Search PubMed⌕ Search

Biomedical subjects

C Dotson

Publications and source records attributed to C Dotson.

3 recordsLinked to original sources

Oxygen consumption during fire suppression: error of heart rate estimation.

Ten male firefighters were tested on a treadmill to determine their heart rate (HR) x oxygen consumption (VO2) relationship. These men then performed a simulated fire suppression protocol during which HR and VO2 were measured simultaneously by a portable physiological monitoring system. Average VO2 in the simulated setting was 31.0 +/- 7.0 ml.kg-1.min-1 at a HR of 176 +/- 9 bpm. This VO2 was significantly (p less than or equal to 0.05) less than the VO2 that would have been predicted by treadmill testing (38.9 +/- 5.0 ml.kg-1.min-1) at a corresponding HR. Fifty-nine per cent of this variability could be accounted for by regression analysis. Firefighters worked on average at 73 +/- 10% VO2 max with a range of 54% to 88%. There was a significant (-0.82; p less than or equal to 0.05) inverse relationship between performance time of the fire suppression protocol and the relative intensity of VO2 max at which the firefighters worked. These findings indicate that the prediction of energy expenditure from HR is not straightforward in fire suppression settings. Furthermore, the relative intensity of work firefighters self-select is variable and should be considered as an additional physiological determinant of work behaviour.

Adult↗

Optimized blood cell profiling method for genomic biomarker discovery using high-density microarray.

High-quality biomarkers for disease progression, drug efficacy and toxicity liability are essential for improving the efficiency of drug discovery and development. The identification of drug-activity biomarkers is often limited by access to and the quantity of target tissue. Peripheral blood has increasingly become an attractive alternative to tissue samples from organs as source for biomarker discovery, especially during early clinical studies. However, given the heterogeneous blood cell population, possible artifacts from ex vivo activations, and technical difficulties associated with overall performance of the assay, it is challenging to profile peripheral blood cells directly for biomarker discovery. In the present study, Applied BioSystems' blood collection system was evaluated for its ability to isolate RNA suitable for use on the Affymetrix microarray platform. Blood was collected in a TEMPUS tube and RNA extracted using an ABI-6100 semi-automated workstation. Using human and rat whole blood samples, it was demonstrated that the RNA isolated using this approach was stable, of high quality and was suitable for Affymetrix microarray applications. The microarray data were statistically analysed and compared with other blood protocols. Minimal haemoglobin interference with RNA labelling efficiency and chip hybridization was found using the TEMPUS tube and extraction method. The RNA quality, stability and ease of handling requirement make the TEMPUS tube protocol an attractive approach for expression profiling of whole blood to support target and biomarker discovery.

Animals↗