Advanced pulse oximeter signal processing technology compared to simple averaging. I. Effect on frequency of alarms in the operating room.

STUDY OBJECTIVE: To determine the effect of a new signal processing technique (Oxismart, Nellcor, Inc., Pleasanton, CA) on the incidence of false pulse oximeter alarms in the operating room (OR). DESIGN: Prospective observational study. SETTING: Nonuniversity hospital. PATIENTS: 53 ASA physical status I, II, and III consecutive patients undergoing general anesthesia with tracheal intubation. MEASUREMENTS AND MAIN RESULTS: In the OR we compared the number of alarms produced by a recently developed third generation pulse oximeter (Nellcor Symphony N-3000) with Oxismart signal processing technique and a conventional pulse oximeter (Criticare 504). Three pulse oximeters were used simultaneously in each patient: a Nellcor pulse oximeter, a Criticare with the signal averaging time set at 3 seconds (Criticareaverage3s) and a similar unit with the signal averaging time set at 21 seconds (Criticareaverage21s). For each pulse oximeter, the number of false (artifact) alarms was counted. One false alarm was produced by the Nellcor (duration 55 sec) and one false alarm by the Criticareaverage21s monitor (5 sec). The incidence of false alarms was higher in Criticareaverage3s. In eight patients, Criticareaverage3s produced 20 false alarms (p < 0.01). CONCLUSIONS: Our study did not show a beneficial effect in the OR on the incidence of false alarms of the Nellcor monitor with Oxismart signal processing compared with the Criticare monitor with the longer averaging time of 21 seconds.

Adolescent↗

The influence of nitrous oxide to supplement fentanyl/low-dose propofol anesthesia on transcranial myogenic motor-evoked potentials during thoracic aortic surgery.

OBJECTIVE: Intraoperative monitoring of myogenic motor evoked potentials to transcranial electrical stimulation (tc MEPs) is a new method to assess the integrity of the motor pathways. The authors studied the effects of 50% nitrous oxide (N2O) and a low-dose propofol infusion on tc MEPs paired electrical stimulation during fentanyl anesthesia with partial neuromuscular blockade. DESIGN: Cross-over study. SETTING: St Antonius Hospital, Nieuwegein, The Netherlands. PARTICIPANTS: Ten patients scheduled to undergo surgery on the thoracoabdominal aorta were studied; 6 women aged 54 to 69 years and 4 men aged 68 to 77 years. INTERVENTIONS: After achieving a stable anesthetic state and before surgery, tc MEPs were recorded during four 15-minute periods: (I) air/oxygen (O2; F(I)O2 = 50%); propofol target blood concentration, 0.5 microg/mL; (II) N2O/O2 (F(I)O2 = 50%); propofol target blood concentration, 0.5 microg/mL; (III) N2O/O2 (F(I)O2 = 50%; propofol target blood concentration, 1.0 microg/mL; and (IV) air/O2 (F(I)O2 = 50%); propofol target blood concentration, 1.0 microg/mL. MEASUREMENTS AND MAIN RESULTS: Tc MEPs were recorded from the right extensor digitorum communis muscle and the right tibialis anterior muscle. The right thenar muscle was used for recording the level of relaxation; the T1 response was maintained at 40% to 70% of the control compound muscle action potential. There was no significant difference in onset latency among the four phases. The addition of N2O and doubling the target propofol infusion to 1.0 microg/mL resulted in a 40% to 50% reduction of tc MEP amplitude recorded in the extensor digitorum communis muscle and tibialis anterior muscle (p < 0.01). During each phase, tc MEPs could be elicited and interpreted, except in one patient, in whom no tc MEPs could be elicited in the leg because of technical problems. CONCLUSION: The data indicate that tc MEP monitoring is feasible during low-dose propofol, fentanyl/50% N2O in 02 anesthesia and partial neuromuscular blockade.

Action Potentials↗

A comparison of myogenic motor evoked responses to electrical and magnetic transcranial stimulation during nitrous oxide/opioid anesthesia.

