Search PubMed⌕ Search

Biomedical subjects

C F Hildebolt

Publications and source records attributed to C F Hildebolt.

At least 19 recordsLinked to original sources

A precise receptor-positioning device for subtraction radiography, based on cross-arch stabilization.

OBJECTIVES: To devise and test for reproducibility a new patient-beam alignment device for subtraction radiography. METHODS: A rigid, cross-arch bar was used with bite-registration material. A modified Rinn XCP rod and ring were firmly attached to the bar and were placed in contact with the X-ray cone. The receptor was held by a slot in the bar. Duplicate sets (n=8 pairs) of digital radiographs were made with a modified, calibrated DenOptix photostimulable phosphor system. Image pairs were registered and compared for geometrical and intensity errors by means of quantitative subtraction radiography. The reproducibility of patient-beam alignment for each pair was determined by measuring spatial errors at alveolar crest edges and by comparing magnifications. Intensity errors measured at two predetermined regions of alveolar bone were used to estimate corresponding bone-mass errors. RESULTS: Misalignment at the alveolar crest was generally <1 pixel (0.085 mm), and everywhere < or =0.25 mm. The magnification was constant within a relative standard deviation of 0.13% (n=8). Trabecular features were generally invisible or barely visible in subtraction images. The standard deviation of intensity errors was 1.07% (n=16). This corresponds to a change in bone mass of approximately 2% or less. CONCLUSION: The device has potential for clinical population studies in which the goal is to detect small changes in bone mass and alveolar-crest height. It is convenient to use and comfortable for patients. Because of the cross-arch design, patient-beam alignment is expected to be relatively insensitive to bite-registration errors, tooth movement, and tooth loss.

Alveolar Process↗

An overview of radiographic film holders.

OBJECTIVES: To provide an overview of radiographic film holders, from their inception in the early 1900s to present day. METHODS: A Medline literature search was conducted for dental studies that used keywords that pertain to radiographic film holders. Hand searches of the bibliographies were also conducted. Sixty articles (dating from 1896 to 1998) that describe new or improved film holders are reviewed here. RESULTS: From the earliest days of dental radiography, dentists attempted to standardize radiographic images and techniques. The focus of researchers in the 1950s to the 1970s was to develop a film holder that would hold the film and allow easy and predictable alignment of the X-ray tube. As research projects became more dependent on dental radiographic measurements, the focus shifted to producing reproducible radiographic images, from which highly repeatable measurements could be made. CONCLUSION: Existing devices have strengths and weaknesses. Readily available devices are adequate for routine clinical use; however, user-friendly and patient-friendly film-holding devices that result in highly reliable and accurate measurements have yet to be introduced.

Copying Processes↗

Precise image-receptor calibration and monitoring of beam quality with a step wedge.

OBJECTIVE: To describe an extended bootstrap calibration procedure that uses a step-wedge absorber and minimal equipment for rapid, accurate calibration of image receptors and simultaneous monitoring of beam quality. METHODS: Multiple radiographs of a step wedge are made at different exposures, with a precision dosimeter as a reference. An iterative least-squares minimization procedure is used to fit the data with a single calibration function. The calibration range can be extended by varying two exposure parameters in addition to stepwedge thickness. Small variations in beam quality and other experimental artifacts can be detected by testing redundant data for self-consistency. As a demonstration, two photostimulable phosphor (PSP) systems were calibrated, one with a well-regulated X-ray source and the other with a poorly regulated source. RESULTS: The first PSP system was calibrated over a range of 3.2 orders of magnitude with a relative standard deviation of the estimate of only 0.36%. The slope of the calibration curve agreed with the nominal, factory-set value within 0.8% (on a logarithmic scale). The second PSP system had a nearly linear response with a relative standard deviation of the estimate of 0.44% over the upper 97% of its range. Both X-ray sources showed easily detectable variations in tube potential. CONCLUSIONS: The new calibration method eliminates many of the sources of error of previous techniques such as inverse-square sensitometry. If a suitably precise X-ray source is available, the relative accuracy is limited only by the precision of the receptor system.

Absorption↗

The effects of different image file formats and image-analysis software programs on dental radiometric digital evaluations.

