Regional effects of repetition time on NMR quantitation of water in normal and edematous lungs.

It is well known that pulmonary edema is, in general, spatially nonuniform. Since the NMR spin-lattice relaxation time (T1) is increased by lung edema, the spatial distribution of T1 will be nonuniform. When the repetition time (TR) is short relative to the T1 of edematous lung, lung water content will be underestimated and this underestimation will be spatially nonuniform as well. Therefore, technical artifacts which are a complex function of lung edema and its spatial distribution are expected. We compared overall and regional (topographic) lung water density measurements obtained from living rats (with normal or edematous lungs) using repetition times of 2.0 and 6.2 s (at a magnetic field of 1 T), to quantify this uneven T1 effect for normal and edematous lungs. NMR measurements at TR = 2.0 s underestimated whole lung water density (-rho H2O) TR = 6.2 s) by an average of 7.2% in normal rats and 22.5% in rats with pulmonary edema. Regional -rho H2O underestimation (%delta-rho H2O) varied from 2.2 to 8.8% (groups means) in normal lungs and from 7.3 to 30.8% in edematous lungs. As a result, the interquartile range (of the voxel distribution as a function of rho H2O) underestimated the spatial nonuniformity of lung water density by 28.0% in edematous lungs, likely because of greater loss of NMR signal from high-water-density, long-T1 lung regions. Both %delta-rho H2O and T1 were significantly correlated with -rho H2O at TR = 6.2 s.(ABSTRACT TRUNCATED AT 250 WORDS)

Body Water↗

Resonant ac-dc magnetic fields: calculated response.

An elementary model consisting of one charged particle in a viscous medium exposed to weak ac-dc low-frequency magnetic fields is analyzed to identify and explain the fundamental characteristics of the physical mechanisms that result in a resonance response, which is similar to the familiar cyclotron resonance. The model predicts both frequency and amplitude windows, which are explained in terms of synchronization of the particle with electric fields. Although extrapolation of model results to biological systems is limited by the elementary nature of the model, the model results indicate that observed resonant responses by others of biological systems to ac-dc magnetic fields are probably not due to resonant response of ions in solution, since the model predicts that no resonant response is possible unless the viscous damping is very low, many orders of magnitude lower than the viscous damping of ions in solution.

Magnetics↗

Quantitative assessment of pulmonary edema by nuclear magnetic resonance methods.

Considerable progress has been made in the application of nuclear magnetic resonance (NMR) imaging and nonimaging techniques to the quantitative assessment of pulmonary edema. NMR measurements offer the advantages of being noninvasive, relatively rapid, and easily repeatable. In addition, NMR imaging is suitable for the determination of lung water distribution. Studies of various animal models have shown that NMR techniques can adequately detect and quantify relative changes in lung water content and distribution in various types of experimental lung injury. Preliminary observations in humans suggest that NMR measurement of relative lung water changes in clinical pulmonary edema should be feasible. Although the application of NMR to the assessment of pulmonary edema appears to be very promising, it also poses significant problems that must be solved before it can be established as a standard experimental and clinical method.

Animals↗

Assessment of lung water distribution by nuclear magnetic resonance. A new method for quantifying and monitoring experimental lung injury.

We have developed a new analytical method that uses nuclear magnetic resonance (NMR) imaging data to quantify lung water content and distribution. This new method generates a distribution of lung water density in which the fraction of voxels corresponding to a given water density is plotted on the vertical axis as a function of water density on the horizontal axis, thereby complementing the spatial information provided by the NMR image. We obtained reproducible lung water distribution data at comparable lung volumes in normal excised lungs and in intact living rats. In normal excised unperfused rat lungs, the distribution varied with the degree of inflation, but the changes were small compared with those associated with lung edema. The lung water density distribution changed markedly after induction of lung edema by intrabronchial saline instillation, intravenous oleic acid injection, and rapid intravenous saline infusion. Lung water density distribution data were well correlated (correlation coefficient = 0.948 for the excised lungs and 0.823 for the intact living rats) with gravimetric lung water measurements. The new analytical method is noninvasive, provides easily repeatable measurements, and is as sensitive as the gravimetric technique to lung water changes.

Animals↗

Determination of lung water content and distribution by nuclear magnetic resonance imaging.

