Search PubMed⌕ Search

Biomedical subjects

C J D'Orsi

Publications and source records attributed to C J D'Orsi.

At least 19 recordsLinked to original sources

Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography.

RATIONALE AND OBJECTIVES: The purpose of this study was to comparatively evaluate digital planar mammography and both linear and nonlinear tomosynthetic reconstruction methods. MATERIALS AND METHODS: A "disk" (ie, target) identification study was conducted to compare planar and reconstruction methods. Projective data using a composite phantom with circular disks were acquired in both planar and tomographic modes by using a full-field, digital mammographic system. Two-dimensional projections were reconstructed with both linear (ie, backprojection) and nonlinear (ie, maximization and minimization) tuned-aperture computed tomographic (TACT) methods to produce three-dimensional data sets. Four board-certified radiologists and one 4th-year radiology resident participated as observers. All images were compared by these observers in terms of the number of disks identified. RESULTS: Significant differences (P < .05, Bonferroni adjusted) were observed between all reconstruction and planar methods. No significant difference, however, was observed between the planar methods, and only a marginally significant difference (P < .054, Bonferroni adjusted) was observed between TACT-backprojection and TACT-minimization. CONCLUSION: A combination of linear and nonlinear reconstruction schemes may have potential implications in terms of enhancing image visualization to provide radiologists with valuable diagnostic information.

Breast Neoplasms↗

Comparison of full-field digital mammography with screen-film mammography for cancer detection: results of 4,945 paired examinations.

PURPOSE: To prospectively compare full-field digital mammography (FFDM) with screen-film mammography (SFM) for cancer detection in a screening population. MATERIALS AND METHODS: At two institutions, 4,945 FFDM examinations were performed in women aged 40 years and older presenting for SFM. Two views of each breast were acquired with each modality. SFM and FFDM images were interpreted independently. Findings detected with either SFM or FFDM were evaluated with additional imaging and, if warranted, biopsy. RESULTS: Patients in the study underwent 152 biopsies, which resulted in the diagnosis of 35 breast cancers. Twenty-two cancers were detected with SFM and 21 with FFDM. Four were interval cancers that became palpable within 1 year of screening and were considered false-negative findings with both modalities. The difference in cancer detection rate was not significant. FFDM had a significantly lower recall rate (11.5%; 568 of 4,945) than SFM (13.8%; 685 of 4,945) (P <.001, McNemar chi(2) model; P <.03, generalized estimating equations model). The positive biopsy rate for findings detected with FFDM (30%; 21 of 69) was higher than that for findings detected with SFM (19%; 22 of 114), but this difference was not significant. CONCLUSION: No difference in cancer detection rate has yet been observed between FFDM and SFM. FFDM has so far led to fewer recalls than SFM.

Biopsy↗

Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

An amorphous silicon-based full-breast imager for digital mammography was evaluated for detector stability over a period of 1 year. This imager uses a structured CsI:TI scintillator coupled to an amorphous silicon layer with a 100-micron pixel pitch and read out by special purpose electronics. The stability of the system was characterized using the following quantifiable metrics: conversion factor (mean number of electrons generated per incident x-ray), presampling modulation transfer function (MTF), detector linearity and sensitivity, detector signal-to-noise ratio (SNR), and American College of Radiology (ACR) accreditation phantom scores. Qualitative metrics such as flat field uniformity, geometric distortion, and Society of Motion Picture and Television Engineers (SMPTE) test pattern image quality were also used to study the stability of the system. Observations made over this 1-year period indicated that the maximum variation from the average of the measurements were less than 0.5% for conversion factor, 3% for presampling MTF over all spatial frequencies, 5% for signal response, linearity and sensitivity, 12% for SNR over seven locations for all 3 target-filter combinations, and 0% for ACR accreditation phantom scores. ACR mammographic accreditation phantom images indicated the ability to resolve 5 fibers, 4 speck groups, and 5 masses at a mean glandular dose of 1.23 mGy. The SMPTE pattern image quality test for the display monitors used for image viewing indicated ability to discern all contrast steps and ability to distinguish line-pair images at the center and corners of the image. No bleeding effects were observed in the image. Flat field uniformity for all 3 target-filter combinations displayed no artifacts such as gridlines, bad detector rows or columns, horizontal or vertical streaks, or bad pixels. Wire mesh screen images indicated uniform resolution and no geometric distortion.

