An artificial neural network approach to quantitative single photon emission computed tomographic reconstruction with collimator, attenuation, and scatter compensation.

A spatially variant technique for quantitative single photon emission computed tomographic (SPECT) image reconstruction using an artificial neural network (ANN) is presented. This network was developed to simultaneously compensate for collimator, attenuation, and scatter effects during the reconstruction process. The network was trained using a supervised scheme which implemented the generalized delta rule. Training ended once the mean-squared error (MSE) between the ideal and reconstructed images converged to a minimum. After training, the ANN weights were held constant and could be used to reconstruct source distributions other than those used while training. In the absence of noise when only collimator effects were present, reconstruction of a Hoffman brain phantom had a 89% reduction in MSE compared to standard filtered backprojection. When collimator-and-attenuation and collimator-attenuation-and-scatter trials were tested against filtered backprojection with Chang attenuation compensation, the corresponding ANN reconstructions demonstrated 85% and 86% decreases in MSE, respectively. With noise present, and with standard noise reduction filters implemented prior to reconstruction, the ANN reconstructions displayed up to a 50% decrease in MSE compared to filtered backprojection reconstructions for 200,000 count data. These results demonstrate that an ANN can be used to reconstruct SPECT images with improved quantitative accuracy.

Biophysical Phenomena↗

Scatter compensation in digital chest radiography using the posterior beam stop technique.

A new scatter compensation technique for computed radiography based on posterior beam stop (PBS) sampled scatter measurements and the bicubic spline interpolation technique was proposed. Using only a single exposure, both the clinical image and an array of scatter measurements, which were interpolated into a smooth scatter-only image, were simultaneously acquired. The scatter was subtracted from the clinical image to generate the primary-only image. To gauge the accuracy of scatter estimation, both quantitative and interpolation errors were evaluated. The PBS measurements were compared against the standard beam stop method at 16 locations in an anatomical phantom, resulting in quantitative errors of 2.7% relative to the scatter or 6.8% relative to the primary. Also measured were the interpolation error over 64 interpolation sample locations and 64 midpoint sample locations in the anatomical phantom. The combined interpolation error was 1.9% relative to the scatter or 8.0% relative to the primary. At the interpolation sample locations, the errors were identical between the phantom radiograph and digital portable chest radiographs from five patients. By summing the quantitative and interpolation errors in quadrature, the overall error of the PBS SISTER (scatter interpolation-subtraction technique for radiography) method was 3.3% relative to the scatter or 10% relative to the primary, which was adequate for dual-energy imaging purposes (less than 10% error relative to the scatter or 20% relative to the primary). The change of image contrast, noise, and signal-to-noise ratio (SNR) at six locations in the anatomical phantom were quantitatively analyzed. Contrast and noise were equally enhanced in all anatomical regions, resulting in approximately the same SNR before and after compensation.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

Scatter compensation for digital chest radiography using maximum likelihood expectation maximization.

RATIONALE AND OBJECTIVES: An iterative maximum likelihood expectation maximization algorithm (MLEM) has been developed for scatter compensation in chest radiography. METHODS: The MLEM technique produces a scatter-reduced image which maximizes the probability of observing the measured image. We examined the scatter content and the low-contrast signal-to-noise ratio (SNR) in digital radiographs of anatomical phantoms before and after compensation. RESULTS: MLEM converged to an accurate (6.4% RMS residual scatter error) estimate within 12 iterations. Both contrast and noise were increased in the processed images as iteration progressed. In the lung, contrast was increased 108% and SNR was improved by 10%. In the retrocardiac region, contrast was increased 180% while SNR decreased by 6%. CONCLUSIONS: This is the first report of a post-acquisition scatter compensation technique which can increase SNR. These results suggest that statistical estimation techniques can enhance image quality and quantitative accuracy for digital chest radiography.

Algorithms↗

Observer evaluation of scatter subtraction for digital portable chest radiographs.

