Search PubMed⌕ Search

Biomedical subjects

C E Metz

Publications and source records attributed to C E Metz.

At least 55 records · Page 3Linked to original sources

Data compression: effect on diagnostic accuracy in digital chest radiography.

High-resolution digital images make up very large data sets that are relatively slow to transmit and expensive to store. Data compression techniques are being developed to address this problem, but significant image deterioration can occur at high compression ratios. In this study, the authors evaluated a form of adaptive block cosine transform coding, a new compression technique that allows considerable compression of digital radiographs with minimal degradation of image quality. To determine the effect of data compression on diagnostic accuracy, observer tests were performed with 60 digitized chest radiographs (2,048 x 2,048 matrix, 1,024 shades of gray) containing subtle examples of pneumothorax, interstitial infiltrate, nodules, and bone lesions. Radiographs with no compression, with 25:1 compression, and with 50:1 compression ratios were presented in randomized order to 12 radiologists. The results suggest that, with this compression scheme, compression ratios as high as 25:1 may be acceptable for primary diagnosis in chest radiology.

Humans↗

Effect of two rating formats in multi-disease ROC study of chest images.

ROC methodology has been expanded in recent years to include multi-disease experiments. To accommodate these changes, different rating formats, general or disease specific, can be used. No experimental data are available concerning the possible effects of the rating format on the results of these studies. We performed a multi-observer, multi-disease study in which 196 chest images were rated using a format where each disease was evaluated individually and one in which the cases were evaluated without scoring a specific disease. The results indicate that for our data set, the overall assessment of accuracy was not significantly affected by the study format used. Thus, in spite of the difficulties in selecting appropriate controls and the necessity of reassessing sample size considerations, the disease-specific format appears to produce an assessment of accuracy equivalent to that produced by the general format. This equivalence permits the use of the disease-specific approach since it more closely simulates the readers' true environment and is more appropriate for comparing imaging systems that may have a relative accuracy that is disease specific.

Diagnosis, Differential↗

Effect of observer instruction on ROC study of chest images.

Receiver-operating characteristic (ROC) analysis has been used in many medical imaging applications during the past decade. In order to ensure that reader-confidence ratings are analyzable (well distributed to meet convergence requirements of curve-fitting algorithms) and meaningful (limit extrapolation of the data), many investigators train readers specifically for this purpose. No experimental data are available concerning the possible effects of such training on the results of ROC studies. We performed a multi-observer, multi-disease study in which 300 chest images were rated by four radiologists before and after they were trained to provide well-distributed confidence ratings. The results indicate that for our data set, reader and disease-specific accuracy was not significantly affected by the training process for interstitial disease and pneumothoraces. However, the accuracy of two readers was significantly affected for the detection of nodules (P less than 0.05), and the overall accuracy of one reader was significantly affected for the classification of normal versus abnormal images (P less than 0.01). Thus, in spite of the difficulties associated with the performance of ROC studies in a free-reading environment, one should carefully consider the possible effects of any intervention on the results prior to conducting ROC studies.

Humans↗

Improvement in radiologists' detection of clustered microcalcifications on mammograms. The potential of computer-aided diagnosis.

Relatively simple, but important, detection tasks in radiology are nearing accessibility to computer-aided diagnostic (CAD) methods. The authors have studied one such task, the detection of clustered microcalcifications on mammograms, to determine whether CAD can improve radiologists' performance under controlled but generally realistic circumstances. The results of their receiver operating characteristic (ROC) study show that CAD, as implemented by their computer code in its present state of development, does significantly improve radiologists' accuracy in detecting clustered microcalcifications under conditions that simulate the rapid interpretation of screening mammograms. The results suggest also that a reduction in the computer's false-positive rate will further improve radiologists' diagnostic accuracy, although the improvement falls short of statistical significance in this study.

Calcinosis↗

Pulmonary nodules: computer-aided detection in digital chest images.

Currently, radiologists fail to detect pulmonary nodules in up to 30% of cases with actually positive findings. Diagnoses may be missed due to camouflaging effects of anatomic background, subjective and varying decision criteria, or distractions in clinical situations. We developed a computerized method to detect locations of lung nodules in digital chest images. The method is based on a difference-image approach and feature-extraction techniques, including growth, slope, and profile tests. Computer results were used to alert 12 radiologists to possible nodule locations in 60 clinical cases. Preliminary results suggest that computer aid can improve the detection performance of radiologists.

