Search PubMed⌕ Search

Biomedical subjects

C Meeker

Publications and source records attributed to C Meeker.

9 recordsLinked to original sources

Pall leukotrap affinity prion-reduction filter removes exogenous infectious prions and endogenous infectivity from red cell concentrates.

BACKGROUND AND OBJECTIVES: Three recent probable cases of transmission of a variant of human Creutzfeldt-Jakob disease (vCJD) through blood transfusion suggest that the disease can be transmitted through transfusion of blood components from presymptomatic blood donors. In this study, we investigated the performance of a new filter for reducing the levels of infectious prions (PrP(Sc)) from red cell concentrates (RCC). MATERIALS AND METHODS: Endogenous Infectivity: A pool of 500 ml of whole blood was collected from 263K-strain scrapie-infected hamsters into an anticoagulant, processed into non-leucoreduced RCC (NL-RCC), and then passed through a prion-reduction filter. Pre- and postfiltration samples were tested for PrP(Sc) by Western blot and infectivity by inoculation of healthy hamsters. Results of the endogenous infectivity study after 200 days post-inoculation are discussed. Exogenous (Spiking) Study: Scrapie-infected hamster brain homogenates containing PrP(Sc) were added to human RCC and then filtered. Levels of PrP(Sc) were determined by Western blot assay. The effect of prior leucodepletion of 'spiked' RCC on PrP(Sc) removal by the prion-removal filter was also assessed. RESULTS: In the endogenous infectivity study, at 200-day observation time, the prefiltered RCC transmitted disease to six of the 187 hamsters, whereas the filtered RCC did not transmit disease to any of 413 animals, P = 0.001. The prion filter also significantly reduced the concentration of leucocytes in the RCC by about 4 logs, P < 0.05. In the exogenous (spiking) study, the level of PrP(res) was significantly reduced in RCC P < 0.05. Prior leucodepletion of the RCC with a leucoreduction filter did not significantly reduce the concentration of exogenously spiked PrP(Sc), P > 0.05. CONCLUSION: The use of this new prion-reduction filter should reduce the risk of vCJD transmission through transfusion of RCC, the most widely transfused blood component.

Animals↗

Do patients with acute deep vein thrombosis have fever?

The purpose of this study was to determine whether those with lower extremity acute venous thrombosis have fever. During a recent 14.5-month period, 1847 patients undergoing lower extremity venous duplex scanning also had their oral temperature measured using a digital thermometer at the time of duplex examination. Patients were 57.8 +/- 17.3 years of age (range, 14 to 99). Temperature was 98.5 +/- 1.1 degrees F. Twenty-three patients had acute inferior vena cava thrombosis, 60 had acute iliac vein thrombosis, 138 had acute femoral venous thrombosis, and 131 had acute popliteal venous thrombosis. Calf vein thromboses were present in 102 patients, and 43 patients had superficial venous thrombosis. A total of 228 patients had acute lower extremity venous thrombosis in one or more of these venous segments. Temperature with acute lower extremity venous thrombosis was 98.7 +/- 1.05 degrees F versus 98.5 +/- 1.10 degrees F in those with no acute thrombosis. Although small, this temperature difference was statistically significant (P < 0.02). Acute deep venous thrombosis (DVT) was defined as acute popliteal or more proximal femoral, iliac, or vena cava thrombosis. The temperature for the 175 patients with acute DVT was 98.7 +/- 1.10 degrees F versus 98.5 +/- 1.10 degrees F for those without DVT (P < or = 0.035). There was no temperature that served to accurately differentiate those who did from those who did not have DVT. The frequency that patients with DVT had fever, defined as a temperature > or = 100 degrees F, was 9.1 per cent (16 of 175) with DVT versus 7.5 per cent (126 of 1678) without DVT (not significant). In the subgroup with a temperature > or = 101 degrees F, 4.6 per cent (8 of 175) with DVT had such a fever versus 3.4 per cent (57 of 1672) without DVT (not significant). Those undergoing venous duplex who were found to have acute lower extremity venous thrombosis, including acute DVT, had statistically higher temperatures, but such temperature differences were minimal. The incidence of fever, defined as a temperature > or = 100 degrees F or > or = 101 degrees F, was not different between those with and those without acute DVT. It appears that the presence of fever may not be a sensitive or specific indicator for the presence of underlying acute DVT.

Acute Disease↗

Duplex examination of the inferior vena cava.

