Search PubMed⌕ Search

Biomedical subjects

C M Ma

Publications and source records attributed to C M Ma.

At least 37 records · Page 2Linked to original sources

Five saponins from the root bark of Aralia elata.

Five saponins, 3-O-[beta-D-glucopyranosyl (1-->2)-[beta-D-glucopyranosyl (1-->3)]-beta-D-glucopyranosyl]-oleanolic acid 28-O-beta-D-glucopyranosyl ester (aralia-saponin V), 3-O-[beta-D-glucopyranosyl (1-->2)-[beta-D-glucopyranosyl (1-->3)]-beta-D-glucopyranosyl]-echinocystic acid 28-O-beta-D-glucopyranosyl ester (aralia-saponin VI), 3-O-beta-D-glucopyranosyl (1-->2)-[beta-D-glucopyranosyl (1-->3)]-beta-D-glucopyranosyl]-hederagenin 28-O-beta-D-glucopyranosyl ester (aralia-saponin VII), 3-O-[beta-D-glucopyranosyl-(1-->3)-beta-D-glucopyranosyl-(1-->3)-[beta-D-glucopyranosyl-(1-->2)]-beta-D-glucopyranosyl]-caulophyllogenin 28-O-beta-D-glucopyranosyl ester (aralia-saponin VIII), 3-O-[beta-D-glucopyranosyl (1-->2)-[beta-D-glucopyranosyl(1-->3)]-alpha-L-arabinopyranosyl]-hederagenin 28-O-beta-D-glucopyranosyl ester (aralia-saponin IX), were isolated from the root bark of Aralia elata (Miq.) Seem., together with four known compounds. Their structures were determined on the basis of chemical and spectroscopic methods.

Magnoliopsida↗

Monte Carlo simulation for MLC-based intensity-modulated radiotherapy.

This article describes photon beam Monte Carlo simulation for multi leaf collimator (MLC)-based intensity-modulated radiotherapy (IMRT). We present the general aspects of the Monte Carlo method for the non-Monte Carloist with an emphasis given to patient-specific radiotherapy application. Patient-specific application of the Monte Carlo method can be used for IMRT dose verification, inverse planning, and forward planning in conventional conformal radiotherapy. Because it is difficult to measure IMRT dose distributions in heterogeneous phantoms that approximate a patient, Monte Carlo methods can be used to verify IMRT dose distributions that are calculated using conventional methods. Furthermore, using Monte Carlo as the dose calculation method for inverse planning results in better-optimized treatment plans. We describe both aspects and present our recent results to illustrate the discussion. Finally, we present current issues related to clinical implementation of Monte Carlo dose calculation. Monte Carlo is the most recent, and most accurate, method of radiotherapy dose calculation. It is currently in the process of being implemented by various treatment planning vendors and will be available for clinical use in the immediate future.

Humans↗

The MLC tongue-and-groove effect on IMRT dose distributions.

We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles (> or = 5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan (> or = 5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (< 5) will vary depending on the number of fields in a plan (coplanar or non-coplanar), the MLC leaf sequences and the patient setup uncertainty, and may be significant (> 5% of maximum dose) in some cases, especially when the patient setup uncertainty is small (< or = 2 mm).

Bone Neoplasms↗

Derivation of electron and photon energy spectra from electron beam central axis depth dose curves.

A method for deriving the electron and photon energy spectra from electron beam central axis percentage depth dose (PDD) curves has been investigated. The PDD curves of 6, 12 and 20 MeV electron beams obtained from the Monte Carlo full phase space simulations of the Varian linear accelerator treatment head have been used to test the method. We have employed a 'random creep' algorithm to determine the energy spectra of electrons and photons in a clinical electron beam. The fitted electron and photon energy spectra have been compared with the corresponding spectra obtained from the Monte Carlo full phase space simulations. Our fitted energy spectra are in good agreement with the Monte Carlo simulated spectra in terms of peak location, peak width, amplitude and smoothness of the spectrum. In addition, the derived depth dose curves of head-generated photons agree well in both shape and amplitude with those calculated using the full phase space data. The central axis depth dose curves and dose profiles at various depths have been compared using an automated electron beam commissioning procedure. The comparison has demonstrated that our method is capable of deriving the energy spectra for the Varian accelerator electron beams investigated. We have implemented this method in the electron beam commissioning procedure for Monte Carlo electron beam dose calculations.

