Pharmacokinetics of Photogem using fluorescence monitoring in Wistar rats.

In this study we investigated the pharmacokinetics of a hematoporphyrin derivative (Photogem) in Wistar rats using the fluorescence spectroscopy to evaluate the drug distribution in liver, kidney and skin tissues. The detection system is composed of a 532 nm exciting laser, a Y-type catheter for light delivery and collection, a monochromator and a computer for data acquisition. The analysis of the fluorescence spectra was based on the intensity of porphyrin emission bands from specific tissues of the investigated organ. A simple transport model is proposed to determine the accumulation and elimination times for each type of investigated tissue. The obtained results show the viability of the fluorescence spectroscopic technique for the drug concentration monitoring in different target tissues and related pharmacokinetics. These effects should be considered before any in vivo study of Photodynamic Therapy using Photogem.

Animals↗

Experimental derivation of wall correction factors for ionization chambers used in high dose rate 192Ir source calibration.

At present there are no specific primary standards for 192Ir high dose rate sources used in brachytherapy. Traceability to primary standards is guaranteed through the method recommended by the AAPM that derives the air kerma calibration factor for the 192Ir gamma rays as the average of the air kerma calibration factors for x-rays and 137Cs gamma-rays or the Maréchal et al. method that uses the energy-weighted air kerma calibration factors for 250 kV x rays and 60Co gamma rays as the air kerma calibration factor for the 192Ir gamma rays. In order to use these methods, it is necessary to use the same buildup cap for all energies and the appropriate wall correction factor for each chamber. This work describes experimental work used to derive the A(W) for four different ionization chambers and different buildup cap materials for the three energies involved in the Maréchal et al. method. The A(W) for the two most common ionization chambers used in hospitals, the Farmer NE 2571 and PTW N30001 is 0.995 and 0.997, respectively, for 250 kV x rays, 0.982 and 0.985 for 192Ir gamma rays, and 0.979 and 0.991 for 60Co gamma rays, all for a PMMA build-up cap of 0.550 gm cm(-2). A comparison between the experimental values and Monte Carlo calculations shows an agreement better than 0.9%. Availability of the A(W) correction factors for all commercial chambers allows users of the in-air calibration jig, provided by the manufacturer, to alternatively use the Maréchal et al. method. Calibration laboratories may also used this method for calibration of a well-type ionization chamber with a comparable accuracy to the AAPM method.

Brachytherapy↗

A new approach to intraoperative radiation therapy.

Intraoperative radiation therapy (IORT) is an adjuvant treatment in which a large single dose of radiation is delivered during a surgical procedure to resected tumor beds or to an unresectable tumor. This article discusses the implementation of an IORT program and highlights the successful collaboration needed between the OR and radiation oncology departments. A better understanding of IORT in the OR setting will contribute to smooth program implementation.

Combined Modality Therapy↗

Mobile linear accelerators for intraoperative radiation therapy.

Intraoperative radiation therapy (IORT) is becoming an increasingly common procedure for treating gross tumors or tumor beds after resection. Traditionally, IORT delivery required either heavily shielded ORs or transporting anesthetized patients to the department of radiation oncology. The availability of a self-shielded mobile electron linear accelerator has made this treatment modality accessible to institutions that otherwise would not consider performing IORT. This article describes IORT equipment and supplies and addresses perioperative nursing issues, as well as the roles of other team members involved in the delivery of IORT.

Combined Modality Therapy↗

In vivo dosimetry using a single diode for megavoltage photon beam radiotherapy: implementation and response characterization.

