Search PubMed⌕ Search

Biomedical subjects

C Fink

Publications and source records attributed to C Fink.

At least 37 records · Page 2Linked to original sources

Preoperative evaluation of living renal donors: value of contrast-enhanced 3D magnetic resonance angiography and comparison of three rendering algorithms.

The aim of this study was to assess the value of contrast-enhanced three-dimensional MR angiography (CE 3D MRA) in the preoperative assessment of potential living renal donors, and to compare the accuracy for the depiction of the vascular anatomy using three different rendering algorithms. Twenty-three potential living renal donors were examined with CE 3D MRA (TE/TR=1.3 ms/3.7 ms, field of view 260-320x350 mm, 384-448x512 matrix, slab thickness 9.4 cm, 72 partitions, section thickness 1.3 mm, scan time 24 s, 0.1 mmol/kg body weight gadobenate dimeglumine). Magnetic resonance angiography data sets were processed with maximum intensity projection (MIP), volume rendering (VR), and shaded-surface display (SSD) algorithms. The image analysis was performed independently by three MR-experienced radiologists recording the number of renal arteries, the presence of early branching or vascular pathology. The combination of digital subtraction angiography (DSA) and intraoperative findings served as the gold standard for the image analysis. In total, 52 renal arteries were correspondingly observed in 23 patients at DSA and surgery. Other findings were 3 cases of early branching of the renal arteries, 4 cases of arterial stenosis and 1 case of bilateral fibromuscular dysplasia. With MRA source data all 52 renal arteries were correctly identified by all readers, compared with 51 (98.1%), 51-52 (98.1-100%) and 49-50 renal arteries (94.2-96.2%) with the MIP, VR and SSD projections, respectively. Similarly, the sensitivity, specificity and accuracy was highest with the MRA source data followed by MIP, VR and SSD. Time requirements were lowest for the MIP reconstructions and highest for the VR reconstructions. Contrast-enhanced 3D MRA is a reliable, non-invasive tool for the preoperative evaluation of potential living renal donors. Maximum intensity projection is favourable for the processing of 3D MRA data, as it has minimal time and computational requirements, while having similar or superior accuracy for the depiction of vessel anomalies or pathology compared with VR and SSD, respectively.

Algorithms↗

Evaluation of neoadjuvant chemotherapeutic response of breast cancer using dynamic MRI with high temporal resolution.

The aim of this study was to evaluate changes in both size and contrast enhancement of breast tumors during neoadjuvant chemotherapy, using dynamic MRI with high temporal resolution. Patients with advanced breast cancer (n=21) underwent a 1.5-T MRI scan prior to and following neoadjuvant chemotherapy with four cycles. Dynamic contrast enhancement was measured using a fast turbo-FLASH sequence and quantified using a two-compartment model with the parameters k(ep) and amplitude. Image analysis was done on images overlayed with a color map of parameters. The correlation between tumor diameter measured by histopathology and MRI was 0.7 (p<0.003). A reduction of tumor size after chemotherapy of more than 25% was associated with a decrease of both analyzed contrast enhancement parameters (k(ep): p<0.002; amplitude: p<0.006), where k(ep) began to drop already after the first cycle of chemotherapy (p<0.008). A clear reduction of tumor size was only noted after the third cycle (p<0.008). In patients without tumor regression there was also a trend towards an early reduction of contrast enhancement. We assume that MRI with high temporal resolution and color mapping is a novel tool to assess therapeutic effects of neoadjuvant chemotherapy in breast tumors, which deserves further prospective evaluation.

Antineoplastic Combined Chemotherapy Protocols↗

Precision and accuracy of a transportable dual-energy X-ray absorptiometry unit for bone mineral measurements in guinea pigs.

Dual energy X-ray absorptiometry (DXA) is a valuable tool for measuring bone mineral content (BMC) and bone mineral density (BMD) in small-animal research. The present study was devised to establish guidelines and to define sites for bone mineral measurements in guinea pigs and to evaluate the accuracy of a new transportable research DXA unit. Repeated scans were performed on 30 guinea pig hindlimbs (in situ) as well as the isolated bones from these limbs (ex situ). Nine exactly specified regions of interest (ROIs) were analyzed twice for BMC and BMD by three different observers. Additionally, the BMC of whole bones and bone segments as measured by DXA was correlated to ash weights of bone in a subset of five animals to determine the accuracy of the DXA measurements. On ex situ scans, intra-observer variability for BMD ranged from 0.09% to 2.33% and inter-observer variability from 0.23% to 5.86% depending on the site studied, with smaller ROIs exhibiting more variability. Coefficients of variance (CV) for BMC measurements were slightly higher than for BMD. However, BMC offered a better correlation between in situ and ex situ values than BMD. On in situ scans, observer variability for BMD and BMC for comparable sites was higher than the ex situ variability. The results of this study indicate that DXA provides an accurate measurement of BMC even in small specimens. The precision of BMC and BMD measurements in situ can be improved considerably by using specific, well-defined ROIs and by careful placement of the bones to be scanned in close proximity to the scanning surface.

