Search PubMed⌕ Search

Biomedical subjects

C G Orton

Publications and source records attributed to C G Orton.

At least 37 records · Page 2Linked to original sources

A unified approach to dose-effect relationships in radiotherapy. I: Modified TDF and linear quadratic equations.

A linear quadratic factor analogue (LQF) to the variable-exponent TDF model is introduced. In both of these models, account is taken of the volume of tissue irradiated. Scaling factors are used such that an LQF or a TDF of 100 represents tolerance for each volume or partial volume of each tissue or organ irradiated. These models are sufficient for tissues which are irradiated fairly homogeneously. Examples illustrate the use of these models.

Computer Simulation↗

A unified approach to dose-effect relationships in radiotherapy. II: Inhomogeneous dose distributions.

Conventional dose-effect relationships, such as those based upon the NSD or linear-quadratic concepts, do not account for dose inhomogeneities. Only a single "dose" value can be used in these equations and this can give rise to significant errors in the estimation of the "tolerance" dose in situations where dose distributions are inhomogeneous. This paper presents a method of "integrating" the biologically effective dose over the entire volume of each organ or tissue irradiated. Integral forms of the variable-exponent TDF and linear quadratic factor (LQF) models (ITDF and ILQF, respectively) can be used to determine whether or not any organ or tissue in an irradiated volume has exceeded tolerance, regardless of dose distribution non-uniformity. Several examples are given with comparisons to solutions obtained by conventional dose-effect models.

Computer Simulation↗

Dose dependence of complication rates in cervix cancer radiotherapy.

The population selected for this study was a group of 410 Stage IIB and III squamous cell Ca cervix patients treated at the Radiumhemmet between the years 1958-1966. A total of 48 of these patients developed moderate-to-severe rectal and/or bladder complications. Of these, 33 were evaluable with respect to dose-dependence of complications, that is, complete intracavitary dose measurements and external beam dose calculations, no chemotherapy or electrocautery, and complete clinical radiotherapy records. A group of 57 randomly selected uninjured patients were used as controls. Results show good correlation between dose, expressed in TDF units, and complication rates for both rectal and bladder injuries. Severity of rectal injury was observed to increase with increase in dose, although no such correlation was observed for bladder injuries. Mean delays in the expression of symptoms of injury were 10 months for the rectum and 22 months for the bladder.

Carcinoma, Squamous Cell↗

Transmission blocks: clinical and biological rationales.

This paper describes the clinical and biological rationales for the use of transmission blocks. Clinical advantages over the use of full-thickness blocks applied part way through the course of therapy include the use of only one set of fields, blocks, and beam calculations, and less complex chart recording. There is a net saving in time required for the preparation and treatment of the patient. There is also a quality assurance advantage since the impact of a potential error in block positioning is reduced. In terms of biological advantages, it is demonstrated that the linear-quadratic iso-effect model can be applied to predict an improvement of up to 10% in the therapeutic ratio if transmission blocks are used instead of full-thickness blocks.

Abdomen↗

Lung corrections in photon beam treatment planning: are we ready?

This paper reviews reasons cited for and against the use of lung corrections. It is suggested that all the reasons cited for not making corrections are no longer viable. A phantom has been designed to simulate the thorax region of a patient at both CT and radiotherapy radiation energies. With this phantom, lung correction factors for the calculation of tumor dose have been measured for a typical lung cancer treatment regimen, and these results are shown to compare favorably with correction factors computed by all the commonly employed correction algorithms. Some algorithms are better than others, and one of the best is the readily hand-calculable generalized power-law TAR method. It is shown that failure to correct for lung transmission can severely limit the integrity of many interinstitutional studies, especially cooperative clinical trials. It is concluded that lung corrections for the calculation of tumor doses in the thorax region should be gradually introduced over the next several years.

Humans↗

SI units of TDF.

Explore the source record for details and available documents.

International System of Units↗

Contrast enhancement of high-energy radiotherapy films.

An order-of-magnitude improvment in the contrast of high-energy localization and verification films has been achieved through the application of a simple, inexpensive, contrast enhancement technique. The method involves making reversal contact "prints" of the original film onto ordinary X-ray fi-m with equipment commonly available in any radiotherapy department. This results in "gamma multiplication". The theory as well as several applications of this effect are presented.

Humans↗

Errors in applying the NSD concept.

An analysis of selected papers in which the Nominal Standard Dose (NSD) concept is used reveals that about 50% of them contain errors. These mistakes are both conceptual and mathematical in nature and average plus or minus 7%. Typical errors and methods to eliminate them are discussed. A table is provided for interconversion of NSDs, partial tolerances, and time, dose and fractionation (TDF) factors.

Humans↗