Evaluation of MK filters for recovery of enteroviruses from tap water.

The MK filter is an electropositively charged filter that can be used to concentrate enteroviruses from large volumes (400 to 1,000 liters) of water. This filter is less expensive than the commonly used 1MDS electropositive filter. In this study, we compared the recovery of poliovirus 1 (PV1) and that of coxsackievirus B3 (CB3) from 378 liters of tap water, using both the MK and the 1MDS filters. Viruses were eluted from the filters with 3% beef extract buffered with 0.05 M glycine (pH 9.5) and reconcentrated via organic flocculation. At high virus inputs (approximately 10(6) PFU), the overall recovery (after elution and reconcentration) of PV1 and CB3 from tap water with the MK filter was less than that achieved with the 1MDS filter (P < 0.05). The recoveries of PV1 from tap water with the MK and 1MDS filters were 73.2% +/- 26% (n = 5 trials) and 90.2% +/- 5.9% (n = 5 trials), respectively. The recoveries of CB3 from tap water with the MK and 1MDS filters were 32.8% +/- 34.5% (n = 4 trials) and 95.8% +/- 12.0% (n = 4 trials), respectively. This study indicated that the MK filter consistently provided lower recovery, with wider variability, of PV1 and CB3 from tap water than the 1MDS filter.

Enterovirus↗

Detection of naturally occurring enteroviruses and hepatitis A virus in undigested and anaerobically digested sludge using the polymerase chain reaction.

Four undigested and four anaerobically digested sewage sludge samples were analyzed for enteroviruses and hepatitis A virus using seminested and double polymerase chain reaction (PCR), respectively. For enteroviruses, all eight samples were positive when detection was by seminested PCR. Using cell culture all samples except two digested sludge samples were positive. For hepatitis A virus, seven out of eight samples were positive by PCR detection. In all samples, PCR inhibitory substances were removed by passage through Sephadex G-50 and Chelex 100 columns. Overall the PCR methodology was highly successful in identifying the presence of both viruses; however, with this methodology, there was no indication as to whether enteroviruses or hepatitis A viruses not confirmed in cell culture were infectious.

Anaerobiosis↗

Hazards from pathogenic microorganisms in land-disposed sewage sludge.

Sewage sludge is a complex mixture of organic and inorganic compounds of biological and mineral origin that are precipitated from wastewater and sewage during primary, secondary, and tertiary sewage treatment. Present in these sludges are significant numbers of microorganisms that include viral, bacterial, protozoan, fungal, and helminth pathogens. The treatment of sludge to reduce biochemical oxygen demand, solids content, and odor is not always effective in reducing numbers of pathogens. This becomes a public health concern because the infectious dose for some of these pathogens may be as low as 1 particle (virus) to 50 organisms (Giardia). When sludge is applied to land for agricultural use and landfill compost, these pathogens can survive from days (bacteria) to months (viruses) to years (helminth eggs), depending on environmental conditions. Shallow aquifers can become contaminated with pathogens from sludge and, depending on groundwater flow, these organisms may travel significant distances from the disposal site. Communities that rely on groundwater for domestic use can become exposed to these pathogens, leading to a potential disease outbreak. Currently, methods to determine the risk of disease from pathogens in land-disposed sludge are inadequate because the sensitivity of pathogen detection is poor. The application of recombinant DNA technology (gene probes and polymerase chain reaction) to environmental samples may provide increased sensitivity for detecting specific pathogens in land-disposed sludge and greatly improved risk assessment models for our exposure to these sources of pathogens.

Hazardous Waste↗

Polymerase chain reaction detection of nonviable bacterial pathogens.

Polymerase chain reaction (PCR) methodologies for detection of pathogens in environmental samples are currently available. However, positive amplification products for any set of primers only signal that the appropriate target nucleic acid sequences were present in the sample. The presence of the amplification products does not imply that the target organisms were viable. Here we show that PCR will detect nonviable cells, as long as intact target nucleic acid sequences are available. In an environmental water sample, nucleic acids degraded quickly and were not detectable by PCR after 3 weeks even when stored at 4 degrees C. However, these data show that there is a window of opportunity for PCR analyses to result in false positives with respect to viable cells. We further show that care must be taken in the way samples are stored for future PCR amplifications and that filter sterilization of media is not acceptable for long-term preservation of samples for PCR.

