A nomogram to classify men with lower urinary tract symptoms using urine flow and noninvasive measurement of bladder pressure.

PURPOSE: Bladder pressure during voiding can be estimated by a noninvasive technique using controlled inflation of a penile cuff. This test provides a valid and reliable estimate of isovolumetric bladder pressure but to our knowledge the role of the test for the routine clinical treatment of patients with lower urinary tract symptoms (LUTS) has yet to be demonstrated. As a first step, we evaluated a proposed nomogram for the diagnosis of bladder outlet obstruction in men with LUTS using noninvasive measurements of pressure and flow. MATERIALS AND METHODS: Using a combination of theoretical calculation and experimental data the existing International Continence Society pressure flow nomogram was modified to allow noninvasive measurement of isovolumetric bladder pressure in place of detrusor pressure at maximum urine flow. Accuracy of the nomogram for classifying obstruction was then tested in a group of 144 men with LUTS who underwent an invasive and a noninvasive pressure flow study. RESULTS: The modified nomogram identified men with obstruction with 68% positive predictive value and 78% negative predictive value. Predictive accuracy could be improved by adding an additional criterion of obstruction, that is maximum urine flow less than 10 ml second, whereby an identifiable 69% of all cases could be classified as obstructed (88% positive predictive value) or not obstructed (86% negative predictive value). In the remaining 31% of patients invasive pressure flow studies would provide additional information, although some results would remain equivocal. CONCLUSIONS: The proposed nomogram combined with the additional flow rate criterion can classify more than two-thirds of cases without recourse to invasive pressure flow studies. We must now evaluate the usefulness of this classification for the treatment of men with LUTS.

Aged↗

An automated penile compression release maneuver as a noninvasive test for diagnosis of bladder outlet obstruction.

PURPOSE: We tested the hypothesis that the previously described penile urethral compression release (PCR) maneuver provides a valid diagnosis of bladder outlet obstruction (BOO) using automated rather than manual penile compression by controlled inflation of a penile cuff. We also investigated urodynamic events underlying generation of the PCR index. MATERIALS AND METHODS: A total of 150 subjects attending for pressure flow studies were studied using conventional and noninvasive cystometry. Patients were classified into urodynamic diagnostic groups using standard invasive studies. The PCR index was calculated for each individual from noninvasive penile cuff data and the results were summarized for each group. ROC analysis of the PCR index was performed to define an optimum threshold for BOO diagnosis. Simultaneous invasive and noninvasive data were used to define the relationship between the PCR index, bladder contractility and the maximum flow rate. RESULTS: The mean PCR index +/- SD was significantly higher in the BOO group compared to the normal cystometry group (215% +/- 84% vs 93% +/- 39, p <0.01). ROC analysis showed that a PCR index of greater than 160% diagnosed BOO with 78% sensitivity, 84% specificity and a positive predictive value of 69%. There was a strong positive correlation between the PCR index and isovolumetric detrusor pressure, which is a measure of bladder contractility (r = 0.44, p <0.01). CONCLUSIONS: The results of this study suggest that the PCR index combines valid estimates of bladder contractility and the maximum flow rate, and it represents a clinically useful, noninvasive urodynamic parameter for the diagnosis of BOO.

Adult↗

Noninvasive measurement of bladder pressure. Does mechanical interruption of the urinary stream inhibit detrusor contraction?

PURPOSE: As part of developing a noninvasive method to measure bladder pressure using an inflatable penile cuff, we tested the hypothesis that detrusor contraction is maintained without inhibition during the test. MATERIALS AND METHODS: Five healthy volunteers and 26 male patients with lower urinary tract symptoms underwent interruption of established urine flow by controlled inflation of a cuff placed around the penis with simultaneous invasive bladder pressure monitoring. After interruption of flow the cuff was rapidly deflated and voiding was allowed to resume. The bladder pressure was recorded before, during and after interruption of flow by cuff inflation. RESULTS: During flow interruption an isovolumetric increase in detrusor pressure was observed. When the cuff was deflated the detrusor pressure quickly returned to preinflation values and urine flow immediately resumed. Intra-abdominal pressure did not change during the cuff inflation cycle. CONCLUSIONS: Mechanical interruption of urine flow by controlled inflation of a penile cuff during voiding does not inhibit detrusor contraction. This finding further validates our noninvasive technique of bladder pressure measurement and supports ongoing studies into its clinical usefulness.

