Search PubMed⌕ Search

Biomedical subjects

C Macaya

Publications and source records attributed to C Macaya.

At least 37 records · Page 2Linked to original sources

Continued benefit of coronary stenting versus balloon angioplasty: five-year clinical follow-up of Benestent-I trial.

OBJECTIVES: This study sought to establish whether the early favorable results in the Benestent-I randomized trial comparing elective Palmaz-Schatz stent implantation with balloon angioplasty in 516 patients with stable angina pectoris are maintained at 5 years. BACKGROUND: The size of the required sample was based on a 40% reduction in clinical events in the stent group. Seven months and one-year follow-up in this trial showed a decreased incidence of restenosis and clinical events in patients randomized to stent implantation. METHODS: Data at five years were collected by outpatient visit, via telephone and via the referring cardiologist. Three patients in the stent group and one in the percutaneous transluminal coronary angioplasty (PTCA) group were lost to follow-up at five years. Major clinical events, anginal status and use of cardiac medication were recorded according to the intention to treat principle. RESULTS: No significant differences were found in anginal status and use of cardiac medication between the two groups. In the PTCA group, 27.3% of patients underwent target lesion revascularization (TLR) versus 17.2% of patients in the stent group (p = 0.008). No significant differences in mortality (5.9% vs. 3.1%), cerebrovascular accident (0.8% vs. 1.2%), myocardial infarction (9.4% vs. 6.3%) or coronary bypass surgery (11.7% vs. 9.8%) were found between the stent and PTCA groups, respectively. At five years, the event-free survival rate (59.8% vs. 65.6%; p = 0.20) between the stent and PTCA groups no longer achieved statistical significance. CONCLUSIONS: The original 10% absolute difference in TLR in favor of the stent group has remained unchanged at five years, emphasizing the long-term stability of the stented target site.

Angina Pectoris↗

Endogenous anti-inflammatory response after coronary injury in a porcine model.

BACKGROUND: Corticotropin-releasing hormone (CRH)/adrenocorticotropic hormone (ACTH)/cortisol is the major anti-inflammatory system. After percutaneous translumenal angioplasty, an inflammatory process is triggered. We investigate whether CRH/ACTH/cortisol axis is activated after deep vessel wall injury (DVWI). MATERIALS AND METHODS: Plasma and leukocyte CRH and ACTH, serum cortisol and IL-1beta, and leukocyte cAMP were measured (ELISA) in 16 pigs after anaesthesia (baseline), 60 min into anaesthesia without causing vascular injury and 90 min after DVWI of the left anterior descending (LAD) coronary artery induced by percutaneous directional atherectomy (Atherocath GTO 7F; DVI, Inc., Temecula, USA). Biochemical variables were also measured at baseline, 60 and 180 min into anaesthesia in six additional pigs without coronary intervention. RESULTS: MANOVA showed that CRH/ACTH/Cortisol, cAMP and IL-1beta production was not modified during anaesthesia. Post-DVWI plasma CRH (0.077 +/- 0.046 ng mL-1), and cellular cAMP (0.14 +/- 0.067 pmol 10(-6) cells) increased significantly (P = 0.001) with respect to their baseline values (CRH = 0.036 +/- 0.013 ng mL-1; cAMP = 0.081 +/- 0.034 pmol 10-6). There was also a statistically significant increase (P = 0.02) in post-DVWI IL-1beta (from 46.6 +/- 12.8 to 64.05 +/- 13.5 pg mL-1), and in serum cortisol (P = 0.05) compared to its baseline values (8.98 +/- 3.2 microgr dL-1 vs. 6.57 +/- 2.3 microgr dL-1, respectively). CONCLUSION: In our experimental model, coronary vessel wall injury-activated CRH/ACTH/cortisol axis caused a significant increase in plasma CRH, cortisol and cellular cAMP levels, which may influence the response of coronary arteries to injury.

Adrenocorticotropic Hormone↗

Ace D/I polymorphism and incidence of post-PTCA restenosis: a prospective, angiography-based evaluation.

