C E Hann

Publications and source records attributed to C E Hann.

5 recordsLinked to original sources

Fast normalized cross correlation for motion tracking using basis functions.

Digital image-based elasto-tomography (DIET) is an emerging method for non-invasive breast cancer screening. Effective clinical application of the DIET system requires highly accurate motion tracking of the surface of an actuated breast with minimal computation. Normalized cross correlation (NCC) is the most robust correlation measure for determining similarity between points in two or more images providing an accurate foundation for motion tracking. However, even using fast Fourier transform (FFT) methods, it is too computationally intense for rapidly managing several large images. A significantly faster method of calculating the NCC is presented that uses rectangular approximations in place of randomly placed landmark points or the natural marks on the breast. These approximations serve as an optimal set of basis functions that are automatically detected, dramatically reducing computational requirements. To prove the concept, the method is shown to be 37-150 times faster than the FFT-based NCC with the same accuracy for simulated data, a visco-elastic breast phantom experiment and human skin. Clinically, this approach enables thousands of randomly placed points to be rapidly and accurately tracked providing high resolution for the DIET system.

Algorithms↗

Integral-based identification of patient specific parameters for a minimal cardiac model.

A minimal cardiac model has been developed which accurately captures the essential dynamics of the cardiovascular system (CVS). However, identifying patient specific parameters with the limited measurements often available, hinders the clinical application of the model for diagnosis and therapy selection. This paper presents an integral-based parameter identification method for fast, accurate identification of patient specific parameters using limited measured data. The integral method turns a previously non-linear and non-convex optimization problem into a linear and convex identification problem. The model includes ventricular interaction and physiological valve dynamics. A healthy human state and four disease states, valvular stenosis, pulmonary embolism, cardiogenic shock and septic shock are used to test the method. Parameters for the healthy and disease states are accurately identified using only discretized flows into and out of the two cardiac chambers, the minimum and maximum volumes of the left and right ventricles, and the pressure waveforms through the aorta and pulmonary artery. These input values can be readily obtained non-invasively using echo-cardiography and ultra-sound, or invasively via catheters that are often used in Intensive Care. The method enables rapid identification of model parameters to match a particular patient condition in clinical real time (3-5 min) to within a mean value of 4-10% in the presence of 5-15% uniformly distributed measurement noise. The specific changes made to simulate each disease state are correctly identified in each case to within 10% without false identification of any other patient specific parameters. Clinically, the resulting patient specific model can then be used to assist medical staff in understanding, diagnosis and treatment selection.

Algorithms↗

A novel, model-based insulin and nutrition delivery controller for glycemic regulation in critically ill patients.

BACKGROUND: Critically ill patients are often hyperglycemic and insulin resistant, as well as highly dynamic. Tight glucose control has been shown to significantly reduce mortality in critical care. A physiological model of the glucose-insulin regulatory system is improved and used to develop an adaptive control protocol utilizing both nutritional and insulin inputs to control hyperglycemia. The approach is clinically verified in a critical care patient cohort. METHODS: A simple two-compartment model for glucose rate of appearance in plasma due to stepwise enteral glucose fluxes is developed and incorporated into a previously validated system model. A control protocol modulating intravenous insulin infusion and bolus, with an enteral feed rate, is developed, enabling tight and predictive glycemic regulation to preset targets. The control protocol is adaptive to patient time-variant effective insulin resistance. The model and protocol are verified in seven 10-h and one 24-h proof-of-concept clinical trials. Ethics approval was granted by the Canterbury Ethics Committee. RESULTS: Insulin requirements varied widely following acute changes in patient physiology. The algorithm developed successfully adapted to patient metabolic status and insulin sensitivity, achieving an average target acquisition error of 9.3% with 90.7% of all targets achieved within +/-20%. Prediction errors may not be distinguishable from sensor measurement errors. Large errors (>20%) are attributable to highly dynamic and unpredictable changes in patient condition. CONCLUSIONS: Tight, targeted stepwise regulation was exhibited in all trials. Overall, tight glycemic regulation is achieved in a broad critical care cohort with optimized insulin and nutrition delivery, effectively managing glycemia even with high effective insulin resistance.

Aged↗

Model predictive glycaemic regulation in critical illness using insulin and nutrition input: a pilot study.

Stress-induced hyperglycaemia is prevalent in intensive care, impairing the immune response. Nutritional support regimes with high glucose content further exacerbate the problem. Tight glucose control has been shown to reduce mortality by up to 43% if levels are kept below 6.1 mmol/L. This research develops a control algorithm with insulin and nutritional inputs for targeted glucose control in the critically ill. Ethics approval for this research was granted by the Canterbury Ethics Committee. Proof-of-concept clinical pilot trials were conducted on intubated, insulin-dependent Christchurch ICU patients (n=7) on constant nutritional support. A target 10-15% reduction in glucose level per hour for a desired glucose level of 4-6 mmol/L was set. 43% and 91% of glucose targets were achieved within +/-5 and +/-20%, respectively. The mean error was 8.9% (0.5 mmol/L), with an absolute range [0, 2.9] mmol/L. End glucose levels were 40% lower compared to initial values. All large target errors are attributable to sudden changes in patient physiology at low glucose values, rather than systemic deficiencies. Target errors are consistent with and explainable by published sensor error distributions. The results show that intensive model-based glucose management with nutrition control reduced absolute glucose levels progressively while reducing the severity of glycaemic fluctuation even with significant inter-patient variability and time-varying physiological condition. Trials spanning longer periods of time are in development to verify the short-term pilot studies performed and to test the adaptability of the controller. Clinically, these results indicate potential in clinical use to reduce ICU mortality as well as reduce risk of severe complications.

Aged↗

Efficient implementation of non-linear valve law and ventricular interaction dynamics in the minimal cardiac model.

A minimal model of the cardio-vascular system (CVS) with ventricular interaction and inertial effects that accurately captures the physiological trends of a variety of disease states has been developed. However, the physiologically accurate open on pressure, close on flow valve law is computationally heavy to implement, reducing the model's potential clinical benefit. A significantly simpler representation of the valve law using Heaviside functions is derived and the ventricular interaction equations are reformulated to obtain a unique closed form analytical solution. The new formulation is tested and compared with the previous formulation for a healthy human and four clinically significant disease states: mitral and aortic stenosis, pulmonary embolism and septic shock. The new model formulation matches the previous model definition, differing by a mean model response error of no more than 0.2%. Computationally, it is 24 x faster than the previous method. More specifically, a short 20-beat simulation that took 102 s now requires 4.3 s, significantly improving the model's potential for practical use in a diagnostic and/or decision support role in the intensive care unit.

Cardiovascular System↗