New developments in intravascular ultrasound imaging.

IntraVascular Ultrasound Imaging (IVUS) has already been proposed in the early days of diagnostic ultrasound. Today, it has come under further full attention as a result of minimal invasive techniques. Not only excellent intravascular two-dimensional (2D) images are presently obtained, also three-dimensional (3D) reconstructed images show their diagnostic value. Based on 3D information, quantitative data such as plaque volume can be calculated. The procedure includes automatic contour detection based on image segmentation methods and greatly speeds up clinical evaluation. With the use of additional X-ray information, the true tortuous vessel geometry can be reconstructed in 3D. This allows, by numerical modelling techniques, to calculate endothelial shear stress values, which in turn may indicate sites prone to stenosis. With a decorrelation technique for radiofrequency (RF) echo information from sequential data in the same beam direction and integration method over the entire cross section, blood velocity can be shown colour-coded during the cardiac cycle, while even blood flow quantification seems to be possible. In vitro as well as in vivo experiments have shown the feasibility of the method. Intravascular imaging can be used to study the biomechanical properties of atheroma components. Local radial strain, used as a measure of local tissue hardness, can be estimated to identify hard or soft plaques independently of the echogenicity contrast between plaque and vessel wall.

Blood Flow Velocity↗

Shear stress in atherosclerosis, and vascular remodelling.

Shear stress plays a role in lipid accumulation in primary atherosclerosis and vascular remodelling. We will present applications of a new technique, which enables to quantify shear stress in 3D vessel reconstructions. The method is based on 3D IVUS reconstructions of blood vessels either obtained by IVUS pull back (external iliac artery) or by a combination of angiography and IVUS (curved coronary artery). Distribution of wall thickness of a curved human right coronary artery was such that low wall thickness occurred where shear stress was high, and wall thickness was high where shear stress was low. Consequently, an inverse relationship between shear stress and wall thickness was detected. Although vascular remodelling after PTA in external iliac arteries of atherosclerotic Yucatan pigs was predicted both by acute gain and decrements in shear stress, the decrement in shear stress appeared a better predictor. In conclusion, shear stress appears to play a role in primary atherosclerosis and vascular remodelling after PTA.

Adaptation, Physiological↗

ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans.

BACKGROUND: Automated systems for the quantitative analysis of three-dimensional (3D) sets of intravascular ultrasound (IVUS) images have been developed to reduce the time required to perform volumetric analyses; however, 3D image reconstruction by these nongated systems is frequently hampered by cyclic artifacts. METHODS AND RESULTS: We used an ECG-gated 3D IVUS image acquisition workstation and a dedicated pullback device in atherosclerotic coronary segments of 30 patients to evaluate (1) the feasibility of this approach of image acquisition, (2) the reproducibility of an automated contour detection algorithm in measuring lumen, external elastic membrane, and plaque+media cross-sectional areas (CSAs) and volumes and the cross-sectional and volumetric plaque+media burden, and (3) the agreement between the automated area measurements and the results of manual tracing. The gated image acquisition took 3.9+/-1.5 minutes. The length of the segments analyzed was 9.6 to 40.0 mm, with 2.3+/-1.5 side branches per segment. The minimum lumen CSA measured 6.4+/-1.7 mm2, and the maximum and average CSA plaque+media burden measured 60.5+/-10.2% and 46.5+/-9.9%, respectively. The automated contour-detection required 34.3+/-7.3 minutes per segment. The differences between these measurements and manual tracing did not exceed 1.6% (SD<6.8%). Intraobserver and interobserver differences in area measurements (n=3421; r=.97 to.99) were <1.6% (SD<7.2%); intraobserver and interobserver differences in volumetric measurements (n=30; r=.99) were <0.4% (SD<3.2%). CONCLUSIONS: ECG-gated acquisition of 3D IVUS image sets is feasible and permits the application of automated contour detection to provide reproducible measurements of the lumen and atherosclerotic plaque CSA and volume in a relatively short analysis time.

Adult↗

Composition of human thrombus assessed by quantitative colorimetric angioscopic analysis.

