Search PubMed⌕ Search

Biomedical subjects

C J Müller

Publications and source records attributed to C J Müller.

3 recordsLinked to original sources

Strontium binding by calcium silicate hydrates.

In the present study the binding of strontium with pure calcium silicate hydrates (C-S-H) has been investigated using batch-type experiments. Synthetic C-S-H phases with varying CaO:SiO(2) (C:S) mol ratios, relevant to non-degraded and degraded hardened cement paste, were prepared in the absence of alkalis (Na(I), K(I)) and in an alkali-rich artificial cement pore water (ACW). Two types of experimental approaches have been employed, investigating sorption and co-precipitation processes, respectively. The Sr(II) sorption kinetics were determined as well as sorption isotherms, the effect of the solid to liquid ratio and the composition (C:S ratio) of the C-S-H phases. In addition, the reversibility of the Sr(II) sorption was tested. It was shown that both the sorption and co-precipitation tests resulted in Sr(II) distribution ratios which were similar in value, indicating that the same sites are involved in Sr(II) binding. In alkali-free solutions, the Sr(II) uptake by C-S-H phases was described in terms of a Sr(2+)-Ca(2+) ion exchange model. The selectivity coefficient for the Sr(2+)-Ca(2+) exchange was determined to be 1.2+/-0.3.

Calcium Compounds↗

MR lung imaging at 0.2 T with T1-weighted true FISP: native and oxygen-enhanced.

An inversion recovery true fast imaging with steady precession (FISP) pulse sequence was developed to carry out fast imaging of the lungs at 0.2 T. Using this sequence, oxygen-enhanced magnetic resonance (MR) lung imaging was performed on healthy volunteers. The lungs showed signal enhancement (11.7% +/- 3.8%) when breathing 100% oxygen. Using inversion recovery, true FISP at low field may prove promising for MR lung imaging.

Artifacts↗

Optimization and evaluation of the signal intensity change in multisection oxygen-enhanced MR lung imaging.

The behavior of the signal intensity in MRI of human lungs was investigated during inhalation of pure oxygen. Nine volunteers were examined, five using a breath-hold and four using a non-breath-hold technique. Four coronal slices were acquired in each volunteer using an inversion recovery turbo spin-echo sequence. The inversion time of the sequence was optimized for maximum contrast. Breathing of pure oxygen and room air was alternated in the volunteers. Breath-hold and non-breath-hold cases were compared. Breathing pure oxygen lead to a statistically significant signal intensity increase (up to 18%) compared to breathing room air. In addition, T(1) maps were acquired during breathing 100% oxygen and room air. Inhalation of pure oxygen reduced the mean T(1) time of the lungs from 1280 (+/-85) msec to 1224 (+/-139) msec without breath-hold and from 1219 (+/-176) to 1074 (+/-92) msec with breath-hold. Therefore, an optimized sequence and measurement protocol provided significant signal intensity changes utilizing 100% oxygen. Magn Reson Med 43:860-866, 2000.

Adult↗