Algorithms↗

Monte Carlo based treatment planning for modulated electron beam radiation therapy.

A Monte Carlo based treatment planning system for modulated electron radiation therapy (MERT) is presented. This new variation of intensity modulated radiation therapy (IMRT) utilizes an electron multileaf collimator (eMLC) to deliver non-uniform intensity maps at several electron energies. In this way, conformal dose distributions are delivered to irregular targets located a few centimetres below the surface while sparing deeper-lying normal anatomy. Planning for MERT begins with Monte Carlo generation of electron beamlets. Electrons are transported with proper in-air scattering and the dose is tallied in the phantom for each beamlet. An optimized beamlet plan may be calculated using inverse-planning methods. Step-and-shoot leaf sequences are generated for the intensity maps and dose distributions recalculated using Monte Carlo simulations. Here, scatter and leakage from the leaves are properly accounted for by transporting electrons through the eMLC geometry. The weights for the segments of the plan are re-optimized with the leaf positions fixed and bremsstrahlung leakage and electron scatter doses included. This optimization gives the final optimized plan. It is shown that a significant portion of the calculation time is spent transporting particles in the leaves. However, this is necessary since optimizing segment weights based on a model in which leaf transport is ignored results in an improperly optimized plan with overdosing of target and critical structures. A method of rapidly calculating the bremsstrahlung contribution is presented and shown to be an efficient solution to this problem. A homogeneous model target and a 2D breast plan are presented. The potential use of this tool in clinical planning is discussed.

Electrons↗

Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation.

A simple analytical approach has been developed to model extrafocal radiation and monitor chamber backscatter for clinical photon beams. Model parameters for both the extrafocal source and monitor chamber backscatter are determined simultaneously using conventional measured data, i.e., in-air output factors for square and rectangular fields defined by the photon jaws. The model has been applied to 6 MV and 15 MV photon beams produced by a Varian Clinac 2300C/D accelerator. Contributions to the in-air output factor from the extrafocal radiation and monitor chamber backscatter, as predicted by the model, are in good agreement with the measurements. The model can be used to calculate the in-air output factors analytically, with an accuracy of 0.2% for symmetric or asymmetric rectangular fields defined by jaws when the calculation point is at the isocenter and 0.5% when the calculation point is at an extended SSD. For MLC-defined fields, with the jaws at the recommended positions, calculated in-air output factors agree with the measured data to within 0.3% at the isocenter and 0.7% at off-axis positions. The model has been incorporated into a Monte Carlo dose algorithm to calculate the absolute dose distributions in patients or phantoms. For three MLC-defined irregular fields (triangle shape, C-shape, and L-shape), the calculations agree with the measurements to about 1% even for points at off-axis positions. The model will be particularly useful for IMRT dose calculations because it accurately predicts beam output and penumbra dose.

Biophysical Phenomena↗

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology (40 kV < or = tube potential < or = 300 kV). It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in-air measurement (the "in-air" method). If the point of interest is at a depth, an in-water measurement at a depth of 2 cm shall be used for tube potentials > or = 100 kV (the "in-phantom" method). The in-phantom method is not recommended for tube potentials < 100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up-to-date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.

Air↗

Verification of IMRT dose distributions using a water beam imaging system.