BACKGROUND: Angioscopy surpasses other diagnostic tools, such as angiography and intravascular ultrasound, in detecting arterial thrombus. This capability arises in part from the unique ability of angioscopy to assess true color during imaging. In practice, hardware-induced chromatic distortions and the subjectivity of human color perception substantially limit the theoretic potential of angioscopic color. We used a novel application of tristimulus colorimetry to quantify thrombus color to both aid in its detection and assess its composition. METHODS AND RESULTS: A series of human thrombus models were constructed in vitro. Spatial homogeneity was ensured by light and electron microscopy. Quantitative colorimetric angioscopic analysis demonstrated excellent measurement reproducibility (mean difference, 0.07% to 0.17%), unaffected by illuminating light intensity (coefficient of variation, 0.21% to 3.67%). Colorimetric parameters C1 and C2 were strongly correlated (r=.99, P<.0001) with thrombus erythrocyte concentration. Principal components analysis transformed these parameters into a single value, the thrombus erythrocyte index, with little (0.06%) loss of content. Measured and predicted concentrations were similar (mean difference, 0.16 erythrocytes per 1 ng). Randomly ordered images were also subjected to visual analysis by three experienced angioscopists, with suboptimal levels of both intraobserver (mean kappa=0.63) and interobserver (mean kappa=0.48) agreement. In addition, visual ranking resulted in a Kendall rank coefficient of 0.72 to 0.76 versus a perfect 1.00 from quantitative measurement. CONCLUSIONS: Quantitative colorimetric angioscopic analysis provides a new, objective, and reproducible analytic tool for assessing angioscopic images of human thrombus. Even under ideal circumstances, experienced angioscopists do a poor job of assessing color (and therefore composition) of human thrombi. This technique can, for the first time, provide quantitative information of thrombus composition during routine diagnostic imaging.

Angioscopy↗

Cardiac depression after experimental air embolism in pigs: role of addition of a surface-active agent.

OBJECTIVE: Air bubbles entering the coronary artery may have harmful effects on cardiac function. From the physical point of view it is the relatively high surface tension of the blood-air interface which causes bubbles to trap in small vessels. The aim of the present study was to reduce depression of myocardial function from air embolism by lowering the surface tension of air bubbles. METHODS: The effect of using antifoam as a surface-tension-reducing agent on air bubble entrapment and cardiac function was investigated in 6 anesthetized pigs (27 +/- 1 kg) and analyzed using a two-compartment diffusion model. Air bubbles with a diameter of 150 microns were selectively injected into the left anterior descending coronary artery (LADCA) in a carrying fluid in the presence or absence of antifoam. Myocardial systolic segment shortening in the LADCA region (SS-LADCA) was measured by sonomicrometry. Presence of emboli was detected by measuring the amount of reverberation of ultrasound scattered by trapped air bubbles. RESULTS: SS-LADCA transiently decreased after injections of air bubbles in both the absence and presence of antifoam. However, in the presence of antifoam the regional depression recovered to normal sooner, the average depth of the depression was reduced, and bubbles from the embolized area cleared faster. These observations can be explained by a model derived from Laplace's law.

Animals↗

Evaluation of endothelial shear stress and 3D geometry as factors determining the development of atherosclerosis and remodeling in human coronary arteries in vivo. Combining 3D reconstruction from angiography and IVUS (ANGUS) with computational fluid dynamics.