Absorptiometry, Photon↗

[Modern CT diagnosis of acute thoracic and abdominal trauma].

PURPOSE: To evaluate a modified algorithm in the diagnostic management of polytraumatized patients by using whole body multislice CT (MSCT) as primary diagnostic tool. MATERIAL AND METHODS: Between June 1999 and October 2000 532 polytraumatized patients were referred to the emergency department. 336 polytraumatized patients were primarily evaluated using whole body MSCT according to the "Innsbruck Emergency Algorithm". MSCT is performed immediately after cardiovascular stabilization of the patient. During the initial stabilization period free intraabdominal fluid is excluded or demonstrated by abdominal ultrasound. Time-consuming conventional radiographs are omitted with exception of an optional chest X-ray. In patients with suspected or obvious arterial injuries or fractures the multislice-CT-dataset is used to perform 2D and 3D reconstructions in order to optimize visualization of additional skeletal and vascular injuries. RESULTS: By means of whole body MSCT it was possible to detect all injuries. The diagnostic advantage of whole body MSCT as compared to conventional X-ray was analyzed in 111 consecutive polytraumatized patients with an injury severity score (ISS) of 34.77. The early use of MSCT shortened the time for diagnostic work-up substantially (approximately 50%). CONCLUSION: Whole body multislice-CT used as primary diagnostic tool in the management of polytraumatized patients allows for a fast, accurate and comprehensive diagnostic work-up.

Abdominal Injuries↗

[Computer-assisted drilling of the lower extremity. Technique and indications].

Computer assisted navigation-based surgery is a novel and interesting challenge for todays surgeons. One must however keep in mind, that the indications for these techniques (a) should be carefully considered, (b) used only if morbidity is not increased and (c) when previously problematic or inacurate surgical methods can be improved upon. This study reports that, using a non-invasive fixation method (FISCOFIX-Cast), lesions between the ankle- and knee-joints can be precisely localized, registered and treated. Due to the difficult access to lesions especially in the posterior areas of the talus, using conventional arthroscopic methods this procedure is very useful. Percutaneous retrograde drilling (cf. [6, 7, 9, 15, 20, 21]) spared the joint's cartilage in all cases. At the level of the knee joint we see the usefulness of this method for complex situations (cf. [12, 13]) requiring precise drilling.

Anterior Cruciate Ligament↗

[Modern CT diagnosis of acute thoracic and abdominal trauma].

PURPOSE: To evaluate a modified algorithm in the diagnostic management of polytraumatized patients by using whole body multislice CT (MSCT) as primary diagnostic tool. MATERIAL AND METHODS: Between June 1999 and October 2000 532 polytraumatized patients were referred to the emergency department. 336 polytraumatized patients were primarily evaluated using whole body MSCT according to the "Innsbruck Emergency Algorithm." MSCT is performed immediately after cardiovascular stabilization of the patient. During the initial stabilization period free intraabdominal fluid is excluded or demonstrated by abdominal ultrasound. Time-consuming conventional radiographs are omitted with exception of an optimal chest X-ray. In patients with suspected or obvious arterial injuries or fractures the multislice-CT-dataset is used to perform 2D and 3D reconstructions in order to optimize visualization of additional skeletal and vascular injuries. RESULTS: By means of whole body MSCT it was possible to detect all injuries. The diagnostic advantage of whole body MSCT as compared to conventional X-ray was analyzed in 111 consecutive polytraumatized patients with an injury severity score (ISS) of 34.77. The early use of MSCT shortened the time for diagnostic work-up substantially (approximately 50%). CONCLUSION: Whole body multislice-CT used as primary diagnostic tool in the management of polytraumatized patients allows for a fast, accurate and comprehensive diagnostic work-up.

Abdominal Injuries↗

[Transcatheter closure of atrial septal defects with the CardioSEAL occluder].

