Search PubMed⌕ Search

Biomedical subjects

C J Davidson

Publications and source records attributed to C J Davidson.

At least 55 records · Page 3Linked to original sources

Vocational rehabilitation services in workers' compensation programs: evaluating research model effectiveness.

Vocational rehabilitation programs are a strategy used by many, employers to manage workers' compensation costs and the consequence of injuries for their workers. Soaring costs for employers and public entities associated with workers' compensation programs and vocational rehabilitation services indicate that additional research is needed--a need further demonstrated by the serious financial, social and psychological costs that workplace disability exacts from workers.

Accidents, Occupational↗

Aortic valve replacement in adults after balloon aortic valvuloplasty.

BACKGROUND: Percutaneous balloon aortic valvuloplasty is limited by a high risk of procedural morbidity, transient clinical benefit, and a high restenosis rate. The management of patients with symptomatic aortic valve restenosis after percutaneous balloon aortic valvuloplasty is unclear. We hypothesized that aortic valve replacement would produce superior midterm survival compared with repeat balloon aortic valvuloplasty or medication alone in patients with symptomatic aortic valve restenosis after prior balloon aortic valvuloplasty. METHODS AND RESULTS: Baseline clinical, echocardiographic, and hemodynamic data were collected on 165 patients who underwent percutaneous balloon aortic valvuloplasty as treatment for symptomatic degenerative calcific aortic stenosis. In 144 of these patients (87%), aortic valve replacement was originally considered to carry excessive risk. The survival of three subgroups was calculated during a median follow-up period of 3.9 years (range, 1 to 6 years). Ninety-four patients (57%) had no further mechanical intervention (subgroup 1-BAV), 31 patients (19%) developed symptomatic aortic valve restenosis and underwent a repeat balloon aortic valvuloplasty (subgroup 2-BAV), and 40 patients (24%) subsequently underwent aortic valve replacement (subgroup BAV+AVR). Follow-up was 99% complete. Patients in subgroup BAV+AVR tended to be younger and have a lower prevalence of coronary artery disease or mitral regurgitation. Only 1 patient (2.5%) suffered a perioperative death during aortic valve replacement. The probability of survival 3 years from the date of the last mechanical intervention was 13% for subgroup 1-BAV, 20% for subgroup 2-BAV, and 75% for subgroup BAV+AVR. At the conclusion of follow-up, only 2 patients had symptoms of congestive heart failure or angina after aortic valve replacement. CONCLUSIONS: Aortic valve replacement may be performed with a low mortality rate, excellent palliation of symptoms, and prolongation of survival in selected high-risk patients with a history of previous balloon aortic valvuloplasty.

Actuarial Analysis↗

In vivo validation of compensatory enlargement of atherosclerotic coronary arteries.

Necropsy examinations and epicardial ultrasound studies have suggested that atherosclerotic coronary arteries undergo compensatory enlargement. This increase in vessel size may be an important mechanism for maintaining myocardial blood flow. It also is of fundamental importance in the angiographic study of coronary disease progression and regression. The purpose of this study was to determine, using intracoronary ultrasound, whether coronary arteries undergo adaptive expansion in vivo. Forty-four consecutive patients were studied (30 men, 14 women; mean age 56 +/- 10 years). Eighty intravascular ultrasound images were analyzed (32 left main, 23 left anterior descending and 25 right coronary arteries). Internal elastic lamina area, a measure of overall vessel size increased as plaque area expanded (r = 0.57, p = 0.0001, SEE = 5.5 mm2). When the left main, left anterior descending and right coronary arteries were examined individually, there continued to be as great or greater positive correlation between internal elastic lamina and plaque area (left anterior descending: r = 0.75, p = 0.0001; right coronary arteries: r = 0.63, p = 0.0007; left main: r = 0.56, p = 0.0009), implying that each of the vessels and all in aggregate underwent adaptive enlargement. When only those vessels with < 30% area stenosis were examined, internal elastic lamina correlated well with plaque area (r = 0.79, and p = 0.0001), and for each 1 mm2 increase in plaque area, internal elastic lamina increased 2.7 mm2. This suggests that arterial enlargement may overcompensate for early atherosclerotic lesions.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Unrecognized left main coronary artery disease in patients undergoing interventional procedures.

