Intramodal and interaural interactions of the human slow auditory evoked potential.

It is proved that the human slow auditory evoked potential (SAEP) possess intramodal (frequency) and interaural specific properties. It is shown that tonotopic and bilateral organization of the SAEP generating system is better expressed at lower stimulus intensities. It is concluded that neuron populations of the SAEP generating system which perceive less different tone stimuli overlap each other greater than those which perceive more different stimuli. The data on intramodal and interaural specificity of SAEP are discussed from the point of view of its extralemniscal origin.

Acoustic Stimulation↗

Evoked magnetic responses of the human auditory cortex to minor pitch changes: localization of the mismatch field.

The neuromagnetic source localizations of the auditory M100 and the mismatch field (MMF) were studied using a large-array biomagnetometer. Standard tones of 1000 Hz and deviant tones of 1050 Hz were delivered with 90% and 10% probability, respectively. Wave forms of the derived MMF were computed by examining difference wave forms between the responses to the deviants and the responses to the standards preceding (D-P) and following (D-F) the deviants as well as to all remaining standards (D-A). The subset of standards preceding the deviants was used for a more realistic comparison with the set of deviants (having the same number of epochs and a similar signal-to-noise ratio), while the subset of standards following the deviants served to answer the question whether those standards also elicit an MMF. The MMF deflections were compared with each other, with the "native" MMF occurring in response to the deviants, and with wave M100. (The MMF as it appears in the unprocessed response to the deviants was termed "native" for an easy distinction from the "derived" MMF.) Our results demonstrate a distinct MMF deflection, corresponding in latency to the simultaneously recorded fronto-central electrical MMN. Source analysis, using a single moving dipole model, showed the same spatial localization for the native MMF and for the different derived MMFs. The MMF source location turned out to be significantly anterior, medial and inferior relative to the sources of the M100. The present data also demonstrate that a minor frequency deviation may not activate measurably different M100 generators, yet be sufficient to trigger the nearby but spatially distinct mismatch generator.

Acoustic Stimulation↗

Relationship of transient and steady-state auditory evoked fields.

Transient and steady-state auditory evoked fields (AEFs) to brief tone pips were recorded over the left hemisphere at 7 different stimulus rates (0.125-39 Hz) using a 37-channel biomagnetometer. Previous observations of transient auditory gamma band response (GBR) activity were replicated. Similar rate characteristics and equivalent dipole locations supported the suggestion that the steady-state response (SSR) at about 40 Hz represents the summation of successive overlapping (10 Hz) middle latency responses (MLRs). On the other hand, differences in equivalent dipole locations and habituation effects suggest that the magnetically recorded GBR is a separate phenomenon which occurs primarily at low stimulus rates and is unrelated to either the magnetically recorded MRL or SSR.

Acoustic Stimulation↗

Study of the human auditory cortices using a whole-head magnetometer: left vs. right hemisphere and ipsilateral vs. contralateral stimulation.

Structural and functional asymmetries of the temporal lobe affect language development and may also play a role in a variety of disorders, ranging from specific language impairment to schizophrenia. Whole-head neuromagnetometers allow the noninvasive measurement of functional asymmetries since activity from both hemispheres is recorded simultaneously. In the present study, the location of the auditory cortices and their responsiveness to pure tones was compared between hemispheres in healthy human subjects. Data suggest a greater contralateral than ipsilateral activation. In line with previous findings, sources of responses for the right hemisphere seem to be more anterior than for the left one.

Acoustic Stimulation↗

Frequency-specific threshold determination with the CERAgram method: basic principle and retrospective evaluation of data.

A method for the objective evaluation of the hearing threshold using cortical evoked response audiometry was developed. The method results in a kind of objective audiogram, visualizing the significance of an auditory evoked potential (AEP) in a scheme similar to a conventional audiogram. In the present implementation of the method, four frequencies are tested quasi-simultaneously (500, 1000, 2000 and 3000 Hz; intensity steps of 5 dB). The significance of an evoked potential is assessed by means of the Rayleigh test, which is applied to the phase values derived from certain time windows of the single-trial epochs. A retrospective analysis of 1, 920 threshold estimations in 240 subjects suggested that the detection threshold (lowest stimulus intensity yielding a significant response) was, on the average, 7.5 dB above the electrophysiological threshold (intensity where the AEP amplitude vanishes). The grand-average amplitude-intensity characteristic was approximated by the function a(1 - exp(-I/b)), with a = 6.25 microV, b = 22.3 dB and I representing the intensity (in decibels) relative to the electrophysiological threshold.

Auditory Perception↗