Transatrial implantation of transvenous pacing leads as an alternative to implantation of epicardial leads.

State-of-the-art pacing modalities are not readily utilized with conventional epicardial pacing lead implantation techniques. A transatrial implantation technique was developed combining a limited surgical approach with transvenous leads. Six patients who were poor candidates for transvenous implants have received DDD or DDDR pacemakers by this approach. The limited surgical approach includes resection of the third or fourth costal cartilage through a small skin incision, reflection of the pleura, and opening of the pericardium. The introducer and transvenous leads are inserted through a right atrial pursestring suture. The leads are positioned in the right ventricle and right atrium using standard fluoroscopic techniques. Through the incision, the subcutaneous tissue pocket is constructed on the right anterior chest wall. The leads are connected to the pacemaker without the need for adaptors or tunneling. There were no procedure-related complications. The magnitude of the surgery and postoperative morbidity are significantly less than for a standard thoracotomy, median sternotomy, and transdiaphragmatic epigastric or subcostal approach. The utility of the transatrial implantation technique is that it allows the use of state-of-the- art bipolar dual chamber pacemakers restoring access to all pacing modalities for those patients not candidates for transvenous implantation.

Adult↗

Intravascular lead extraction using locking stylets, sheaths, and other techniques.

UNLABELLED: Septicemia necessitates extraction of chronic pacemaker leads. Using locking stylets and sheaths to extract leads via the implantation vein (subclavian, cephalic, or jugular) and maneuvering devices, sheaths, and retrieval baskets via the femoral approach, extraction of 228 leads implanted 5 days to 240 months (mean 55 months) was attempted in 136 patients (mean 62 years) at 34 institutions. In addition to septicemia (9%) and infection (39%), total 48%, indications included prophylaxis/replacement (40%), and other (12%). Seventy-seven leads were atrial, 151 ventricular; 147 were unipolar, 81 bipolar; 96 had silicone insulation, 127 polyurethane, 1 poly/silicone, and 2 undetermined. Fixation included tines or fins (160), screw (40), flange (12), and other (16). One hundred and ninety-four leads were completely extracted, 19 partly extracted, and 15 not extracted. Procedural complications were: torn atrium requiring open heart repair (1), hemothorax requiring a chest tube and blood transfusions (1), subacute hemothorax requiring drainage 18 days after discharge (1), thrombosis treated by drugs (1), and myocardial avulsion without sequela (1). Important observations included the significant training required due to the large number of possible clinical variables, and the need to be prepared for life-threatening cardiovascular complications. With training, procedures done at higher volume and lower volume institutions met with similar success. CONCLUSION: Intravascular lead extraction is a viable technique whose benefits outweigh the risks, given the proper intensive training and open heart surgical backup, and may obviate the need for open heart surgery for lead extraction.

Adult↗

Intravascular lead extraction using locking stylets and sheaths.

Chronic lead extraction using intravascular countertraction techniques was studied in patients with over 65 different lead models including passive and active fixation devices. Indications for removal of 115 leads implanted 5 days to 264 months (mean 58 months) in 62 patients (mean 65 years) included septicemia, subcutaneous tissue infection, preerosion, free-floating lead, lead trapped in valve, too many leads, pain, and vein thrombosis. The superior vena cava (SVC) approach was attempted in 101 leads and was successful in 82 attempts (71% of total leads). The inferior vena cava (IVC) approach via the femoral vein was required to extract 14 (12%) leads inaccessible to the SVC approach and the 19 leads that failed the SVC approach (29% of total leads). The SVC procedure includes a sized stylet locked at the tip and telescoping sheaths advanced over the lead to the heart. An IVC procedure includes placement of a 16 F sheath workstation via a femoral vein into the right atrium. A deflection catheter and Dotter snare in an 11 F sheath were advanced through the workstation into the right atrium. The lead was maneuvered into position, snared, and pulled into the workstation. For both the SVC and IVC approaches, the leads were removed by applying traction on the lead and countertraction with the sheaths. In experienced hands, these techniques have proven safe and effective for removing chronic transvenous leads.

Adult↗

Atrial capture detection with endocardial electrodes.

A new method of evoked response detection, previously demonstrated in the ventricle, has been studied in the atrium at the time of routine pacemaker implant in 16 patients. The atrial evoked response was readily detectable in all patients due to excellent recovery from poststimulus polarization. In six patients, as experimental threshold-tracking pacemaker was used to automatically verify atrial capture and to generate strength-duration curves. It is concluded that this pacing technique is both simple and reliable, and that automatic atrial threshold tracking is feasible.

Atrial Function↗

DDD pacemakers maximize hemodynamic benefits and minimize complications for most patients.

A 44-month retrospective analysis was performed on 666 pacemakers implanted at Mt. Sinai Medical Center. Mapping techniques and endocardial waveform analyses were used during lead positioning to ensure the best electrical environment. The optimal pacing lead type was selected based on the clinical situation. Follow-up evaluations were rigorous. Patient population ranged in age from 28 to 103 with a mean of 78 years at time of implant. Seventy percent of the patients received DDD pacemakers with an 81% survival incidence at 44 months. Of the VVI population (30% of the implants), there was a 62% survival incidence. Most problems associated with the pacing systems were related to the atrial channel. Loss of atrial sensing occurred in 7.5% of the population and was corrected noninvasively in 5.8%. Due to chronic loss of atrial sensing, 1.7% of the population remained programmed to DVI/VVI. A total of 7.7% were chronically reprogrammed from DDD to VVI, 5.6% secondary to atrial fibrillation. Reoperations were necessary in 1.2% of the malfunctioning systems that could not be corrected by reprogramming. The following conclusions were reached: (1) maximizing hemodynamic benefits and minimizing pacemaker complications permitted a survival rate equal to or better than that of the general population, and (2) chronic problems related to the atrial lead and malfunctions of the pacing system were minimized by careful patient selection, appropriate pacemaker and lead selection, endocardial waveform analysis, and thorough follow-up.