Selective, coronary arteriographic, catheter-based, intravascular ultrasound images were obtained to determine the presence and extent of angiographically undetected or underestimated left main (LM) coronary arterial narrowing in patients receiving coronary interventional therapy. Coronary arteriograms were determined to be either normal or abnormal by visual inspection. Abnormal arteriograms were digitized and quantitated using a semiautomated edge-detection algorithm. Thirty-eight patients receiving percutaneous treatment of stenoses in the left coronary artery system were studied. Optimal LM coronary angiograms were obtained in 2 views, and intravascular ultrasound images were obtained after the coronary interventional procedure. Intravascular ultrasound detected plaque in 24 of 27 angiographically normal LM arteries (89%), whereas narrowing was observed in 11 of 11 angiographically abnormal LM arteries (100%). Eight of 38 patients (21%) had > 40% area stenosis by intravascular ultrasound. In patients with angiographic disease, there was no correlation between quantitative angiographic and ultrasound percent area stenosis (r = 0.12; p = 0.72; SEE 19%). The median plaque area was not different between angiographically normal (0.05 cm2; 0.03, 0.08 [25th, 75th percentile]) and abnormal (0.06 cm2; 0.03, 0.1) patients. The median percent area stenosis in arteriographically normal subjects (26%; 14, 32%) was less than that in abnormal ones (37%; 20, 46%) (p = 0.03). Unrecognized LM disease is widespread and often underestimated in patients with normal LM angiograms undergoing interventional procedures. Plaque area is similar for angiographically normal and insignificantly abnormal vessels. This study suggests that intravascular ultrasound overcomes the limitations of silhouette imaging and can be a clinically useful, adjunctive method to evaluate LM coronary artery disease.

Algorithms↗

Ultrasound guide wire-directed stent deployment.

A new mechanically rotated 20 MHz intravascular ultrasound guide wire (0.032 inch) with a transducer core was placed through the central lumen of a peripheral arterial balloon-expandable stent. Using an anesthetized canine model, 11 stents were then deployed into the iliac or femoral arteries. Eight stents were successfully deployed with proper position and full stent expansion documented by ultrasound imaging. Four of the stents were overlapping and the double row of stent struts at the region of overlap was easily seen. Three stents were unsuccessfully deployed because of undersizing, as clearly documented by ultrasound imaging showing stent strut recoil. As a result, the procedure was modified by performing ultrasound measurements of arterial dimensions before stent selection. There were no complications attributed to the ultrasound guide wire. This study demonstrates an effective combination of diagnostic and therapeutic devices that may allow more precise placement of intravascular stents.

Animals↗

Intracoronary ultrasound predictors of adverse outcomes after coronary artery interventions.

OBJECTIVES: The purpose of this study was to determine the association between qualitative and quantitative lesion characteristics as assessed by intracoronary ultrasound imaging and adverse outcomes after coronary artery interventions. BACKGROUND: Restenosis and other adverse outcomes after coronary artery interventions may be difficult to predict from clinical or angiographic data. Intracoronary ultrasound imaging provides additional data that could prove useful. METHODS: Immediately after successful coronary artery interventions (angiographic residual stenosis < or = 50%), 69 patients underwent intracoronary ultrasound imaging. Images were assessed qualitatively for plaque composition and topography and for dissection. Quantitative data included measurement of minimal lumen diameter, lumen area, plaque area and percent area stenosis at the treatment and adjacent reference sites. Adverse outcome was defined as death, coronary bypass surgery, myocardial infarction or angiographic restenosis. RESULTS: Of the 69 patients, 1 died, 3 had bypass surgery and 1 had a myocardial infarction before planned 6-month repeat catheterization. Two patients were lost to follow-up study. Of the remaining 62 patients, 56 (90%) agreed to follow-up catheterization and 25 (45%) of the 56 had restenosis. Thus, 30 patients had an adverse outcome and 37 had no adverse event. The incidence of dissection detected by ultrasound imaging after an intervention was significantly greater in patients with than in those without a subsequent adverse event (63% vs. 35%, p < 0.05). The severity of dissection also appeared to be related to outcome (p < 0.05). Other qualitative and quantitative variables were not significantly different between the two patient groups. CONCLUSIONS: Dissection, as assessed by intracoronary ultrasound imaging after a coronary artery intervention, can identify patients at increased risk of subsequent adverse events. Additional studies are warranted to explore whether such imaging may allow modification of interventional procedures to improve outcome.