Data on mid- and long-term follow-up for the recent devices for closure of secundum-type atrial septal defects are limited. The purpose of our retrospective study was to report the effectiveness of transcatheter closure in patients with various morphological types of atrial septal defect other than centrally located defects within the oval fossa using the CardioSEAL and CardioSEAL-Starflex occluder. A total of 91 patients (age 1.5-71 years, median 6 years) underwent transcatheter closure. On the transesophageal echocardiogram, defect size varied from 6 to 18 mm with an estimated stretched diameter of 11 to 24 mm, median 15 mm; the ratio of the stretched diameter to septal length ranged from 0.28 to 0.68. Mean follow-up was 28.7 +/- 11,9 months (range 3-46 months). Isolated secundum-type defects were present in 59 patients (65%), multiple septal defects including patients with perforated atrial septal aneurysms and defects with deficient atrial rim in 32 patients (35%). Occlusion rate using device diameters from 23 to 40 mm increased from 66% (60/91 patients) immediately after implantation to 86% (48/56 patients) 24 months after implantation. Patients with isolated secundum-type defects presented with a significantly higher primary closure rate (45/59 patients, 76%) compared to patients with various defect morphology. Closure rate did not depend on the type of implanted device modification. No thrombus formation, sustained atrial arrhythmia or infective endocarditis occurred. Serial transthoracic echocardiographic findings revealed protrusion of one left-sided arm onto the right atrial aspect in 5 patients; malposition of one right-sided superior arm of the device was observed in 7 patients. Fluoroscopy showed single fatigue fracture in 7 patients (7.7%) within the first 6 months after implantation. These results demonstrate that transcatheter closure with the double umbrella device was effective and safe on medium-term follow-up and could be extended to atrial septal defects of various morphology.

Adolescent↗

Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector.

AIM: The aim of this study was to evaluate the image quality and the potential for radiation dose reduction with a digital flat-panel amorphous silicon detector radiography system. MATERIAL AND METHODS: Using flat-panel technology, radiographs of an anthropomorphic thorax phantom were taken with a range of technical parameters (125kV, 200mA and 5, 4, 3.2, 2, 1, 0.5, and 0.25mAs) which were equivalent to a radiation dose of 332, 263, 209, 127, 58.7, 29, and 14 microGy, respectively. These images were compared to radiographs obtained by a conventional film-screen radiography system at 125kV, 200mA and 5mAs (equivalent to 252 microGy) which served as reference. Three observers evaluated independently the visibility of simulated rounded lesions and anatomical structures, comparing printed films from the flat-panel amorphous silicon detector and conventional x-ray system films. RESULTS: With flat-panel technology, the visibility of rounded lesions and normal anatomical structures at 5, 4, and 3.2mAs was superior compared to the conventional film-screen radiography system. (P< or =0.0001). At 2mAs, improvement was only marginal (P=0.19). At 1.0, 0.5 and 0.25mAs, the visibility of simulated rounded lesions was worse (P< or =0.004). Comparing fine lung parenchymal structures, the flat-panel amorphous silicon detector showed improvement for all exposure levels down to 2mAs and equality at 1mAs. CONCLUSION: Compared to a conventional x-ray film system, the flat-panel amorphous silicon detector demonstrated improved image quality and the possibility for a reduction of the radiation dose by 50% without loss in image quality.

Humans↗

Induction of cyclooxygenase-2 by mechanical stress through a nitric oxide-regulated pathway.

OBJECTIVE: Biomechanical signals play important roles in regulating the homeostasis of articular cartilage, but under abnormal conditions may be a critical factor in the onset and progression of arthritis. Prostaglandin E(2) (PGE(2)) and nitric oxide (NO), derived from the enzymes cyclo-oxygenase 2 (COX2) and NO synthase 2 (NOS2), are inflammatory mediators that modulate numerous physiological and pathophysiological processes and are potentially important pharmacological targets in osteoarthritis. The goal of this study was to determine the effect of mechanical compression on PGE(2) production in the presence of selective NOS2 and COX2 inhibitors. METHODS: Articular cartilage explants harvested from 2-3-year-old pigs were subjected to intermittent compression at 0.5Hz over a range of stress magnitudes. PGE(2) and NO production into the media were determined in the presence and absence of the NOS2 inhibitor 1400W or the COX2 inhibitor NS398. COX2 protein levels were determined by immunoblot analysis. RESULTS: Mechanical compression significantly increased NO and PGE(2) synthesis in a manner that was dependent on the magnitude of stress. The selective COX2 inhibitor blocked compression-induced NO and PGE(2) production. Compression in the presence of 1400W further increased COX2 expression resulting in a 10-fold increase in PGE(2) production compared to uncompressed explants with 1400W and a 40-fold increase in PGE(2) compared to uncompressed explants without 1400W. CONCLUSION: Mechanical compression of articular cartilage increased COX2 and PGE(2) production through a NO-dependent pathway, and therefore pharmacological agents that target the NOS2 pathway in cartilage may have a significant influence on prostanoid production in the joint.

