Pelvic imaging with phased-array coils: quantitative assessment of signal-to-noise ratio improvement.

The signal-to-noise ratios (S/Ns) of two different pelvic magnetic resonance (MR) imaging phased arrays were compared with that of the body coil. Each array consisted of two coils placed anteriorly and two posteriorly, oriented transversely in one array and longitudinally in the other. S/N measurements were obtained in an adjustable water-filled phantom that stimulated the shape and radio-frequency loading effects of various-size patients. Depending on the simulated anterior-posterior thickness of the patient, the S/N produced by the longitudinal array ranged from 2.3 to 3.1 times higher than that of the body coil. The S/N of the transverse array was 3.1 to 3.4 times higher. The increased coil sensitivity permits imaging with shorter acquisition times, smaller fields of view, finer resolution, and/or thinner sections. Two examples in patients demonstrate the enhanced imaging capability of the phased arrays.

Female↗

Single-breath-hold venous or arterial flow-suppressed pulmonary vascular MR imaging with phased-array coils.

A method for acquiring pulmonary vascular magnetic resonance (MR) images with either venous or arterial flow suppression is described. The proposed method only marginally increases the overall imaging time compared with conventional flow-suppression techniques. This enables an acquisition to be completed within a single breath hold with some selectivity as to flow direction. Instead of applying a spatially selective presaturation pulse before each radio-frequency (RF) excitation pulse, the flow presaturation pulse is applied once every 16-20 RF excitation pulses. To avoid image artifacts and to maintain a steady state, each presaturation pulse interval is followed by a normal imaging segment but with data acquisition turned off. Overall imaging time is increased by two TR intervals for each presaturation segment. For a 256 x 128 matrix acquisition, venous flow presaturation increases overall imaging time by approximately 14 TR intervals, while arterial flow suppression increases imaging time by 10 TR intervals.

Aged↗

Phase-correction method for reduction of B0 instability artifacts.

View-to-view phase shifts due to B0 instability are corrected by applying a phase correction to the low-spatial-frequency views. The algorithm described herein assumes that the signal intensity in the space outside of an object represents only noise. A set of phases for the low-spatial-frequency views are calculated by minimizing, in the image, the intensity of the induced artifacts in the space outside of the object.

Algorithms↗

Techniques for high-resolution MR imaging of atherosclerotic plaque.

Atherosclerotic cardiovascular disease is the most common cause of death in the United States. Investigation of atherosclerotic plaque morphology and composition is important because the findings may be useful in predicting prognosis or response to therapy. This study presents high-resolution magnetic resonance (MR) imaging techniques developed on a 1.5-T whole-body imager with a custom-built surface coil, for characterizing the composition and morphology of plaque removed at carotid endarterectomy. The initial comparison of MR imaging and histologic results showed good correlation. In conjunction with MR angiography, these techniques could be used in in vivo imaging to define the size, location, and contents of atherosclerotic plaque at the carotid bifurcation.

Artifacts↗

Phased-array magnetic resonance imaging of the carotid artery bifurcation: preliminary results in healthy volunteers and a patient with atherosclerotic disease.

A high resolution MR imaging technique using a custom designed flexible phased-array surface coil was developed to examine the wall of the carotid artery bifurcation in vivo. The phased-array consisted of two overlapping coils which increased the image signal-to-noise ratio at the depth of the carotid artery by approximately 70%, relative to a similarly sized single loop coil. The imaging protocol included a 2D T1-weighted (T1W) spin-echo scan and cardiac gated T2-weighted and proton density-weighted (PDW) fast spin-echo (FSE) scans. Images were obtained of six healthy volunteers and of one patient with known atherosclerotic disease several days before carotid endarterectomy. On T1W and PDW images of the healthy volunteers, the carotid arterial wall appeared to be comprised of two concentric rings; a high signal inner ring and a lower signal outer ring. The MR images of the patient revealed a calcified carotid bifurcation plaque which was confirmed during surgery. The endarterectomy specimen was imaged in vitro with MR and then sectioned histologically for correlation with the patients in vivo images. Our preliminary findings indicate that a high resolution technique may provide a noninvasive technique to study atherosclerosis of the carotid bifurcation.