The predilection sites of atherosclerotic plaques implicate rheologic factors like shear stress underlying the genesis of atherosclerosis. Presently no technique is available that enables one to provide 3D shear stress data in human coronary arteries in vivo. In this study, we describe a novel technique that uses a recently developed 3D reconstruction technique to calculate shear stress on the endothelium with computational fluid dynamics. In addition, we calculated local wall thickness, the principal plane of curvature, and the location of plaque with reference to this plane, relating these results to shear stress in a human right coronary artery in vivo. Wall thickness and shear stress values for the entire vessel for three inflow-velocity values (10 cm/second, 20 cm/second, and 30 cm/second equivalents with the Reynolds numbers 114,229, and 457) were as follows: 0.65 +/- 0.37 mm (n = 1600) and 19.6 +/- 1.7 dyne/cm2; 46.1 +/- 8.1 dyne/cm2 and 80.1 +/- 16.8 dyne/cm2 (n = 1600). Curvature was 25 +/- 9 (m-1), resulting in Dean numbers 20 +/- 8; 46 +/- 16, and 93 +/- 33. Selection of data at the inner curvature of the right coronary artery provided wall thickness values of 0.90 +/- 0.41 mm (n = 100), and shear stress was 17 +/- 17, 38 +/- 44, and 77 +/- 54 dyne/cm2 (n = 100), whereas wall thickness values at the outer curve were 0.37 +/- 0.17 mm (n = 100) and shear stress values were 22 +/- 17, 60 +/- 44, and 107 +/- 79 dyne/cm2 (n = 100). These findings could be reconciled by an inverse relationship between wall thickness and shear stress for each velocity level under study. For the first time for human vessels in vivo, evidence is presented that low shear stress promotes atherosclerosis. As the method is nondestructive, it allows repeated measurements in the same patient and will provide new insights in the progress of atherosclerosis.

Coronary Angiography↗

True reconstruction of vessel geometry from combined X-ray angiographic and intracoronary ultrasound data.

At present a rapidly expanding variety of methods appear to provide three-dimensional (3-D) reconstructions of blood vessels in a patient. Generally the results of such methods look very realistic. However, only a few produce a true 3-D reconstruction. We strongly suggest that for a true 3-D reconstruction of a blood vessel the following criteria should at least be fulfilled: (1) the arterial wall rather than the lumen must be reconstructed; (2) the spatially curved course of the vessel must be included; and (3) the orientation of local vessel wall characteristics, for example, plaque eccentricity, with respect to the luminal course must be correctly maintained. Currently, only methods combining biplane X-ray angiography and intravascular ultrasound imaging (IVUS) have succeeded in providing true 3-D reconstruction of a segment of a vessel. Accuracy of those reconstructions is derived from studies using phantoms having precisely known geometry. In patients, data on accuracy are more difficult to obtain. Nevertheless, a comparison can be made between the actual length of an IVUS pull-back trajectory and its reconstructed length showing relative differences of less than 3%. Further knowledge can be obtained by comparing simulated angiograms derived from the 3-D reconstruction with the real contrast angiograms. True 3-D reconstruction methods of the vessel wall and lumen, applicable in the individual patient, have become feasible and produce accurate results. Application of such a method will be helpful to understand immediate and long-term vessel remodelling induced by all types of catheter interventions and in the study of progression or regression of atherosclerotic wall disease.

Coronary Angiography↗

Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were -0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraob-server and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (-0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.

Algorithms↗

Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach.

BACKGROUND: Computerized quantitative coronary angiography (QCA) has fundamentally altered our approach to the assessment of coronary interventional techniques and strategies aimed at the prevention of recurrence and progression of stenosis. It is essential, therefore, that the performance of QCA systems, upon which much of our scientific understanding has become integrally dependent, is evaluated in an objective and uniform manner. METHODS AND RESULTS: We validated 10 QCA systems at core laboratories in North America and Europe. Cine films were made of phantom stenoses of known diameter (0.5 to 1.9 mm) under four experimental conditions: in vivo (coronary arteries of pigs) calibrated at the isocenter or by use of the catheter as a scaling device and in vitro with 50% contrast and 100% contrast. The cine films were analyzed by each automated QCA system without observer interaction. Accuracy and precision were taken as the mean and SD of the signed differences between the phantom stenoses, and the measured minimal luminal diameters and the correlation coefficient (r), the SEE, the y intercept, and the slope were derived by their linear regression. Performance of the 10 QCA systems ranged widely: accuracy, +0.07 to +0.31 mm; precision, +/- 0.14 to +/- 0.24 mm; correlation (r), .96 to .89; SEE, +/- 0.11 to +/- 0.16 mm; intercept, +0.08 to +0.31 mm; and slope, 0.86 to 0.64. CONCLUSIONS: There is a marked variability in performance between systems when assessed over the range of 0.5 to 1.9 mm. The range of accuracy, intercept, and slope values of this report indicates that absolute measurements of luminal diameter from different multicenter angiographic trials may not be directly comparable and additionally suggests that such absolute measurements may not be directly applicable to clinical practice using an on-line QCA system with a different edge detection algorithm. Power calculations and study design of angiographic trials should be adjusted for the precision of the QCA system used to avoid the risk of failing to detect small differences in patient populations. This study may guide the fine-tuning of algorithms incorporated within each system and facilitate the maintenance of high standards of QCA for scientific studies.