Adolescent↗

Screening for tuberculosis: the port of arrival scheme compared with screening in general practice and the homeless.

BACKGROUND: Tuberculosis is increasing in London, especially in those recently entering the UK from an area of high incidence. Screening through the port of arrival scheme has a poor yield and has been considered discriminatory. METHODS: A study was undertaken to compare the yield and costs of screening new entrants in a hospital based new entrants' clinic (1262 referrals from the port of arrival), general practice (1311 new registrations), and centres for the homeless (267 individuals) using a symptom questionnaire and tuberculin testing if indicated. Clinical outcome measures were cases of tuberculosis, tuberculin reactors requiring chemoprophylaxis and BCG vaccinations. Cost outcomes were cost per individual screened and cost per individual per case of tuberculosis prevented. RESULTS: Verbal screening limited tuberculin testing to 16% of those in general practice; most were tested at the other two locations. Intervention (BCG vaccination, chemoprophylaxis or treatment) occurred in 27% of those who received tuberculin testing. Attendance for screening was 17% of the port of arrival notifications (63% had registered with a GP), 54% in primary care, and 67% in the homeless (42% registered with a GP). Costs for screening an individual in general practice, hostels for the homeless, and the new entrants' clinic were 1.26 pounds sterling, 13.17 pounds sterling and 96.36 pounds sterling, respectively, while the cost per person screened per case of tuberculosis prevented was 6.32 pounds sterling, 23.00 pounds sterling, and 10.00 pounds sterling, respectively. The benefit of screening was highly sensitive to the number of cases of tuberculosis identified and case holding during treatment. CONCLUSION: Screening for tuberculosis in primary care is feasible and could replace hospital screening of new arrivals for those registered with a GP.

Adolescent↗

Noninvasive measurement of bladder pressure by controlled inflation of a penile cuff.

PURPOSE: A noninvasive test providing reliable objective quantification of bladder pressure during the voiding cycle would make an important contribution to the management of lower urinary tract symptoms. We developed a new noninvasive test to measure bladder pressure in males based on controlled inflation of a penile cuff during voiding. We compared the new technique with simultaneous invasive bladder pressure measurement. MATERIALS AND METHODS: We evaluated 7 volunteers and 32 patients. A conventional pressure flow study was performed first. The bladder was refilled, a penile cuff was fitted and after voiding commenced the cuff was inflated in steps of 10 cm. water every 0.75 seconds until urine flow was interrupted. The cuff was rapidly deflated, allowing flow to resume, and the cycle was repeated until the end of voiding. The flow rate was graphed against cuff pressure for each interruption cycle to determine the pressure at which flow was interrupted. This pressure was compared with simultaneous invasive isovolumetric bladder pressure. RESULTS: Invasive and noninvasive pressure measurements agreed well. Average cuff pressure at interruption of flow exceeded mean simultaneous isovolumetric bladder pressure plus or minus standard deviation by 14.5 +/- 14.0 cm. water. CONCLUSIONS: The new method provides noninvasive quantitative information on voiding bladder pressure in males. Further study is required to assess whether the technique can contribute to the management of lower urinary tract symptoms.

Adult↗

The effect of posture on Quantec measurements.

The effect of moving the patient's centre of gravity from one extreme to the other, where the weight is entirely supported on the left or right foot at either extreme, was investigated in 33 patients attending for surface topography measurements with the Quantec Spinal Measurement System. Average changes of about 20 were seen in the measured curvature of the lower spine line and pelvic tilt, but there was considerable variation between individual patients. When such extremes of stance were included, the reproducibility of measurements of the curvature of the lower spine, pelvic tilt and vertical alignment was poorer, but not to the extent that a significant improvement in reproducibility would be expected if the patient's centre of gravity was closely controlled with, for example, a force platform.