NMR imaging techniques are applicable to the assessment of lung water content and distribution because the NMR signal is, under certain conditions, proportional to tissue proton density. NMR imaging is noninvasive, easily repeatable, free from ionizing radiation, and particularly suitable for the assessment of spatial lung water distribution. Lung water content and distribution have been estimated in excised animal lungs and in intact dead or living animals, under normal conditions and in various types of experimental pulmonary edema. Excised human lungs and human subjects have also been studied. Published data indicate that measurements of lung water content by NMR imaging techniques are feasible. These techniques estimate lung water spatial distribution with satisfactory accuracy and excellent resolving power. The application of NMR imaging techniques poses several problems and limitations, but available data suggest that most of the problems can be solved. NMR imaging has the potential to become a powerful tool for lung water research. Prospects of clinical application are also encouraging; numerous applications can be foreseen, although lack of mobility of NMR imaging systems may be a significant limitation in critical care medicine.

Animals↗

A new nuclear magnetic resonance property of lung.

Inflated lung has a nuclear magnetic resonance (NMR) free-induction decay (FID) which is short compared with that of collapsed lung and those of other body tissues. An almost identically short FID is obtained from a slurry of 5-micron alumina particles in water. Interfaces between air and water in lung and between alumina and water in the slurry appear to be the source of spatial internal magnetic inhomogeneities which produce NMR line broadening and the short FID. Paired images that included lung, taken with paired symmetric and asymmetric NMR spin-echo sequences, permit the generation of an image, by subtraction, of the lung isolated from surrounding tissue. These new lung images are neither proton density, T1 (spin-lattice relaxation time), nor T2 (spin-spin relaxation time) images. They complement current NMR images and provide information about regional lung inflation. This previously unrecognized NMR property of lung tissue has potential application in NMR imaging, in quantitative determination of lung water and its distribution, and in the quantitation of regional lung inflation.

Animals↗

Calculated power absorption patterns for hyperthermia applicators consisting of electric dipole arrays.

We have applied the plane-wave spectrum method to obtain a technique for calculating the internal fields in a lossy dielectric half-space irradiated by rather arbitrary sources. We used the technique to calculate power absorption profiles of some idealized aperture sources to gain insight into how the source parameters affect the power absorption profile. With this insight, we next calculated power absorption profiles of some linear electric dipole antenna arrays. From these results we developed a simpler method of optimizing the antenna parameters by calculating their field pattern in an infinite water medium, which does not require the PWS method and is therefore faster and cheaper. Using this technique, we found an antenna array with reasonably practical parameters that produces an appealing calculated power absorption profile. We also made some calculations based on a simple approximate model that indicate that a three-element dipole array on the front of a patient and a similar one on the back could produce deep central heating. Although our calculations are based on a somewhat crude dielectric half-space model of the body, the results provide valuable insight about power absorption profiles and indicate that practical systems for producing deep internal heating without overheating the surface of the body could be developed.

Absorption↗

Determination of lung water content and distribution by nuclear magnetic resonance.

The present study was designed to determine the value of nuclear magnetic resonance (NMR) imaging as a technique for quantifying lung water distribution and to estimate the degree of spatial resolution achieved by this technique. The spatial distribution of water was determined in six small (0.76 ml) rat lung tissue specimens by an NMR line-scan technique. After NMR imaging, each lung specimen was frozen and subdivided into slices; the gravimetric lung water content for each lung slice was compared with the integrated NMR water content over the volume corresponding to the same lung slice. In each tissue specimen, NMR and gravimetric lung water values were significantly correlated; the correlation coefficient for the pooled data for all six lung specimens was 0.91 (P less than 0.01). In two lung specimens, NMR values tended to be slightly higher than the gravimetric values. The magnitude of the difference between NMR and gravimetric values was generally less than 20% and only occasionally exceeded 25%. Our results suggest that the NMR-imaging method provides satisfactory estimates of lung water content and its distribution; the resolving power of the technique is excellent, as shown by its ability to detect water content differences between lung tissue slices of volume as small as 0.076 ml.

Animals↗

Power deposition patterns in magnetically-induced hyperthermia: a two-dimensional low-frequency numerical analysis.