Algorithms↗

Three-dimensional reconstruction of coronary arteries with intravascular ultrasound.

Three-dimensional (3D-) reconstruction of intravascular ultrasound (IVUS) images is a recently introduced technical method which has rapidly grown in science and clinical practice. In the catheterization laboratory it is particularly important to obtain the 3D-reconstruction on-line, since the dimensions measured and the plaque attributes displayed may guide the therapeutic decision. Off-line reconstruction, however, provides very accurate and reproducible area and volume measurements of lumen and plaque and is thus exceptionally qualified for studying progression/regression of atherosclerosis or restenosis after catheter-based interventions. Complementary 3D-reconstruction methods, revealing specific advantages and limitations, meet the requirements by slightly different technical approaches, but each 3D-reconstruction of two-dimensional IVUS images requires some basic procedural steps. The IVUS images can be acquired during continuous or ECG-gated withdrawals of the IVUS imaging catheter. The latter permits even to visualize the cyclic pulsation of the reconstructed arteries. As an alternative approach a sensing device recognizes the insertion depth of the IVUS catheter and permits reliable measurements even during manual handling of the IVUS catheter. A discrimination between the blood-pool and structures of the vascular wall, performed in the digitized images, can be achieved by the application of different techniques. This processing step which is called segmentation and the image acquisition are particularly crucial with regards to the final quality of the 3D-reconstruction. Currently there are still limitations of 3D-IVUS, but a new approach combining data obtained from 3D-IVUS and biplane angiography offers a promising potential to solve most of the remaining problems in the future. Thus, three-dimensional IVUS offers a great clinical and scientific potential since it provides spatial visualization of vascular pathology, longitudinal and volumetric measurement of luminal and plaque dimensions, and facilitated guidance of catheter-based interventions. Assuming a technical development similar to the progress of the previous years. 3D-IVUS has a realistic chance to gain significant importance and to become a routine technique in the future.

Computer Graphics↗

Color quantification in angioscopic video images.

Colors in video representations of angioscopic images are up until now described by an human observer. Differences in settings of the monitor and the inherent poor ability of the human eye to classify colors objectively results in a very poor intraobserver as well as interobserver variability. A PC-based method is described to measure colors in a video image and to present the results in a novel C-diagram. Results with this method for standard calibrated colors are given. Possible sources of error are discussed and methods to minimize these errors are presented.

Algorithms↗

Volumetric intracoronary ultrasound: a new maximum confidence approach for the quantitative assessment of progression-regression of atherosclerosis?

Quantitative assessment of atherosclerosis during its natural history and following therapeutic interventions is important, as cardiovascular disease remains the most significant cause of morbidity and mortality in industrial societies. While coronary angiography delineates the vessel lumen, permitting only the indirect determination of atherosclerotic wall changes encroaching upon the lumen, intracoronary ultrasound permits direct plaque assessment and quantification. The angiographic percent diameter stenosis, previously suggested as measure of a maximum confidence approach, is still commonly used to quantify stenosis severity, but the reference segments which are required for angiographic interpolation of the normal vessel dimensions are frequently involved in the general process of atherosclerosis, including progression or regression. Considering also the variability of vascular remodeling during the evolution of atherosclerosis, including compensatory enlargement and paradoxical arterial shrinkage, intracoronary ultrasound appears currently to be the only reliable technique to measure plaque burden and progression or regression of atherosclerosis. However, correct matching of the site of measurement at follow-up with the site of the initial ultrasound study is often difficult to achieve, but is significantly facilitated by the use of volumetric intracoronary ultrasound. This approach permits not only area measurement, but also measurement of plaque volume, which appears to be the ideal measure for quantifying the atherosclerotic plaque, as it is highly reproducible and directly reflects the changes of an entire arterial segment.