The AAPM Task Group 40 reported that in vivo dosimetry can be used to identify major deviations in treatment delivery in radiation therapy. In this paper, we investigate the feasibility of using one single diode to perform in vivo dosimetry in the entire radiotherapeutic energy range regardless of its intrinsic buildup material. The only requirement on diode selection would be to choose a diode with the adequate build up to measure the highest beam energy. We have tested the new diodes from Sun Nuclear Corporation (called QED and ISORAD-p--both p-type) for low-, intermediate-, and high-energy range. We have clinically used both diode types to monitor entrance doses. In general, we found that the dose readings from the ISORAD (p-type) are closer of the dose expected than QED diodes in the clinical setting. In this paper we report on the response of these newly available ISORAD (p-type) diode detectors with respect to certain radiation field parameters such as source-to-surface distance, field size, wedge beam modifiers, as well as other parameters that affect detector characteristics (temperature and detector-beam orientation). We have characterized the response of the high-energy ISORAD (p-type) diode in the low- (1-4 MV), intermediate- (6-12 MV), and high-energy (15-25 MV) range. Our results showed that the total variation of the response of high-energy ISORAD (p-type) diodes to all the above parameters are within +/-5% in most encountered clinical patient treatment setups in the megavoltage photon beam radiotherapy. The usage of the high-energy buildup diode has the additional benefit of amplifying the response of the diode reading in case the wrong energy is used for patient treatment. In the light of these findings, we have since then switched to using only one single diode type, namely the "red" diode; manufacturer designation of the ISORAD (p-type) high-energy (15-25 MV) range diode, for all energies in our institution and satellites.

Feasibility Studies↗

Photodynamic therapy in oncology.

Photodynamic therapy (PDT) is a cancer treatment modality that is based on the administration of a photosensitiser, which is retained in tumour tissues more than in normal tissues, followed by illumination of the tumour with visible light in a wavelength range matching the absorption spectrum of the photosensitiser. The photosensitiser absorbs light energy and induces the production of reactive oxygen species in the tumour environment, generating a cascade of events that kills the tumour cells. The first generation photosensitiser, Photofrin (porfirmer sodium), has been approved for oesophageal and lung cancer in the US and has been under investigation for other malignant and non-malignant diseases. Sub-optimal light penetration at the treatment absorption peak of Photofrin and prolonged skin photosensitivity in patients are limiting factors for this preparation. Several new photosensitisers have improved properties, especially absorption of longer wavelength light which penetrates deeper into tissue and faster clearance from normal tissue. This paper reviews the current use of first- and second-generation photosensitisers in oncology. The use of PDT in oncology has been restricted to certain cancer indications and has not yet become an integral part of cancer treatment in general. The main advantage of PDT is that the treatment can be repeated multiple times safely, without producing immunosuppressive and myelosuppressive effects and can be administered even after surgery, chemotherapy or radiotherapy. The current work on new photosensitisers and light delivery equipment will address some of the present shortcomings of PDT. Much has been learned in recent years about the mechanisms of cellular and tissue responses to PDT and protocols designed to capitalise on this knowledge showed lead to additional improvements.

Anthraquinones↗

Photodynamic therapy: a new concept in medical treatment.

A new concept in the therapy of both neoplastic and non-neoplastic diseases is discussed in this article. Photodynamic therapy (PDT) involves light activation, in the presence of molecular oxygen, of certain dyes that are taken up by the target tissue. These dyes are termed photosensitizers. The mechanism of interaction of the photosensitizers and light is discussed, along with the effects produced in the target tissue. The present status of clinical PDT is discussed along with the newer photosensitizers being used and their clinical roles. Despite the promising results from earlier clinical trials of PDT, considerable additional work is needed to bring this new modality of treatment into modern clinical practice. Improvements in the area of light source delivery, light dosimetry and the computation of models of treatment are necessary to standardize treatments and ensure proper treatment delivery. Finally, quality assurance issues in the treatment process should be introduced.

Animals↗

A simple backup for a radiosurgery treatment planning system.

To calculate the dose distribution and the number of monitor unit (MU) per arc, all radiosurgery systems utilize some sort of computer. These computers are, of course, subject to equipment malfunction such as problems with the magnetic tape drive, keyboard, mouse, etc. Since most radiosurgery procedures are quite invasive and time consuming, it is important to have a reliable and reasonably accurate backup system for planning the treatment. This paper will show that a simple PC based system, along with a digitizer, may be used as a backup for a commercial, VAX based radiosurgery system. A complete radiosurgery planning procedure was carried out on a head phantom with a target imbedded inside. The treatment planning and verification using the PC based system is also compared with that using the VAX based system.