Early restenosis is the major complication of percutaneous transluminal coronary angioplasty (PTCA), occurring in approximately 30% of all initially successful procedures. The D/I polymorphism of the ACE gene, which has variably been reported to represent a risk factor for manifestations of ischemic heart disease, has recently been implicated in the pathophysiology of restenosis after PTCA by some investigators but not by others. All studies conducted thus far involved relatively small sample sizes. We investigated the possible association of ACE D/I genotype and post-PTCA restenosis in a large, prospective sample of patients followed by quantitative coronary angiography. The ACE D/I gene polymorphism was characterized in a cohort of 779 patients, of whom 342 (cases) had developed restenosis (as defined by >50% loss of lumen compared with immediate postprocedure results) at repeat quantitative coronary angiography at 6 months after PTCA. Allele frequencies for the ACE D and I: alleles were 0.58 and 0.42 in cases and 0.58 and 0.42 in control subjects. All observed genotype frequencies were in Hardy-Weinberg equilibrium. There was no evidence for an association between genotype and restenosis or degree of lumen loss. The data from this largest study of its kind conducted so far provide no evidence for an association of the ACE D/I allelic polymorphism with incidence of restenosis after PTCA. On the basis of the power of this study, we conclude that in a general population, the ACE D/I polymorphism is not a useful marker to assess risk of post-PTCA restenosis.

Alleles↗

Skin dose and dose-area product values for interventional cardiology procedures.

Coronary angiography and percutaneous transluminal coronary angioplasty procedures performed in four different facilities were monitored in the present study by measuring maximum skin dose, dose-area product and other operational parameters. Radiographic slow film, thermoluminescent dosemeters and transmission ion chambers were used to measure dose related quantities. Values of 107-711 mGy for maximum skin dose and 27.3-370.6 Gy cm2 for dose-area product were found, together with cumulative skin dose estimates of 110-3706 mGy. A discussion of the relationship of measured dose-area product and skin dose values is made using a field concentration factor defined as a way to interpret the findings. No general correlation was observed between dose-area product and maximum skin dose. Cumulative skin dose estimates throughout a procedure should be discarded as a realistic method for assessing deterministic risk in cardiology procedures. Slow film in addition to thermoluminescent dosemeters for measurement of maximum skin dose is a good alternative, especially for complex interventional procedures. For repeated procedures, combining film and dose-area product monitoring favours optimization of radiation protection for the patient.

Angioplasty, Balloon, Coronary↗

Skin radiation injuries in patients following repeated coronary angioplasty procedures.

This study investigates the incidence of skin injuries and retrospectively estimates skin doses in a sample of patients who had multiple coronary angiographies and who underwent more than four percutaneous transluminal coronary angioplasties (PTCAs), performed primarily by the same team of cardiologists in a university hospital. A database of 7824 PTCAs performed during the last 14 years was analysed. Patients were selected and reviewed by a cardiologist and two radiotherapists with experience in radiation-induced skin injuries. A retrospective analysis of skin doses was performed using data from the patients' files and from the quality assurance (QA) programme of the hospital, which includes periodic patient dose measurements. 14 patients were included in the study. Each patient had undergone between 4 and 14 coronary angiographies and between 5 and 10 PTCAs, performed over a period of 2-10 years. The estimated mean dose-area product per procedure was 46 Gy cm(2) for coronary angiography and 82 Gy cm(2) for PTCA. Mean values of maximum skin dose per procedure were 217 mGy for the diagnostic studies and 391 mGy for the PTCAs. Only a slight radiation skin injury was clinically demonstrated in one patient with a history of 10 coronary angiographies and 10 PTCAs (estimated maximum skin dose 9.5 Gy). Another patient who underwent 14 coronary angiographies and 10 PTCAs (estimated maximum skin dose 7.3 Gy) showed a slight telangiectasia and discrete pigmentation. Another patient with a cutaneous lupus erythematosus showed pigmentation in the area of the radiation field following seven coronary angiographies and six PTCAs (estimated maximum skin dose 5.6 Gy), as expected bearing in mind that skin tolerance to high doses may be altered for patients with this pathology. Each of the remaining 11 patients with no skin injuries had undergone between 5 and 7 PTCAs and between 5 and 14 additional angiographies. None of the 14 patients reported acute skin injuries and no necrosis or radiodermatitis was observed.

