Search PubMed⌕ Search

Biomedical subjects

C Donayre

Publications and source records attributed to C Donayre.

32 records · Page 2Linked to original sources

Bifurcated stent-grafts for endovascular repair of abdominal aortic aneurysm. Preliminary case reports.

This report describes the first clinical experience with transfemoral insertion of an endovascular bifurcated graft for repair of an abdominal aortic aneurysm. Graft placement was performed through bilateral femoral arteriotomies. There was no graft migration, no leakage, and unobstructed flow to the common iliac arteries was documented by angiography and Duplex ultrasonography in both cases. Both patients were eating a normal diet and ambulating on the first postoperative day.

Aged↗

Innovations in vascular imaging: arteriography, three-dimensional CT scans, and two- and three-dimensional intravascular ultrasound evaluation of an abdominal aortic aneurysm.

This report compares the information obtained from arteriography, CT scans, and intravascular ultrasound evaluation of an abdominal aortic aneurysm. The two- and three-dimensional imaging techniques described in this report add information that is redefining the pre- and intraoperative analysis of arterial lesions. The new data may have an influence on the evolution of diagnostic methods and future interventional therapy for vascular disease. This case highlights the developing potential of the methods.

Aged↗

Changes in arterial wall compliance after endovascular stenting.

PURPOSE: The response of arterial wall to endovascular stenting after angioplasty is not well understood. Additionally, changes in the elastic properties of stented vessels are unknown in situ. Vascular compliance was measured in normal canine iliac arteries (n = 11) before and after intravascular ultrasound-guided deployment of self-expandable metallic stents. METHODS: Nine animals were restudied and killed 1, 2, and 4 weeks after initial deployment, and two dogs were studied at deployment only. An absolute induction angiometer was used to make in situ measurements of vessel compliance via catheter-based delivery. The angiometer consists of a wire loop probe, which conforms to the diameter of the vessel in which it is placed. Systolic/diastolic changes in loop diameter are translated into measureable changes of induced voltage. RESULTS: Mean compliance of the artery before and immediately after stenting was 4.4 +/- 2.1 and 1.9 +/- 2.0 (x 10(-2) diameter %/mm Hg), respectively. As early as 1 week after deployment, stented arteries began to lose expansile properties, and some were noncompliant. At explantation diminished compliance was accompanied by a periadventitial fibrous reaction around stented vessels. A thin, unobstructing layer of neointimal hyperplasia covered the iliac stents at all intervals, and all vessels remained patent and free of thrombus. CONCLUSIONS: The potential advantages provided by a flexible, radially compliant stent are lost within a relatively short time after implantation in nonatherosclerotic canine arteries.

Animals↗

An evaluation of new methods of expressing aortic aneurysm size: relationship to rupture.

The diameter of aortic aneurysms were standardized to measures of patient size and normal aortic size in an effort to define indexes that might be more predictive of aneurysm rupture than raw aneurysm diameter alone. Normal aortic diameters were measured in 100 patients undergoing abdominal CT scans for other reasons, and an average infrarenal aortic diameter of 2.10 +/- 0.05 cm was observed. Normal aortic diameter was dependent on both age and sex, ranging from 1.71 +/- 0.06 cm in women below age 40 years to 2.85 +/- 0.04 cm in men above age 70 years. Overall, 11 (5.1%) of the ruptures occurred in aneurysms less than 5 cm in diameter, and four (1.9%) occurred in aneurysms less than 4.0 cm in diameter. When the CT scans of 100 patients undergoing elective aneurysm resection were compared with those of 36 patients with ruptured aneurysms, no threshold diameter value accurately discriminated between the two groups. However, standardization of the aneurysm diameter to the transverse diameter of the third lumbar vertebral body as an index of patient body size produced an accurate predictor of rupture when a threshold ratio of 1.0 was used. No aneurysm ruptured below this ratio, but 29% of elective aneurysms were smaller than the vertebral body diameter. Receiver operating characteristic curve analysis confirmed the superiority of the aneurysm to vertebral body diameter ratio as a discriminator of ruptured aneurysms. It appears that aneurysm diameter alone is not sufficiently predictive of rupture to be used as the sole indication for elective resection.

Adult↗

The hemodynamics of thrombus formation in arteries.

Alterations in arterial blood flow are thought to predispose to thrombus formation, but the exact relationships have not been fully elucidated. The effect of varying blood flows on the accumulation of thrombotic material within arteries was investigated, with use of shear rate as an index of flow across the luminal surface. Partially denuded rabbit aortas were perfused with fresh nonanticoagulated human blood for 3 minutes, with an in vitro recirculating apparatus, Indium 111-labeled platelets, and fibrinogen I 125. Shear rates ranged from zero to 1500 sec-1, correlating with the hemodynamics of various segments of the human arterial tree. A significant correlation was observed between shear rate and platelet deposition, ranging from 5.2 +/- 2.8 x 10(6) platelets/cm2 of vessel surface area at zero shear to a maximum of 64.7 +/- 8.3 x 10(6) platelets/cm2 at a shear rate of 1500 sec-1 (F = 5.01, p less than 0.05). Fibrin deposition paralleled that of platelets, ranging from 28.2 +/- 7.6 micrograms/cm2 at zero shear to 354.1 +/- 62.7 micrograms/cm2 at a shear rate of 1500 sec-1 (F = 5.91, p less than 0.05). These results suggest that shear rate is a most important determinant of platelet and fibrin deposition on altered arterial surfaces.