Computer Systems↗

A well-type ionization chamber geometric correction factor.

To correct for the influence of source configuration on the measured activity of spherical and cylindrical brachytherapy sources, a geometric correction factor was calculated for the Standard Imaging HDR-1000 well-type ionization chamber. A Fortran program modelled each source as a lattice of point sources. Because of the cylindrical symmetry of the well chamber, it could be uniquely modelled by point detectors along the perimeter of the radial plane of the detection volume. Path lengths were calculated and attenuation factors were applied to each source-detector point combination individually. The total dose rate at each detection point was found through a Sievert summation of the point source contributions. For 137Cs sources with identical activities, a correction factor of 0.965 +/- 0.005 was calculated, equal to the ratio of the dose rate of the cylindrical source to that of the sphere. Experimental verification using a Nuclear Associates 67-809 series cylindrical sources and an Amersham spherical 137Cs source yielded a correction factor of 0.958 +/- 0.016.

Brachytherapy↗

Evaluation of a well-type ionization chamber for calibration of HDL and LDR brachytherapy sources.

The Atomlab 44D well-type ionization chamber is being evaluated for calibration of high dose rate (HDR) Ir-192 and low dose rate (LDR) Cs-137 sources. The chamber has a flat response (sweet spot) of +/- 0.5% along approximately 3.5 cm for an Ir-192 HDR linear source and 3 cm for a Cs-137 LDR spherical source. The short-term stability of the chamber was determined using a cylindrical Cs-137 source positioned in the sweet spot region. The chamber response over a range of 17.4 mCi (644 MBq, Cs-137) and 8.82 Ci (326 GBq, Ir-192) is evaluated. The chamber may be used for calibrating the activities of both HDR Ir-192 and LDR brachytherapy sources.

Brachytherapy↗

A simple device for prostate and rectal localization in radiation therapy.

A simple device for prostate and rectum localization in radiation therapy may be constructed as follows: first, dental wax is used to make up a shape of the rectal probe. Second, dental stone is used to make a two-piece mold by molding the dental wax probe. Third, using the mold, the rectal probe is made from a mixture of silicone and barium. The final step involves the attachment of the "plug," which is made of aluminum. From the simulation films for the prostate setup, the location of the anterior wall of the rectum, anal sphincter, and anal verge can easily be identified, such that the appropriate regions are shielded accordingly. A CT scan with the probe in the rectum did not give too much artifacts from the barium/silicone mixture. The rectal probe with the plug is useful for localizing the prostate more accurately, compared with using the other rectal localization techniques such as barium injection or some rectal markers.

Aluminum↗

Application of the "bioeffects" algorithm of a treatment planning system.

In this study, both a four-field box and two-field AP/PA treatment plan are combined with two insertions of Cs-137 in a tandem and ovoids setup, to evaluate the bioeffects program of a treatment planning system. External beam energies studied are 18 and 6 MV. It is shown that there is a slight difference in the 50-70 time dose fractionation (TDF) isolines when comparing 6 MV and 18 MV, for the AP/PA setup. There is practically no difference for TDF isoline values larger than 80 for both energies with either the four-field or the two-field setup. This is because the brachytherapy contributed the majority of the dose to the regions near the applicator and the TDF values reflect the higher dose delivered by the brachytherapy relative to the external beams in that region. For this simple evaluation of the bioeffects program, the combination of the external beam plan and the brachytherapy plan does not give us enhanced information on the effectiveness of the plan.

Algorithms↗

Accuracy of the point source approximation to high dose-rate Ir-192 sources.

