Search PubMed⌕ Search

Biomedical subjects

C G Niël

Publications and source records attributed to C G Niël.

4 recordsLinked to original sources

Measuring radiation fibrosis: the interobserver reliability of two methods of determining the degree of radiation fibrosis.

PURPOSE: To compare the interobserver reliability of the palpation method with the method of measuring tissue compliance with a tissue compliance meter (TCM) on women who underwent breast-conserving surgery and radiotherapy for breast cancer. METHODS AND MATERIALS: Thirty-eight patients and 30 controls were measured with the palpation method by two radiation oncologists and with the TCM by two physiotherapists. Measurements were taken on four locations of the breasts of all 68 women. Reliability coefficients were computed for both methods. A weighted kappa score was computed for the palpation method and this was compared with the intraclass correlation coefficient (ICC) computed for the TCM method. The conditions for direct comparison of these scores were met in this study. RESULTS: A weighted kappa of 0.65 was computed for the palpation method and an ICC of 0.91 was computed for the TCM method. These scores differ significantly from each other (p < 0.01). CONCLUSION: The interobserver reliability of the TCM method is superior to that of the palpation method. However, at locations where the TCM is not applicable, palpation is a good alternative.

Adult↗

Simulation accuracy in radiotherapy for maxillary sinus tumors.

PURPOSE: To evaluate the accuracy and clinical importance of beam positioning during simulation of radiation treatment for tumors in the maxillary sinus. METHODS AND MATERIALS: Five patients were prepared as if they were to be treated for a maxillary sinus tumor. A three-beam computed tomography (CT) scan-based computer plan was made for each patient. The location of the central beam axis of each beam was measured, relative to bony anatomical structures. A simulation was performed using the bony references to position the radiation beams during simulation. After this, the simulation procedure was repeated by the use of a noninvasive external localization frame with a known accuracy and reproducibility within 2 mm margins. RESULTS: When defining the clinical target volume as the known tumor with a 1 cm margin, three out of five patients would suffer a partial geographical miss throughout the entire radiation treatment due to erroneous beam positioning at the simulation stage when using bony structures as a guide for beam positioning. The influence of these errors is analyzed as normal tissue complication and tumor control probabilities. CONCLUSION: When defining a planning target volume, one should consider a margin to correct for possible simulation errors. We advise the use of objective, external (and thus nonanatomical) landmarks as a reference during simulation to reduce this extra margin to a minimum. In case of simulation, using bony structures as a reference, an additional margin should be entered, depending on the simulation accuracy that can be obtained.

Humans↗

Optimizing brachytherapy for locally advanced cervical cancer.

PURPOSE: No adequate high dose rate brachytherapy technique exists to cover all known tumor volume by using one type of applicator in patients presenting with a cervix carcinoma extending to the vaginal wall and the parametria. METHODS AND MATERIALS: We adapted the existing high dose rate applicator, existing of two ovoids and one intrauterine tube, to achieve adequate irradiation of the uterus, the parametria, and the vaginal wall in these patients. Using the optimization program of the Nucletron Planning System, isodose curves were obtained to apply a specified dose of 8.5 Gy at point A and at 5 mm depth of the vaginal wall by using a single applicator for both fractions. RESULTS: Fractionated high dose rate brachytherapy can be given with both higher dosimetric accuracy and more adequate irradiation of the vaginal and the parametrial tumor component after adapting the existing high dose rate applicator for brachytherapy in cervical cancer.

Brachytherapy↗

Optimization of interstitial volume implants.

For interstitial applications of high dose rate (HDR) afterloading brachytherapy, generally a single stepping iridium-192 source is used, enabling optimization of the dose distribution by optimization of the relative time (dwell time) that the source remains at a certain position (dwell position). We analysed the effects of geometric optimization in a regular volume implant, with strictly parallel catheters, and in an irregular volume implant, such as an implant for tumours of the base of the tongue characterized by a non-parallel geometry and varying catheter separations. In both examples the reference dose is specified at 85% of the mean central dose (as is done in the Paris system for dose specification) in the non-optimized as well as the optimized plan. The irradiated volume, the dose uniformity, and the choice of the reference dose of optimized and non-optimized dose distributions were compared. This was done by isodose plots for representative planes, volume dose histograms (distributed, contiguous, and natural), and dose non-uniformity ratios (DNRs). For the regular implant, optimization results in a 28% increase in the treated volume with a similar increase in the overdosed volumes. In order to keep the treated volume comparable with the non-optimized dose distribution, 90-95% of the mean central dose should be chosen as a reference dose or the range of active dwell positions should be shortened in case of optimization. In the case of the irregular volume implant at the base of the tongue, the method for dose specification should be kept unchanged after geometric optimization as the volume enclosed by the reference isodose does not increase. It is clear from the volume-dose histograms that there is a reduction of the overdosed volume due to optimization. This is accompanied by an increase in the uniformity index and a decrease of the DNR. In conclusion, geometric optimization appears to be an effective tool to improve the dose distribution of interstitial volume implants. Contiguous and natural volume dose histograms appear, apart from planar dose plots, valuable methods for evaluating the dose distribution of an implant.

Brachytherapy↗