Female↗

Comparison of tomosynthesis methods used with digital mammography.

RATIONALE AND OBJECTIVES: The authors performed this study to investigate the potential applicability of tomosynthesis to digital mammography. Four methods of tomosynthesis-tuned aperture computed tomography (TACT)-backprojection, TACT-iterative restoration, iterative reconstruction with expectation maximization, and Bayesian smoothing-were compared to planar mammography and analyzed in terms of their contrast-detail characteristics. Specific comparisons between the tomosynthesis methods were not attempted in this study. MATERIALS AND METHODS: A full-field, amorphous, silicon-based, flat-panel digital mammographic system was used to obtain planar and tomosynthesis projection images. A composite tomosynthesis phantom with a centrally located contrast-detail insert was used as the object of interest. The total exposure for multiple views with tomosynthesis was always equal to or less than that for the planar technique. Algorithms were used to reconstruct the object from the acquired projections. RESULTS: Threshold contrast characteristics with all tomosynthesis reconstruction methods were significantly better than those with planar mammography, even when planar mammography was performed at more than twice the exposure level. Reduction of out-of-plane structural components was observed in all the tomosynthesis methods analyzed. CONCLUSION: The contrast-detail trends of all the tomosynthesis methods analyzed in this study were better than those of planar mammography. Further optimization of the algorithms could lead to better image reconstruction, which would improve visualization of valuable diagnostic information.

Breast Neoplasms↗

Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-illuminated 61 x 61 mm CCD operating at a pixel pitch of 30 microns. Objective criteria such as modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), and noise equivalent quanta (NEQ) were employed for this evaluation. The results demonstrated a limiting spatial resolution (10% MTF) of 10 cy/mm. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 40% at close to zero spatial frequency at an exposure of 8.2 mR, and decreases to approximately 28% at a low exposure of 1.1 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Calibration↗

Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Algorithms↗

Potential contribution of computer-aided detection to the sensitivity of screening mammography.

PURPOSE: To determine the false-negative rate in screening mammography, the capability of computer-aided detection (CAD) to identify these missed lesions, and whether or not CAD increases the radiologists' recall rate. MATERIALS AND METHODS: All available screening mammograms that led to the detection of biopsy-proved cancer (n = 1,083) and the most recent corresponding prior mammograms (n = 427) were collected from 13 facilities. Panels of radiologists evaluated the retrospectively visible prior mammograms by means of blinded review. All mammograms were analyzed by a CAD system that marks features associated with cancer. The recall rates of 14 radiologists were prospectively measured before and after installation of the CAD system. RESULTS: At retrospective review, 67% (286 of 427) of screening mammography-detected breast cancers were visible on the prior mammograms. At independent, blinded review by panels of radiologists, 27% (115 of 427) were interpreted as warranting recall on the basis of a statistical evaluation index; and the CAD system correctly marked 77% (89 of 115) of these cases. The original attending radiologists' sensitivity was 79% (427 of [427 + 115]). There was no statistically significant increase in the radiologists' recall rate when comparing the values before (8.3%) with those after (7.6%) installation of the CAD system. CONCLUSION: The original attending radiologists had a false-negative rate of 21% (115 of [427 + 115]). CAD prompting could have potentially helped reduce this false-negative rate by 77% (89 of 115) without an increase in the recall rate.

Adult↗

Communication issues in breast imaging.

It is hoped that this discussion makes it clear that unambiguous communication to the woman and health care provider is extremely desirable. This communication along established guidelines using standardized terminology should diminish lack of appropriate follow-up with its inherent negative outcomes.

Communication↗

Methods to calculate the lens efficiency in optically coupled CCD x-ray imaging systems.

In lens-coupled CCD x-ray imaging, the lens efficiency is of critical importance for attaining an x-ray quantum-noise-limited system. However, the equations and the associated parameters of this process have not always been used properly in some of the literature. This can result in the incorrect estimation of the signal-to-noise ratio (SNR). In practice, it is found more convenient to use lens-coupling efficiency equations which assume that the scintillating screen is an extended Lambertian source, since the number of light photons emerging from various scintillating screens has been measured and reported by several investigators. This communication examines several of the most common types of lens-coupling efficiency equations and explains how to use them correctly with other parameters to calculate the SNR of a lens-coupled CCD x-ray imaging system.

Biophysical Phenomena↗