Analysis of Variance↗

Monitoring the thoracic sagittal curvature in kyphoscoliosis with surface topography: a trend analysis of 57 patients.

Records of Quantec measurements of tlie kypliotic curvature of the back were reviewed for all patients attending the children's orthopaedic clinic who were referred for back shape measurements. Of these, 57 children had five or more preoperative visits allowing trends to be calculated. Linear trends were found in 30 of the patients, with gradients ranging from 1.1 degree/yr to 7.2(0)1/yr. On average, the scatter of measurements about the trend line, or about the mean value in the other 27 cases, compared well with that expected from repeatability studies but the amount of scatter varied from one patient to another. This may well be due to sampling. Where such measurements are monitored for evidence of change in an individual patient, the possibility of larger than average scatter about any emerging trend should be considered.

Analysis of Variance↗

Transmission of penile cuff pressure to the penile urethra.

PURPOSE: We developed a noninvasive method to measure voiding bladder pressure by inflating a penile cuff to interrupt flow. We tested the underlying assumption that cuff pressure is transmitted to the penile urethra. MATERIALS AND METHODS: In 35 men we simultaneously recorded penile cuff and urethral pressure during 2 experimental protocols for 6 cuffs of various widths and manufactures. Initially a urethral pressure transducer was placed at the mid point of the cuff and urethral pressure was continuously recorded during cuff inflation. In experiment 2 cuff pressure was set at 120 cm. water and the urethral pressure profile was measured by withdrawing the urethral transducer through the cuff width. RESULTS: There was excellent agreement of cuff with urethral pressure over the range of 0 to 200 cm. water for cuffs 37 to 54 mm. wide. Narrower cuffs showed wider variation with less efficient transmission of cuff pressure to the urethral lumen. Similarly maximum pressure in the urethral pressure profile showed best agreement for cuffs 38 and 46 mm. wide. Wider cuffs produced higher and narrower cuffs produced lower transmitted pressure within the urethra. Cuff performance was also related to penile size. Results had good within-subject repeatability. CONCLUSIONS: We demonstrated that pressure transmission from cuff to urethra is optimal at a cuff width of 40 to 50 mm. and recommended this width for other investigations of noninvasive bladder pressure measurement.

Equipment Design↗

Objective benefit of laser palatoplasty for non-apnoeic snoring.

Laser palatoplasty (LPP) is widely used for the treatment of non-apnoeic snoring, despite the lack of objective data supporting its use. We report measurements of snoring in a prospective study of LPP, and we compare the results with a previous study of uvulopalatopharyngoplasty (UPPP). Twenty patients with an apnoea/hypopnoea index < 20 h-1 underwent LPP for habitual snoring. Overnight sound recordings were compared before and 6 months after operation using three objective indices; L, (the level exceeded by the loudest 1% of sound), L5 (the level exceeded by the loudest 5% of sound) and P50 (% total sleep time above 50 dBA). The subjective impression of snoring severity (Wilcoxon test, P < 0.001), and objective indices L1 and P50 (t-test, P < 0.001) showed significant reductions after LPP. The mean change in L1 was 4.2 dBA, comparable to that we previously reported for UPPP, while P50 was reduced to less than one-third its preoperative value. No other sleep variables changed significantly following LPP. We conclude that LPP results in reduced snoring volume comparable to that following UPPP.

Acoustics↗

Psychometric performance before and after laser palatoplasty for non-apnoeic snoring.

