Search PubMed⌕ Search

Biomedical subjects

C Haisch

Publications and source records attributed to C Haisch.

At least 19 recordsLinked to original sources

Development and characterization of a mobile photoacoustic sensor for on-line soot emission monitoring in diesel exhaust gas.

Upcoming regulations for vehicle exhaust emission demand substantial reduction of particle emission in diesel exhaust. To achieve these emission levels, the car manufacturing industry is developing new combustion concepts and exhaust after-treatment techniques such as the use of catalysts and particle filters. Many of the state-of-the-art analytical instruments do not meet the required detection limits, in combination with a high temporal resolution necessary for engine optimization. This paper reports a new detection system and the first results of its application to on-line diesel exhaust soot measurements on a engine test bench (MAN diesel engine facility Nürnberg, Germany). The instrument is based on differential photoacoustic (PA) spectroscopy of black carbon aerosol. It contains two identical PA cells, one for the measurement of the aerosol particles and one which analyses the particle-free gas. Thus, a potential cross-sensitivity to gaseous absorbers in the exhaust gas can be excluded. The PA cells were characterized in a laboratory set-up, with water vapor as reference gas and artificial soot generated by a spark discharge generator. The detection limit was found to be 2 microg m(-3) BC (for diesel soot) with a sampling rate of 3 Hz. The temporal response of the system was found to be in the order of 1 s. After full characterization of the cells, the system was transferred into a mobile 19"-rack. Characterization of the mobile sensor system under real-world conditions was performed during several measurement campaigns at an engine test bench for heavy-duty diesel engines. Results for the limit of detection, the time resolution, accuracy, repeatability, and robustness of the sensor system are very promising with regards to a routine application of the system in engine development.

Journal Article↗

On-line monitoring of opaque liquids by photoacoustic spectroscopy.

A new photoacoustic sensor system for on-line monitoring of highly concentrated and optical opaque liquid samples is presented. The dyeing of textiles is performed with highly concentrated dye solutions with concentrations ranging from 50 mg L(-1) up to 40 g L(-1). For process optimization and control of the wastewater, an on-line monitoring of the dye concentration is needed. Optical transmission measurements allow the determination of the dye concentration in a relatively small range. Samples with concentrations in the upper mg L(-1) and g L(-1) range have to be diluted before the measurement due to their optical opacity. Additionally, light-scattering particles have a strong effect on the transmitted light intensity. By photoacoustic spectroscopy, concentrations in condensed matter can be determined over several orders of magnitude. Furthermore, scattering particles do not generate any photoacoustic signal.

Journal Article↗

Process analysis of biofilms by photoacoustic spectroscopy.

Biofilms are aggregates of microorganisms and biopolymers which occur at aqueous interfaces. Biofilms play an important role in the degradation of pollutants in natural water systems as well as in wastewater treatment plants. In this communication, the use of photoacoustic spectroscopy (PAS) as a new biofilm monitoring technique is presented. PAS combines features of optical spectroscopy and ultrasonic tomography and allows a depth-resolved analysis of optically and acoustically inhomogeneous media. For the first time, both biofilm and bulk liquid were monitored by photoacoustic sensor heads. In this way, sorption of suspended iron(III) oxide particles on the outer and inner surfaces of the biofilm could be observed on-line and in situ. Colloids can act as carriers of pollutants and influence stability and degradation efficiency of biofilms.

Acoustics↗

Biofilm monitoring by photoacoustic spectroscopy.

The use of photoacoustic spectroscopy (PAS) as a new biofilm monitoring technique is presented. Growth and detachment of biofilms at three different positions inside a flow channel were monitored by photoacoustic measurements in the visible spectral range (lambda = 532 nm). The experimental approach allows the investigation of the influence of various process parameters (e.g. pH or flow conditions) on growth and detachment of biofilms. In addition, the distribution of the attached biomass can be monitored by depth-resolved photoacoustic measurements.

Acoustics↗

A photoacoustic technique for depth-resolved in situ monitoring of biofilms.

Biofilms occur in natural and engineered water systems. Biofouling in technical processes lowers the water quality and increases the frictional resistance in tubes. In wastewater treatment plants, biofilms are used for removal of organic an inorganic pollutants. For improvement of antifouling strategies and for process optimization in wastewater treatments plants, an analytical technique for online monitoring of biofilms is needed. In this article, a new setup for in situ monitoring of biofilms by photoacoustic spectroscopy is presented. To produce a biofilm, a mixture of microorganisms was grown in a nutrient solution inside a tube reactor. The content of the tube reactor was pumped through a flow channel, and biofilms were generated at the inner surfaces. Three photoacoustic sensor heads were integrated at different positions into the base plate of the flow channel. By photoacoustic spectroscopy, growth, thickness, and detachment of biofilms can be monitored on-line and nondestructively. Experiments presented in this article showed that the flow conditions influence the structure and thickness of biofilms. By changing the pH value, electrostatic interactions inside the biofilm matrix were influenced, and the subsequent detachment processes were observed online. The interaction of iron(III) oxide particles with biofilms led to particle adsorption on the outer and inner surfaces of the biofilm. Afterwards, biofilm flocs were sloughed off from the base biofilm.

Acoustics↗

Hypothermia--a limiting factor in using warm ischemically damaged kidneys.

A study was performed to determine the limiting factors to expanding the donor pool with warm ischemically (WI) damaged kidneys. Canine kidneys were damaged by 30 min of WI, and then either cold stored (CS) in ViaSpan (4 degrees C) for 18 h, or warm perfused with exsanguineous metabolic support (EMS) technology (32 degrees C) for 18h, or subjected to combinations of both techniques. The kidneys were autotransplanted with contralateral nephrectomy. In kidneys with WI and CS alone, the mean peak serum creatinine value was 6.3mg/dL and took 14 days to normalize. In contrast, kidneys where renal metabolism was resuscitated ex vivo during 18 h of warm perfusion demonstrated mild elevations in the serum chemistries (2.6mg/dL). The damage in kidneys CS for 18h was ameliorated with 3 h of subsequent warm perfusion and eliminated by 18 h of warm perfusion. In contrast, reversing the order with CS following WI and 18h of warm perfusion resulted in a time-dependent increase in damage. These results identify hypothermia as a major limiting factor to expanding indications for kidney donation. While hypothermia represents the foundation of preservation in the heart-beating donor, its use in WI damaged organs appears to represent a limiting factor.

Animals↗

A gene transfer method for the study of chimerism derived from donor bone marrow in organ transplant recipients.

Transduction of DBMC with the neo gene did not negatively affect the viability of DBMC or the graft-prolonging effect of DBMC infusion and provided a sensitive method to monitor DBMC-derived chimerism at a microchimeric level for at least 6 months by molecular and immunohistochemical techniques. Selection of neo-transduced DBMC with G418 prior to infusion will enable more uniform neo expression and will provide novel opportunities to further investigate chimerism in primates.

Animals↗

A gene transfer method for the study of chimerism derived from donor bone marrow in organ transplant recipients.

Transduction of DBMC with the neo gene did not negatively affect the viability of DBMC or the graft-prolonging effect of DBMC infusion and provided a sensitive method to monitor DBMC-derived chimerism at a microchimeric level for at least 6 months by molecular and immunohistochemical techniques. Selection of neo-transduced DBMC with G418 prior to infusion will enable more uniform neo expression and will provide novel opportunities to further investigate chimerism in primates.

Animals↗