The accuracy of the point source approximation used in dose calculations for an implant comprised of multiple high dose rate (HDR) Ir-192 source dwell positions is investigated. First, a single dwell position implant is modeled. The exposure rate about the source is calculated using both the point source approximation and the more rigorous line source formalism. A comparison of these calculated exposure rates is made. It is found that for each HDR Ir-192 source dwell position, the point source approximation results in a dose overestimation of 1% at a distance of 1 cm on the source transverse axis, while dose underestimations of more than 2% can be found at a distance of 1 cm on the source longitudinal axis. Even larger errors occur closer to the source. The results of this academic study are then extended to two clinical cases--an endobronchial treatment and a tandem and ovoids setup, both involving multiple source dwell positions. Since clinical HDR Ir-192 implants are comprised of many individual source dwell positions, there will be inaccuracy in the calculated overall dose distribution leading to dose delivery errors. For example, the dose delivered to a prescription point located 0.5 cm from an endobronchial applicator will be 3% lower than prescribed. Similar errors are produced in gynecologic implants. To decrease below 0.5% the dose delivery error resulting from the point source approximation, prescription points should be at a distance of at least 1 cm from any applicator. Since the dosimetry error is a direct result of the choice of model used to describe the source, the use of anisotropy factors accounting for the variation of photon fluence around the HDR Ir-192 source will not completely correct the calculation.

Brachytherapy↗

Evaluation of dose delivery based on a comparison of dosimetry calculations using open beam and wedged beam depth dose data.

The purpose of this study is to evaluate the magnitude of the error in dose delivery caused by the use of open beam depth dose data in dosimetry calculations for wedged photon beams. Isodose plans were calculated for treatments given in a 3-field isocentric prostate or rectal setup using an open AP beam with two lateral wedged beams. The dose distributions were first calculated using open beam depth dose data for all three fields. Next, the open beam data was used only for the AP field and true wedged beam depth dose data was substituted for the two lateral wedged fields. The magnitude of the depth dose variations for wedged vs open beams depends on the nominal beam energy, the wedge angle, and the depth of measurement. Consequently, isodose distributions calculated for wedged fields were found to be different when true wedged beam depth dose data was used instead of open beam data as is commonly done. Monitor unit calculations using a field size specific wedge factor show that dose delivery errors up to 4% can result from the use of open beam depth dose data in wedged beam dose distribution calculations for a 6-MV photon beam. Accurate treatment planning for wedged fields requires the use of wedged beam depth dose data specific to each wedge. Simply using open beam depth dose data in dose calculations for wedged beams will result in dose delivery errors, the magnitude of which depends on the combination of wedge angle, field size, and nominal beam energy.

Evaluation Studies as Topic↗

The use of customized spreadsheets in radiation therapy.

A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of radiation therapy dose calculations. External beam--a spreadsheet will verify the monitor units (MU) or time required to deliver a prescribed dose to a point on an isodose line as calculated by a commercial treatment planning system. Calibration--spreadsheet programs have been developed to perform the calculations necessary for the output calibration of cobalt and high-energy photon and electron beams according to the TG-21 protocol. The user must indicate which beam, electrometer, chamber, phantom material, temperature, pressure and depth of measurement that apply. Radiosurgery--the MU per arc is calculated based on the following: the average depth per arc as obtained from a commercial radiosurgery program, the collimator size, and the prescription dose. TBI--The patient's width is entered into the spreadsheet program, which then calculates the MU needed to deliver a prescribed dose to the midline.

Humans↗

Deconvolution of detector size effect for small field measurement.

Parametrization of the small fields employed in stereotactic applications is a painstaking process involving extensive film dosimetry to achieve acceptable beam edge definition. Use of cylindrical or spherical detectors for profile measurements would simplify data acquisition but add a volume averaging artifact to beam edge definition. We demonstrate a simple approach to unfolding the chamber size artifact from measured small beam profiles using typical cylindrical chambers. In comparison with film measurements we have found good agreement when the detector response function is deconvoluted from the measured profiles, although the amount of correction needed is fairly minimal for the detectors studied.

Film Dosimetry↗