OBJECTIVES: To determine if variations in radiodensity data are introduced by lossy Joint Photographic Experts Group (JPEG) compression and/or the use of three software programs. METHODS: An occlusal film with an aluminium step wedge was exposed, processed and digitized under standard conditions. Before the image was saved, the coordinates and the gray-scale value for each pixel in a 20 x 20 pixel area near the middle of the thickest step were recorded. These pixel coordinates and gray-scale values served as Truth 1. In addition, a digital simulated-radiographic image with assigned gray-scale values for each pixel was created and served as Truth 2. The digital data for the scanned radiograph and the simulated radiograph were saved as Tagged Image File Format (TIFF) and lossy JPEG files. Each file was opened with three software programs and the gray-scale values of homologous pixels were recorded. For these pixels in each image type, the mean gray-scale values and standard deviations were calculated. The pixel gray-scale values for each homologous pixel were also individually compared. RESULTS: When the TIFF images were opened with the three software programs, one program resulted in gray-scale values that were not concordant with truth. All JPEG images resulted in gray-scale values that were not concordant with truth. CONCLUSIONS: One software program added a column of 0s to data files. Lossy JPEG compression introduced potentially deleterious variations to radiodensity data, and at least two of the software programs performed JPEG image decompression differently.

Absorptiometry, Photon↗

Gray scale sonography of breast masses in adolescent girls.

OBJECTIVE: To assess the sonographic findings of breast masses in adolescents and the usefulness of sonographic patterns for suggesting a specific diagnosis. METHODS: The sonograms and medical records of 57 girls (mean age, 15.4 years) with palpable breast masses were retrospectively reviewed. Three observers reviewed the sonograms for multiple sonographic findings. Surgery or clinical findings established diagnoses. Statistical analysis was done to determine how well sonographic findings alone and in combination agreed with final histologic diagnoses. RESULTS: Diagnoses included cysts (n = 12), abscesses (n = 7), fibroadenomas (n = 36), a lactating adenoma (n = 1), and a phyllodes tumor (n = 1). The sonographic findings varied significantly among lesion types (P < or = .005). CONCLUSIONS: Our experience suggests that virtually all breast masses in a pediatric population are benign and that sonography has the ability to differentiate among cystic, inflammatory, and solid masses.

Abscess↗

The clinical value of ferric ammonium citrate: a positive oral contrast agent for T1-weighted MR imaging of the upper abdomen.

This study was undertaken to determine whether ferric ammonium citrate (FAC), a positive magnetic resonance (MR) contrast agent, is of clinical value in demonstrating or excluding pathology of the upper gastrointestinal tract. A retrospective review was performed of pre- and post-FAC studies of MR examinations in 203 patients from phase II and III clinical trials in whom final diagnoses had been established based on the results of biopsy, surgery, or independent imaging procedures. Two independent reviewers made randomized and blinded assessments of the stomach, duodenum, and pancreas. FAC significantly increased the certainty of diagnosis for normal studies of the stomach and duodenum for both readers (P < 0.001) and for abnormal studies of the stomach for one reader (P = 0.004). FAC also significantly increased the certainty of diagnosis for normal pancreas for one reader (P < 0.001). FAC significantly (P < 0.001) increased accuracy and specificity for diagnoses involving the stomach and duodenum for both readers and for one reader for the pancreas. There was significant improvement in sensitivity for gastric diagnoses (P = 0.013) for one reader but not for the duodenum or pancreas. We conclude that FAC is helpful in demonstrating and excluding upper gastrointestinal pathology on MR.

Administration, Oral↗

Relationships between radiographic alveolar bone height and probing attachment level: data from healthy post-menopausal women.

OBJECTIVE: To determine the cross-sectional and longitudinal relationships between radiographic alveolar bone height and probing attachment level in a population of healthy postmenopausal women. MATERIALS AND METHODS: The 81 patients in this report were part of a prospective estrogen replacement interventional study. All patients were in good oral health at entry and received annual oral prophylaxis as part of the study. Standard probing measurements were made with a pressure sensitive probe at 6 sites on each tooth. Vertical bitewing radiographs were digitized, and 6 linear measurements corresponding to probing-site measurements were made from the cementoenamel junction to the alveolar crest. These procedures were performed at baseline and at annual intervals for three years. Data were analyzed both by site and by patient. RESULTS: Moderately strong correlations were found between cross-sectional measurements of probing attachment height and radiographic bone height. Correlations were stronger for patient data (r=0.44-0.61) than for site data (r=0.19-0.36). No relationships were found between longitudinal changes in alveolar bone height and attachment level in either the site data (r=-0.10-0.04). or the patient data (r=-0.005-0.10). CONCLUSION: Healthy patients may experience sporadic, temporary changes in attachment level or alveolar bone height which are resolved without one affecting the other.

Alveolar Bone Loss↗

Comparison of 5 protocols based on their abilities to use data extracted from digitized clinical radiographs to discriminate between patients with gingivitis and periodontitis.