UNLABELLED: Transcranial motor evoked potentials (tc-MEPs) are used to monitor spinal cord integrity intraoperatively. We compared myogenic motor evoked responses with electrical and magnetic transcranial stimuli during nitrous oxide/opioid anesthesia. In 11 patients undergoing spinal surgery, anesthesia was induced with i.v. etomidate 0.3 mg/kg and sufentanil 1.5 microg/kg and was maintained with sufentanil 0.5 microg x kg(-1) x h(-1) and N2O 50% in oxygen. Muscle relaxation was kept at 25% of control with i.v. vecuronium. Electrical stimulation was accomplished with a transcranial stimulator set at maximal output (1200 V). Magnetic transcranial stimulation was accomplished with a transcranial stimulator set at maximal output (2 T). Just before skin incision, triplicate responses to single stimuli with both modes of cortical stimulation were randomly recorded from the tibialis anterior muscles. Amplitudes and latencies were compared using the Wilcoxon signed rank test. Bilateral tc-MEP responses were obtained in every patient with electrical stimulation. Magnetic stimulation evoked only unilateral responses in two patients. With electrical stimulation, the median tc-MEP amplitude was 401 microV (range 145-1145 microV), and latency was 32.8 +/- 2.3 ms. With magnetic stimulation, the tc-MEP amplitude was 287 microV (range 64-506 microV) (P < 0.05), and the latency was 34.7 +/- 2.1 ms (P < 0.05). We conclude that myogenic responses to magnetic transcranial stimulation are more sensitive to anesthetic-induced motoneural depression compared with those elicited by electrical transcranial stimulation. IMPLICATIONS: Transcranial motor evoked potentials are used to monitor spinal cord integrity intraoperatively. We compared the relative efficacy of electrical and magnetic transcranial stimuli in anesthetized patients. It seems that myogenic responses to magnetic transcranial stimulation are more sensitive to anesthetic-induced motoneural depression compared with electrical transcranial stimulation.

Anesthesia, General↗

Middle latency auditory evoked responses and electroencephalographic derived variables do not predict movement to noxious stimulation during 1 minimum alveolar anesthetic concentration isoflurane/nitrous oxide anesthesia.

UNLABELLED: The electroencephalogram (EEG) and middle latency auditory evoked responses (MLAER) have been proposed for assessment of the depth of anesthesia. However, a reliable monitor of the adequacy of anesthesia has not yet been defined. In a multicenter study, we tested whether changes in the EEG and MLAER after a tetanic stimulus applied to the wrist could be used to predict subsequent movement in response to skin incision in patients anesthetized with 1 minimum alveolar anesthetic concentration (MAC) isoflurane in N2O. We also investigated whether the absolute values of any of these variables before skin incision was able to predict subsequent movement. After the induction of anesthesia with propofol and facilitation of tracheal intubation with succinylcholine, 82 patients received 1 MAC isoflurane (0.6%) in N2O 50% without an opioid or muscle relaxant. Spontaneous EEG and MLAER to auditory click-stimulation were recorded from a single frontoparietal electrode pair. MLAER were severely depressed at 1 MAC isoflurane. At least 20 min before skin incision, a 5-s tetanic stimulus was applied at the wrist, and the changes in EEG and MLAER were recorded. EEG and MLAER values were evaluated before and after skin incision for patients who did not move in response to tetanic stimulation. Twenty patients (24%) moved after tetanic stimulation. The changes in the EEG or MLAER variables were unable to predict which patients would move in response to skin incision. Preincision values were not different between patients who did and did not move in response to skin incision for any of the variables. MLAER amplitude increased after skin incision. We conclude that it is unlikely that linear EEG measures or MLAER variables can be of practical use in titrating isoflurane anesthesia to prevent movement in response to noxious stimulation. IMPLICATIONS: Reliable estimation of anesthetic adequacy remains a challenge. Changes in spontaneous or auditory evoked brain activity after a brief electrical stimulus at the wrist could not be used to predict whether anesthetized patients would subsequently move at the time of surgical incision.

Adolescent↗

Comparison of transcranial motor evoked potentials and somatosensory evoked potentials during thoracoabdominal aortic aneurysm repair.