Angioplasty, Balloon, Coronary↗

Left ventricular filling and ventricular diastolic performance after percutaneous balloon mitral valvotomy.

The time course of left ventricular (LV) filling and LV diastolic performance were examined in 27 consecutive patients in sinus rhythm before and acutely after balloon mitral valvotomy (BMV). The mitral valve area acutely increased from 1.1 +/- 0.3 to 2.1 +/- 0.8 cm2. Simultaneous pressure-volume data were obtained using digital subtraction left ventriculography and LV micromanometer pressure before and 10 minutes after BMV. The time constant of LV isovolumic relaxation was unchanged after BMV (50 +/- 10 ms before BMV vs 47 +/- 13 ms after BMV). In addition, values before and after BMV for LV end-diastolic volume (123 +/- 29 vs 125 +/- 36 ml), end-diastolic pressure (11 +/- 4 vs 12 +/- 4 mm Hg) and diastolic filling time (337 +/- 126 vs 338 +/- 152 ms) were not altered by the procedure. After BMV the peak diastolic filling rate (403 +/- 143 vs 469 +/- 302 ml/s) was maintained despite a 36% reduction in left atrial filling pressure. There was a trend toward earlier occurrence of the peak filling rate (196 +/- 127 vs 146 +/- 148 ms, p = 0.08). The percentage of diastolic filling in the first third of diastole, however, was similar (42 +/- 9 vs 48 +/- 16%) before and after the procedure. Thus, the time course of LV filling is not significantly altered acutely after BMV, but is maintained at reduced left atrial filling pressure. Neither LV relaxation or LV chamber compliance are altered acutely after BMV.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Prospective analysis of possible myocardial damage or hemolysis occurring as a result of prolonged autoperfusion angioplasty in humans.

OBJECTIVES: The purpose of this study was to further explore the procedural safety of prolonged (15-min) dilation using an autoperfusion coronary angioplasty balloon by assessing the degree of myocardial damage or hemolysis, if any, occurring as a result of the procedure. BACKGROUND: Prolonged balloon inflation periods may be beneficial during percutaneous transluminal coronary angioplasty. The duration of standard balloon angioplasty is often limited by the occurrence of myocardial ischemia due to loss of anterograde blood flow. Autoperfusion angioplasty allows continued myocardial perfusion during balloon inflation and has previously been shown to reduce but not totally eliminate acute myocardial ischemia during prolonged (up to 15 min) balloon inflation. The risk of intravascular hemolysis as a result of autoperfusion angioplasty has not yet been fully delineated. METHODS: Sixty-two consecutive patients (76% men; mean age 58 years) undergoing elective percutaneous transluminal coronary angioplasty of a single lesion were studied. Serial electrocardiographic and creatine kinase MB isoenzyme data were examined to detect evidence of myocardial damage. Tests for hemolysis (plasma free hemoglobin, serum haptoglobin and serum lactate dehydrogenase) were obtained in the 1st 24 consecutive patients. RESULTS: Inflation time was 14 +/- 4 min (mean +/- SD) and the procedure was successful (less than or equal to 50% residual lesion stenosis) in 59 patients (95%). Electrocardiographic evidence of myocardial infarction (greater than 1 mm persistent ST segment depression, greater than 1 mm ST segment elevation or new Q waves) was not observed in any patient. Cardiac enzyme assays were within the normal range in all patients. No evidence of hemolysis was found in the 24 consecutive patients studied. CONCLUSIONS: We conclude that prolonged autoperfusion angioplasty can be performed in patients without clinical evidence of myocardial damage or hemolysis.

Aged↗

Mechanisms of balloon angioplasty and directional coronary atherectomy as assessed by intracoronary ultrasound.