Duplex examination of the inferior vena cava (IVC) was performed in 270 patients from 1/1/96 to 1/1/00 to define suitability of the IVC for caval interruption using noninvasive means. The IVC was interrogated using a 3-mHz curved linear array probe and an ATL Ultramark 9 ultrasound machine (Bothell, WA). Duplex measured IVC dimensions and defined presence of thrombus or anomalies. Of the 270 IVC duplex examinations 10.7 per cent (n = 29) could not be completed because of overlying bowel gas or for other technical reasons. Of the 241 completed studies 4.1 per cent (n = 10) revealed acute or chronic thrombosis of the IVC. The lateral diameter of the IVC was 20.3 +/- 4.4 mm (95% confidence interval 19.8-20.9 mm), whereas the anteroposterior diameter was 12.6 +/- 4.0 mm (95% confidence interval 12.1-13.1 mm). Excluding those with vena cava thrombosis maximum vena cava diameters exceeded 28 mm in only 2.2 per cent (n = 5) of those with technically adequate studies. Apart from the latter megacavas there were no major IVC anomalies detected. For those with incomplete studies body weight was 192 +/- 59 lb versus 169 +/- 38 lb for those with technically adequate studies (P = 0.008). Technically adequate vena cava duplex examinations can be performed in 89 per cent of patients. On the basis of this and one prior study done at this center IVC duplex can define vena cava dimensions and presence of thrombus. Using the standard criteria for IVC filter insertion that require presence of a maximum cava diameter < or = 28 mm and absence of caval thrombus or anomalies, 94 per cent (226 of 241) of those with complete duplex examinations would have been anatomically suitable for standard Greenfield filter insertion based on noninvasive testing.

Humans↗

Acute calf vein thrombosis: outcomes and implications.

The purpose of this study was to define the incidence of and outcomes associated with isolated acute calf vein thrombosis (CVT). From 11/95 through 6/97, 3096 patients underwent lower extremity venous duplex testing in a hospital-based vascular laboratory in which bilateral tibial and peroneal vein imaging were standard components of the venous duplex examination. CVT was present in 118 patients (3.8%), and 339 patients (10.9%) had acute proximal deep venous thrombosis (PDVT). Patients with CVT were 56.4+/-17.2 years of age (range, 18-92). Approximately 25 per cent with CVT had cancer (n = 30). Of the 18 patients with CVT who underwent ventilation-perfusion (V/Q) lung scanning, 56 per cent (n = 10) had high-probability scans. Venous duplex reports for those with CVT recommended follow-up venous duplex examination, which was done in 60 per cent (n = 71) of patients. Of the 71 patients with CVT who underwent follow-up testing, 15.5 per cent (n = 11) progressed to PDVT. The incidence of progression to deep venous thrombosis was 25 per cent (9 of 36) in those receiving anticoagulants at the time of initial venous duplex examination versus 5.7 per cent (2 of 35) in those not receiving anticoagulants (P = 0.046). With progression to PDVT, patients were more likely to have cancer (35% versus 7.8%; P = 0.009), more likely to have high-probability V/Q scans (36% versus 6.7%; P = 0.017), and more likely to die (27% versus 1.7%; P = 0.011) during follow-up. CVT was less common than proximal deep vein thrombosis and was also associated with pulmonary embolism. Progression of CVT was an adverse clinical event associated with greater chance of pulmonary embolism and death.

Acute Disease↗

Nonoperative therapy for postcatheterization femoral artery pseudoaneurysms.

Since November 1992, 160 patients were referred to the Vascular Surgery Laboratory for duplex scanning to assess whether a femoral artery pseudoaneurysm was present. Of these patients, 33 per cent (n = 53) had femoral artery pseudoaneurysms with maximal diameters ranging from 1.5 to 8.1 cm. Most pseudoaneurysms (79%; 42 of 53) followed diagnostic or therapeutic cardiac catheterization procedures. Pseudoaneurysms were treated by external compression using an ultrasound probe in 33 of these 53 patients, and thrombosis of the aneurysm was successfully induced in 76 per cent (n = 25) of those in whom nonoperative external compression therapy was attempted. Of the eight patients in whom compression was unsuccessful, three had severe pain that required cessation of compression, and femoral nerve involvement by the pseudoaneurysm was noted at surgery in two of the three. One additional patient refused a second attempt at compression due to discomfort. Of the other four failures of compression, four (50% overall) received anticoagulants during or prior to compression. In 25 patients with successful pseudoaneurysm thrombosis after external compression, none had severe pain from compression, and 40 per cent (n = 10) were on anticoagulants until or during compression. Four of the 53 (7.5%) pseudoaneurysms diagnosed in the vascular laboratory subsequently thrombosed spontaneously, and two patients (3.8%) experienced pseudoaneurysm rupture. Thrombosis of postcatheterization pseudoaneurysms can be achieved by nonoperative compression therapy in most patients. Severe pain during external compression suggests possible femoral nerve involvement by the pseudoaneurysm and is an indication for surgical therapy.

Aged↗

Vena cava duplex imaging before caval interruption.