OBJECTIVE: To compare transcranial motor evoked potentials (tc-MEPs) and somatosensory evoked potentials (SSEPs) as indicators of spinal cord function during thoracoabdominal aortic aneurysm repair. SUMMARY BACKGROUND DATA: Somatosensory evoked potentials reflect conduction in dorsal columns. tc-MEPs represent anterior horn motor neuron function. This is the first study to compare the techniques directly during thoracoabdominal aortic aneurysm repair. METHODS: In 38 patients, thoracoabdominal aortic aneurysm repair (type I, n = 10, type II, n = 14, type III, n = 6, type IV, n = 8) was performed using left heart bypass and segmental artery reimplantation. tc-MEP amplitudes <25% and SSEP amplitudes <50% and/or latencies >110% were considered indicators of cord ischemia. The authors compared the response of both methods to interventions and correlated the responses at the end of surgery to neurologic outcomes. RESULTS: Ischemic tc-MEP changes occurred in 18/38 patients and could be restored by segmental artery reperfusion (n = 12) or by increasing blood pressure (n = 6). Significant SSEP changes accompanied these tc-MEP events in only 5/18 patients, with a delay of 2 to 34 minutes. SSEPs recovered in only two patients. In another 11 patients, SSEP amplitudes fell progressively to <50% of control without parallel tc-MEP changes or association with cross-clamp events or pressure decreases. At the end of the procedure, tc-MEP amplitudes were 84 +/- 46% of control. In contrast, SSEP amplitudes were <50% of control in 15 patients (39%). No paraplegia occurred. CONCLUSION: In all patients, tc-MEP events could be corrected by applying protective strategies. No patient awoke paraplegic. SSEPs showed delayed ischemia detection and a high rate of false-positive results.

Adult↗

Reduced renal failure following thoracoabdominal aortic aneurysm repair by selective perfusion.

OBJECTIVES: Renal failure and visceral ischemia are feared complications following thoracoabdominal aortic aneurysm (TAAA) repair, significantly contributing to mortality. This prospective study describes volume- and pressure-controlled perfusion of the renal and visceral arteries during TAAA surgery. METHODS: In 73 consecutive patients (mean age 59 years), TAAA repair (27 type I, 28 type II, 8 type III and 10 type IV) was performed, using retrograde and selective organ perfusion. Sixteen patients had impaired renal function with blood creatinine higher than 100 mmol/l. During the thoracic part of the procedure, the mean distal aortic pressure was kept above 60 mm Hg by means of left-heart bypass. After opening the abdominal aorta, the renal and visceral arteries were individually perfused by means of perfusion catheters (9 French) in the first 33 patients (group I). Volume flow through each catheter was assessed with ultrasound flow meters and maintained at least at 60 ml/min. In addition to volume flow measurements, catheters with pressure sensors were used in the last 40 patients (group II), allowing pressure-controlled selective perfusion. The extent of the aneurysm was comparable in both groups. RESULTS: Mean cross-clamp time for the thoracic part was 46 min, including proximal anastomosis and reattachment of intercostal arteries. Mean cross-clamp time for the abdominal part was 74 min, including re-implantation of intestinal and renal arteries and selective dacron grafts to the celiac-axis arteries (n = 5), superior mesenteric arteries (n = 8) and renal arteries (n = 25), through which the catheters guaranteed continuous perfusion during the time the anastomosis was performed. Urine output was uninterrupted in all patients, irrespective of cross-clamp time. In group I, one patient (3%) developed renal failure and three patients (9%) required temporary peritoneal dialysis. In group II, no patients developed renal failure and two patients (5%) required temporary peritoneal dialysis. Thirteen patients with pre-existing renal impairment did not deteriorate. No patients developed visceral ischemia or multiple-organ failure. Total in-hospital mortality was 6/73 (8%) and was related to cardiopulmonary complications. CONCLUSIONS: Renal and visceral ischemia can be reduced significantly by continuous perfusion during cross-clamping in TAAA repair. Not only sufficient volume flow but also adequate arterial pressure appears to be essential in maintaining renal function.

Aortic Aneurysm, Abdominal↗

Spinal cord monitoring with myogenic motor evoked potentials: early detection of spinal cord ischemia as an integral part of spinal cord protective strategies during thoracoabdominal aneurysm surgery.