Animals↗

Magnetic resonance imaging of nude mice with heterotransplanted high-grade squamous cell carcinomas: use of a low-loaded, covalently bound Gd-Hsa conjugate as contrast agent with high tumor affinity.

RATIONALE: Malignant tumors often show an increased uptake and metabolism of plasma proteins, especially albumin. OBJECTIVES: Determine whether the accumulation of low loaded Gd-albumin improves visualization of malignant tumors by MRI. METHODS: Twelve nude mice with heterotransplanted squamous cell carcinomas were studied. The signal intensity of tumor, blood, liver, kidney and muscle tissue was studied in MR images after application of Gd-albumin during a period of 144 hours. MRI results were histologically correlated after simultaneously injection of Gd- and fluorescein-labeled albumins in 9 nude mice. RESULTS: Although liver and kidney had a maximum increase in signal intensity within 30 minutes, tumors showed a delayed 51% increase in the 24 hours after application. Histologic and fluorescence evaluation demonstrated albumin localization in tumors predominantly in stroma and necroses. CONCLUSIONS: Gd-albumin is efficiently accumulated in SCC transplants. MRI with low loaded Gd-albumin may offer relevant opportunities for recognizing tumors sensitive to a therapy with cyostic drug-labeled albumins.

Albumins↗

Diaminoindanes as microsomal triglyceride transfer protein inhibitors.

The synthesis and biological activities of biarylamide-substituted diaminoindanes as microsomal triglyceride transfer protein (MTP) inhibitors are described. One of the more potent compounds, 8aR, inhibited both the secretion of apoB from Hep G2 cells and the MTP-mediated transfer of triglycerides between synthetic acceptor and donor liposomes with IC(50) values of 0.7 and 70 nM, respectively. In normolipidemic rats and dogs, oral administration of 8aR dose-dependently reduced both plasma triglycerides and total cholesterol. Moreover, in rats and dogs, 8aR also prevented the postprandial rise in plasma triglycerides following a bolus administration of a fat load. Because MTP inhibitors decrease very low density lipoprotein assembly in the liver, the potential for hepatic lipid accumulation was evaluated. In normolipidemic rats, hepatic cholesterol and triglyceride contents were dose-dependently increased by 8aR. However, hepatic lipid accumulation resulted in negligible change in total liver weight and was reversible after withdrawal of the compound.

Animals↗

Interleukin-1, tumor necrosis factor alpha, and interleukin-17 synergistically up-regulate nitric oxide and prostaglandin E2 production in explants of human osteoarthritic knee menisci.

OBJECTIVE: In osteoarthritis (OA), a combination of biochemical and biomechanical factors may damage both menisci and articular cartilage. Nitric oxide (NO) and prostaglandin E2 (PGE2) have been implicated as mediators of inflammation in OA. The goals of this study were to determine if menisci from patients with OA produce NO and PGE2, and if the proinflammatory cytokines interleukin-1beta (IL-1beta), tumor necrosis factor a (TNFalpha), and IL-17 augment NO and PGE2 production by these tissues. METHODS: Menisci were obtained from 17 patients (age 47-75 years) undergoing total knee replacement for OA. Tissue explants were cultured alone or with IL-1beta, IL-17, or TNFalpha, and the release of NO and PGE2 from the tissue as well as the presence of type 2 nitric oxide synthase (NOS2) and cyclooxygenase 2 (COX-2) antigens were measured. RESULTS: All menisci constitutively produced NO, and significant increases in NO production were observed in the presence of IL-1beta, TNFalpha, or IL-17 (P < 0.05). The combination of IL-17 and TNFalpha significantly increased NO production compared with either cytokine alone. Basal and cytokine-stimulated NO synthesis was inhibited by the NOS inhibitors NG-monomethyl-L-arginine or N-3-aminoethylbenzylacetamidine (1400W). IL-1beta significantly increased PGE2 production. The combination of IL-1beta and TNFalpha had an additive effect on PGE2 production, while addition of IL-17 to TNFalpha or IL-1beta synergistically enhanced PGE2 production. Inhibition of NO production by 1400W significantly increased IL-1beta-stimulated PGE2 production, and inhibition of PGE2 production by the COX-2 inhibitor N-[2-(cyclohexyloxy)-4-nitrophenyl]-methanesulfonamide significantly increased IL-17-stimulated NO production. CONCLUSION: Menisci from humans with OA spontaneously produced NO and PGE2 in a manner that was synergistically or additively augmented by cytokines. NO and PGE2 exhibited reciprocal regulatory effects on one another, suggesting that pharmaceutical agents designed to inhibit NOS2 or COX-2 production may in fact be influencing both pathways.