The electric fields and power deposition patterns generated in two-dimensional inhomogenous models exposed to the axially directed uniform magnetic fields of an infinitely long solenoid are calculated numerically. The fields are calculated using the method of moments (Galerkin procedure) with linear basis and weighting functions. This low-frequency analysis is useful for studying the power deposition patterns attributable to solenoidal inductive applicators operated at frequencies up to 13.56 MHz. For the models we have studied, the ratio of power per volume deposited into the tumor to power per volume deposited into the immediately surrounding tissue is largest for tumors in the lung, although the power per volume deposited into the outermost layer is still much larger than the power per volume deposited into the tumor; it may be possible, however, to cool this region adequately from the body surface. When the complex permittivity of the tumor model is similar to that of the region in which it is embedded, the currents in the torso and tumor circulate primarily around the center of the body, as has been previously calculated for concentric cylinders. When the complex permittivity of the tumor is much greater than the region in which it is embedded, the currents in the tumor circulate primarily around the center of the tumor.

Diathermy↗

Microwave methods of measuring changes in lung water.

Two microwave methods for measuring changes in lung water content have been investigated. The first is based on measuring changes in the phase of an active microwave signal transmitted through the thorax, while the other is based on measuring the natural microwave radiation emitted by the body with a radiometer. The feasibility of using the active microwave method is investigated by making measurements on phantoms, on anesthetized dogs with induced pulmonary edema, and on isolated dog lungs. The obtained results clearly illustrated that the method is sensitive enough to measure small changes in lung water content. In the radiometer method, on the other hand, both calculations and preliminary measurements in phantoms indicate that the natural microwave emission changes with lung water content and that conventional radiometry systems should be able to detect as little as three to four percent change in lung water content. Initial results from both methods, therefore, indicate the soundness of the basic ideas and justify further development of these methods for clinical use.

Adult↗

Mechanical and gas-distribution behavior of a collateral ventilation model.

We extended the theoretical analysis of Otis et al. (J. Appl. Physiol. 8: 427-443, 1956) to study the effects of collateral ventilation on lung mechanics and gas distribution. Equations were developed to express the effective compliance, the effective resistance, and the distribution of airflow and tidal volume in a two-compartment model incorporating a collateral communication. The analysis of the model showed that, in general, collateral ventilation tends to attenuate the degree of frequency dependence of compliance and resistance, the magnitude of this effect being dependent on the mechanical properties of the model, including collateral resistance. The influence of collateral ventilation is important when the model simulates the mechanical characteristics of the emphysematous lung (marked time-constant inequality with regionally high airway resistance, and relatively low collateral resistance). Under these conditions, a large fraction of the tidal volume of the high airway resistance lung compartment is contributed by the collateral communication. The effects of collateral ventilation on the mechanical behavior of the model are negligible when collateral resistance largely exceeds airway resistance (simulating experimental findings in normal lungs). The present theoretical data suggest that the use of equations based on a model incorporating collateral ventilation is justified, at least in predicting the mechanical and gas-distribution behavior of the lung in emphysema.

Animals↗

Lung water quantitation by nuclear magnetic resonance imaging.

Nuclear magnetic resonance imaging was used to determine quantitatively the water distribution of saline-filled and normal rat lungs in both isolated lung and in situ preparations. Regional lung edema was easily detected. Studies of an isolated lung fragment indicate an accuracy of better than 1 percent and images of H2O/D2O phantoms indicate an average error of 2.7 percent.

Animals↗

Postresonance electromagnetic absorption by man and animals.

A surface integral equation (SIE) method is used to calculate the specific absorption rate (SAR) in spherically capped cylindrical models irradiated by an axially incident electromagnetic plane wave (K polarization) in a frequency range for which calculations previously have not been available (80-400 MHz for man models). In the SIE method, the electromagnetic (EM) field relations are formulated in terms of electric and magnetic currents on the surface of the model. The average SAR is calculated from the far scattered EM fields by means of the forward scattering theorem. SAR data calculated by the SIE method agree with data calculated by the extended boundary condition method (EBCM) for frequencies up to 80 MHz (the upper frequency limit of the EBCM) for man models. For rat models exposed to 1-3 GHz radiation, reasonable agreement was also obtained with the limited experimental data available.

Animals↗