Animals↗

Large vessel sealing with the argon laser.

This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively.

Animals↗

Valvulotomy in in situ vein bypasses performed by angioscope-assisted laser probe.

The objective of this study was to evaluate the use of an angioscope-assisted laser hot-tip probe for performing valvulotomies in in situ nonreversed canine veins used for arterial bypasses. In Group 1, 9 valvulotomies were performed in 7 bypass veins with a 2-mm probe activated by 12 W power, resulting in 4 vein perforations, 1 vein thrombosis, and 4 in situ grafts patent at removal after 2-28 days. In Group 2, 10 valvulotomies in 9 bypass veins were performed with a 1.5-mm probe at 14 W with no vein perforations, 3 vein thromboses, and 6 in situ grafts patent at removal after an interval of 1 to 6 weeks. We conclude that valvulotomy within in situ vein bypasses can be successfully performed using a 1.5-mm laser hot-tip probe at 14 W power, with patency of the grafts demonstrated at 6 weeks. Angioscope-assisted laser valvulotomy using a laser probe may significantly reduce the length of incisions and the time required for in situ vein bypasses and improve the technical accuracy of the procedure.

Animals↗

Argon laser-welded arteriovenous anastomoses.

This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line.

Animals↗

Comparison of laser-welded and sutured arteriotomies.

We compared the histologic features, tensile strength, and collagen synthesis of laser-welded and sutured arteriotomies. Four bilateral canine femoral or carotid arteries, 2 cm long, were studied at one through four weeks postoperatively, with one vessel (control) closed with interrupted 6-0 polypropylene sutures and the contralateral vessel (experimental) welded with an argon laser (0.5 W [1417 J/cm2], four-minute exposure per 1-cm length of incision). Histologic examination revealed that laser-welded arteriotomies had less inflammatory reaction, more normal collagen and elastin reorientation, and similar endothelial continuity when compared with the control, sutured wounds. The tensile strength of the one- and two-week laser-welded specimens was less than that of sutured wounds and became approximately equal to sutured repairs at three and four weeks. There were no significant differences in the rate of collagen synthesis. There was no evidence of abnormal healing in the laser-welded specimens, suggesting that argon laser welding may be an alternative to suture repair of arteriotomies.

Animals↗

Anterior patch aortic aneurysm model for the study of endoluminal grafts.

Endovascular graft repair for aortic aneurysms has led to concerns regarding the healing characteristics of the graft within a thrombus-lined aneurysm and the effect that collateral flow may have on the endoluminal prosthesis and the aneurysm. An anterior aortic patch aneurysm model that preserved collateral arteries was examined and modified to address these issues. In canines (n = 30) a Dacron knitted patch (n = 27) or a rectus fascia patch (n = 3) was sutured into a 3.5-cm anterior aorotomy. Dacron patch aneurysm diameter was an average of 21.8 +/- 2.2 mm (mean canine normal aortic diameter 9.06 +/- 0.79 mm). Canines underwent angiogram, computed tomography, and/or intravascular ultrasound from 1 to 11 weeks later, at which time an endoluminal prosthesis was deployed and followed 30 to 60 days until harvest. Aneurysms accumulated minimal thrombus through the initial 11 weeks. Significant stenosis (mean 21.2% +/- 19%) occurred at aneurysm necks in association with a patch imbrication suture technique (n = 11). Following modification (n = 16), this decreased to a mean of 3.6 +/- 9.7%. Collateral lumbar artery patency was 95% at the time of imaging prior to graft placement. Following successful graft implantation, 16 of 18 aneurysms were filled with thrombus and in most cases the collateral circulation occluded. One of three fascial patch aneurysms ruptured 21 days after creation. This model more accurately depicts abdominal aortic aneurysms with the inherent thrombus and collateral flow that is important when studying aspects of endovascular aortic graft repair.

Animals↗

Laser welding of large diameter arteries and veins.

Based on our preliminary studies and the results of this study, we conclude that argon laser welding of 4-8 mm internal diameter veins, arteries, and arteriovenous fistulas may have several potential advantages compared to conventional suture techniques. The benefits of laser repairs may include improved mechanical properties, and absence of the foreign body response related to sutures. Laser welding is sterile, nontactile and possibly time conserving, and the wounds heal rapidly without aneurysms or excess tissue proliferation.

Animals↗

[Cervical teratoma].

Explore the source record for details and available documents.

Dentistry↗