BACKGROUND: This study was undertaken to compare 5 digital analytic protocols for their abilities to extract data from digital clinical radiographs and discriminate between patients with gingivitis and periodontitis. METHODS: Five digital-image analysis protocols were compared for their abilities to discriminate between two groups of 24 patients each. One group was diagnosed with healthy gingiva (or gingivitis) and the second with periodontitis. These groups were previously evaluated in published studies that used fractal and morphologic analyses. Pre-existing clinical radiographs for each patient were digitized and regions of interest (ROIs) were placed on interdental bone in mandibular posterior quadrants. The 5 protocols used were: 1) MGB: a median filtration to remove high-frequency noise, a Gaussian filtration to remove low-frequency noise, binarization of the resulting image, and quantification of the black pixels; 2) MGBS: the same protocol as MGB except for a skeletonization of the binary image and a quantification of the skeleton's pixels; 3) GBS: Gaussian filtration, binarization (thresholding on the mean pixel value) of the resulting image, skeletonization, and quantification of the pixels of the skeleton; 4) NS: normalization, skeletonization, and quantification of the skeleton's pixels; and 5) S: a variation of NS, except normalization was not used. The resulting values for the 2 patient groups were compared with Mann-Whitney U tests and effect likelihood-ratio test. RESULTS: For digitized radiographs, the mean gray-scale value (+/- standard deviation) for gingivitis patients was 183.22 +/- 18.53 and for periodontitis patients 181.26 +/- 17.20. Mann-Whitney U tests resulted in the following P values for these protocols: MGBS <0.01; S <0.01; GBS <0.01; NS <0.01; and MGB <0.83. Effect likelihood-ratio tests indicated that only MGBS and S significantly contributed to models containing the other factors. CONCLUSIONS: Small variations to protocols affected the strength of the discrimination between the gingivitis and periodontitis groups. While there is potential for morphologic analysis to be used to discriminate between patients with gingivitis and periodontitis, a robust technique was not identified.

Adult↗

Comparison of morphological measurements extracted from digitized dental radiographs with lumbar and femoral bone mineral density measurements in postmenopausal women.

BACKGROUND: We set out to determine whether morphologic measurements extracted from digitized images of bite-wing radiographs correlated with lumbar and femoral bone mineral density (BMD) measurements in 45 postmenopausal women who had no or only mild periodontal disease (no probing depths >5 mm). METHODS: Lumbar spine and femoral BMDs were determined by dual-energy x-ray absorptiometry. Vertical bite-wing radiographs were taken and digitized. Crestal and apical regions of interest (ROIs) were drawn on the digital images of the maxillary and mandibular alveolar bone on the patient's right and left sides. For each patient, a single morphologic measurement was made for each of 8 ROIs. Correlation analysis was performed to determine the strengths of the relationships between the morphologic measurements made at the 8 locations and between these morphologic measurements and BMD measurements. RESULTS: The correlations (r) between the morphologic operator (MO) measurements and lumbar spine and femoral BMDs were weak (mean r = 0.02, range = 0.32 to -0.26) and not statistically significant, with no clear trends discernible. Correlations between MO measurements made at the 8 alveolar sites were also weak (mean r = 0.05, range = 0.35 to -0.38) and not statistically significant. CONCLUSIONS: The MO measurements used in this study were weakly correlated with lumbar spine and femoral BMDs, with no clear trends discernible in this population of postmenopausal women with no or mild periodontal disease.

Absorptiometry, Photon↗

Alveolar bone height and postcranial bone mineral density: negative effects of cigarette smoking and parity.

BACKGROUND: Our objective was to test the association between cemento-enamel junction, alveolar-crest distance (CEJ-AC, as measured on digitized vertical bite-wing radiographs) and postcranial bone mineral density (BMD) relative to clinical, dietary, and demographic variables. METHODS: Data were collected in a cross-sectional study of 134 postmenopausal women. CEJ-AC distances were determined from digitized vertical bite-wing radiographs. Lumbar spine and proximal femur BMDs were determined from dual-energy x-ray absorptiometric scans. Correlation analysis and Student t tests were used to identify those variables most associated with CEJ-AC distance. The selected variables were modeled with a backward stepwise regression analysis, with CEJ-AC distance as the dependent variable. RESULTS: Parity (number of pregnancies to term), cigarette smoking, and the interaction of lateral spine BMD with cigarette smoking were independent predictors of CEJ-AC distance (P < or =0.05). Statistical models containing these variables accounted for 19% of the variation in CEJ-AC distances. CONCLUSIONS: CEJ-AC distance in postmenopausal women is the result of a complicated interaction of many effects, including but not limited to, parity, cigarette smoking, and skeletal BMD.