Adult↗

Acute stent thrombosis visualized by intravascular ultrasound.

Subacute stent thrombosis is currently a rare but feared complication in patients undergoing coronary intervention. Intravascular ultrasound is a useful technique to guide stent implantation. However, its value in patients suffering from acute stent thrombosis has not been described. Herein, we present the intravascular ultrasound findings of a patient experiencing ongoing stent thrombosis and impending vessel closure.

Adult↗

Initial results and long-term clinical and angiographic outcome of coronary stenting in women.

To assess whether gender influences the results of coronary stenting, 158 consecutive women undergoing coronary stenting were compared with 823 consecutive men. Women had more adverse baseline characteristics, a higher hospital mortality, and were independently associated with procedural failure/complications (relative risk 2.4, 95% confidence interval 1.2 to 4.8); however, the long-term event-free survival and the restenosis rate were not influenced by gender.

Age Factors↗

Fate of stent-related side branches after coronary intervention in patients with in-stent restenosis.

OBJECTIVES: We sought to assess the fate of stent (ST)-related side branches (SB) after coronary intervention in patients with in-ST restenosis. BACKGROUND: In-ST restenosis constitutes a therapeutic challenge. Although the fate of lesion-related SB after conventional angioplasty or initial coronary stenting is well established, the outcome of ST-related SB in patients with in-ST restenosis undergoing repeat intervention is unknown. METHODS: One hundred consecutive patients (age 61 +/- 11 years, 22 women) undergoing repeat intervention for in-ST restenosis (101 ST) were prospectively studied. Two hundred and twenty-six SB spanned by the ST were identified. The SB size, type, ostium involvement, location within the ST and take-off angle were evaluated. The SB TIMI (Thrombolysis in Myocardial Infarction trial) flow grade was studied in detail before, during, immediately after the procedure, and at late angiography. RESULTS: Occlusion (TIMI flow grade = 0) was produced in 24 (10%) SB, whereas some degree of flow deterioration (> or = 1 TIMI flow grade) was observed in 57 SB (25%). The SB occlusion was associated with non-Q wave myocardial infarction in two patients (both had large and diseased SB). Side-branch occlusion at the time of initial stenting (RR [relative risk] 11.1, 95% CI [confidence interval] 3.5-35.5, p < 0.001), diabetes (RR 3.5, 95% CI 1.1-10.5, p = 0.02), SB ostium involvement (RR 5.0, 95% CI 1.4-17.2, p = 0.004), baseline SB TIMI flow grade <3 (RR 5.5, 95% CI 1.7-18.1, p = 0.005), and restenosis length (RR 1.05 95% CI 1.01-1.11, p = 0.03) were identified as independent predictors of SB occlusion. Late angiography in 19 initially occluded SB revealed that 17 (89%) were patent again. The long-term clinical event-free survival (81% vs. 82% at two years) in patients with and without initial SB occlusion was similar. CONCLUSIONS: Occlusion or flow deterioration of SB spanned by the ST is relatively common during repeat intervention for in-ST restenosis. Several factors (mainly anatomic features) are useful predictors of this event. However, most SB occlusions are clinically silent and frequently reappear at follow-up.

Adult↗

Stenting the stent: initial results and long-term clinical and angiographic outcome of coronary stenting for patients with in-stent restenosis.

Stent restenosis constitutes a therapeutic challenge affecting an increasing number of patients. Conventional angioplasty and debulking techniques are currently used in these patients. However, the potential role of a second stent implantation in this setting (stenting the stent) remains unknown. Therefore, 65 consecutive patients (12 women, aged 62 +/- 11 years) undergoing stent implantation (42 elective and 23 unplanned) for the treatment of in-stent restenosis (diffuse [> 10 mm] in 39 [60%]) were studied. Angiographic success was obtained in all patients. Three patients developed hospital complications: 1 died from refractory heart failure and 2 suffered non-Q-wave myocardial infarctions. During follow-up (mean 17 +/- 11 months) 1 patient died (noncardiac cause) and only 9 (14%) required target vessel revascularization. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and target vessel revascularization) at 1 year was 84%. Using Cox analysis, patients with unstable symptoms, a short time to stent restenosis, nonelective stenting, and B2-C lesions tended to have poorer prognosis. After adjustment, nonelective stenting was associated (adjusted RR 2.9, 95% confidence interval [CI] 0.82 to 10.3, p = 0.09) with an adverse clinical outcome. On quantitative angiography (core lab) restenosis was found in 13 of 43 patients (30%) (75% of those eligible). Logistic regression analysis identify restenosis length (adjusted RR 1.43, 95% CI 1.04 to 2.14, p = 0.04), and time to restenosis (adjusted RR 0.67, 95% CI 0.47 to 0.94, p = 0.01) as the only independent predictors of recurrent restenosis. Thus, repeat coronary stenting is a safe and efficacious strategy for the treatment of patients with in-stent restenosis. Both elective and nonelective stenting provide excellent initial results. The long-term clinical and angiographic outcome of these patients is also favorable.