Bacteria↗

Detection of enteroviruses in groundwater with the polymerase chain reaction.

Standard methods for the detection of enteroviruses in environmental samples involve the use of cell culture, which is expensive and time-consuming. The polymerase chain reaction (PCR) is an attractive method for the detection of enteroviruses in water because primary cell culture is not needed and the increased sensitivity of PCR allows detection of the low numbers of target DNAs and RNAs usually found in environmental samples. However, environmental samples often contain substances that inhibit PCR amplification of target DNA and RNA. Procedures that remove substances that interfere with the amplification process need to be developed if PCR is to be successfully applied to environmental samples. An RNA-PCR assay for the detection of enteroviruses in water was developed and used to test a variety of groundwater concentrates and humic acid solutions seeded with poliovirus type 1. The groundwater samples and humic acid solutions were treated with Sephadex G-50, Sephadex G-100, Sephadex G-200, Chelex-100 resin, and a mixed bed resin to remove PCR-inhibitory material from the samples. Sephadex G-100 in combination with Chelex-100 was found to be very effective in removing inhibitory factors for the detection of enteroviruses in groundwater concentrates by PCR. Viruses were detected in two of the groundwater concentrates by the RNA-PCR assay after treatment with Sephadex G-100 plus Chelex-100. This was confirmed by tissue culture, suggesting that the treatment protocol and, subsequently, the RNA-PCR assay are applicable for the detection of enteroviruses in environmental samples.

Base Sequence↗

Specific detection of Salmonella spp. by multiplex polymerase chain reaction.

Three sets of oligonucleotide primers were used in the polymerase chain reaction (PCR) assay to detect Salmonella species. phoP primers specific to the phoP/phoQ loci of coliform pathogenic bacteria such as Salmonella, Shigella, Escherichia coli, and Citrobacter species served as presumptive indicators of enteric bacteria. In addition to the phoP primers, the Hin and the H-1i primers, which targeted a 236-bp region of hin/H2 and a 173-bp region of the H-1i flagellin gene, respectively, were used. Both Hin and H-1i primers are specific to motile Salmonella species and are not present in Shigella, E. coli, or Citrobacter species. Thus, by multiplex PCR amplification, Salmonella species including Salmonella typhi, Salmonella typhimurium, Salmonella paratyphi A, and Salmonella enteritidis can be specifically detected. Optimal reaction conditions have been described to demonstrate this specific, sensitive detection of Salmonella species. By using agarose gel electrophoresis for detection of the PCR-amplified products, the sensitivity of detection was 10(2) CFU after 25 cycles of PCR and 1 (10(0)) CFU after a 50-cycle double PCR. The efficacy of these primers was demonstrated on environmental isolates which had previously been confirmed as Salmonella species by the use of conventional cultural techniques. In addition, positive amplifications resulted from Salmonella species in environmental samples including soil and water.

Animals↗

Persistence of viruses in desert soils amended with anaerobically digested sewage sludge.

Pima County, Ariz., is currently investigating the potential benefits of land application of sewage sludge. To assess risks associated with the presence of pathogenic enteric viruses present in the sludge, laboratory studies were conducted to measure the inactivation rate (k = log(10) reduction per day) of poliovirus type 1 and bacteriophages MS2 and PRD-1 in two sludge-amended desert agricultural soils (Brazito Sandy Loam and Pima Clay Loam). Under constant moisture (approximately -0.05 x 10 Pa for both soils) and temperatures of 15, 27, and 40 degrees C, the main factors controlling the inactivation of these viruses were soil temperature and texture. As the temperature increased from 15 to 40 degrees C, the inactivation rate increased significantly for poliovirus and MS2, whereas, for PRD-1, a significant increase in the inactivation rate was observed only at 40 degrees C. Clay loam soils afforded more protection to all three viruses than sandy soils. At 15 degrees C, the inactivation rate for MS2 ranged from 0.366 to 0.394 log(10) reduction per day in clay loam and sandy loam soils, respectively. At 27 degrees C, this rate increased to 0.629 log(10) reduction per day in clay loam soil and to 0.652 in sandy loam soil. A similar trend was observed for poliovirus at 15 degrees C (k = 0.064 log(10) reduction per day, clay loam; k = 0.095 log(10) reduction per day, sandy loam) and 27 degrees C (k = 0.133 log(10) reduction per day, clay loam; k = 0.154 log(10) reduction per day, sandy loam). Neither MS2 nor poliovirus was recovered after 24 h at 40 degrees C. No reduction of PRD-1 was observed after 28 days at 15 degrees C and after 16 days at 27 degrees C. At 40 degrees C, the inactivation rates were 0.208 log(10) reduction per day in amended clay loam soil and 0.282 log(10) reduction per day in sandy loam soil. Evaporation to less than 5% soil moisture completely inactivated all three viruses within 7 days at 15 degrees C, within 3 days at 27 degrees C, and within 2 days at 40 degrees C regardless of soil type. This suggests that a combination of high soil temperature and rapid loss of soil moisture will significantly reduce risks caused by viruses in sludge.