A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation image was captured by the camera. The pixel value in this image indicated the dose value in the scintillation screen. Images of radiation fields of known spatial distributions were used to calibrate the device. The verification was performed by comparing the image acquired from the measurement with a dose distribution from the IMRT plan. Because of light scattering in the scintillator screen, the image was blurred. A correction for this was developed by recognizing that the blur function could be fitted to a multiple Gaussian. The blur function was computed using the measured image of a 10 cm x 10 cm x-ray beam and the result of the dose distribution calculated using the Monte Carlo method. Based on the blur function derived using this method, an iterative reconstruction algorithm was applied to recover the dose distribution for an IMRT plan from the measured WBIS image. The reconstructed dose distribution was compared with Monte Carlo simulation result. Reasonable agreement was obtained from the comparison. The proposed approach makes it possible to carry out a real-time comparison of the dose distribution in a transverse plane between the measurement and the reference when we do an IMRT dose verification.

Calibration↗

Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system.

Therapeutic treatment plan evaluation is often based on examining the radiotherapy treatment planning (RTP) system dose distributions in the target and surrounding normal structures. To study the effects of tissue inhomogeneities on photon dose distributions, we compared FOCUS RTP system dose distributions from the measurement-based Clarkson and model-based MultiGrid Superposition (MGS) algorithms with those from the BEAM Monte Carlo code system in a set of heterogeneous phantoms. The phantom inhomogeneities mimic relevant clinical treatment sites, which include lung slab, lung-bone slab, bone-lung slab, mediastinum, and tumor geometries. The benchmark comparisons were performed in lung densities of 0.20 and 0.31 g/cm3, and a bone density of 2.40 g/cm3 for 5x5 cm2 and 10x10 cm2, 6- and 15-MV photon beams. Benchmark comparison results show that the MGS model and BEAM doses match better than 3% or 3 mm, and the MGS model is more accurate than the Clarkson model in all phantoms. The MGS model, unlike the Clarkson model, predicts the build-down and build-up of dose near tissue interfaces and penumbra broadening in lung associated with high energy beams. The Clarkson model overestimates the dose in lung by a maximum of 10% compared to BEAM. Dose comparisons suggest turning-off the effective path length inhomogeneity correction in the Clarkson model for lung treatments.

Algorithms↗

Triterpenes and lignans from Artemisia caruifolia and their cytotoxic effects on meth-A and LLC tumor cell lines.

One new triterpene, 3beta-hydroxy-29-norcycloart-24-one (1), and four new lignans, caruilignans (2-5), together with six known compounds were isolated from the aerial part of Artemisia caruifolia BUCH.-HAM. ex TOXB. Their structures were determined by various spectroscopic means. Most of the isolated lignans were moderately cytotoxic to Meth-A cells with ED50 values of 5-10 microg/ml, but not to Lowis lung carcinoma (LLC) cells. An oxime derivative of 1 showed more potent cytotoxic activity against Meth-A and LLC cells than the original triterpene 1.

Antineoplastic Agents, Phytogenic↗

Kaempferol acetylrhamnosides from the rhizome of Dryopteris crassirhizoma and their inhibitory effects on three different activities of human immunodeficiency virus-1 reverse transcriptase.

Three new kaempferol glycosides, called crassirhizomosides A (1), B (2) and C (3), were isolated from the rhizome of Dryopteris crassirhizoma (Aspidiaceae), together with the known kaempferol glycoside, sutchuenoside A (4). The structures of 1-3 were determined as kaempferol 3-alpha-L-(2,4-di-O-acetyl)rhamnopyranoside-7-alpha-L-rhamnopyranoside, kaempferol 3-alpha-L-(3,4-di-O-acetyl)rhamnopyranoside, and kaempferol 3-alpha-L-(2,3-di-O-acetyl)rhamnopyranosside-7-alpha-L-rhamnopyranoside, respectively, by chemical and spectroscopic means. Inhibitory effects of 1-4 and kaempferol on human immunodeficiency virus reverse transcriptase-associated DNA polymerase (RNA-dependent DNA polymerase and DNA-dependent DNA polymerase) and RNase H activities were investigated.

Carbohydrates↗

Inhibitory effects on HIV-1 protease of tri-p-coumaroylspermidine from Artemisia caruifolia and related amides.