Coronary Angiography↗

Pressure wire kinking, entanglement, and entrapment during intravascular ultrasound studies: a potentially dangerous complication.

The simultaneous use of intravascular ultrasound catheters and sensor-tipped guidewires is gaining acceptance during coronary interventions as a means to gain further insights on the significance of coronary stenoses. Herein we describe four patients in whom the distal tip of the pressure wire became entrapped during an intravascular ultrasound examination. In the four patients, a localized kinking of the pressure wire initially prevented the removal of the imaging catheter and eventually the wire-catheter assembly had to be retrieved as a unit into the guiding catheter. In one patient, unraveling of the distal part of the pressure wire was noticed. In two patients, a complete loop with further kinking of the pressure wire was induced during the maneuvers performed to withdraw the imaging system. Three patients experienced transient angina. Although in our patients this technical problem was not associated with any clinical sequelae, interventional cardiologists should be aware of the potential complications associated with the combined use of these two intracoronary diagnostic tools.

Cardiac Catheterization↗

Guidewire-induced coronary pseudostenosis as a source of error during physiological guidance of stent deployment.

Coronary pseudostenoses are a known result of the interaction between tortuous vessels and guidewires and are generally handled by the interventionalist as inocuous side effects of intracoronary instrumentation. The present report demonstrates that pseudostenosis may have hemodynamic relevance and may constitute an important source of error when physiological guidance of percutaneous procedures is performed using sensor-tipped guidewires.

Aged↗

[Aspiration of large intracoronary thrombus after apparently successful angioplasty. Therapeutic implications].

We present a case in which, after performing an optimal angioplasty after an acute myocardial infarction with intracoronary thrombus, normal coronary flow was not achieved. After aspirating through the guiding catheter we obtained a large thrombus that the histopathologic study confirmed as a recent thrombus and, subsequently, normal flow was reestablished. The procedure was completed with a successful intracoronary stent implantation, with an uneventful clinical course. The therapeutic and diagnostic implications of this case are discussed.

Aged↗

Successful sealing of an angioplasty-related saphenous vein graft rupture with a PTFE-covered stent.

A patient developed severe hemodynamic compromise after saphenous vein graft rupture during high-pressure coronary stent deployment. Immediate balloon inflation followed by implantation of a polytetrafluoroethylene-covered stent solved the problem. The next day, follow-up angiography confirmed persistent sealing of the rupture site. Clinical and angiographic features of vessel rupture during coronary angioplasty as well as several therapeutic options for this complication are discussed.

Aged↗

Propensity and mechanisms of restenosis in different coronary stent designs: complementary value of the analysis of the luminal gain-loss relationship.