Psychometric tests are an objective way of examining cognitive functioning, and have shown impairment in patients with obstructive sleep apnoea. Non-apnoeic snoring may cause reduced concentration, but psychometric tests have been used rarely in this population. We investigate whether their use can demonstrate an improvement in cognitive performance in 20 non-apnoeic snorers following Laser Palatoplasty (LPP). The subjects completed psychometric tests, Beck Anxiety and Depression Inventories and an Epworth Sleepiness Scale on two occasions before LPP and once postoperatively. The only index to show any significant change with LPP was the Beck Depression Inventory (P < 0.005), which was reduced by a mean of 1.6 units following surgery. There was also a highly significant improvement in information processing between the preoperative tests, for which no explanation could be found. Our results suggest that commonly applied psychometric tests are unable to demonstrate significant improvements following surgery for non-apnoeic snoring. However, we have demonstrated for the first time a significant reduction in depression following surgery, which is evidence that snoring is more than a social nuisance.

Cognition↗

Can postal prompts from general practitioners improve the uptake of breast screening? A randomised controlled trial in one east London general practice.

OBJECTIVE: To determine the effect on the uptake of breast screening of a personalized letter from the general practitioner recommending mammography, sent to coincide with an invitation from the NHS breast screening programme. DESIGN: Randomised control trial with stratification of prognostic variables. SETTING: A group practice in Hackney, east London. SUBJECTS: 473 women invited for breast screening by the City and East London Breast Screening Service. OUTCOME MEASURE: Attendance for mammography. RESULTS: All women in the randomised trial were followed up; 134 of 236 (57%) randomly allocated to receive the prompting letter attended for mammography compared with 120 of 234 (51%) controls This difference was not significant (chi 2 = 1.43, p = 0.23) CONCLUSION: Personal recommendation by a letter prompting attendance for mammography from the general practitioner known best to women due to be screened did not improve uptake of breast screening in this east London practice. Other strategies are needed to increase uptake of mammography in inner cities.

Family Practice↗

Interobserver variability in recognizing arousal in respiratory sleep disorders.

Daytime sleepiness is a common consequence of repeated arousal in obstructive sleep apnea (OSA). Arousal indices are sometimes used to make decisions on treatment, but there is no evidence that arousals are detected similarly even by experienced observers. Using the American Sleep Disorders Association (ASDA) definition of arousal in terms of the accompanying electroencephalogram (EEG) changes, we have quantified interobserver agreement for arousal scoring and identified factors affecting it. Ten patients with suspected OSA were studied; three representative EEG events during each of light, slow-wave, and rapid-eye-movement (REM) sleep were extracted from each record (90 events total) and evaluated by experts in 14 sleep laboratories. Observers differed (ANOVA, p < 0.001) in the number of events scored as arousal (totals ranged from 23 to 53 of the 90 events). Overall agreement was moderate (kappa = 0.47), but it was best for events during slow-wave sleep, moderate for REM, and poor for light sleep (kappa = 0.60, 0.52, and 0.28, respectively). Agreement was unrelated to arousal duration. We conclude that the ASDA definition of arousal is only moderately repeatable. Account should be taken of this variability when results from different centers are compared.

Adult↗

Evaluation of activity-based techniques to identify transient arousal in respiratory sleep disorders.

Daytime sleepiness and impaired cognitive function can be a consequence of recurrent transient arousal from sleep. Arousal is often associated with abrupt changes in the electroencephalogram (EEG), and such changes can be used as an index of sleep disturbance, but EEG analysis is laborious and requires trained observers. Possible alternative indices of arousal not reliant on EEG analysis were investigated. Recordings were made from 36 sleeping subjects who were being investigated for sleep-related breathing disorders. In each study awakenings and transient arousals according to EEG criteria were compared with activity in five potential indirect indicators of arousal: wrist movement, ankle movement, left and right tibial electromyogram, and phase change in ribcage-abdominal movement. The mean values of sensitivity to arousal ranged from only 25 to 45%. However, their high positive predictive accuracies (PPAs, 68 to 92%) indicated that activity, when present, was usually associated with arousal. Sensitivity to awakenings was higher (71-87%), though PPAs were lower (42 to 63%). For the indicator based on ribcage-abdominal phase, the number of periods of activity showed a significant relation to the number of arousals (r = 0.70, P < 0.001). It can be concluded that phase changes in chest/abdomen movement are a useful indicator of arousal associated with obstructive apnoea and related conditions. Limb activity has much lower sensitivity for transient arousal, but may be of value in indicating periods of wakefulness.