RATIONALE AND OBJECTIVES: The authors compared standard digital portable chest radiographs (DPCXR) to scatter-subtracted DPCXR: METHODS: Thirty DPCXR were obtained using a photostimulable phosphor digital imaging system and a posterior beam stop (PBS) technique that allowed measurement of the scatter component of the DPCXR: The scatter component was subtracted from the clinical image to form a scatter-subtracted image. Six observers recorded preference for the standard image or scatter-subtracted image for identifying five radiographic landmarks and for image quality. RESULTS: A statistically significant preference was demonstrated for the scatter-subtracted images and for viewing the tracheo-bronchial tree, right paratracheal stripe, vertebral column, and support apparatus position. For unprocessed images, there was a statistically significant preference for viewing the pulmonary vasculature. No statistically significant preference was demonstrated for overall image quality. CONCLUSIONS: These results suggest that PBS scatter subtraction holds promise for improving visualization of structures in high-scatter regions of chest radiographs.

Evaluation Studies as Topic↗

Artificial neural networks for single photon emission computed tomography. A study of cold lesion detection and localization.

RATIONALE AND OBJECTIVES: An artificial neural network was developed for cold lesion detection and localization in single photon emission computed tomography (SPECT) images. METHODS: The network was trained for several noise levels and lesion sizes to identify lesions located in the center of small image neighborhoods. When scrolled across an image the trained network was able to identify cold abnormalities. The diagnostic performance of the technique was evaluated at two noise levels (50,000 and 100,000 counts/slice) and for two lesion sizes (radius: 1.0 cm and 1.5 cm) using the free-response operating characteristic (FROC) analysis. Furthermore, the same network was tested on a situation it was not trained on (80,000 counts/slice and a different reconstruction filter). RESULTS: The neural network showed high sensitivity and small false-positive rates per image for all test situations. These results suggest that neural networks are promising tools for computer-aided clinical diagnosis in SPECT:

Equipment Design↗

Digital chest radiography with photostimulable storage phosphors: signal-to-noise ratio as a function of kilovoltage with matched exposure risk.

A photostimulable storage phosphor (PSP) digital radiography system was evaluated regarding the signal-to-noise ratio (S/N) on chest images acquired at differing peak kilovoltage settings but with matched risk from radiation exposure. Images of two chest phantoms were acquired by using bedside (portable) imaging equipment at tube voltages ranging from 60 to 120 kV. Exposure factors were set so that the effective dose equivalent, a risk estimator weighted for various organs, was approximately equal in all exposures. The S/N in the lung-equivalent regions was found to be slightly higher (maximum, 15%) in the low-energy exposures, while the S/N values in the mediastinum- and subdiaphragm-equivalent regions were approximately equal at all kilovoltage settings. The absence of a high sensitivity of S/N to kilovoltage in risk-matched PSP images should enable institutions to select x-ray beam quality on the basis of other imaging criteria.

Electricity↗

Measurement of scatter fractions in erect posteroanterior and lateral chest radiography.

Scatter fractions (SFs) measured in patients undergoing erect posteroanterior (PA) and lateral chest radiography with a 12:1 antiscatter grid are reported. Modifications to the posterior beam-stop (PBS) technique allowed measurement of scatter in these patients, without altering the diagnostic image and without additional radiation exposure. The SF measurements are reported by anatomic location on 42 clinical chest images. Average SF values ranged from 0.27 to 0.90 on lateral radiographs and from 0.27 to 0.68 on PA radiographs. Scatter measurements with the 12:1 grid were found to be greater than estimates from previous PA chest phantom experiments. To the authors' knowledge, they were the first to measure radiation scatter with the PBS technique in patients undergoing PA and lateral chest radiography with the antiscatter grid.

Adult↗

Acute pulmonary embolism: artificial neural network approach for diagnosis.

PURPOSE: To investigate use of an artificial neural network (ANN) as a computer-aided diagnostic (CAD) tool for predicting pulmonary embolism (PE) from ventilation-perfusion lung scans and chest radiographs. MATERIALS AND METHODS: The data base consisted of cases extracted from the collaborative study of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). Initially, scan findings from 1,064 patients (383 with PE, 681 without PE) were used to train and test the network by using the "jackknife" method. Then, a receiver-operating-characteristic analysis was applied to compare the performance of the network with that of the physicians involved in the PIOPED study. RESULTS: The ANN significantly outperformed the physicians involved in the PIOPED study (two-tailed P value = .01). CONCLUSION: The findings suggest that an ANN can form the basis of a CAD system to assist physicians with the diagnosis of PE.

Acute Disease↗

Film-based chest radiography: AMBER vs asymmetric screen-film systems.