Adult↗

Detection of hepatic metastases: comparison of contrast-enhanced CT, unenhanced MR imaging, and iron oxide-enhanced MR imaging.

Diagnostic accuracy of contrast-enhanced CT, unenhanced MR imaging, and MR images enhanced with superparamagnetic iron oxide was evaluated in 10 patients with histologically proved hepatic metastases. First, diagnostic performance of the imaging technique with respect to the ability of radiologists to recognize the presence or absence of a metastasis was measured by using receiver-operating-characteristic (ROC) analysis of single images. Second, the total number of lesions (N = 108) detected by "complete" CT and MR examinations was counted. Finally, lesion-liver contrast-to-noise ratios (CNR) were measured in all MR sequences. The area under the ROC curve was .67 +/- .03 for contrast-enhanced CT, .81 +/- .07 for the unenhanced SE 260/14 sequence, and .92 +/- .01 for the iron oxide-enhanced SE 1500/40 sequence. The enhanced SE 1500/40 sequence yielded significantly (p less than .005) greater accuracy than did contrast-enhanced CT. The same sequence detected significantly (p less than .05) more lesions than all other imaging techniques (19% more than the best unenhanced MR sequence and 36% more than contrast-enhanced CT). The enhanced SE 1500/40 sequence also yielded the highest CNR value (19.5 +/- 10.2) of all MR sequences. These results indicate that iron oxide-enhanced MR imaging is a superior imaging technique for the detection of hepatic lesions.

Adult↗

Some practical issues of experimental design and data analysis in radiological ROC studies.

Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field often find--sometimes only after an ROC study is under way--that a number of subtle issues related to experimental design and data analysis must be confronted in practice. Many of these issues have not been discussed in the literature in detail, and most are not well known. The purposes of this paper are to make users of ROC methodology in medical imaging aware of potential problems that should be confronted before an ROC study is begun and to indicate, at least broadly, how those problems may be dealt with, given the present state of the art. Some of the issues raised here can be addressed adequately by easily prescribed techniques, whereas others remain difficult and will be resolved fully only by new methodologic developments.

ROC Curve↗

Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats.

Observer performance tests were conducted to compare the effects on diagnostic accuracy of hard copy (film) versus video display and to determine the diagnostic merits of conventional negative ("white bone") versus positive ("black bone") video displays. Subjective preferences were elicited from each observer for each display modality, and diagnostic accuracy was determined with receiver operating characteristic analysis. Digitized chest radiographs were used, including normal and abnormal cases with a variety of subtle abnormalities. The hard copy was printed with a 1,024 X 1,024-matrix by a high-quality drum scanner in conventional white bone format only. The video images were displayed on a 1,023-line monitor (30 Hz, interlaced) in both white bone and black bone formats with fixed window and brightness settings. Most observers preferred hard copy to video, but preferences were sharply divided between white bone and black bone video. Diagnostic accuracy was significantly greater with hard copy than with video display, and the conventional white bone format was significantly superior in accuracy to the black bone display.

Computer Systems↗

Digital mammography. ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications.

We investigated the spatial resolution requirement and the effect of unsharp-mask filtering on the detectability of subtle microcalcifications in digital mammography. Digital images were obtained by digitizing conventional screen-film mammograms with a 0.1 X 0.1 mm2 pixel size, processed with unsharp masking, and then reconstituted on film with a Fuji image processing/simulation system (Fuji Photo Film Co., Tokyo, Japan). Twenty normal cases and 12 cases with subtle microcalcifications were included. Observer performance experiments were conducted to assess the detectability of subtle microcalcifications in the conventional, the unprocessed digital, and the unsharp-masked mammograms. The observer response data were evaluated using receiver operating characteristic (ROC) and LROC (ROC with localization) analyses. Our results indicate that digital mammograms obtained with 0.1 X 0.1 mm2 pixels provide lower detectability than the conventional screen-film mammograms. The detectability of microcalcifications in the digital mammograms is improved by unsharp-mask filtering; the processed mammograms still provide lower accuracy than the conventional mammograms, however, chiefly because of increased false-positive detection rates for the processed images at each subjective confidence level. Viewing unprocessed digital and unsharp-masked images in pairs resulted in approximately the same detectability as that obtained with the unsharp-masked images alone. However, this result may be influenced by the fact that the same limited viewing time was necessarily divided between the two images.

