Search PubMed⌕ Search

Biomedical subjects

C MacAulay

Publications and source records attributed to C MacAulay.

32 records · Page 2Linked to original sources

Use of high-resolution cytometry in predicting the biologic behavior of T1 adenocarcinoma of the lung.

Touch preparations from 60 cases of T1 adenocarcinoma were analyzed using a high-resolution, automated image cytometer. These cases were divided according to pathologic stage: stage I, 31; stage II, 3; stage III, 19; and stage IV, 7. For each nucleus 57 features were analyzed, and using a linear combination of three texture features describing the DNA distribution in the cell nucleus (TARL, ODMAX and FAREA1), aggressive cancer cells belonging to stage III/IV could be identified. The best discrimination between the stages was achieved when the frequency of aggressive cancer cells was 48%; the correct classification rate was 77%. Using this criterion, 22 of 27 patients (81%) who died of cancer within five years after surgery were correctly predicted. These results suggest that high-resolution cytometry may be of value in predicting the biologic behavior of adenocarcinoma cases, especially in stage I/II.

Adenocarcinoma↗

Malignancy associated changes in cervical smears: systematic changes in cytometric features with the grade of dysplasia.

For almost ten years. Malignancy Associated Changes have been consistently found by means of high resolution image analysis of apparently normal uterine cervix cells. The study was performed on normal intermediate cells randomly selected from 1850 cervical smear slides classified as negative, mild dysplasia, moderate dysplasia and severe dysplasia. Size and texture features, performed by the Cyto-Savant software, have shown significant monotonic changes with the grade of dysplasia. These findings indicate that the intensity of Malignancy Associated Changes are directly related to the severity of the adjacent lesions.

Cell Transformation, Neoplastic↗

Probabilistic inference in computer-aided screening for cervical cancer: an event covering approach to information extraction and decision rule formulation.

A pattern analysis approach called event covering is introduced and applied to the problem of determining the significance of measured morphological attributes of cervical cells in an automated screening process. The approach is shown to be effective in deciding which characteristics at the event (outcome) level are of little or no diagnostic value, and in formulating sets of predictive rules using the most pertinent ones.

Adult↗

A computerized autofluorescence and diffuse reflectance spectroanalyser system for in vivo skin studies.

A microcomputer-controlled spectroanalyser system has been set up to study optical properties of normal and abnormal human skin in vivo. The system can measure both tissue autofluorescence and diffuse reflectance at selected skin locations. The sample holder allows adjustment of the incident angle of the illumination light and the pick-up angle of the collected light providing the means to examine different depths of skin tissue. Using this system, we detected measurable skin autofluorescence with a maximum at about 470 nm when excited with 380 nm UV radiation. In this work, we also show that the absorption and scattering properties of the skin tissue (which can be determined from the measured diffuse reflectance spectrum) affect the shape of the autofluorescence spectrum. We believe that the combination of autofluorescence and diffuse reflectance measurements will lead to better understanding of the optical properties of normal and abnormal skin tissue.

Computer Systems↗

Detection and localization of early lung cancer by imaging techniques.

Two new technologic developments may have a significant impact on the detection and localization of early lung cancer. These two developments work together in a complementary way. The first is a solid-state microscope that can be applied in the prescreening of sputum cytology specimens. The finding that malignancy-associated changes (MACs) are present in ostensibly normal bronchial epithelial cells may be used to improve the sensitivity of sputum cytology to detect cancer. Once abnormal or MAC cells are found, a second device, a fluorescence bronchoscope, can be employed to localize the source of the abnormal cells. Fluorescence bronchoscopy is also a potentially useful tool for procuring premalignant tissue for molecular biology studies and for monitoring the progress of patients in chemoprevention studies.

Bronchoscopy↗

Detection of dysplasia and carcinoma in situ with a lung imaging fluorescence endoscope device.

The performance of a novel bronchoscopic fluorescence imaging system was compared with conventional white light bronchoscopy with a data base of 328 biopsy-confirmed sites from 53 patients and 41 volunteers. The two methods were found to have the same specificity (94%); however, the sensitivity of the fluorescence system (72.5%) was found to be 50% greater than that of the white light bronchoscopy (48.4%) in detecting dysplasia and carcinoma in situ. The fluorescence system uses a nonlinear discriminant function combining the red and green image intensity values to form a pseudoimage that, when displayed on an RGB monitor, allows the detection and delineation of abnormal areas. In 15% of the patients with lung cancer, synchronous carcinoma in situ was found in addition to the large invasive cancer. Of the current smokers in this study, 40% had moderate dysplasia and 12% had severe dysplasia. For the ex-smokers 25% had moderate dysplasia, 6% had severe dysplasia, and 13% had carcinoma in situ. Fluorescence imaging may become an important adjunct to conventional bronchoscopic examination to improve our ability to diagnose and stage lung cancer more accurately.

Aged↗

Comparison of three different methods for automated classification of cervical cells.

Over 4600 exfoliated squamous cervical cells taken from appropriate Papanicolaou samples were classified as normal, mildly dysplastic, moderately dysplastic and severely dysplastic by an experienced cytopathologist. The slides were de-stained and subsequently re-stained with Feulgen Thionin-SO2 stain. Images of the nuclei were then captured, recorded and processed employing an image cytometry device. Automated classification of the cells was carried out using three different methods--discriminant function analysis, a decision tree classifier and a neutral network classifier. The discriminant function analysis method, which combined all dysplastic cells into an abnormal group, achieved a combined error rate of less than 0.4% for moderate and severe dysplastic cells, and less than 40% for mildly dysplastic cells. All three methods yielded comparable results, which approached those of human performance.