PURPOSE: Venacavograms are routinely obtained before vena cava filter placement to evaluate cava size, patency, and the presence of thrombus or venous anomalies. The objective of this study was to determine the ability of duplex ultrasonography to adequately evaluate the inferior vena cava (IVC) for size, patency, and the presence of thrombus before Greenfield filter (GF) insertion. METHODS: Duplex ultrasonographic scans were performed in 40 patients who had documented lower-extremity deep venous thrombosis diagnosed by duplex scan before GF placement. The infrarenal transverse and anteroposterior diameters of the IVC were measured, and the entire IVC was imaged for patency and the presence of thrombus or anomalies. Preoperative venacavograms were not obtained in any patients who had GFs placed in the operating room, but was performed during surgery during filter insertion. An additional 26 patients who had deep venous thrombosis and did not have caval interruption underwent IVC duplex to determine the patency and proximal extent of venous thrombosis. RESULTS: The indications for GF placement were contraindication to anticoagulation in 72.5% (29 patients); five filters were placed prophylactically; three for failure of anticoagulation; two after a complication of anticoagulation; and one before pulmonary embolectomy. The filters were placed in the operating room by surgeons in 82.5% of patients, with the remainder inserted in an angiography suite by an interventional radiologist. The ability of duplex to measure a transverse diameter of 26 mm or less had a sensitivity of 97.5%, positive predictive value of 100%, and overall accuracy of 97.5% using venacavography as the standard. Measurements of IVC diameter by duplex correlated with those based on venacavograms (r = 0.766; p < 0.001). Of the entire group of 66 IVC duplex examinations, one (1.5%) was incomplete because of technical limitations. IVC thrombus was noted by duplex in two patients who underwent GF insertion, which was confirmed with venacavography. No IVC anomalies were noted by duplex scans or venacavograms. CONCLUSION: Duplex ultrasonography is a useful and accurate method for assessment of the IVC before vena cava filter placement.

Adult↗

Assessment of noninvasive lower extremity arterial testing versus pulse exam.

Palpation of pedal pulses was compared to noninvasive testing in 100 patients referred to a vascular laboratory. Subjects were 65 +/- 13 (mean +/- s.d.) years old. The right dorsalis pedis (DP) artery served as the reference artery for comparison of Doppler studies with physical examination of the pulses. Absolute Doppler pressures in the right DP were 129 +/- 50 mm Hg. The right ankle:brachial index (ABI) was 0.86 +/- 0.32. There were significant differences in ABI in those with (0.68 +/- 0.28) vs without (0.95 +/- 0.31) claudication in either extremity (p < 0.001). Rest pain was also associated with lower ABI (P < 0.04). Diabetics, hypertensives, claudicants and those with ischemic rest pain were less likely to have palpable pulses (P < 0.035). With right DP pressure >/= 118 mm Hg, 63 per cent of subjects had a palpable DP pulse, whereas 68 per cent with ABI > 0.82 had a palpable right DP. Of those (n = 35) with a right DP pressure < 118 mm Hg, only 6 per cent (n = 2) had a palpable pulse, whereas 5 per cent (2/40) with ABI </= 0.82 had palpable DP pulses. Based on these findings, it was predicted that a pulse would likely not be palpable in the left DP with a pressure < 118 mm Hg or with AB </= 0.82. The prediction based on systolic ankle pressures was correct, with 66 per cent sensitivity and 91 per cent specificity. The predication that a left DP pulse would not be palpable with AB </= 0.82 was more accurate (78% sensitive, 97% specific). Presence of a palpable DP pulse suggests the presence of a Doppler pressure >/= 188 mm Hg and ABI > 0.82. The range of ankle pressures with palpable right DP pulses was 64-220 mm Hg, whereas the range with nonpalpable DP was 42-300 mm Hg. Given the frequent disparity of pulse exam and ankle pressures, noninvasive Doppler testing may be necessary for many patients to accurately assess the vascular status of the leg.

Adult↗

Effects of the Nd:YAG laser on DNA synthesis and collagen production in human skin fibroblast cultures.

Human skin fibroblasts were subjected to treatment with a Neodymium:YAG laser at 1060 nm with varying levels of energy determined by a reproducible method of dosimetry. DNA synthesis in the cells was measured by the incorporation of [3H]thymidine, and collagen production was monitored by the synthesis of nondialyzable [3H]hydroxyproline after incubation of cells with [3H]proline. Using energy levels equal to 1.7 X 10(3) J/cm2, a significant reduction in DNA synthesis was noted, while the cells remained viable as tested by the trypan blue exclusion test. With energy levels higher or equal to 2.3 X 10(3) J/cm2, the suppression of DNA synthesis was accompanied by cell nonviability. The collagen production, when measured immediately following the treatment with 1.7 X 10(3) J/cm2, was markedly reduced, and similar effects were observed with higher energy levels. However, when the cells were tested for collagen production at 20 hours following laser treatment, there was a significant decrease in collagen production at energy levels as low as 1.1 X 10(3) J/cm2, a dose that did not affect DNA synthesis or cell viability. Thus, the results indicate that the Nd:YAG laser can selectively suppress collagen production without affecting cell proliferation. These observations suggest that laser treatment could potentially be used to reduce collagen deposition in conditions such as keloids and hypertrophic scars.

Cells, Cultured↗

A benchmark project to improve cost and quality outcomes for CABG patients.

Today's health care environment is forcing health care providers to find ways to provide more effective and efficient care. This article describes a collaborative benchmark project that examined acute care for coronary artery bypass graft surgery patients and reduced costs and improved patient outcomes.

Benchmarking↗