Spinal cord ischemia during resection of thoracoabdominal aortic aneurysms (TAA) can result in lower limb neurological deficits. Spinal cord monitoring can only improve outcome if ischemia is detected before irreversible damage has occurred and protective measures are readily available. Monitorin( spinal cord function with motor evoked potentials (MEPs) is a relatively new technique. With MEP. recorded from the muscle (myogenic MEPs), the vulnerable spinal motoneuronal system is exclusively monitored and ischemia is detected within minutes. Using a strategy aimed at maintaining and restoring spinal cord blood supply (distal aortic perfusion, sequential aortic clamping, and selective segmental artery reattachment), early detection of ischemia allows protective measures to be applied and adjusted immediately, ie, reattaching or safely ligating intercostal arteries, increasing proximal o distal aortic pressures as required, or inducing hypothermia. Recent improvements in the technique fo eliciting myogenic MEPs include multi-pulse stimulation paradigms and the use of a circumferentia cathode. This results in robust and reproducible signals, which are less susceptible to anesthetic interference and allow the use of a constant level of neuromuscular blockade. In conclusion, monitoring myogenic MEPs during a TAA repair has become clinically feasible. The fast detection of spinal cord ischemia allows timely guidance of protective measures.

Animals↗

Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.

OBJECTIVE: The potential benefit of a reduced frequency of false pulse oximeter low oxyhemoglobin saturation (SpO2) alarms is that the attention of personnel is only directed to patients who experience hypoxemia. The present study was undertaken to better understand the effects of different settings of the pulse oximeter on false (artifact) and true (hypoxemia) alarms. METHODS: Using the original SpO2 data of 200 postoperative patients, we calculated off-line the effects of five methods (artifact rejection, alarm delay (2-44 s, 2 s increments), averaging (10-90 s), median filtering (10-90 s) and decreasing the alarm limit from 90% to 85%) on the number of (true- and false) alarms. RESULTS: 830 episodes of hypoxemia (SpO2 < or = 90%) and 73 episodes of severe hypoxemia (SpO2 < or = 85%) occurred. With a SpO2 alarm limit of 90%, the alarm was triggered 1535 times (830 true, 705 false). Artifact rejection reduced alarms by almost 50%. An alarm delay of 6 s or an averaging or median filtering epoch of 10 s resulted in an alarm reduction of almost 50%. No differences were found in the reduction of alarms between averaging and median filtering. Changing the alarm limit to 85% reduced the number of alarms by 82%. A similar reduction of alarms was obtained with either an alarm delay of 18 s or an averaging or median filtering epoch of 42 s. However, an alarm limit of 85% reduced the number of false alarms less than the other three algorithms (p < 0.01). CONCLUSIONS: The data from the present study suggest that in order to effectively suppress false alarms caused by pulse oximeter artifacts, it may be preferable to use a longer filtering epoch of approximately 40 s, rather than to decrease the lower alarm limit.

Artifacts↗

Cardiovascular responses, arterial oxygen saturation and plasma catecholamine concentration during upper gastrointestinal endoscopy using conscious sedation with midazolam or propofol.

Hypoventilation as a consequence of deep intravenous sedation is the most frequently reported cause of cardiac arrest during upper gastrointestinal endoscopy (UGIE). Haemodynamic stress can contribute to myocardial ischaemia; therefore, this study was designed to observe prospectively the cardiorespiratory changes during UGIE using either midazolam or propofol for conscious sedation. Thirty-four patients, aged 50 years and older, ASA physical status I-III, scheduled for elective UGIE with sedation, were studied. Oxygen saturation, heart rate, non-invasive blood pressure and Holter ECG were recorded continuously starting 15 min before sedation until 15 min after the endoscopy. In addition, plasma catecholamine concentrations were determined. The results of this study are consistent with previous reports that cardiopulmonary events may occur during endoscopy, with or without sedation. Both midazolam and propofol sedation may provide some protection against haemodynamic stress in response to insertion and manipulation of the endoscope, but sedation can also contribute to the occurrence of hypoxaemia.

Aged↗

Pharmacokinetics of propofol during conscious sedation using target-controlled infusion in anxious patients undergoing dental treatment.

