Search PubMed⌕ Search

Biomedical subjects

C J Buckley

Publications and source records attributed to C J Buckley.

43 records · Page 3Linked to original sources

Economic considerations for aortic surgery: retroperitoneal approach--is it worth it?

BACKGROUND: Planned reductions in reimbursement for all forms of vascular surgery dictate a need for the development of more cost efficient, yet quality oriented, treatment programs. We are faced with an increasingly older patient population with multiple comorbidities. In this environment it will become extremely difficult to accomplish aortic surgery in a way which will be profitable for our hospitals. More than 100,000 aortic surgeries are performed annually in the United States. Previous reports suggest that earlier hospital discharges and reduced postoperative complications occur when a retroperitoneal approach is used for aortic surgery. Other publications refute this concept. In an effort to determine the most cost efficient method for aortic surgery in our institution, while maintaining high standards of care and outcome, we compared the retroperitoneal approach to the conventional transperitoneal aortic operation. PATIENTS AND METHODS: Between December 1995 and April 1998, 120 patients underwent aortic surgery by either the transperitoneal (n = 60) or retroperitoneal approach (n = 60). All patients were enrolled prospectively in a vascular registry and retrospectively reviewed. Patients were randomly assigned to one of three vascular surgeons. A clinical pathway for elective aortic surgery was developed and applied to both groups. Patients were evaluated with respect to demographics, comorbidities, preoperative risk stratification, conduct of the operative procedure, length of stay, complications, cost, clinical outcomes and patient satisfaction. The indications for aortic surgery were similar in both groups--64% for aneurysm disease and 36% for occlusive disease. Both symptomatic and asymptomatic aneurysms were included and size ranged from 4.4 cm to 14 cm. All aortic reconstructions were done in the standard manner using knitted Dacron velour prostheses in either the aortic tube, bi-iliac or bi-femoral configuration. Statistical analysis of means and medians was accomplished using the Wilcoxin Rank-sum test and percentages were compared using Fisher's Exact test. P values less than 0.05 indicate statistical significance. RESULTS: There were no statistically significant differences in patient demographics. The incidence of atherosclerotic coronary artery disease, obstructive pulmonary disease, diabetes, hyperlipidemia, tobacco abuse, distal lower extremity occlusive disease and the results of chemical myocardial stress evaluations were similar in both groups. Comorbidities of preexisting renal insufficiency/failure and morbid obesity were increased in the retroperitoneal group. Five patients in the retroperitoneal group represented redo aortic surgery and there were no redo procedures in the transperitoneal group. Length of operative procedures and blood replacement requirements for both groups were similar. The transperitoneal group required 2-3 liters more intraoperative intravenous (i.v.) crystalloid than the retroperitoneal group (p < 0.0001). Statistically significant reductions in ICU days, postoperative ileus and total lengths of stay were observed in the retroperitoneal group (p < 0.0001). This resulted in substantial reductions in hospital costs for the retroperitoneal group (p < 0.01). Postoperative complications were similar for both groups except for statistically significant increases in pulmonary edema (p < 0.01) and pneumonia (p < 0.001) in the transperitoneal group. Cardiac arrhythmias, primarily atrial dysrhythmias, were more frequent in the transperitoneal group but this failed to reach statistical significance (p < 0.16). Combined thirty day mortality was 0.9%. Time of recovery to full activity and patient satisfaction substantially favored the retroperitoneal group. CONCLUSION: Our clinical pathway and algorithm for aortic surgery was easily followed by those patients in the retroperitoneal approach group and resulted in decreases in ICU time, postoperative ileus, volume of intraoperative crystalloid and total length of stay. The patients in the transperitoneal group often failed to progress appropriately on the pathway. Reduced hospital costs associated with aortic surgery using the retroperitoneal approach has increased the profitability for this surgery in our institution by an average of $4000 per case and has increased the value (quality/cost) of this surgery to our patients and our institution. This was accomplished in an academic environment with surgical residency training where cost containment has historically been difficult.

Aorta↗

Instrumentation and examination procedures for a clinical vascular laboratory.

Instrumentation and examination procedures used in the clinical vascular Laboratory of the Massachusetts General Hospital are outlined and recommended for use in other similar laboratories. The arterial system is studied by the analysis of blood flow direction, segmental plethysmography, and systolic pressure measurements obtained at rest and following a measured exercise stress. The effect of induced reactive hyperemia on systolic pressure, obtained by direct intra-arterial measurement, is used to demonstrate the hemodynamic importance of stenotic lesions within the aorto-iliac system. Maximum venous outflow studies are combined with analyses of venous Doppler signals for purposes of screening patients with suspected deep venous thrombosis. The laboratory contributes important objective physiologic information to the examination of the arterial and venous systems. Experience obtained through the evaluationof more than 2500 patients resulted in the development of this recommended program.

Clinical Laboratory Techniques↗