OBJECTIVE: Contrast-to-noise ratios were measured on radiographs from two types of state-of-the-art chest imaging systems (an Advanced Multiple Beam Equalization Radiography [AMBER] system and an asymmetric screen-film system) to facilitate an objective comparison of image quality. MATERIALS AND METHODS: Radiographs of a chest phantom were obtained by using the AMBER system with a medium-latitude screen-film image recorder (Kodak T-MAT L film and Lanex regular screens) and a commercially available asymmetric, zero-crossover screen-film system optimized for chest radiography (Kodak InSight and InSight HC). Conventionally acquired radiographs (T-MAT L/Lanex regular) were also evaluated as a reference. Films were digitized, radiographic contrast and noise were measured in the lung-, mediastinum-, and subdiaphragm-equivalent regions of each image, and contrast-to-noise ratios were computed. RESULTS: Radiographic contrast and contrast-to-noise values were found to be higher on AMBER images in all chest regions when compared with radiographs obtained with the asymmetric screen-film systems (InSight contrast-to-noise ratio approximately 77% of AMBER contrast-to-noise in the lung-equivalent region, 57% in the mediastinum-equivalent region, and 43% in the subdiaphragm-equivalent region). On conventional radiographs, the contrast and contrast-to-noise values were higher than on all other image types in the lung-equivalent region and lower than on all other image types in the less well penetrated chest areas. CONCLUSION: Image quality was higher, most notably in dense phantom regions, on radiographs obtained with the AMBER system than on radiographs obtained with the new asymmetric screen-film systems. Clinical studies are needed to determine whether this level of image improvement justifies the additional expense of the exposure equalization system.

Humans↗

Three-dimensional photon detection kernels and their application to SPECT reconstruction.

In single photon emission computed tomography (SPECT), three-dimensional photon detection kernels characterize the probabilities that photons emitted by radio-isotopes in different parts of the source region will be detected at particular projection pixels of the projection images. Monte Carlo modelling is used to study these kernels for the case of parallel hole collimators. The use of vectorized Monte Carlo computer code speeds the modelling computations. The contributions of direct and scattered photons to projection data in a transverse plane from neighbouring planes are significant for the case of uniform activity within a water-filled cylinder. A reconstruction method using the 3D kernels is proposed in which projection measurements in three adjacent planes are used simultaneously to estimate the source activity of the center plane. This multiple slice method accounts for the fact that photons detected in a given transverse plane may have originated in other transverse planes with different activity distributions. The matrix equations for image reconstruction are solved using generalized matrix inverses. The new method shows compensation for 3D photon detection effects when applied to projection data from a numerical simulation and a cardiac phantom experiment. Quantitation for the numerical study is improved compared with results from a single slice reconstruction method.

Heart↗

Posterior beam-stop method for scatter fraction measurement in digital radiography.

The authors presented a new posterior beam-stop (PBS) technique for measuring the ratio of scattered to total-detected photon flux (scatter fraction) in a radiographic examination while preserving the diagnostic quality of the image. The scatter measurement was made using a standard imaging geometry with both beam stops and an additional x-ray detector placed behind the standard imaging detector. This PBS geometry differs from the standard beam-stop (SBS) technique for scatter measurement. With SBS, a beam-stop shadow appears on the image. To evaluate the PBS technique, scatter fraction measurements were performed on an anatomic phantom using both the PBS and SBS techniques. When compared with the standard technique, PBS provided accurate estimation of scatter fractions. Since the measurement can be performed without degrading a standard clinical radiographic examination, the PBS technique allows simultaneous acquisition of scatter measurements from human patients in combination with a standard radiographic examination.

Filtration↗

An artificial neural network for lesion detection on single-photon emission computed tomographic images.

RATIONALE AND OBJECTIVES: An artificial neural network (ANN) has been developed to detect nonactive circular lesions on single-slice, single-photon emission computed tomographic (SPECT) images reconstructed using filtered back projection (FBP). METHODS: The neural network is a single-layer perception which learns to identify features on the SPECT image using supervised training with a modified delta rule. The network was trained on a set of SPECT images containing clinically realistic levels of noise. The trained network was applied to a set of 120 images, and the detection performance was evaluated at several decision thresholds using receiver operating characteristic (ROC) analysis. RESULTS: The trained neural network performed better than human observers for the same detection task with the same images as reflected by a significantly larger ROC curve area. CONCLUSIONS: ANN can be trained successfully to perform lesion detection on reconstructed SPECT images.