Absorptiometry, Photon↗

Sonographic differences in the appearance of acute and chronic full-thickness rotator cuff tears.

This study was undertaken to identify differences in the sonographic appearance of acute and chronic full-thickness rotator cuff tears. The ultrasonograms of 24 patients with an acute rotator cuff tear and 20 with a chronic tear were reviewed for tear size (width), location, and the presence and distribution of fluid. Among these 24 patients, 75% with a midsubstance tear location had an acute tear; 64% of patients with joint or bursal fluid had an acute tear; 80% of patients with a nonvisualized rotator cuff due to a massive tear had a chronic tear; and 73% of patients with no sonographic evidence of bursal or joint fluid had a chronic tear. In conclusion, a midsubstance location and the presence of joint or bursal fluid were more commonly associated with an acute tear. A nonvisualized cuff and the absence of joint and bursal fluid were more commonly observed with a chronic tear.

Acute Disease↗

Dental photostimulable phosphor radiography.

Photostimulable phosphor radiography (PPR), a mature industry in medical imaging, became available in dentistry in 1994. At least three dental PPR systems have been made available commercially since that time. Although dental PPR offers a number of advantages over film-based methods, some aspects of dental PPR need improvement. Further research is needed to more fully compare and contrast this modality with film-based methods.

Analog-Digital Conversion↗

Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons.

The objective of this study was to create three-dimensional (3D) images for the histomorphological study of osteons. Medical imaging technology was used to register digitized 2D images of serial decalcified histological sections of bone, to segment the tissues of interest from the surrounding tissues, and to create 3D reconstructions from the segmented structures. Examination of the 3D reconstructions did not support suggestions in the literature that osteons have a spiraling organization. In contrast, the 3D reconstructions indicated that osteons have a complex pattern of organization that is dominated by branching. Examination of the reconstructions also suggested that osteons described in the literature as being dumbbell shaped are actually artifacts of the plane of sectioning. This study demonstrated the applicability of imaging and visualization technology developed for the 3D reconstruction of medical images to the reconstruction of digitized 2D images of serial sections of bone and additionally demonstrated the feasibility of using 3D reconstructions for the histomorphological study of osteons.

Animals↗

The effect of region of interest variations on morphologic operations data and gray-level values extracted from digitized dental radiographs.

OBJECTIVE: To determine the correlations among morphologic operations (MO) values and the correlations among gray-level values for regions of interest (ROIs) placed at various locations on digital images of alveolar bone for 45 patients. STUDY DESIGN: As part of a larger study, up to 7 vertical bite-wing radiographs were taken and digitized for each of 45 patients. Sets of 2 rectangular ROIs were placed on the digitized images of interdental alveolar bone at 4 locations for each patient. The ROIs (1 crestal and 1 apical) were placed between second premolars and first molars in all 4 dental quadrants. Gray-level values were measured, and MO analysis was performed on each ROI. Descriptive statistics were calculated and correlations determined. RESULTS: Paired correlations (such as apical vs crestal, left vs right, maxillary apical vs mandibular apical) of MO values were weak (r = 0.01-0.21), but corresponding correlations for gray-level values were relatively strong (r = 0. 60-0.92). CONCLUSION: MO values varied with ROI location considerably more than did gray-level values. Additionally, ROI size and shape apparently affected MO data. Accurate placement and documentation of ROIs appear to be critical considerations in analyses that use MOs.

Alveolar Bone Loss↗

Computed radiography versus screen-film radiography: detection of pulmonary edema in a rabbit model that simulates neonatal pulmonary infiltrates.

PURPOSE: To determine if computed radiography is equivalent to screen-film radiography in depicting pulmonary edema and to determine if radiation exposure can be reduced with computed radiography while maintaining equivalent diagnostic accuracy for pulmonary edema. MATERIALS AND METHODS: Oleic acid was intravenously injected into three rabbits at each of four doses: 0, 0.02, 0.04, and 0.06 mL/kg. Two hours later, chest computed radiographs and screen-film radiographs were obtained at 60 kVp and 1.1 mAs. Additional computed radiographs were obtained after reducing milliampere seconds or by reducing milliampere seconds and increasing the kilovolt peak, which reduced bone marrow exposure by up to 20%. The presence of pulmonary opacities, "truth," was established by the wet-dry weight ratio and by chest computed tomography (CT). The radiographs were masked and randomized. Four observers rated the images for the presence of parenchymal opacities with a dichotomous score and judged the quality of the radiographs on a scale from 1 (worst) to 6 (best). Cochran Q tests and McNemar tests were used to analyze the differences in paired comparisons. Image quality was evaluated with logistic regression analysis. RESULTS: There was no significant difference between truth and observer ability to detect opacity for either modality or for any exposure (P > .05). There was no significant difference between computed radiography and screen-film radiography for image quality (P > .05). CONCLUSION: Computed radiography is equivalent to screen-film radiography in the detection of pulmonary edema. Radiation exposure reduction of 20% can be achieved without affecting pulmonary edema detection or image quality.