Infusion of propofol by a target-controlled infusion (TCI) system is effective in achieving conscious sedation for anxious patients presenting for dental surgery. It is a common clinical observation that anxious patients require more anaesthetic drugs than non-anxious individuals. In study 1 we have defined blood propofol concentrations necessary for conscious sedation in both anxious (n = 23) and non-anxious (n = 18) patients. The pump performance of the TCI system, using Gepts' pharmacokinetic model, was evaluated in these two patient groups. Subsequently, clearance of propofol was compared in the two groups. Mean measured venous serum propofol concentrations obtained between 20 and 35 min after the optimal sedation level was reached were 1.6 (SD 0.2) micrograms ml-1 in the anxious patients compared with 1.7 (0.3) micrograms ml-1 in the control group (study 1) and 1.4 (0.27) micrograms ml-1 in study 2. The pump systematically overpredicted measured propofol concentrations in both groups (study 1). There was no significant difference in propofol clearance between the two groups. In study 2, an optimized set of microconstants was derived which should more accurately predict the pharmacokinetic profile of the anxious population and this set was tested prospectively in another group of 12 anxious dental patients. Bias and precision with the optimized kinetic set were significantly less than the values obtained in study 1. We conclude that there was no significant pharmacokinetic differences between anxious and non-anxious subjects receiving subanaesthetic doses of propofol for conscious sedation.

Adolescent↗

Quantitative electroencephalographic analysis of the biphasic concentration-effect relationship of propofol in surgical patients during extradural analgesia.

We studied effects on the EEG of propofol infused at a rate of 0.5 mg kg-1 min-1 for 10 min in 10 healthy male surgical patients under extradural analgesia. The EEG amplitude in six frequency bands was related to arterial blood propofol concentrations and responsiveness to verbal commands. The EEG amplitude showed a characteristic biphasic response to increasing blood propofol concentrations in all frequency bands. During the infusion, patients lost responsiveness when EEG amplitudes in the high frequency bands were decreasing after having reached a maximum. EEG changes were different during infusion and emergence. Pharmacodynamic modelling, using two effect compartments with dissimilar equilibration constants, resulted in satisfactory fits. We conclude that propofol exerts a biphasic effect on the EEG amplitude in all frequency bands. The dissimilarity of EEG changes during infusion and during emergence suggests that two effect compartments with different equilibration constants exert opposing effects on the EEG.

Adult↗

Patient-controlled versus anesthesiologist-controlled conscious sedation with propofol for dental treatment in anxious patients.

UNLABELLED: In a randomized, cross-over study, we prospectively compared the efficacy and quality of two methods to achieve conscious sedation with propofol in 11 unpremedicated, anxious dental patients. Each patient underwent two dental procedures, one that was conducted under target-controlled infusion (TCI) by the anesthesiologist (ACS), and the other that used patient-controlled sedation (PCS). The initial target concentration in the ACS mode was 2.5 microg/mL, which was manipulated in both directions until the desired clinical end point was achieved. In the PCS mode, a 4-mg bolus of propofol (10 mg/mL) was delivered at each activation of the machine, infused over 7 s without a lockout interval. The anxious dental patients could induce and maintain conscious sedation with the PCS settings. The mean (range) venous blood propofol concentrations were not significantly different with either mode: ACS 1.8 (0.8-2.7) microg/mL and PCS 1.2 (0.2-2.5) microg/mL. The level of patient satisfaction, quality of sedation, and treatability were not different for either mode of sedation. The intensity of amnesia for intraoperative events was related to the blood concentrations achieved. In the ACS mode, one patient became unresponsive (sedation level 4) immediately after the start of sedation. No adverse cardiorespiratory effects resulted from either mode of propofol sedation. Five patients expressed a strong preference for PCS, and three would prefer ACS in the future. The results of the present study suggest that with these PCS settings, a satisfactory level of conscious sedation and a high level of patient satisfaction was achieved. IMPLICATIONS: In a randomized, cross-over study, the blood propofol concentrations necessary to achieve conscious sedation in anxious dental patients using a target-controlled infusion conducted by the anesthesiologist versus patient-controlled sedation were not different. With the patient-controlled sedation settings, a satisfactory level of conscious sedation and a high level of patient satisfaction were achieved.

