Search PubMed⌕ Search

Biomedical subjects

C L de Korte

Publications and source records attributed to C L de Korte.

21 records · Page 2Linked to original sources

Intravascular elastography: principles and potentials.

Many intravascular therapeutic techniques for the treatment of significant atherosclerotic lesions are mechanical in nature: angioplasty, stenting and atherectomy. The selection of the most adequate treatment would be advantageously aided by knowledge of the mechanical properties of the lesion. Based on the success of conventional intravascular ultrasound (IVUS) imaging in accurately depicting the morphology of atheromatous lesions, ultrasonic tissue characterization has been proposed to determine the composition of atherosclerotic plaques. Elastography is an ultrasound-based imaging technique capable of producing cross-sectional elasticity images called elastograms. The technique involves analysis of echo signals obtained at two states of incremental intravascular pressure. High resolution, local tissue displacement estimation by cross-correlation is followed by computation of local strain. Strain is utilized as an indicator of the local compliance of tissue under the assumption of constant stress within the scan plane. Using vessel-mimicking phantoms, we demonstrate the feasibility of intravascular elastography experimentally. The elastograms are able to depict lesions of different elasticity independently of the echogenicity contrast, since the information provided by the elastograms is generally independent of that obtained from the conventional IVUS image. Thus, the elastogram can complement the characterization of lesions from the conventional IVUS image. Progress to in vitro and in vivo testing is expected in conjunction with ongoing improvements in the current instrumentation and processing.

Angioplasty, Balloon↗

Ultrasonic spectroscopy of the porcine eye lens.

The purpose of the work is to measure and study the acoustic characteristics of the porcine eye lens and find correlations with chemical and optical parameters, obtained from literature. Ultrasonic spectroscopy was performed by using a scanning acoustic macroscope (frequency 20 MHz, resolution 150 microns). The transducer performed a two-dimensional scan over a central slice (1 mm thickness) of porcine lens (number of lenses = 10). A double transmission pulse-echo method was used to acquire the ultrasonic data from the lens. Two-dimensional images were reconstructed of the local ultrasound velocity and the frequency-dependent ultrasound attenuation. Axial and equatorial profiles of these parameters were calculated from the images. The acoustic parameters are not constant, but show a systematic dependence on the location within the lens. The profiles of the acoustic parameters are similar in shape to profiles of the protein and water contents of eye lens and to the profiles of the optical refractive index. A thorough quantitative correlation study is indicated, which should be based on detailed protein content data in porcine lenses.

Animals↗

Acoustic velocity and attenuation of eye tissues at 20 MHz.

The ultrasound velocity and frequency-dependent attenuation of human and porcine eye tissues (cornea, lens, retina, choroid, sclera, vitreous body) were measured in the frequency range from 17 to 23 MHz. The results for the ultrasound velocity were compared to values taken from the literature and appeared to be in the same range. A comparison made between the acoustic parameters of human and porcine eyes showed that the porcine eye can serve as an animal model for the human eye. A mathematical operation is proposed to extrapolate the attenuation to the lower frequencies that are commonly used in clinical equipment. Finally, a first attempt was made to investigate the age dependence of the acoustic parameters of human tissues: some tissues showed a significant age effect.

Acoustics↗