OBJECTIVE: This study was designed to use intracoronary ultrasound imaging to elucidate the physical effects of balloon angioplasty and directional coronary atherectomy in vivo in humans. BACKGROUND: The proposed mechanisms of coronary artery interventions such as balloon angioplasty and directional atherectomy are based on animal studies or pathologic findings and these data may not be applicable to living patients. Intracoronary ultrasound findings correlate highly with pathologic results and may allow in vivo assessment of the mechanisms of such interventions in humans. METHODS: Intracoronary ultrasound imaging was performed in 45 patients after a successful coronary intervention (balloon angioplasty in 30, directional coronary atherectomy in 15). Ultrasound images obtained at the treatment site and at an adjacent angiographically normal references site were analyzed quantitatively for minimal lumen diameter, cross-sectional lumen area, are enclosed by the internal elastic lamina, plaque area (internal elastic lamina area--lumen area) and percent area stenosis (plaque area/internal elastic lamina area). Qualitative analysis included assessment of presence of dissection, plaque composition and plaque topography. RESULTS: The results of the two procedures were similar with respect to minimal lumen diameter (angioplasty 2.6 +/- 0.5 vs. atherectomy 2.6 +/- 0.3 mm, p = NS), lumen area (0.07 +/- 0.03 vs. 0.07 +/- 0.02 cm2, p = NS) and percent area stenosis (59 +/- 14% vs. 51 +/- 21%, p = NS). However, after angioplasty, the internal elastic lamina area was significantly larger at the treated site than at the reference site (delta = +0.03 +/- 0.04 cm2, p = 0.01). There was no significant difference between the two sites after atherectomy (delta = -0.01 +/- 0.05 cm2, p = NS). In addition, dissection was seen significantly more often after balloon angioplasty than after atherectomy (50% vs. 7%, p less than 0.01). The results were similar when stratified for plaque composition and morphology. These data were confirmed in six additional patients who underwent ultrasound imaging before and after the intervention. CONCLUSIONS: Thus, the improvement in lumen dimensions after coronary balloon angioplasty is a result of both vessel stretch, demonstrated by a larger internal elastic lamina area at the treated site, and dissection. Both vessel stretch and dissection are uncommon after atherectomy, a finding consistent with plaque removal as the major mechanism for improved lumen area after this procedure.

Adult↗

Real-time assessment of experimental arterial angioplasty with transvenous intravascular ultrasound.

Optimal evaluation of experimental angioplasty procedures would allow real-time simultaneous assessment during the procedure without direct manipulation of treated arterial segments. To assess the feasibility and utility of transvenous real-time intravascular ultrasound imaging during experimental angioplasty, 11 consecutive atherosclerotic iliac artery segments in rabbits were imaged before, during and after thermal or conventional perfusion balloon angioplasty. A 20-MHz intravascular ultrasound catheter was positioned in the adjacent vein, and images were correlated with data from quantitative angiography and histologic studies. Images suitable for analysis were obtained at all 11 sites. Arterial distension and recoil were observed during balloon inflation and deflation. Measurements of lumen diameter and cross-sectional area by intravascular ultrasound and angiography were closely correlated (r2 = 0.90, SEE = 0.2 mm, and r2 = 0.90, SEE = 0.8 mm2, respectively). Intimal dissections were identified in six segments by intravascular ultrasound and all were concordant with histologic findings. Thus, real-time transvenous ultrasound avoids manipulation of the treated artery, and is a feasible modality for dynamic quantitative and qualitative assessment of arterial interventions.

Angiography, Digital Subtraction↗

Ergonovine maleate testing during cardiac catheterization: a 10-year perspective in 3,447 patients without significant coronary artery disease or Prinzmetal's variant angina.