Journal Article↗

Inactivation of coliphage MS-2 and poliovirus by copper, silver, and chlorine.

The efficacy of electrolytically generated copper and silver ions (400 and 40 micrograms/L, respectively) was evaluated separately and in combination with free chlorine (0.2 and 0.3 mg/L) for the inactivation of coliphage MS-2 and poliovirus type 1 in water at pH 7.3. The inactivation rate was calculated as log10 reduction/min: k = -(log10 Ct/C0)/t. The inactivation of both viruses was at least 100 times slower in water containing 400 and 40 micrograms/L copper and silver, respectively (k = 0.023 and 0.0006 for MS-2 and poliovirus, respectively), compared with water containing 0.3 mg/L free chlorine (k = 4.88 and 0.036). Significant increases in the inactivation rates of both viruses were observed in test systems containing 400 and 40 micrograms/L copper and silver, respectively, with 0.3 mg/L free chlorine when compared with the water systems containing either metals or free chlorine alone. Poliovirus was approximately 10 times more resistant to the disinfectants than coliphage MS-2. This observation suggests either a synergistic or an additive effect between the metals and chlorine for inactivation of enteric viruses. Use of copper and silver ions in water systems currently used in swimming pools and spas may provide an alternative to high levels of chlorination.

Chlorine↗

Multilaboratory evaluation of methods for detecting enteric viruses in soils.

Two candidate methods for the recovery and detection of viruses in soil were subjected to round robin comparative testing by members of the American Society for Testing and Materials D19:24:04:04 Subcommittee Task Group. Selection of the methods, designated "Berg" and "Goyal," was based on results of an initial screening which indicated that both met basic criteria considered essential by the task group. Both methods utilized beef extract solutions to achieve desorption and recovery of viruses from representative soils: a fine sand soil, an organic muck soil, a sandy loam soil, and a clay loam soil. One of the two methods, Goyal, also used a secondary concentration of resulting soil eluants via low-pH organic flocculation to achieve a smaller final assay volume. Evaluation of the two methods was simultaneously performed in replicate by nine different laboratories. Each of the produced samples was divided into portions, and these were respectively subjected to quantitative viral plaque assay by both the individual, termed independent, laboratory which had done the soil processing and a single common reference laboratory, using a single cell line and passage level. The Berg method seemed to produce slightly higher virus recovery values; however, the differences in virus assay titers for samples produced by the two methods were not statistically significant (P less than or equal to 0.05) for any one of the four soils. Despite this lack of a method effect, there was a statistically significant laboratory effect exhibited by assay titers from the independent versus reference laboratories for two of the soils, sandy loam and clay loam.

Enterovirus↗

Detection of Giardia cysts with a cDNA probe and applications to water samples.

Giardiasis is the most common human parasite infection in the United States, causing a lengthy course of diarrhea. Transmission of Giardia species is by the fecal-oral route, and numerous waterborne outbreaks have been documented. The Environmental Protection Agency has regulated Giardia species in drinking water through the Surface Water Treatment Rule. Current methods for detection of Giardia species in water rely primarily on microscopic observation of water concentrates with immunofluorescence techniques. We evaluated the efficacy of using a gene-specific probe for the detection of Giardia species in water. A cDNA probe, 265 bp long, from the small subunit of rRNA of Giardia lamblia was used for detection of cysts. The replicative form of the M13 vector with an insert was isolated from lysed host Escherichia coli XL1-Blue and used for production of the cDNA probe by nick translation with 32P-labeled nucleotides. Six different protocols were tested for extracting nucleic acids from the cysts. With the most efficient procedure, disrupting Giardia cysts with glass beads in the presence of proteinase K, as few as 1 to 5 cysts per ml can be detected in water sample concentrates with dot blot hybridization assays.