Adult↗

Automated recognition of EEG changes accompanying arousal in respiratory sleep disorders.

Daytime sleepiness and impaired cognitive function can be a consequence of recurrent transient arousal from sleep, associated with abrupt changes in the electroencephalogram (EEG). EEG is normally assessed by trained observers from paper records, but automation offers the advantages of speed and objectivity. We assessed 10 automated indices of EEG activity as potential indicators of arousal. Arousals from light, slow wave and rapid eye movement sleep were studied in 30 subjects. Segments of EEG recorded immediately before and after each arousal were analyzed by automated measurement of 10 EEG indices using a personal computer. We investigated the ability of each index to recognize arousal while rejecting change due to variability during sleep. Nine of the 10 indices showed significant changes with arousal (p < 0.001); the better indices were related to EEG frequency, and 3 were chosen for further study. In these indices, the mean changes with arousal were 3.8 Hz (ZeroCross), 1.7 Hz (Hjorth's Mobility) and 1.2 Hz (FrqMean, an index of central EEG frequency). With none of these three indices were significant differences in performance due to base sleep stage or subject group found. We conclude that detection of arousal is feasible using automated methods that measure simple indices related to the frequency of the EEG waveform.

Adult↗

Comparison of methods for assessing snoring.

Objective measurements of several sound level indices were made on 32 subjects referred because of snoring and who subsequently underwent uvulopalatopharyngoplasty (UPPP). The measurements were repeated approximately 6 months post-UPPP. The indices were compared with the subjective assessment of snoring by both the subject and his/her bed partner. Correlations between objective and subjective assessments were generally weak and were strongest when the supine posture only was considered. The index which correlated best with subjective assessment was the level which 1% of the sound level samples exceeded.

Abdomen↗

Objective measurement of the results of uvulopalatopharyngoplasty.

Thirty-two patients undergoing uvulopalatopharyngoplasty (UPPP) for snoring have been studied prospectively using objective measurement of snoring levels. A significant reduction was found, especially in the supine posture. The quantitative reduction was small and correlations between subjective and objective changes in snoring volume were weak.

Adult↗

Respiratory muscle activity during rapid eye movement (REM) sleep in patients with chronic obstructive pulmonary disease.

BACKGROUND: In patients with chronic obstructive pulmonary disease (COPD) periods of hypopnoea occur during rapid eye movement (REM) sleep, but the mechanisms involved are not clear. METHODS: Ten patients with stable COPD were studied during nocturnal sleep. Detailed measurements were made of surface electromyographic (EMG) activity of several respiratory muscle groups and the accompanying chest wall motion using magnetometers. RESULTS: Hypopnoea occurred in association with eye movements during phasic rapid eye movement (pREM) sleep. During pREM sleep there were reductions in EMG activity of the intercostal, diaphragm, and upper airway muscles compared with non-REM sleep. Episodic hypopnoea due to partial upper airway occlusion ("obstructive" hypopnoea) was seen consistently in four subjects while the others showed the pattern of "central" hypopnoea accompanied by an overall reduction in inspiratory muscle activity. Although activity of the intercostal muscles was reduced relatively more than that of the diaphragm, lateral rib cage paradox (Hoover's sign) was less obvious during pREM-related hypopnoea than during wakefulness or non-REM sleep. CONCLUSIONS: Hypopnoea during REM sleep in patients with COPD is associated with reduced inspiratory muscle activity. The pattern of hypopnoea may be either "obstructive" or "central" and is generally consistent within an individual. Relatively unopposed action of the diaphragm on the rib cage during REM sleep is not accompanied by greater lateral inspiratory paradox.

Aged↗