Animals↗

Luminal volume reconstruction from angioscopic video images of casts from human coronary arteries.

Intravascular angioscopy has been hampered by its limitation in quantifying obtained images. To circumvent this problem, a lightwire was used, which projects a ring of light onto the endoluminal wall in front of the angioscope. This investigation was designed to quantify luminal dimensions of casts from stenotic human coronary arteries and to investigate the feasibility of performing volume reconstruction. Angioscopic video recordings were made during simultaneous motorized pullback (2 mm/s) of an angioscopic catheter and light-emitting fiber through 4 epoxy casts from human coronary arteries. Quantification of the images was performed using a computerized cross-sectional area measurement system. The coronary casts were divided into cross-sectional segments of 4 to 10 mm in thickness, with the true volume of each segment determined by means of a microdispenser. Because of vessel curvature and luminal narrowing, complete visualization of the ring of light at all 1-mm-distant locations was only possible in 19 of 40 segments. For these 19 segments, linear regression analysis showed a good correlation between measured and true segmental volume (r = 0.97, y = 0.88x + 6.58 mm3, standard error of estimate = 3.48 mm3). The relative error in the measured segmental volumes was 3.9 +/- 7.1% (mean +/- SD). These initial results of endoluminal volume reconstruction demonstrate the feasibility of this technique in vitro with high accuracy and low variability, but further technical improvements are necessary to increase the success rate, especially in the quantitative assessment of vessels with complex morphology.

Angioscopes↗

Quantification of intracoronary volume by videodensitometry: validation study using fluid filling of human coronary casts.

Changes in intracoronary volume reflect the hemodynamic significance of progression or regression of diffuse coronary artery disease where intracoronary catheters cannot be applied for direct measurements due to small vessel dimensions. We have validated the videodensitometric measurement of intracoronary volume with epoxy casts of postmortem human coronary arteries. The volume of 31 coronary segments (cross-sectional areas in a range of 2-13 mm2) measured by fluid-filling using a precision dispenser was compared with the respective single plane intracoronary volume assessments obtained by the videodensitometric algorithm of the new generation Cardiovascular Angiography Analysis System (CAAS II). The true and measured values of volume were compared by calculation of the mean of the signed differences +/- standard deviation and by linear regression analysis. Videodensitometric measurement of intracoronary volume correlate well with fluid-filling of human coronary artery casts (correlation coefficient: r = 0.99, y = 1.96 +/- 0.99x, standard error of estimate: SEE = 3.96) with a significant trend towards overestimation of true volume values (mean difference = 1.73 +/- 3.64 mm3, P < 0.05). Intracoronary volume estimations can be used to measure changes of luminal dimensions of coronary arteries and may offer a new approach to assessment of progression or regression of diffuse coronary artery disease.

Coronary Angiography↗

Spark erosion myectomy in hypertrophic obstructive cardiomyopathy.

The design features of the cutting electrode and the electrical characteristics of a monopolar electrosurgical device were specially adapted for performing a septal myectomy in patients with hypertrophic obstructive cardiomyopathy. Both the cutting behavior and electrode design were found to facilitate myectomy.

Adult↗

Loss of elastic recoil in postischemic myocardium induces rightward shift of the systolic pressure-volume relationship.