Adult↗

A computerized system for modeling pacemaker rhythms.

We have developed a computer program which simulates a paced cardiac rhythm strip, graphically generating the electrocardiogram (ECG) on a color monitor. Any pacemaker, programmed as desired, dynamically interacts with a preselected intrinsic rhythm. Utilizing symbols prevalent in the pacing industry, this graphics-oriented, interactive system promotes a rapid understanding of pacemaker function by automatically superimposing specific pacemaker events on a rhythm strip. These events include: pacemaker spikes, evoked cardiac depolarization waveforms, refractory periods, upper rate intervals, and blanking periods. Applications of this program include interpreting and verifying appropriate pacemaker function, demonstrating idiosyncrasies of the various pacemakers, and teaching.

Computer Graphics↗

Pacemaker clinic evaluations: key to early identification of surgical problems.

The pacemaker center evaluation was responsible for the timely reoperation of 341 pacemaker patients over the last three years. The most common indication for reoperation was battery end-of-service (46.3%). Battery testing and maintenance of accurate records for trend analysis ensures prompt generator replacement. Atrial and/or ventricular lead malfunction was the second largest indication (26.3%). Lead malfunction detected by bracketing capture and sensing thresholds included: dislodgement, penetration, exit block, fracture, insulation failure, and abnormal sensing. The third largest indication for reoperation was pacemaker pocket erosion and/or infection (15.5%). Examination of the pacemaker pocket site is an integral part of an evaluation. In conclusion, the three largest indications for reoperations can be best demonstrated in a pacemaker center where evaluations are personal and thorough, and accurate record keeping is maintained.

Adult↗

Computer applications to electrophysiologic studies.

The automated studies performed at implant require little extra time and provide essential information for postoperative troubleshooting and patient management. The automated testing and analysis system is but one component in a comprehensive patient management system designed for and dedicated to pacing; the system is an integral part of a complete data management system which includes extensive follow-up and management sections.

Computers↗

Implant experience with unipolar polyurethane pacing leads.

A total of 905 unipolar polyurethane pacing leads have been implanted by the first author's group, between April 1978 and February 1982, with a mean implant of 1.4 years. Twelve leads were explanted and analyzed. Eleven of the explanted leads exhibited some degree of surface damage or "frosting." Of the 11, five atrial (Medtronic 6991 U) and one ventricular (Medtronic 6971) lead suffered complete insulation failure. One lead was completely free from surface damage. Clinically, insulation failure presented as muscle stimulation and/or battery depletion. Surface damage appears to be due to an environmental stress cracking (ESC) mechanism. ESC requires both a surface active agent from the hostile biological environment, and stress in excess of a threshold value. The minor surface damage or "frosting" of the eleven explanted leads was typically 10 to 15 microns deep on leads implanted about one year, although one device (15 months) had 30 micron cracks. No lead failures in this series were attributed to this shallow cracking mechanism. The severe cracking of the six Medtronic leads leading to insulin failure was thought to be due to the unusually high tensile stresses imposed by manufacturing processes and ligatures. The incidence of failure was 7% (5/74) for the Medtronic 6991 U and 0.2% (1/454) for the Medtronic 6971. Medtronic lead manufacturing processes have been modified to reduce the high residual tensile stresses and a fixation sleeve has been added to reduce ligature stress.

Arrhythmias, Cardiac↗

Long-term results of "simple" thrombectomy for thrombosed Björk-Shiley aortic valve prostheses.

During the past two years 8 patients were seen with thrombosis of their Bjork-Shiley aortic valves. Six patients were from our series, an incidence of 4% and 2 patients had their original valve implanted at another institution. All patients had substantial problems with anticoagulation therapy. Three died prior to operation. Early detection and emergency surgical intervention is mandatory for survival. At operation debridement of all thrombotic material from the valve provided satisfactory immediate hemodynamic improvements as well as freedom from complications for up to two years. Therapeutic levels of anticoagulation with warfarin are the only apparent protection from thrombosis of the Bjork-Shiley aortic valve.

Anticoagulants↗

Noninvasive cardiac evaluation (NICE) of intracardiac shunts using inhaled radioactive carbon dioxide.

A totally new, noninvasive technique is presented for the detection and analysis of left-to-right cardiac shunts. Five millicuries of oxygen 15-labeled carbon dioxide is administered by a single-breath inhalation technique. The resultant lung washout curve accurately reflects the presence or absence of a shunt. The quantitative studies are promising, but the method must be compared with standard techniques in a statistically significant series. This work is in progress.

Carbon Dioxide↗

Development of a new technique for explantation of chronic transvenous pacemaker leads: five initial case studies.

Transvenous removal of chronic pacing leads was attempted using a special locking stylet and dilator sheaths. In five initial cases, three of seven leads were infected; six of seven leads were removed. The stylet was inserted into the conductor lumen and locked into the tip to reinforce and control the lead, permitting retraction without stretching the conductor. Sheaths were advanced over the lead to detach and dilate fibrous encapsulation. In one case, force applied exceeded the locking mechanism's strength; no patient complication resulted. It is concluded that transvenous lead removal is facilitated by a locking stylet and dilation of fibrous tissue with sheaths.

Adult↗