Adult↗

Influence of isoflurane on myogenic motor evoked potentials to single and multiple transcranial stimuli during nitrous oxide/opioid anesthesia.

OBJECTIVE: Transcranial motor evoked potentials (tc-MEPs) are used to monitor the spinal cord intraoperatively. Volatile anesthetics considerably depress amplitudes of tc-MEPs. This study was undertaken to determine whether multipulse stimulation might overcome this depressant effect. METHODS: In 10 patients undergoing spinal surgery, incremental doses of isoflurane were added to a nitrous oxide/opioid anesthetic regimen and maintained constant at 0.2, 0.4, and 0.6% end tidal for at least 15 minutes. tc-MEP responses to single-pulse and trains of three and five (interstimulus interval, 2 ms) transcranial electrical stimuli were recorded from the tibialis anterior muscles. RESULTS: Before the addition of isoflurane, tc-MEPs were recordable in all patients, even with single-pulse stimuli (median amplitude, 428 microV). With 0.2% end-tidal isoflurane, tc-MEPs were recordable in eight patients with single-pulse stimulation and in all patients with three and five successive stimuli. At 0.4% isoflurane, responses were recordable in only one patient using single-pulse stimuli and in all patients using three and five stimuli. With 0.6% isoflurane, tc-MEPs to trains of three and five stimuli were recordable in all patients except one. The amplitude of the responses obtained with 0.2, 0.4, and 0.6% end-tidal isoflurane was significantly smaller than that of control responses (P < 0.05). CONCLUSION: These data suggest that despite the powerful depressant effects of isoflurane on myogenic motor responses, tc-MEP monitoring during isoflurane anesthesia may be feasible, provided that multipulse stimulation paradigms are used and the concentration of isoflurane does not exceed 1 minimal anesthetic concentration unit.

Adolescent↗

Effect of mild hypothermia and the 21-aminosteroid U-74389G on neurologic and histopathologic outcome after transient spinal cord ischemia in the rabbit.

Mild hypothermia and the 21-aminosteroids have both been neuroprotective in several models of cerebral ischemia. In this study we compared the effects of mild hypothermia and the 21-aminosteroid U-74389G, alone and in combination on neurologic and histopathologic outcome after temporary spinal cord ischemia. Forty male anesthetized New Zealand white rabbits were randomized to four groups (n = 10): (a) normothermia (control); (b) U-74389G (3 mg/kg intravenously [i.v.] before aortic occlusion, 1.5 mg/kg i.v. and 10 mg/kg intraperitoneally after occlusion); (c) mild hypothermia (4 degrees C epidural temperature decrease); and (d) mild hypothermia combined with U-74389G. Spinal cord ischemia was produced by 40 min of infrarenal aortic balloon occlusion. Forty-eight hours after the procedure, the neurologic status of the animals was assessed (Tarlov score) and the animals were killed for histologic evaluation. In the normothermic control group, eight of 10 animals became paraplegic. There was a significant reduction of the incidence of paraplegia and overall neurologic deficits and a significant improved Tarlov score in the mild hypothermic group (one animal paraplegic) and in the group with both mild hypothermia and U-74389G (two animals with a mild paraparesis). The histopathologic scores showed significantly less damage in both hypothermic groups. In group 2, U-74389G administration did not improve neurologic or histopathologic outcomes. The results of the current study demonstrate that a slight decrease of intraischemic spinal cord temperature significantly improved neurologic and histopathologic outcomes after experimental spinal cord ischemia. Protection by the 21-aminosteroid at normothermic conditions, or additional protection when U-74389G was added to mild hypothermia, could not be demonstrated.

Anesthesia, Intravenous↗

Computer controlled infusion of propofol for conscious sedation in dental treatment.