Animals↗

Effects of organic matter on virus transport in unsaturated flow.

The effects of natural humic material and sewage sludge organic matter (SSOM) derived from primary treated sewage sludge on virus transport by unsaturated flow through soil columns were evaluated. Bacteriophage MS-2 was applied to loamy fine sand columns 0.052 m in diameter and 1.05 m long. Virus concentrations in the influent and effluent were measured daily for 7 to 9 days. In the first experiment, virus transport through two fresh soil columns was compared with that through a column previously leached with more than four pore volumes (T) of well water. The soil water organic matter concentrations in the leachate of the fresh soil declined with time. Relative virus concentrations (C/Co) from one fresh soil column reached 0.82 in 0.9 T and then declined to 0.51 by 2.1 T. The other fresh soil column reached and maintained a steady-state relative virus concentration [(C/Co)s] of 0.47 from 1.5 to 2.5 T. The leached column reached and maintained a (C/Co)s of 0.05. Concentrations measured at 0.2-, 0.4-, 0.8-, and 1.05-m depths indicated that most virus particles were removed in the surface 0.2 m. In the second experiment, one leached column was pretreated with SSOM derived from primary treated sewage sludge and the other leached column was untreated. SSOM concentrations declined with depth. A suspension of virus and SSOM in well water was applied to both columns. Although the (C/Co)s values were similar (0.41 for the pretreated column and 0.47 for the untreated column), breakthrough was delayed for the untreated column. Both natural humic material and sewage sludge-derived SSOM increased the unsaturated-flow transport of MS-2.

Adsorption↗

Rapid method for processing soil samples for polymerase chain reaction amplification of specific gene sequences.

Bacterial cells can be differentially separated from soil colloids on the basis of their buoyant densities. By using this principle, a modified sucrose gradient centrifugation protocol has been developed for separating bacterial cells from most of the soil colloids. Since the bacterial cell suspension still contained some colloidal soil particles, which inhibited polymerase chain reaction amplification, a new "double" polymerase chain reaction method of analysis was adopted for amplification of Tn5-specific gene sequences. This new protocol allowed rapid detection of small numbers (1 to 10 CFU/g) of bacterial cells present in soil samples.

Base Sequence↗

Disinfection of bacteria in water systems by using electrolytically generated copper:silver and reduced levels of free chlorine.

As an alternative disinfectant to chlorination, electrolytically generated copper:silver (400 and 40 micrograms/L copper and silver, respectively) with and without free chlorine (0.3 mg/L) was evaluated over a period of 4 weeks in indoor and outdoor water systems (100 L tap water with natural body flora and urine). Numbers of total coliform, pseudomonas, and staphylococci were all less than drinking water standards in systems treated with copper:silver and free chlorine and systems treated with free chlorine alone (1.0 mg/L). No significant differences (p less than or equal to 0.05) in bacterial numbers were observed between systems with copper:silver and free chlorine and those with free chlorine alone. Overall, free-chlorine treatments (0.3 or 1.0 mg/L) showed significantly lower heterotrophic plate numbers than those without free chlorine. When challenged with a natural Staphylococcus sp. isolate, water with copper:silver and free chlorine had a 2.4 log10 reduction in bacterial numbers within 2 min, while free chlorine alone or copper:silver alone showed 1.5 and 0.03 log10 reductions, respectively. Addition of copper:silver to water systems may allow the concentration of free chlorine to be reduced while still providing comparable sanitary quality of the water.

Bacteria↗

Recovery of hepatitis A virus from a water supply responsible for a common source outbreak of hepatitis A.

An outbreak of hepatitis A occurred in a north Georgia trailer park served by a private well. Of 18 residents who were serosusceptible to hepatitis A virus (HAV), 16 (89%) developed hepatitis A. Well water samples were collected 3 months after illness onset in the index case and 28 days after illness onset in the last trailer park resident. Hepatitis A virus antigen (HAVAg) was detected in the samples by enzyme immunoassay from three of the five cell lines following two 30-day passages and from a fourth cell line following a third passage of 21 days.