From a methanol extract of Artemisia caruifolia, which showed a moderate inhibitory activity on HIV-1 protease in a preliminary screening, N1,N5,N10-tri-p-coumaroylspermidine and three dicaffeoylquinic acids were isolated. The former compound was found to appreciably inhibit HIV-1 protease. Of related amides which were chemically synthesized, N1,N5,N10,N14-tetra-p-coumaroylspermine and N1,N4,N7,N10,N13-penta-p-coumaroylte-traethylenepentamine inhibited HIV-1 protease more potently than N1,N5,N10-tri-p-coumaroylspermidine.

Amides↗

Monte Carlo characterization of clinical electron beams in transverse magnetic fields.

Monte Carlo simulations were employed to study the characteristics of the electron beams of a clinical linear accelerator in the presence of 1.5 and 3.0 T transverse magnetic fields and to assess the possibility of using magnetic fields in conjunction with modulated electron radiation therapy (MERT). The starting depth of the magnetic field was varied over several centimetres. It was found that peak doses of as much as 2.7 times the surface dose could be achieved with a 1.5 T magnetic field. The magnetic field was shown to reduce the 80% and 20% dose drop-off distance by 50% to 80%. The distance between the 80% dose levels of the pseudo-Bragg peak induced by the magnetic field was found to be extremely narrow, generally less than 1 cm. However, by modulating the energy and intensity of the electron fields while simultaneously moving the magnetic field, a homogeneous dose distribution with low surface dose and a sharp dose fall-off was generated. Heterogeneities are shown to change the effective range of the electron beams, but not eliminate the advantages of a sharp depth dose drop-off or high peak-to-surface dose ratio. This suggests the applicability of MERT with magnetic fields in heterogeneous media. The results of this study demonstrate the ability to use magnetic fields in MERT to produce highly desirable dose distributions.

Algorithms↗

Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning.

A new EGS4/PRESTA Monte Carlo user code, MCDOSE, has been developed as a routine dose calculation tool for radiotherapy treatment planning. It is suitable for both conventional and intensity modulated radiation therapy. Two important features of MCDOSE are the inclusion of beam modifiers in the patient simulation and the implementation of several variance reduction techniques. Before this tool can be used reliably for clinical dose calculation, it must be properly validated. The validation for beam modifiers has been performed by comparing the dose distributions calculated by MCDOSE and the well-benchmarked EGS4 user codes BEAM and DOSXYZ. Various beam modifiers were simulated. Good agreement in the dose distributions was observed. The differences in electron cutout factors between the results of MCDOSE and measurements were within 2%. The accuracy of MCDOSE with various variance reduction techniques was tested by comparing the dose distributions in different inhomogeneous phantoms with those calculated by DOSXYZ without variance reduction. The agreement was within 1.0%. Our results demonstrate that MCDOSE is accurate and efficient for routine dose calculation in radiotherapy treatment planning, with or without beam modifiers.

Bone and Bones↗

Photon beam characterization and modelling for Monte Carlo treatment planning.

Photon beams of 4, 6 and 15 MV from Varian Clinac 2100C and 2300C/D accelerators were simulated using the EGS4/BEAM code system. The accelerators were modelled as a combination of component modules (CMs) consisting of a target, primary collimator, exit window, flattening filter, monitor chamber, secondary collimator, ring collimator, photon jaws and protection window. A full phase space file was scored directly above the upper photon jaws and analysed using beam data processing software, BEAMDP, to derive the beam characteristics, such as planar fluence, angular distribution, energy spectrum and the fractional contributions of each individual CM. A multiple-source model has been further developed to reconstruct the original phase space. Separate sources were created with accurate source intensity, energy, fluence and angular distributions for the target, primary collimator and flattening filter. Good agreement (within 2%) between the Monte Carlo calculations with the source model and those with the original phase space was achieved in the dose distributions for field sizes of 4 cm x 4 cm to 40 cm x 40 cm at source surface distances (SSDs) of 80-120 cm. The dose distributions in lung and bone heterogeneous phantoms have also been found to be in good agreement (within 2%) for 4, 6 and 15 MV photon beams for various field sizes between the Monte Carlo calculations with the source model and those with the original phase space.

