C Kappas

Publications and source records attributed to C Kappas.

23 records · Page 2Linked to original sources

A method for measuring the ionization fraction due to the chamber wall (alpha) and assessing its characteristics.

To calibrate a megavoltage therapy beam using an ionization chamber, it is necessary to know the fraction of the ionization arising in the chamber wall when this is made of a material different than the medium. A method for measuring the ionization fraction produced by electrons arising in the chamber wall (alpha) is presented here. The method uses three measurements at the same point in a medium in order to calculate alpha. These measurements are made using the examined chamber with and without a buildup cap and one reference chamber of wall material equivalent to the medium (i.e., in our case, A1 and A-150 were used as wall materials for the examined and the reference chamber, respectively). Using this method, it is possible to calculate alpha in the medium for a series of irradiation conditions and assess its characteristics. Two main conclusions came out of this assessment. The first one is the independence of alpha from the wall material, even if this is aluminum (alpha is only dependent on wall thickness expressed in g cm-2). The second one is that alpha depends on the irradiation conditions; it increases with field size and depth.

Aluminum↗

Quality control of inhomogeneity correction algorithms used in treatment planning systems.

PURPOSE: This quality control program has been carried out under the auspices of S.F.P.H. (Socíete Fraņcaise des Physiciens d'Hôpital), to evaluate the performances of radiotherapy treatment planning systems (RTPS) used by different institutions. The aim of this Quality Assurance Programme was: (a) to set up a methodology to assess globally the capability of a given system to perform inhomogeneity corrections in the irradiated medium with external photon beams; (b) to analyze the limitations of the algorithms presently used and especially the two-dimensional (2D) dose calculation possibilities; (c) to check, on a number of systems in clinical use, the validity of the method and the variation of the results as compared to measurements used as reference. METHODS AND MATERIALS: Phantom (lung equivalent material placed into polystyrene) measurements, using cobalt-60 radiation, were carried out by the authors. The phantoms were circulated among the participating institutes to be scanned, and used as input to the treatment planning computer. RESULTS: Ten systems were tested in this study, using seven different inhomogeneity correction algorithms implemented in nine different TPS; four of these algorithms are used in a pixel by pixel basis and five of them in a contour basis. Significant discrepancies or inconsistencies have been observed even for sophisticated models supposed to be mostly accurate. CONCLUSION: The proposed tests and the experimental data provided are very useful as part of a quality-control program. They should be included in the initial extensive validation of TPS before starting clinical use, and should be repeated at regular intervals and at each updating of the program. They have the merit of including the whole procedure, from patient data acquisition to dose distribution printout.

Algorithms↗

On-axis and off-axis primary dose component in high energy photon beams.

The depth dose of the primary dose component, on axis and off axis of six different x-ray beams, has been determined from transmission measurements in narrow beam geometry with and without flattening filter using a Perspex column of a cross section large enough to ensure electronic equilibrium. In order to derive the primary photon fluence, a correction for the scatter from the column has been applied according to the following method: A number of spectra taken from the literature have been used for computing a scatter coefficient Sc at different depths by convolution of dose spread arrays. Using the relationship between Sc and the single attenuation coefficient mu i to represent each entire spectrum, it has been possible to correct the experimental transmission curves iteratively, until the corresponding values of mu were stabilized and representative of the primary. The measured attenuation coefficients were found to have a linear increase as a function of the distance from the central axis for all the energies and types of linear accelerators. For the same nominal energy, this increase is different from one accelerator to another. The same phenomenon was observed for the attenuation coefficients obtained without the flattening filter in the same experimental conditions. The results are tentatively interpreted considering the angular variation of bremsstrahlung energy spectra with and without a flattening filter as calculated by a Monte Carlo method and they are consistent and useful to take accurately into account the softening of the beam as the off-axis distance increases.

Humans↗

A simple method for the correction of distorted digital angiographic images for stereotactic target localization.

The most commonly used imaging modality for the diagnosis and localization of arteriovenous malformations (AVMs) treated with stereotactic radiotherapy is traditional angiography, but it would be desirable to also use digital subtraction angiography (DSA). However, DSA images are distorted due to the electron-optical characteristics of the X-ray image intensifier. For that reason, we have developed a method for the correction of the image distortion. The ISIS II Treatment Planning System (ISIS II TPS), developed at the Curie Institute, has been used for image acquisition and stereotactic localization. A grid phantom has been constructed for determining the distortion of the DSA images. The software developed for the correction has been implemented into the TPS and is based on a correction vector produced by matching the distorted and corrected grid points. The method has been tested for its ability to correct the position of all grid points as well as its effectiveness in real cases as compared to traditional angiography. The maximum displacement of the corrected grid points compared with their original position is measured to be 0.1 mm. The accuracy of the target localization using the corrected DSA images is comparable with traditional angiography localization and falls inside acceptable accuracy limits. In conclusion, this method offers the possibility of using DSA images for stereotactic localization without limiting the requested accuracy.

Angiography, Digital Subtraction↗

Multimedia educational services in stereotactic radiotherapy.

The computer-based learning methods in medicine have been well established as stand-alone learning systems. Recently, these systems were enriched with the use of telematics technology to provide distance learning capabilities. Stereotactic radiotherapy is one of the most representative advanced radiotherapy techniques. Due to the multidisciplinary character of the technique and the rapid evolution of technology implemented, the demands in training have increased. The potential of interactive multimedia and Internet technologies for the achievement of distance learning capabilities in this domain are investigated. The realization of a computer-based educational program in stereotactic radiotherapy in a multimedia format is a new application in the computer-aided distance learning field. The system is built according to a client and server architecture, based on the Internet infrastructure, and composed of server nodes. The impact of the system may be described in terms of: time and transportation costs saving, flexibility in training (scheduling, rate and subject selection), online communication and interaction with experts, cost effective access to material (delivery or access by a large number of users and revision of the material by avoiding high costs of computer-based training systems and database development).

Computer-Assisted Instruction↗