The utility of ergonovine testing for coronary artery spasm was assessed in 3,447 patients with angiographically insignificant (less than 50% diameter stenosis) or no coronary artery disease. No patients clinically had Prinzmetal's variant angina. Overall, 4% had a positive ergonovine test result, defined by spasm causing greater than or equal to 75% focal stenosis. Complications related to ergonovine use occurred in 11 patients (0.03%). In a training sample of 1,136 patients (studied between 1980 and 1984), two independent predictors of spasm were found by using multivariate analysis: the amount of visible coronary artery disease on the coronary angiogram (p less than 0.0001) and a smoking history (p = 0.001). A model to predict spasm based on these variables was validated in a test group of 2,311 patients who received ergonovine from 1985 to 1989. This model allowed the identification of a subset of 400 patients in the validation sample who had a 10% positive test rate compared with a 2% positive test rate in the remaining patients. These results should permit clinicians who use provocative testing in the catheterization laboratory to reserve testing for the subset of this group of patients most likely to have abnormal findings.

Angina Pectoris, Variant↗

Fistula dysfunction: effect on rapid hemodialysis.

Rapid hemodialysis (Qb 400 to 500 ml/min) places considerable demands on hemodialysis vascular access. This six-month prospective study enrolled 52 patients and evaluated urea recirculation as a means of detecting fistula dysfunction. It evaluated the effects of fistula location and dialysis blood flow on urea recirculation during rapid hemodialysis and assessed the effect of rapid dialysis on fistula thrombosis. Urea recirculation increased as Qb increased from 300 to 400 ml/min (8 +/- 3% to 16 +/- 3%, P less than 0.05). The extent of urea recirculation was also fistula site dependent (radial fistulas 18 +/- 4%, upper arm fistulas 11 +/- 3%, Qb 400 ml/min, P less than 0.05). Site and blood flow dependent urea recirculations were an indicator of venous stenoses. When venous stenoses were corrected, urea recirculation rates improved (36 +/- 3% to 21 +/- 3%, P less than 0.05). There were no differences between methods of determining urea recirculation early in dialysis (contralateral arm venepuncture vs. stop flow technique; 30 to 60 min). However, at 120 minutes urea recirculation was significantly greater with the contralateral arm venepuncture technique. Venous dialysis pressure at Qb 400 ml/min had limited use as a predictor of venous stenoses unlike its value at lower Qb. Fistula thrombosis (0.26/patient year of dialysis) and fistula replacement (0.09/patient year of dialysis) were similar to our observations in a conventional hemodialysis facility where prospective correction of fistula dysfunction was also used.

Arteriovenous Shunt, Surgical↗

Balloon mitral commissurotomy after previous surgical commissurotomy. The National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry participants.

BACKGROUND: Mitral restenosis after surgical mitral commissurotomy often occurs within 5-15 years, necessitating a repeat procedure. Balloon mitral commissurotomy (BMC) has been advocated as an alternative to repeat surgery for mitral restenosis. METHODS AND RESULTS: The purposes of this study are to determine the short- and intermediate-term outcomes of patients undergoing BMC after previous surgical commissurotomy, to compare these patients with those undergoing balloon mitral commissurotomy as an initial procedure, and to elucidate the multivariate determinants of acute procedural and clinical outcome. Of 738 patients undergoing BMC as part of the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry, 133 underwent BMC after previous surgical mitral commissurotomy. Prospective data obtained included demographic, hemodynamic, echocardiographic, and clinical follow-up. BMC after previous surgical commissurotomy produced a significant reduction in transvalvular gradient from 13 +/- 5 to 6 +/- 3 mm Hg (p less than 0.0001) and an increase in mitral valve area from 1.0 +/- 0.3 to 1.8 +/- 0.8 cm2 (p less than 0.0001). BMC as an initial procedure increased valve area from 1.0 +/- 0.4 to 2.0 +/- 0.8 cm2 (p less than 0.0001) (p = 0.03 versus prior surgery). Baseline characteristics including mitral valve echo score were similar for both groups. Comparing 6-month status in patients with prior surgery to those without, 80% versus 90% were New York Heart Association (NYHA) functional class I or II (p = 0.004). Mortality was similar. In patients with previous mitral valve surgery, multivariate predictors of improvement in 6-month clinical status included the experience of the center (p = 0.006), lower echocardiographic score (p = 0.001), and lower left ventricular end-diastolic pressure (p = 0.008). Multivariate determinants of a final mitral valve area greater than or equal to 1.5 cm2 were a lower baseline NYHA functional class (p = 0.003) and lower mitral valve echocardiographic score (p = 0.008). CONCLUSIONS: BMC after previous surgical mitral commissurotomy results in similar hemodynamic changes as in patients undergoing BMC as an initial procedure. Symptomatic improvement at 6 months is slightly less frequent in prior commissurotomy patients. Patients with favorable valvular morphology and preserved left ventricular function who undergo BMC in experienced centers are most likely to achieve symptomatic improvement after previous surgical commissurotomy. In general, BMC is an effective treatment for mitral restenosis after previous surgical commissurotomy.