Models, Theoretical↗

Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations.

Dose-volume histograms (DVHs) of the dose distributions calculated by the Monte Carlo method contain statistical uncertainties. The Monte Carlo DVH can be considered as blurred from the noiseless DVH by the statistical uncertainty. The focus of the present work is on the removal of the statistical uncertainty effect on the Monte Carlo DVHs and the reconstruction of the noiseless DVHs. We first study the effect of statistical uncertainty. It is found that the steeper the DVH, the more significant the effect. For typical critical structure DVHs the effect is usually negligible. For the target DVHs the effect could be clinically significant, depending on the value of uncertainty and the slope of the DVH. We then propose an iterative reconstruction algorithm. Using the DVHs and statistical uncertainties from the Monte Carlo simulations, we are able to reconstruct the noiseless DVHs. A hypothetical example and a number of clinical cases have been used to test the proposed algorithm. For each clinical case, two Monte Carlo simulations (denoted A and B) were performed. Simulation A has very large statistical uncertainties (about 10% of dose in the target volume) while simulation B has very small uncertainties (about 1%). DVHs from simulation B were used to approximate the noiseless DVHs. Using the proposed algorithm, the effect of statistical uncertainty can be removed from the DVHs of simulation A. The reconstructed DVHs were in good agreement with the DVHs from simulation B. The proposed approach is expected to be useful in removing the blurring effect on a quickly calculated Monte Carlo DVH when performing the iterative forward treatment planning.

Algorithms↗

Energy- and intensity-modulated electron beams for radiotherapy.

This work investigates the feasibility of optimizing energy- and intensity-modulated electron beams for radiation therapy. A multileaf collimator (MLC) specially designed for modulated electron radiotherapy (MERT) was investigated both experimentally and by Monte Carlo simulations. An inverse-planning system based on Monte Carlo dose calculations was developed to optimize electron beam energy and intensity to achieve dose conformity for target volumes near the surface. The results showed that an MLC with 5 mm leaf widths could produce complex field shapes for MERT. Electron intra- and inter-leaf leakage had negligible effects on the dose distributions delivered with the MLC, even at shallow depths. Focused leaf ends reduced the electron scattering contributions to the dose compared with straight leaf ends. As anticipated, moving the MLC position toward the patient surface reduced the penumbra significantly. There were significant differences in the beamlet distributions calculated by an analytic 3-D pencil beam algorithm and the Monte Carlo method. The Monte Carlo calculated beamlet distributions were essential to the accuracy of the MERT dose distribution in cases involving large air gaps, oblique incidence and heterogeneous treatment targets (at the tissue-bone and bone-lung interfaces). To demonstrate the potential of MERT for target dose coverage and normal tissue sparing for treatment of superficial targets, treatment plans for a hypothetical treatment were compared using photon beams and MERT.

Algorithms↗

Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system.

The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically to improve and verify the accuracy of radiotherapy dose calculations. Further modifications to the system were made to compute the dose in a patient for multiple fixed-gantry IMRT fields. The dose distributions in the experimental phantoms and in the patients were calculated and used to verify the optimized treatment plans generated by the Corvus system. The Monte Carlo calculated IMRT dose distributions agreed with the measurements to within 2% of the maximum dose for all the beam energies and field sizes for both the homogeneous and heterogeneous phantoms. The dose distributions predicted by the Corvus system, which employs a finite-size pencil beam (FSPB) algorithm, agreed with the Monte Carlo simulations and measurements to within 4% in a cylindrical water phantom with various hypothetical target shapes. Discrepancies of more than 5% (relative to the prescribed target dose) in the target region and over 20% in the critical structures were found in some IMRT patient calculations. The FSPB algorithm as implemented in the Corvus system is adequate for homogeneous phantoms (such as prostate) but may result in significant under or over-estimation of the dose in some cases involving heterogeneities such as the air-tissue, lung-tissue and tissue-bone interfaces.

Computer Simulation↗