Ischemia-induced systolic dysfunction has been ascribed to changes in cellular excitation-contraction coupling and diastolic dysfunction because of disruption of the extracellular collagen matrix. Therefore, systolic and diastolic pressure-volume relationships and O2 consumption were determined before and after 5 min of global ischemia in isolated blood-perfused porcine hearts. The slope of the systolic pressure-volume relationship was 7.2 +/- 0.6 (SE) mmHg.ml-1.100 g-1 (n = 18) at baseline and did not change during reperfusion, but the systolic volume intercept shifted from 1.0 +/- 0.4 ml/100 g at baseline to 3.7 +/- 1.4, 4.1 +/- 1.1, and 4.2 +/- 0.9 ml/100 g at 15, 30, and 60 min of reperfusion, respectively (all P < 0.05). The diastolic volume intercept was 8.2 +/- 0.7 ml/100 g at baseline and remained unchanged during reperfusion. Therefore, the difference of the systolic-diastolic volume intercepts, an index of elastic recoil forces, was decreased to 57 +/- 8, 49 +/- 7, and 47 +/- 9% of baseline values (P < 0.05). The shift of the systolic pressure-volume relationship was accompanied by a transient decrease of contractile efficiency (slope of O2 consumption-pressure-volume-area relationship) at 15 min of reperfusion (from 43 +/- 6 to 27 +/- 7%). We hypothesize that the rightward shift of the systolic pressure-volume relationship was compatible with a decrease of elastic-restoring forces, probably induced by alterations in the extracellular collagen matrix and/or the cytoskeleton, and thereby our data imply that left ventricular dysfunction of postischemic myocardium does not result solely from disturbances in excitation-contraction coupling.

Animals↗

Effect of arterial blood pressure and ventilation gases on cardiac depression induced by coronary air embolism.

In this study the time course of cardiac depression after selective intracoronary injection of air bubbles was investigated in six anesthetized pigs (30 +/- 2 kg) with different mixtures of ventilation gases and different mean arterial blood pressures (MAP). Air bubbles of 150 microns diam were injected into the left anterior descending coronary artery (LADCA) in a volume of 2 microliters/kg body wt. In each animal an injection of air bubbles was applied during ventilation with N2-O2 and a MAP of 77 +/- 3 mmHg (N2-O2/low pressure) or 111 +/- 3 mmHg (N2-O2/high pressure) and during ventilation with pure O2 and a MAP of 77 +/- 3 mmHg (O2/low pressure) or 110 +/- 3 mmHg (O2/high pressure). Systemic hemodynamic variables such as left ventricular pressure, its peak first derivatives, and MAP changed < 10% after injection of air bubbles. During N2-O2/low pressure, systolic segment length shortening in the LADCA region (SS-LADCA) decreased from baseline and did not return to baseline within the 10 min after injection of air bubbles. During N2-O2/high pressure and O2/low pressure, SS-LADCA was decreased between 60 and 120 s, whereas for O2/high pressure this period was from 60 to 90 s. By calculating the time integral of the deviation from baseline of SS-LADCA, it could be demonstrated that the depression of regional myocardial function was less severe during O2/high pressure and O2/low pressure than during N2-O2/low pressure. We conclude that, when coronary air embolism occurs during hypertension and during ventilation with pure O2 instead of a normal N2-O2 mixture, the resulting depression of regional myocardial function is reduced.

Animals↗

Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions.

Although intracoronary ultrasonography allows detailed tomographic imaging of the arterial wall, it fails to provide data on the structural architecture and longitudinal extent of arterial disease. This information is essential for decision making during therapeutic interventions. Three-dimensional reconstruction techniques offer visualization of the complex longitudinal architecture of atherosclerotic plaques in composite display. Progress in computer hardware and software technology have shortened the reconstruction process and reduced operator interaction considerably, generating three-dimensional images with delineation of mural anatomy and pathology. The indications for intravascular ultrasonography will grow as the technique offers the unique capability of providing ultrasonic histology of the arterial wall, and the need for a three-dimensional display format for comprehensive analysis is increasingly recognized. Consequently, three-dimensional imaging is being rapidly implemented in the catheterization laboratories for guidance of intracoronary interventions and detailed assessment of their results. However exciting the prospects may be, three-dimensional reconstructions at present remain partially artificial because the true spatial position of the imaging catheter tip is not recorded, and shifts in its location and curves of the arterial lumen result in pseudoreconstructions rather than true reconstructions. In this report, we address the principles of three-dimensional reconstruction with a critical review of its limitations. Potential solutions for refinement of this exciting imaging modality are presented.

Algorithms↗