Aged↗

[Recurrence of cystic adventitial degeneration of the popliteal artery--magnetic resonance tomography and MR angiography].

Adventitial cystic disease is a rare disorder characterized by mucin-containing cysts of the adventitial tissue. The condition has a predilection for the popliteal artery. Men are predominantly affected, usually around the fourth decade. We report of a case of recurrent adventitial cystic disease and the possibilities of modern cross-sectional imaging. In particular we discuss the advantages of magnetic resonance imaging and magnetic resonance angiography for the diagnosis of this condition. Furthermore, the etiology and the possibilities of surgical treatment are illustrated.

Arterial Occlusive Diseases↗

[Computer-assisted retrograde drilling of osteochondral lesions of the talus].

Treatment principles of osteochondral lesions of the talus usually consist of debridement of the chondral part and methods that attempt to stimulate revascularization of the necrotic bony part of the lesion. The latter is mostly achieved through multiple drilling of the subchondral zone. Dorsomedial talar dome lesions are frequently inaccessible with antegrade drilling techniques. In addition, if the cartilage surface over the bony lesion is still intact, it can be injured by antegrade drilling. To overcome these potential problems, retrograde drilling techniques have been developed using drill guides or intraoperative fluoroscopy. Our proposed method of computer-assisted retrograde drilling is an advancement of these techniques. The use of 3D navigation provides the possibility for placing a guide wire exactly in the center of the lesion defined on preoperative MRI or CT scans. This guide wire can then be overreamed with cannulated reamers followed by retrograde bone grafting of the lesion or allows multiple retrograde drilling of the subchondral plate using a parallel drill guide. We found that computer-assisted retrograde drilling could improve precision, avoid misplacement of guide wires, and reduce the time of surgery and intraoperative fluoroscopy.

Arthroscopy↗

[A new combined surgical interventional method for univentricular palliation of congenital heart defects].

UNLABELLED: Total cavo-pulmonary anastomosis is frequently performed to palliate patients with a broad variety of congenital heart defects with functionally univentricular hearts precluding biventricular circulation. In patients with risk factors for primary repair a stepwise approach is frequently chosen with initial creation of an aorto-pulmonary shunt followed by a Glenn anastomosis or hemifontan procedure. Finally a total cavo-pulmonary connection is completed surgically. The aim of this feasibility study was to develop a combined surgical-interventional approach for creation of a total cavo-pulmonary anastomosis which reduces the number of surgical interventions, precludes extracorporeal circulation and intracardiac sutures, putting the patients at risk for subsequent rhythm disturbances. METHODS: A Glenn anastomosis was created in 10 sheep without cardio-pulmonary bypass. The superior vena cava was banded superior to the cavo-atrial junction leaving a minimal lumen for subsequent interventional balloon dilatation and implantation of a stent graft. A 15 mm Gore-Tex tube was sutured around the inferior vena cava intrapericardially to provide resistance for subsequent interventional stent implantation. Total cavo-pulmonary anastomosis was completed interventionally by dilating the banded vena cava superior and connection of the inferior vena cava to the superior vena cava by implanting an Aneurx covered stent graft. RESULTS: All animals survived the combined surgical-interventional procedure. Stent deployment was possible without causing obstruction to the hepatic veins. Neither stent dislocation nor rhythm disturbances were encountered. CONCLUSIONS: Total cavo-pulmonary anastomosis can be achieved without intracardiac sutures and cardio-pulmonary bypass by use of a combined surgical-interventional approach using the Aneurx covered stent graft.

Animals↗