OBJECTIVES: This study sought to investigate the influence of stent design on the long-term angiographic outcome. BACKGROUND: The proportional relationship between vessel injury and late luminal loss in percutaneous revascularization should be best appreciated in coronary stenting, where recoil and shrinkage are theoretically minimal. It is unclear whether all stent designs can counterbalance this reactive loss by achieving a large initial luminal gain (bigger is better). METHODS: In 523 lesions successfully stented, the long-term angiographic results of slotted-tube (n = 331), coil (n = 85), multicellular (n = 70) and self-expandable mesh (n = 37) stent designs were compared using the angiographic gain-loss relationship (GLR). RESULTS: Restenosis rate was 10% for multicellular, 20% for slotted-tube, 46% for coil and 49% for self-expandable designs (p = 0.001). At a difference with other designs, no significant GLR was found in coil stents, suggesting additional mechanisms of luminal loss (i.e., plaque protrusion, stent compression) to neointimal proliferation. Significant differences in late loss between stents were found within each quartile of luminal gain, suggesting a specific role of design in luminal loss. Multivariate analysis identified use of coil and self-expandable stents, vessel size, minimal luminal diameter preintervention, luminal gain and stent length as variables with independent predictive value for several indices of angiographic long-term outcome. CONCLUSIONS: The analysis of GLR: 1) demonstrates that stent design influences late luminal loss; 2) challenges the applicability of the widely accepted "bigger is better" approach to all stent designs; and 3) appears as a valuable tool in assessing long-term stent performance.

Coronary Angiography↗

Results (>6 months) of stenting of >1 major coronary artery in multivessel coronary artery disease.

Multivessel percutaneous transluminal coronary angioplasty (PTCA) is associated with a high requirement for further revascularization procedures. Although stenting can reduce restenosis and clinical events after 1-vessel intervention, little information is available after multivessel coronary stenting. We followed up 136 patients (9% of 1,481 undergoing stenting in our center) who had had stent implantation in at least 2 different major native coronary arteries and were followed-up for >6 months. Each patient had received a mean of 2.3 +/- 0.6 stents (1.13 +/- 0.4 stents per lesion) and procedural success was 95%. In-hospital complications included 1 death, 1 Q-wave infarction, 5 non-Q-wave myocardial infarctions, and 1 repeat PTCA. After a mean of 18 +/- 13 months, 7 patients died (3 of heart failure, 4 of noncardiac causes), 2 required coronary bypass surgery, 1 had a myocardial infarction, 13 target vessel repeat PTCA, and 4 non-target vessel PTCA. Survival free of major cardiac events was 75% at 3 years. A history of heart failure, dilation of a restenotic lesion, and 3-vessel dilation were independent negative predictors of event-free survival. Angiographic follow-up was available in 86 patients: 56 (65%) were restenosis free, 23 (27%) had 1-vessel restenosis, and 6 (7%) had 2-vessel and 1 patient 3-vessel restenosis. Restenosis per vessel was 23% (41 of 177). Reference diameter, past-PTCA minimal luminal diameter, and length of the stent were independent predictors of restenosis. We conclude that multivessel stenting provides good midterm results in selected patients with multivessel coronary artery disease. Midterm events are less frequent than previously reported after balloon PTCA.

Angioplasty, Balloon, Coronary↗

Catheter-based reperfusion of unprotected left main stenosis during an acute myocardial infarction (the ULTIMA experience). Unprotected Left Main Trunk Intervention Multi-center Assessment.

The ULTIMA registry was a prospective, multicenter, international registry of 277 patients who underwent percutaneous coronary interventions of unprotected left main trunk stenosis. The 40 patients who underwent an emergency percutaneous left main intervention for acute myocardial infarction are the focus of this study. We compared the results of primary angioplasty with primary stenting, characterizing both the short-term (in-hospital) and long-term (12-month) outcomes. Of the 40 patients, 23 underwent primary angioplasty, whereas 17 underwent primary stenting. The angiographic success rate was an 88% for the cohort. The in-hospital death or coronary artery bypass grafting rate was 65% for the entire group, 74% for the percutaneous transluminal coronary angioplasty group (PTCA), and 53% for the stent group (p = 0.2). The in-hospital death rate was 55% for the entire cohort, 70% for the PTCA group, and 35% for the stent group (p = 0.1). The 12-month rate of death or bypass surgery was 83% and 58% for the PTCA and stent groups, respectively (p = 0.047). The 12-month survival rate was 35% and 53% for the PTCA and stent groups, respectively (p = 0.18). Bypass surgery was required in 6 patients in the PTCA group and 2 patients in the stent group (p = 0.07). Patients undergoing percutaneous interventions for unprotected left main myocardial stenosis during an acute myocardial infarction are critically ill; an initial percutaneous revascularization approach appears feasible and may be the preferred revascularization strategy. Primary stenting was associated with improved clinical outcomes.

Aged↗