Animals↗

Anterior cruciate ligament tears: MR imaging-based diagnosis in a pediatric population.

PURPOSE: To evaluate the diagnostic accuracy of primary and secondary magnetic resonance (MR) imaging findings of anterior cruciate ligament (ACL) tears in young patients with immature skeletal systems. MATERIALS AND METHODS: MR images obtained in 43 patients aged 5-16 years who underwent arthroscopy were retrospectively reviewed. Two reviewers evaluated primary findings (abnormal signal intensity, abnormal course as defined by Blumensaat angle, and discontinuity), secondary findings (bone bruise in lateral compartment, anterior tibial displacement, uncovering of posterior horn of lateral meniscus, posterior cruciate ligament line, and posterior cruciate angle), and meniscal and other ligamentous injuries. RESULTS: There were 19 ACL tears and 24 intact ACLs. Overall sensitivity and specificity of MR imaging in detecting ACL tears were 95% and 88%, respectively. Sensitivities of the primary findings were 94% for abnormal Blumensaat angle; 79%, abnormal signal intensity; and 21% discontinuity. The specificity of all primary findings was 88% or greater. The sensitivity and specificity of the secondary findings, respectively, were 68% and 88% for bone bruise; 63% and 92%, anterior tibial displacement; 42% and 96%, uncovered posterior horn of lateral meniscus; 68% and 92%, positive posterior cruciate line; and 74% and 71%, abnormal posterior cruciate angle. Fifteen (79%) patients had meniscal tears, and five (26%) had collateral ligament injuries. CONCLUSION: Primary and secondary findings of ACL tears in young patients have high specificity and are useful for diagnosis.

Adolescent↗

Relationships between longitudinal changes in radiographic alveolar bone height and probing depth measurements: data from postmenopausal women.

BACKGROUND: The relationship between loss of radiographic alveolar bone height and probing attachment loss has been studied by a number of investigators, with mixed results. Recent studies have found weak correlations and have suggested that the relationship between bone loss and attachment loss is complex, perhaps because changes in bone height and attachment level are separated in time. METHODS: The 85 patients in this report were part of a prospective estrogen replacement interventional study. All patients were in good oral health at entry and received annual oral prophylaxis as part of the study. Standard probing measurements were made with a pressure-sensitive probe at 6 sites on each tooth. Vertical bite-wing radiographs were taken of each patient, radiographs were digitized, and 6 linear measurements (corresponding to probing site measurements) were made from the cemento-enamel junction to the alveolar crest. These procedures were performed at baseline and at annual intervals; this study reports results after 2 years. Data were analyzed both by individual site and by averaging identical sites from all measured teeth for each patient. RESULTS: Very weak direct relationships between change in alveolar bone height and change in attachment level were found in both the site data (r2=0.0022; P = 0.189) and the patient average data (r2=0.031; P= 0.104). CONCLUSIONS: The changes in these patients were probably due to systemic changes in bone health rather than to periodontal disease. However, the weak correlations between changes in attachment level and bone height are similar to recent studies of periodontal disease. Our results support suggestions in the literature that the link between changes in attachment and alveolar bone height is complex, perhaps because changes in the 2 tissue types are separated by a considerable time delay.

Age Factors↗

Morphologic operations used to distinguish between two patient populations differing in periodontal health.

OBJECTIVES: This study was conducted to determine whether morphologic operation procedures applied to digitized, non-standardized, clinical radiographs of mandibular alveolar bone could be used to distinguish between a population of patients diagnosed with periodontitis and a population of patients either diagnosed with gingivitis or having healthy gingivae. STUDY DESIGN: Two groups, one consisting of 29 patients who either had healthy gingivae or had been diagnosed with gingivitis and the other consisting of 32 patients who had been diagnosed with periodontitis, were compared. Pre-existing clinical radiographs were digitized, and for each patient three to six regions of interest were placed on an image of the mandibular posterior region of the interdental bone. The regions of interest were processed under two morphologic-operations protocols, and a mean density (referred to as an MO number) was calculated for each patient. With paired t-tests, the resulting MO numbers for the two groups were compared. RESULTS: The two populations were statistically different (p < 0.05). CONCLUSION: The results of this study indicate that morphologic operations have the potential to differentiate between patient groups differing in periodontal health.

Adult↗