Equipment Design↗

Measurement of scatter fractions in clinical bedside radiography.

The authors present measurements of scatter fraction (SF), the ratio of scattered to total imaged photons, from clinical bedside radiographs of 102 patients. These measurements were obtained by using a new posterior beam-stop technique that does not alter the diagnostic image but that simultaneously provides SF measurements at 224 locations in the image. The SF values in the lung were found to be consistent with previous measurements, while the SF values in the mediastinal and retrocardiac areas were larger than previously reported. SFs in diseased lung were significantly larger than SFs in normal lung. The range of SF values was large for all anatomic locations. For applications in which accurate scatter estimation is required, this wide range of values suggests that SFs should be measured in each individual image.

Female↗

Testing of local gamma-ray scatter fractions determined by spectral fitting.

The spectral-fitting method of correction for gamma-ray Compton scattering within objects separates the unscattered and scattered components of locally measured energy spectra. Here, we employ a third-order polynomial for the scattering and an approximately constant fitting window. A scatter fraction, defined as total scattered over total unscattered counts within a 20% window, is calculated for each point in our Anger camera images. These scatter fractions are tested against those from Monte-Carlo simulation for 99mTc and against results from semiconductor detector measurements for 131I. A radioactive sphere at several locations within a non-radioactive cylinder and the inverse are imaged for the testing. For one case, reproducibility of the spectral-fitting scatter fraction as a function of the number of unscattered counts within the 20% acceptance window was also determined. With 99mTc, for all cases, the agreement between spectral fitting and the standard estimation method is within 16%. With 131I, for the 'hot' sphere at two locations, the agreement is within 21%. For the 'hot' sphere at the third location (off the cylinder axis towards the camera), the dependence of scatter fraction on transverse distance is good although the absolute values are too large. Scatter fraction reproducibility is within 10% for 1000 or more counts. Therefore, further testing of spectral fitting and initial application to realistic clinical images seem to be in order.

Gamma Cameras↗

Single-exposure conventional and computed radiography image acquisition.

A technique for simultaneously acquiring a conventional film-screen radiographic image and a digital computed radiography (CR) image with a single x-ray exposure is described. Measurements of image contrast, spatial resolution, and signal-to-noise ratios demonstrate that a modified film cassette in which the first intensifier screen has been replaced with a CR imaging plate permits dual-image, single-exposure imaging with only nominal degradation in film and CR image quality relative to the two standard image counterparts. This technique may be used to acquire matched image pairs for research or as a way to provide full-size conventional film images in the clinical environment, while retaining the advantages offered by computed radiography systems.

Humans↗

Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images.

This paper studies the extent to which lesion contrasts and signal-to-noise ratios in maximum-likelihood, expectation-maximization estimates of SPECT images can be improved by considering Compton scattering when calculating the photon detection probability matrix. Matrices are generated using a Monte Carlo code that realistically models a SPECT imaging system. For cold lesions having true contrasts of one, thirty-six combinations of three lesion sizes, three lesion locations, and four projection-data count levels are considered. Both hot and cold, 2-cm-radius lesions having various values of true contrast are studied at a few count levels and lesion locations. With scatter in the matrix, scatter effects are completely removed from the central regions of lesions whose radius is greater than the full width at half maximum of the spatial resolution. Resolution recovery is initially slower but eventually superior. Percent improvements in contrast are greater for lower-contrast cold lesions and higher-contrast hot lesions. In most cases, signal-to-noise ratios are comparable or better. Correct absolute activity levels are obtained.

Humans↗

Scatter fractions in AMBER imaging.

Images of two phantoms were obtained with use of an advanced multiple-beam equalization radiography system, and scatter fractions were estimated with use of a photostimulable phosphor imaging system. Scatter fractions in the equalized images were lower in the mediastinum-equivalent areas and higher in the lung-equivalent areas, relative to images that were conventionally acquired with use of an antiscatter grid. The differences are attributed to a reduction in incident exposure in the lungs and the presence of cross-scatter between lung and mediastinal regions.

Radiography, Thoracic↗