Arteriosclerosis↗

Surface coil phased arrays for high-resolution imaging of the carotid arteries.

An MR phased-array coil assembly was developed to obtain high-resolution images of atherosclerotic plaques in the carotid artery. Images of volunteers and patients obtained by using alternative coil designs provided a subjective assessment of the coils' performance, field of view, ease of use, and susceptibility to motion artifacts. A quantitative measurement performed on a phantom indicated that a two-coil phased-array design should produce a 37% better signal-to-noise ratio at the carotids than would a conventional single 3-inch surface coil.

Arteriosclerosis↗

Pulmonary MR angiography utilizing phased-array surface coils.

Magnetic resonance angiography of the pulmonary vasculature was evaluated in 12 subjects using breath-hold gradient echo scans and surface coils at 1.5 T. Flow-compensated GRASS, spoiled GRASS (SPGR), and WARP-SPGR sequences were utilized. Comparisons were made among flip angles of 10-60 degrees, slice thicknesses of 3-10 mm, and body coil as well as Helmholtz pair and phased-array multiple coils. With 30-40 contiguous slices encompassing the lung, intrathoracic vasculature was segmented using a UNIX/X-windows based package dubbed VIDA. Three-dimensional anatomy was visualized by a brightest voxel projection algorithm, following reduction of chest wall pixel intensities by an operator-interactive module. Both SPGR (30 degrees flip angle, 4 mm slice thickness) and WARPSPGR (15 degrees flip angle, 5 mm slice thickness) in combination with phased-array multiple coils provided the most satisfactory images, based upon observations by three radiologists and signal-to-noise ratio measurements. The MR angiograms visualized vessels as distal as sixth to seventh order branches. The technique was successfully applied to three patients with pulmonary embolism. The results of this study demonstrate that the pulmonary vascular tree can be imaged by MR angiography combining a high resolution technique utilizing phased-array multiple coils, fast gradient echo sequences with breath-holding, and postprocessing of the volumetric image data. The technique is attractive since it is noninvasive and provides a full three-dimensional portrayal of the pulmonary vasculature.

Humans↗

Noise performance of surface coils for magnetic resonance imaging at 1.5 T.

In this paper we analyze the signal-to-noise ratio (SNR) for surface coil magnetic resonance imaging at 1.5 T. We have applied the treatment of Hoult and Lauterbur to determine the factors that most affect coil performance. We have imaged lossy phantoms with 8-, 10-, and 14-cm-diam circular surface coils and compared the results to body and head coil images. Surface coils can improve SNR by a factor of 4 or more for regions close to the surface. Surface coils are effective for regions up to 6 cm deep in the head and about 12 cm deep in the body. Nonuniformity of image intensity is a necessary requirement for improved SNR in surface coils. Coil losses make only a small contribution to image noise compared to tissue losses at 1.5 T. Surface coils need not be placed in close contact with the patient at 1.5 T.

Humans↗

Phased-array surface coil MR of the orbits and optic nerves.

PURPOSE: To devise a practical technique for high-resolution evaluation of the anterior optic apparatus using a phased-array surface coil system, and to evaluate this system in patients with suspected optic pathway abnormalities. METHODS: A four-element phased-array coil pair was placed on each side of the head, and signal-to-noise measurements were obtained using a head phantom. Comparison between the phased-array coil, the quadrature coil, and a single-turn 12.7-cm (5-in) surface coil was done. T1 spin-echo and T2 fast spin-echo sequences were obtained in the oblique axial and oblique sagittal planes, to approximate the long axis of the optic nerves and the nonoblique coronal plane. RESULTS: The phantom signal-to-noise measurements at simulated locations of the optic nerve head, optic canal, and optic chiasm revealed an improvement of at least 30% using the phased-array system. Of 24 imaged cases, 9 had trauma, 5 had suspected neoplasms, and 2 had optic neuritis. In 3 patients, an unexpected diagnosis of optic pathway contusion or infarction was made. The remaining 8 patients had various suspected visual pathway lesions. CONCLUSION: Phased-array surface coils allow rapid, thin-section imaging of the entire anterior optic pathway, with improved signal-to-noise ratio. This may improve evaluation of optic pathway lesions over conventional techniques.

Adolescent↗