Adult↗

Efficacy of copper and silver ions and reduced levels of free chlorine in inactivation of Legionella pneumophila.

Water disinfection systems utilizing electrolytically generated copper and silver ions (200 and 20, 400 and 40, or 800 and 80 micrograms/liter) and low levels of free chlorine (0.1 to 0.4 mg/liter) were evaluated at room (21 to 23 degrees C) and elevated (39 to 40 degrees C) temperatures in filtered well water (pH 7.3) for their efficacy in inactivating Legionella pneumophila (ATCC 33155). At room temperature, a contact time of at least 24 h was necessary for copper and silver (400 and 40 micrograms/liter) to achieve a 3-log10 reduction in bacterial numbers. As the copper and silver concentration increased to 800 and 80 micrograms/liter, the inactivation rate significantly (P less than or equal to 0.05) increased from K = 2.87 x 10(-3) to K = 7.50 x 10(-3) (log10 reduction per minute). In water systems with and without copper and silver (400 and 40 micrograms/liter), the inactivation rates significantly increased as the free chlorine concentration increased from 0.1 mg/liter (K = 0.397 log10 reduction per min) to 0.4 mg/liter (K = 1.047 log10 reduction per min). Compared to room temperature, no significant differences were observed when 0.2 mg of free chlorine per liter with and without 400 and 40 micrograms of copper and silver per liter was tested at 39 to 40 degrees C. All disinfection systems, regardless of temperature or free chlorine concentration, showed increase inactivation rates when 400 and 40 micrograms of copper and silver per liter was added; however, this trend was significant only at 0.4 mg of free chlorine per liter.

Analysis of Variance↗

Evaluation of immunofluorescence techniques for detection of Cryptosporidium oocysts and Giardia cysts from environmental samples.

Cryptosporidium and Giardia species are enteric protozoa which cause waterborne disease. The detection of these organisms in water relies on the detection of the oocyst and cyst forms or stages. Monoclonal and polyclonal antibodies were compared for their abilities to react with Giardia cysts and Cryptosporidium oocysts after storage in water, 3.7% formaldehyde, and 2.5% potassium dichromate, upon exposure to bleach, and in environmental samples. Three monoclonal antibodies to Cryptosporidium parvum were evaluated. Each test resulted in an equivalent detection of the oocysts after storage, after exposure to bleach, and in environmental samples. Oocyst levels declined slightly after 20 to 22 weeks of storage in water, and oocyst fluorescence and morphology were dull and atypical. Oocyst counts decreased after exposure to 2,500 mg of sodium hypochlorite per liter, and fluorescence and phase-contrast counts were similar. Sediment due to algae and clays found in environmental samples interfered with the detection of oocysts on membrane filters. Two monoclonal antibodies and a polyclonal antibody directed against Giardia lamblia cysts were evaluated. From the same seeded preparations, significantly greater counts were obtained with the polyclonal antibody. Of the two monoclonal antibodies, one resulted in significantly lower cyst counts. In preliminary studies, the differences between antibodies were not apparent when used on the environmental wastewater samples. After 20 to 22 weeks in water, cyst levels declined significantly by 67%. Cysts were not detected with monoclonal antibodies after exposure to approximately 5,000 mg of sodium hypochlorite per liter.

Analysis of Variance↗

A novel method for liberating viral nucleic acid for assay of water samples with cDNA probes.

Rapid and sensitive methods are needed for the detection of enteric viruses to ensure proper drinking water quality. Gene probes have been shown to be useful for this purpose. Previously, samples to be assayed were treated with a series of phenol-chloroform extractions to release the viral nucleic acid. We have developed a more rapid procedure for liberating or exposing the genome of poliovirus for probing. In this study, a poliovirus model was used to test the ability of heat (65 degrees C for 30 min) for release or exposure of viral nucleic acid. Several different RNase inhibitors were tested for their ability to prevent viral RNA degradation. A comparison of the two methods indicates phenol-chloroform extraction is not necessary before probing. In addition to saving 2-4 h of time, maximum sensitivity levels were consistently obtained using this novel procedure.

DNA↗