OBJECTIVE: To assess a drug delivery system that can rapidly achieve and maintain a constant blood concentration of Propofol (2,6 di-isopropyl phenol) which, in subanaesthetic doses, is an effective intravenous sedative for treating anxious or handicapped patients in dentistry. DESIGN: The clinical use of a computer controlled infusion system to induce and maintain conscious sedation with propofol was prospectively studied. Based on a 3-compartment pharmacokinetic model, the system calculates the initial bolus dose and infusion rates to achieve a user-selected target blood concentration. SETTING: Amsterdam Center for Special Dental Care. SUBJECTS: 89 patients attending for dental treatment. RESULTS: Treatment could be performed within 2 minutes after the onset of the infusion. The median therapeutic target blood propofol concentration was 2.5 micrograms/ml and the median recovery time was 9 minutes. Transient oversedation (38 procedures) could easily be treated by decreasing the target concentration. No adverse cardiorespiratory effects resulted from propofol sedation. Venous blood propofol concentrations were measured in 25 anxious patients. The kinetic data set used in this study underestimated the distribution and elimination of propofol in our patients. CONCLUSIONS: Computer controlled infusion of propofol can provide satisfactory and safe conscious sedation in dental patients.

Adolescent↗

Efficacy of transcranial motor-evoked myogenic potentials to detect spinal cord ischemia during operations for thoracoabdominal aneurysms.

OBJECTIVE: Motor-evoked myogenic potentials after transcranial electrical stimulation monitor the vulnerable motoneuronal system of the spinal cord. This study reports our initial experiences with motor-evoked potentials to assess the adequacy of spinal cord perfusion during operations for thoracoabdominal aneurysms. METHODS: In 20 patients undergoing thoracoabdominal aneurysm operations, myogenic motor-evoked potentials were recorded. In 18 patients retrograde aortic perfusion was used. When spinal cord ischemia was detected, distal flow or mean arterial pressure was increased in an attempt to restore cord perfusion. By means of sequential crossclamping, motor-evoked potentials were also used to identify intercostal or lumbar arteries that needed to be reimplanted. RESULTS: Reproducible motor-evoked potentials could be recorded in all patients. During retrograde perfusion, nine patients showed a rapid decrease in the amplitude of motor-evoked potentials to less than 25% of baseline, indicating spinal cord ischemia. In five patients ischemic changes in motor-evoked potentials could be reversed by increasing distal and proximal blood pressures. In four patients ischemic changes during crossclamping necessitated segmental artery reimplantation. In three of these four patients intercostal or lumbar arteries were reattached. In one patient reimplantation of segmental arteries was not possible; this patient awoke paraplegic. Segmental arteries were ligated after confirmation of intact motor-evoked potentials during aortic clamping in eight patients. None of these patients had a neurologic deficit. The absence of motor-evoked potentials at the end of the procedure always indicated a postoperative motor deficit. CONCLUSION: During operations for thoracoabdominal aneurysms, monitoring of motor-evoked potentials is an effective technique to detect spinal cord ischemia within minutes. This modality can be used to guide the management of distal aortic perfusion techniques and may also help to identify segmental arteries that need to be reattached.

Adult↗

Retrograde aortic and selective organ perfusion during thoracoabdominal aortic aneurysm repair.

OBJECTIVES: To evaluate the possible prevention of renal and intestinal ischaemia during surgery of thoracoabdominal aortic aneurysms (TAAA) by use of retrograde and selective organ perfusion. DESIGN: Prospective study. MATERIALS: Thirty-three consecutive patients underwent TAAA repair, six of whom had a previous type B dissection: 14 patients (35%) had type I TAAA, 12 patients type II (32%), three patients type III (15%) and four patients type IV (18%). Mean age was 61 years (range 22-84 years). METHODS: In patients with type I TAAA, retrograde aortic perfusion was performed by means of a left atrium femoral artery bypass or partial cardiopulmonary bypass. In type II, III and IV the same procedure was performed; however, following cross-clamping and opening of the abdominal aorta, the coeliac trunc, superior mesenteric and both renal arteries were selectively perfused with four Pruitt-catheters (9 Fr.), connected as an octopus to the extracorporal circulation. RESULTS: All patients survived the surgical procedure. The minimal volume flow through each octopus catheter was 60 ml/min. Urine output was uninterrupted in all patients, irrespective of the aortic cross-clamp time. Only one patient (3%), who already had renal insufficiency, developed renal failure. Total in-hospital mortality was 15%, paraplegia occurred in 12%. CONCLUSION: Retrograde aortic and selective organ perfusion is a safe technique and can prevent ischaemic renal and intestinal damage during cross-clamping of the aorta in thoracoabdominal aneurysm surgery.

Adult↗