthogonal planes (transverse, sagittal, or coronal). The dose calculation algorithm is discussed in detail and calculated dose distributions for single plane and dynamic radiosurgery compared with measured data.

Brain Diseases

Broad beam and narrow beam attenuation in Lipowitz's metal.

Attenuation properties of Lipowitz's metal have been studied for narrow and broad beams of cobalt-60 gamma rays and 4-10 MV x-rays. The measured transmitted fraction for geometries used in radiotherapy depends on the field size and depth of measurement. Therefore a calculation of dose for partially attenuated beams based on narrow beam attenuation coefficients can cause large errors in dosimetry. Our simple calculation of transmitted fractions based on primary attenuation and scattered radiation agrees quite well with the measured data for therapeutic geometries. Also given is a table for linear, mass attenuation, and mass energy absorption coefficients of Lipowitz's metal in the photon energy range from 10 keV to 10 MeV.

Alloys

The influence of beam parameters on percentage depth dose in electron arc therapy.

The dependence of rotational or arc electron beam percentage depth doses on the depth of isocenter di and nominal beam field width w is presented. A characteristic angle beta, which uniquely depends on w and di, is defined and the dependence of the radial percentage depth doses on angle beta discussed. It is shown that the characteristic angle beta concept can be used in clinical situations to predict the shape of the percentage depth dose curve when w and di are known, or, more importantly, it can be used to determine the appropriate w when di and the percentage depth dose characteristics are known.

Electrons

Calculation of dose in homogeneous phantoms for partially attenuated photon beams.

Measured and calculated dose distributions under attenuators, which are of smaller cross-sectional dimensions than the radiation field, are presented. The study was performed on a 4-MV linac at a source-surface distance of 120 cm on the beam central axis in a water phantom for several thickness and cross sections of lead attenuators. Dose correction factors, which are used to multiply the open beam data to get dose distributions under partial attenuators, depend strongly on attenuator parameters and on depths in phantom. A method to calculate dose correction factors for any combination of attenuator parameters and any phantom depth is presented. The calculated dose distributions under partial attenuators agree well with measured data, which indicates that the method can be applied in clinical situations.

Humans

Calculation of dose profiles in homogeneous phantoms for irregular, partially attenuated, photon beams.

Measured and calculated dose profiles under partial attenuators which cover only part of the radiation beam are presented. The study was performed for x-ray beams generated with a 4-MV linear accelerator at a source-surface distance of 120 cm in a water phantom for lead attenuators of arbitrary shape but constant thickness. Dose correction factors, which are used to multiply the open beam data to predict doses under partial attenuators, depend strongly on attenuator parameters, such as its thickness, lateral dimensions, and distance from phantom or patient surface, in addition to depending on depths in the phantom. The dose correction factors are calculated with Clarkson sector integration techniques, and the results, in spite of the simplifying assumptions used in the algorithm, generally agree with measured data to within 3%. The calculational method therefore may be applied to general clinical situations in which partial attenuators are used.

Humans

Electron dose rate and photon contamination in electron arc therapy.

The electron dose rate at the depth of dose maximum dmax and the photon contamination are discussed as a function of several parameters of the rotational electron beam. A pseudoarc technique with an angular increment of 10 degrees and a constant number of monitor units per each stationary electron field was used in our experiments. The electron dose rate is defined as the electron dose at a given point in phantom divided by the number of monitor units given for any one stationary electron beam. For a given depth of isocenter di the electron dose rates at dmax are linearly dependent on the nominal field width w, while for a given w the dose rates are inversely proportional to di. The dose rates for rotational electron beams with different di are related through the inverse square law provided that the two beams have (di,w) combinations which give the same characteristic angle beta. The photon dose at the isocenter depends on the arc angle alpha, field width w, and isocenter depth di. For constant w and di the photon dose at isocenter is proportional to alpha, for constant alpha and w it is proportional to di, and for constant alpha and di it is inversely proportional to w. The w and di dependence implies that for the same alpha the photon dose at the isocenter is inversely proportional to the electron dose rate at dmax.

Biometry

Dose distributions in radiosurgery.

A PC-based, three-dimensional treatment planning system, which may be used for planning of radiosurgical treatments with the Gamma unit or with any of the radiosurgical techniques based on isocentric linear accelerators (linacs), is described and used to calculate isodose distributions for various linac-based radiosurgical techniques ranging from the single plane rotation to a 4-pi geometry. The latter gives an isotropic dose falloff outside the target volume but cannot be used for practical radiosurgery, while the single plane rotation is simple to use but gives unacceptably shallow dose falloffs in the transverse plane. Dose falloffs for several other techniques of varying degrees of complexity are shown and discussed. Also discussed is the effect of beam energy and beam profiles on radiosurgical dose distributions.

Humans