Catheterization↗

Critical mitral stenosis causing ischemic hepatic failure. Successful treatment by percutaneous balloon mitral valvotomy.

We report a 52-year-old patient with severe mitral stenosis who developed new onset atrial fibrillation, low output congestive heart failure and fulminant ischemic hepatic failure with subsequent severe coagulopathy. Percutaneous mitral valvotomy resulted in dramatic clinical improvement with complete resolution of liver function. This case illustrates the potential life-saving role for percutaneous balloon mitral valvotomy in treating critically ill patients who are unable to undergo thoracotomy due to coexisting medical illness.

Atrial Fibrillation↗

Renal artery stenosis: prevalence and associated risk factors in patients undergoing routine cardiac catheterization.

The purposes of this study were to determine the prevalence of angiographically significant renal artery stenosis in a patient population referred for diagnostic cardiac catheterization and to develop a model that predicts the highest-risk subset of patients who have significant renal artery narrowing. A prospective validation cohort study was undertaken in a referral-based university hospital. After left ventriculography, abdominal aortography was performed to screen for the presence of renal artery disease. A convenience sample of 1,302 of 1,651 consecutive patients undergoing diagnostic cardiac catheterization were enrolled in the study. Of the 1,302 abdominal aortograms performed, 1,235 (95%) were deemed of adequate quality for the evaluation of renal artery anatomy. Renal artery disease was identified in 30% of the patients. Insignificant renal artery stenosis was found in 187 (15%) and significant (greater than or equal to 50% diameter narrowing) stenosis was found in 188 (15%). Significant unilateral disease was present in 11%, and bilateral disease was present in 4%. By univariable and multivariable logistic regression analysis, the association of both clinically and catheterization-derived variables with renal artery disease was assessed. Multivariable predictors included age, severity of coronary artery disease, congestive heart failure, female gender, and peripheral vascular disease. Hypertension was not an associated variable. These data reveal the previously undetected high prevalence of renal artery disease in patients undergoing cardiac catheterization and provide clinical and angiographic features that assist in predicting its presence.

Aged↗

Intracoronary ultrasound evaluation of interventional technologies.

The feasibility and applicability of intravascular ultrasound (IVUS) of the coronary arteries were evaluated in 65 patients undergoing 70 coronary interventional procedures. Morphologic and quantitative analyses were performed with a mechanically rotated IVUS catheter (4.8Fr, 20 MHz) and with orthogonal view cineangiography. A semiautomated edge-detection algorithm was used for cineangiographic quantification. Coronary interventions included 45 percutaneous transluminal coronary angioplasties, 9 excimer lasers, 11 directional coronary atherectomies, 3 rotational atherectomies and 2 stents. Most lesions consisted of a mixture of plaque composition (hard, n = 30; soft, n = 64). Other unique morphologic data by IVUS were plaque topography (eccentric, n = 34; concentric, n = 36) and vessel dissection (IVUS [n = 29] versus angiography [n = 14], p less than 0.05). Postprocedure minimal lumen diameter and cross-sectional area measured by IVUS were larger and poorly correlated with angiography (r = 0.28, standard error of the estimate = 0.52 mm; r = 0.08, standard error of the estimate = 1.0 cm2, respectively). IVUS is more sensitive than angiography when assessing postintervention lesion characteristics including vessel dissection and plaque morphology. Catheter-based ultrasound appears to be a useful adjunct to contrast angiography when evaluating and comparing the therapeutic impact of conventional percutaneous transluminal coronary angioplasty with new technologies.

Algorithms↗