Search PubMed⌕ Search

Biomedical subjects

C H Mastrangelo

Publications and source records attributed to C H Mastrangelo.

7 recordsLinked to original sources

On-chip thermopneumatic pressure for discrete drop pumping.

A class of "lab-on-a-chip" devices use external air pressure for pumping discrete drops in a microchannel network. External air connectors can be cumbersome and are real-estate intensive. We have developed an on-chip technique to generate pressures required for metering and pumping of nanoliter-volume discrete drops. This is achieved by heating of trapped air in a pressure-generating chamber. The pressure-generating chamber is connected to the point of pressure application in the liquid-conveying microchannel through an air-delivery channel. The trapped air volume on the order of 100 nL is heated by resistive metal heaters by tens of degrees celcius to generate air pressures on the order of 7.5 kN/m2. The rate of discrete drop pumping is electronically controlled in the microchannel device by controlling the rate of air heating. Flow rates on the order of 20 nL/s are obtained in the microchannel (300 microns x 30 microns) by heating the air chamber at the rate of approximately 6 degrees C/s. In this paper, we describe the design, fabrication, and operation of this new technique of generating on-chip air pressure, used for metering and pumping nanoliter discrete drops in microchannels.

Air Pressure↗

Monolithic capillary electrophoresis device with integrated fluorescence detector.

A monolithic capillary electrophoresis system with integrated on-chip fluorescence detector has been microfabricated on a silicon substrate. Photodiodes in the silicon substrate measure fluorescence emitted from eluting molecules. The device incorporates an on-chip thin-film interference filter that prevents excitation light from inhibiting the fluorescence detection. A transparent AZO conducting ground plane is also used to prevent the high electric fields used for the separation from interfering with the photodiode response. Separations of DNA restriction fragments have been performed in these devices with femtogram detection limits using SYBR Green I intercalating dye.

Bacteriophage phi X 174↗

Mobility, diffusion and dispersion of single-stranded DNA in sequencing gels.

Electrophoresis of single-stranded DNA in denaturing polyacrylamide gels is presently a standard procedure for the sequencing of DNA fragments. A thorough understanding of the factors that determine the resolution of DNA fractionated in polyacrylamide gels is necessary to optimize the performance of DNA sequencers. Significant research on the mobility of double-stranded (ds)DNA molecules in agarose and polyacrylamide gels has been performed, and the phenomenon of band broadening of single-stranded (ss)DNA fragments in DNA sequencing gels has received attention only recently. In this paper, we present a detailed study of mobility, diffusion and dispersion of ssDNA in sequencing gels as a function of molecular size, gel concentration and electric field strength. DNA mobility is shown to be essentially independent of electric field in the range of 0-60 V/cm. The band broadening is greatly enhanced in the presence of an electric field and the dispersion coefficient (DE) can be an order of magnitude higher than the field-free diffusion coefficient. The measured migration parameters approximately follow the predictions of the biased reptation including fluctuations (BRF) theory. However, deviations due to nonidealities of the separation conditions are observed. The measured migration parameters can be used to optimize the performance of separation systems.

Acrylic Resins↗

Nanoliter liquid metering in microchannels using hydrophobic patterns.

Nanoliter-sized liquid drops can be accurately metered inside hydrophilic microchannels using a combination of hydrophobic surface treatment and air pressure. The technique involves spontaneously filling the microchannels up to a hydrophobic region and splitting a liquid drop by injecting air through a hydrophobic side channel. The hydrophobic regions are fabricated by using a patterned metal mask on a substrate. The patterned substrate is immersed in an isooctane solution containing 1H,1H,2H,2H-per-fluorodecyltrichlorosilane to form hydrophobic patches on the exposed surface. Stripping the metal mask leaves the hydrophobic patches and restores the hydrophilic substrate surface. Precise and accurate liquid volumes, ranging from 0.5 to 125 nanoliters, have been metered using this technique. Theoretical predictions of the pressure needed to meter drops compare well with the experimental values.

Chemistry Techniques, Analytical↗

An integrated nanoliter DNA analysis device.

A device was developed that uses microfabricated fluidic channels, heaters, temperature sensors, and fluorescence detectors to analyze nanoliter-size DNA samples. The device is capable of measuring aqueous reagent and DNA-containing solutions, mixing the solutions together, amplifying or digesting the DNA to form discrete products, and separating and detecting those products. No external lenses, heaters, or mechanical pumps are necessary for complete sample processing and analysis. Because all of the components are made using conventional photolithographic production techniques, they operate as a single closed system. The components have the potential for assembly into complex, low-power, integrated analysis systems at low unit cost. The availability of portable, reliable instruments may facilitate the use of DNA analysis in applications such as rapid medical diagnostics and point-of-use agricultural testing.

Costs and Cost Analysis↗

Electrophoretic separations using sweeping fields.

Sweeping-field electrophoresis is investigated as a method for increasing the resolution of low-voltage slab gel separations. In this technique a low direct current (DC) voltage is time multiplexed to an array of periodically spaced electrodes placed along the length of the slab in a manner that follows the band migration. Because the electrode spacing is smaller than the slab length, a larger field is generated, yielding an improved separation. The effect of the nonuniform electric field on band distortion is studied in some detail. Experimental band distortion results showed good agreement with theoretical predictions in a macroscopic sweeping-field electrophoresis system. Both analytical and numerical results show that band distortion can be effectively minimized when an appropriate sweep rate is selected for a narrow band range. Using this scheme we have achieved the same number of theoretical plates as a DC-driven system with one third of the drive voltage.

Electrophoresis, Agar Gel↗

Microfabricated structures for integrated DNA analysis.

Photolithographic micromachining of silicon is a candidate technology for the construction of high-throughput DNA analysis devices. However, the development of complex silicon microfabricated systems has been hindered in part by the lack of a simple, versatile pumping method for integrating individual components. Here we describe a surface-tension-based pump able to move discrete nanoliter drops through enclosed channels using only local heating. This thermocapillary pump can accurately mix, measure, and divide drops by simple electronic control. In addition, we have constructed thermal-cycling chambers, gel electrophoresis channels, and radiolabeled DNA detectors that are compatible with the fabrication of thermocapillary pump channels. Since all of the components are made by conventional photolithographic techniques, they can be assembled into more complex integrated systems. The combination of pump and components into self-contained miniaturized devices may provide significant improvements in DNA analysis speed, portability, and cost. The potential of microfabricated systems lies in the low unit cost of silicon-based construction and in the efficient sample handling afforded by component integration.

Automation↗