Cell Nucleus↗

Fractal texture features based on optical density surface area. Use in image analysis of cervical cells.

The spatial distribution of the optical density of an image of a cell nucleus can be imagined to resemble a rugged surface in a three-dimensional space. The area of this surface can be measured using different unit-sized squares, yielding different values for the total area depending on the unit size. A fractal dimension can be calculated from the relationship between the unit size and the overall area measured; this fractal dimension is characteristic of the surface measured. This technique was applied to extract three new nuclear features from stained cervical cells. These new features were useful for the computer discrimination of normal and premalignant cervical cells. The features are defined, and their discriminating power is compared to that of some other nuclear features.

Cell Membrane↗

An edge relocation segmentation algorithm.

An automated procedure that refines the nuclear contour of a previously segmented nucleus is described. The algorithm makes use of intensity information, edge magnitude information and both object and edge connectivity information. This automated procedure generates a closed contour precisely along the edge of the nucleus. The procedure was tested on a database of 3,680 red-green-blue images of thionin-SO2 and orange II-stained cervical cells obtained from normal and dysplastic samples. When used in conjunction with a simple threshold selection algorithm and an artifact removal routine, this edge relocation algorithm resulted in the correct segmentation of over 98% of the nuclei. Only 63 (1.7%) of all nuclei were incorrectly segmented.

Algorithms↗

Adaptive color basis transformation. An aid in image segmentation.

Multispectral images of stained cells enable the use of color differences to segment and/or to discriminate between image components, such as cell types and cellular subcomponents. When the spectral characteristics of the image components do not change over the area of a slide or from slide to slide, one can create a constant weighted linear combination of spectral images to generate one-dimensional or two-dimensional images that have the desired contrast between the image components that must be discriminated. However, when the spectral characteristics are not constant, i.e., when they vary from image to image, a constant weighted linear combination cannot be employed; instead, an appropriate solution must be found for each selected image. This is usually a time-consuming, manual procedure that cannot be employed in a fully automated process of discriminating and segmenting stained cells. This paper describes an algorithm that uses principal components decomposition basis vectors to generate a nonstatic weighted linear combination of color images that can be used by an automated system. This algorithm relies on a semiconstant relationship between the areas (sizes) of the image components that are to be discriminated and/or segmented. The technique has been successfully applied as an aid in the segmentation of images of stained cervical smears; the images were acquired with a three-chip CCD camera that generates three broad-band color images.

Algorithms↗

Imaging system for morphometric assessment of absorption or fluorescence in stained cells.

An image acquisition and processing system has been developed for quantitative microscopy of absorption or fluorescence in stained cells. Three different light transducers are used in the system to exploit the best characteristics of these sensors for different biological measurements. A digital scanner, in the form of a linear array charge-coupled device (CCD), acquires data with high spatial and photometric resolution. A color (RGB) camera is employed when spectral information is required for the segmentation of cellular subcomponents. An image-intensified charged-injection device (CID) camera provides for very low light intensity measurements, primarily for fluorescence-labeled cells. Properties of these transducers, such as contrast transfer function, linearity, and photo-response nonuniformity, have been measured. Two dedicated image processing units were incorporated into the system. The front-end processor, based on a digital signal processor, provides functions such as object detection, raw image calibration, compression, artifact removal, and filtering. The second image processor is associated with the frame memory and includes a histogram processor, a dedicated arithmetic logic unit for image processing functions, and a graphics module for one-bit overlay functions. An interactive program was developed to acquire cell images and to experiment with a range of segmentation algorithms, feature extractions, and other image processing functions. The results of any image operation are displayed on the video monitor. Once a desired processing sequence is determined, the sequence may be stored to become part of a command library and can be executed thereafter as a single instruction.

Algorithms↗

A comparison of some quick and simple threshold selection methods for stained cells.

The segmentation accuracy of four fast and simple gray-scale threshold selection methods were compared using a data base of stained cervical cell images. Some postprocessing was applied to the segmented images to increase the accuracy of the nuclear segmentation. The most accurate method correctly segmented the cytoplasm of 81% of the cell images and the nuclei of 78% of the cell images in the data base.

Algorithms↗

A pilot study for a screening trial of cervical fluorescence spectroscopy.

Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. In preparation for a multicenter phase II screening trial, a pilot trial was conducted to test data collection and patient examination procedures, use data forms, time procedures, and identify problems with preliminary data analysis. Women 18 years of age and older underwent a questionnaire, a complete history, and a physical examination, including a pan-colposcopy of the lower genital tract. A fiber-optic probe measured fluorescence excitation-emission matrices at 1-3 cervical sites for 58 women. The data collection procedures, data forms, and procedure times worked well, although collection times for all the clinical data take an average of 28 min. The clinical team followed procedures well, and the data could be retrieved from the database at all sites. The multivariate analysis algorithm correctly identified squamous normal tissue 99% of the time and columnar normal tissue only 7%. The assessment of ploidy from monolayer samples was not accurate in this small sample. The study was successful as a pilot trial. We learned who participated, who withdrew, how often abnormalities were present, and that algorithms that have worked extremely well in previous studies do not work as well when a few study parameters are changed. The current algorithm for diagnosis identified squamous normal tissue very accurately and did less well for columnar normal tissue. Inflammation may be an explanation for this phenomenon. Fluorescence spectroscopy is a promising technology for the detection of epithelial precancers and cancers. The screening trial of fluorescence and reflectance spectroscopy was successful.

Adult↗