Breast Neoplasms↗

ROC methodology in radiologic imaging.

If the performance of a diagnostic imaging system is to be evaluated objectively and meaningfully, one must compare radiologists' image-based diagnoses with actual states of disease and health in a way that distinguishes between the inherent diagnostic capacity of the radiologists' interpretations of the images, and any tendencies to "under-read" or "over-read". ROC methodology provides the only known basis for distinguishing between these two aspects of diagnostic performance. After identifying the fundamental issues that motivate ROC analysis, this article develops ROC concepts in an intuitive way. The requirements of a valid ROC study and practical techniques for ROC data collection and data analysis are sketched briefly. A survey of the radiologic literature indicates the broad variety of evaluation studies in which ROC analysis has been employed.

Biometry↗

Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.

Forty conventional radiographs with examples of mild interstitial infiltrates and subtle pneumothoraces and 40 normal studies of the chest were selected and digitized, with pixel sizes of 1.0, 0.5, 0.2, and 0.1 mm. Observer performance tests were carried out using receiver operating characteristic analysis. Conventional radiographs and digitized images were compared. The results indicate that, in such cases, diagnostic accuracy increases significantly as the pixel size is reduced, at least to the 0.1-mm level. We conclude that, for digital systems using screen-film or similar image receptors, use of a pixel size substantially larger than 0.1 mm may result in some loss of diagnostic accuracy.

Analog-Digital Conversion↗

Receiver operating characteristic analysis of regional cerebral blood flow in Alzheimer's disease.

Receiver operating characteristic (ROC) curves were used to quantitatively assess the ability of individual detectors in a 32-detector 133Xe inhalation system to discriminate between two populations over the range of regional cerebral blood flow (rCBF) values. These populations were clinically evaluated as normal (age 63.1 +/- 13.1, n = 23) and presumed Alzheimer's disease (age 72.7 +/- 7.0, n = 82). Summary statistics showed that for homologous detectors the average value of blood flow in the normal group was greater than the flow value in the group of subjects with Alzheimer's disease. Conclusions drawn from single values of flow or mean hemispheric flow can lead to erroneous conclusions about hemisphere asymmetries. However, the dynamic relationship between the correct identifications (true positives) compared with incorrect identifications (false positives) of Alzheimer's disease at each detector varies over the range of blood flow values, and quantitative characterization of this relationship in terms of an ROC curve provides more insight into the structure of the data. Detectors approximating the speech, auditory and association cortex were most effective in discriminating between groups. Frontal detectors were marginally useful diagnostically.

Aged↗

Clinical utility of the erythrocyte sedimentation rate in preoperative evaluation of solitary skeletal lesions.

We investigated the utility of the erythrocyte sedimentation rate in planning the diagnostic and surgical strategy for patients who were found by conventional radiography to have a solitary skeletal lesion. A series of 101 patients was separated into two groups according to their ultimate diagnoses. Group I included patients with skeletal metastases of unknown origin, unusual bone infections, and marrow cell tumors. Group II included benign and malignant primary bone tumors. Using the Westergren method to determine the erythrocyte sedimentation rate prior to biopsy, we found that only one of 65 Group II patients had a rate above 30 mm/h whereas 22 of 36 Group I patients had rates greater than 60 mm/h. By using Receiver Operating Characteristic analysis, we estimated the trade-offs between sensitivity and specificity that can be achieved with various threshold sedimentation rates. In particular, we found that a critical erythrocyte sedimentation rate of 30 mm/h allows separation of Group II patients from Group I patients with 96.9% sensitivity and 82.6% specificity. Our results indicate that the erythrocyte sedimentation rate can be used effectively in conjunction with conventional radiography in the planning of an appropriate further diagnostic strategy.

Adolescent↗