Publications and source records attributed to C De Wagter.

At least 19 recordsLinked to original sources

The value of radiochromic film dosimetry around air cavities: experimental results and Monte Carlo simulations.

In this study we investigate radiochromic film dosimetry around air cavities with particular focus on the perturbation of the dose distribution by the film when the film is parallel to the beam axis. We considered a layered polystyrene phantom containing an air cavity as a model for the air-soft tissue geometry that may occur after surgical resection of a paranasal sinus tumour. A radiochromic film type MD-55 was positioned within the phantom so that it intersected the cavity. Two phantom set-ups were examined. In the first case, the air cavity is at the centre of the phantom, thus the film is lying along the central beam axis. In the second case, the cavity and film are located 2 cm offset from the phantom centre and the central beam axis. In order to examine the influence of the film on the dose distribution and to interpret the film-measured results, Monte Carlo simulations were performed. The film was modelled rigorously to incorporate the composition and structure of the film. Two field configurations, a 1 x 10 cm2 field and a 10 x 10 cm2 field, were examined. The dose behind the air cavity is reduced by 6 to 7% for both field configurations when a film that intersects the cavity contains the central beam axis. This is due to the attenuation exerted by the film when photons cross the cavity. Offsetting the beam to the cavity and the film by 2 cm removes the dose reduction behind the air cavity completely. Another result was that the rebuild-up behind the cavity for the 10 x 10 cm2 field, albeit less significant than for the 1 x 10 cm2 field, could only be measured by the film that was placed offset with respect to the central beam axis. Although radiochromic film is approximately soft-tissue equivalent and energy independent as compared to radiographic films, care should be taken in the case of inhomogeneous phantoms when the film intersects air cavities and contains the beam central axis. Errors in dose measurement can be expected distal to the air cavity due to attenuation in the film itself. This attenuation would not occur in the absence of the film. Both experiments and Monte Carlo computations support this conclusion.

Air↗

Monte Carlo model of the Elekta SLiplus accelerator: validation of a new MLC component module in BEAM for a 6 MV beam.

A new component module (CM), called MLCE, has been implemented in the BEAM program. The CM takes into account the particular 'tongue-and-groove' design of the Elekta multi-leaf collimator (MLC) and the air gap between the leaves. The model was validated by two series of measurements and simulations. The first benchmarking series focuses on the interleaf leakage and the intraleaf transmission. The measurement showed a total transmission through the MLC of 1.42% of the open field dose. Two Monte Carlo (MC) simulations were made, the first with the new CM MLCE (inclusive of air gap) and the second with the CM MLCQ (exclusive of air gap), which is available in the BEAM distribution. When the air gap between the leaves was determined by varying the parameters of the leaf geometry within tolerance limits on the technical drawing, the total measured transmission of 1.42% was well reproduced by the CM MLCE. In contrast, MC simulations with MLCQ showed that the transmission through the MLC calculated without the interleaf leakage is only 44% of the total transmitted radiation. The relevance of the detailed MLC modelling was demonstrated also by studying the 'adjacent' tongue-and-groove effect, where two adjacent (not opposing) leaves are complementary, opened or closed. The two complementary leaf settings were simulated both with the CM MLCE and MLCQ. A comparison with measurements was made. In regions covered by two or more leaves, the dose increased by 14% for two leaves and by 40% for more than two leaves when the interleaf leakage was included in the transmission. The tongue-and-groove effect was perfectly reproduced by the MLCE module.

Algorithms↗

The value of radiographic film for the characterization of intensity-modulated beams.

In this paper the performance of radiographic film (KODAK X-Omat V) for analysing intensity-modulated (IM) beams in a plane at reference depth (5 cm for 6 MV, 10 cm for 18 MV) was investigated. The field size dependence of the film response was studied for small and medium field sizes. The dose rate dependence of the response and possible effects of fractionating the dose were assessed. In the end, profiles were measured for two clinically delivered IM beams, and the results were compared with diamond detector data. We found that the response of the radiographic film increases with field size, but for field sizes up to 15 x 15 cm the deviations remain within 3% for measurements with the films in a plane at reference depth. We found that the response of the films decreases with decreasing dose rate, and that the extent of this effect differs from film batch to film batch. For clinical IM beams the effect can amount to about 9% at the location of shielded organs at risk. Also, fractionating the dose reduces the net optical density, but this effect is normally small when assessing IM beams. In low-dose regions low-energy photons have an important contribution, resulting in a higher response at these positions. This may counteract the dose rate dependence of the response. In the high-dose regions of the two IM beams that were studied, the relative dose measurements with film are within 1% of those obtained with a diamond detector, when the results of three films are averaged. In shielded organs at risk the deviations can mount to about 3%, depending on the film batch. In conclusion, radiographic film is a suitable detector for characterizing IM beams in a plane at reference depth.

Dose-Response Relationship, Radiation↗

Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations.

Head-and-neck tumors are often situated at an air-tissue interface what may result in an underdosage of part of the tumor in radiotherapy treatments using megavoltage photons, especially for small fields. In addition to effects of transient electronic disequilibrium, for these small fields, an increased lateral electron range in air will result in an important extra reduction of the central axis dose beyond the cavity. Therefore dose calculation algorithms need to model electron transport accurately. We simulated the trachea by a 2 cm diameter cylindrical air cavity with the rim situated 2 cm beneath the phantom surface. A 6 MV photon beam from an Elekta SLiplus linear accelerator, equipped with the standard multileaf collimator (MLC), was assessed. A 10 x 2 cm2 and a 10 x 1 cm2 field, both widthwise collimated by the MLC, were applied with their long side parallel to the cylinder axis. Central axis dose rebuild-up was studied. Radiochromic film measurements were performed in an in-house manufactured polystyrene phantom with the films oriented either along or perpendicular to the beam axis. Monte Carlo simulations were performed with BEAM and EGSnrc. Calculations were also performed using the pencil beam (PB) algorithm and the collapsed cone convolution (CCC) algorithm of Helax-TMS (MDS Nordion, Kanata, Cahada) version 6.0.2 and using the CCC algorithm of Pinnacle (ADAC Laboratories, Milpitas, CA, USA) version 4.2. A very good agreement between the film measurements and the Monte Carlo simulations was found. The CCC algorithms were not able to predict the interface dose accurately when lateral electronic disequilibrium occurs, but were shown to be a considerable improvement compared to the PB algorithm. The CCC algorithms overestimate the dose in the rebuild-up region. The interface dose was overestimated by a maximum of 31% or 54%, depending on the implementation of the CCC algorithm. At a depth of 1 mm, the maximum dose overestimation was 14% or 24%.

Air↗

Leaf position optimization for step-and-shoot IMRT.

PURPOSE: To describe the theoretical basis, the algorithm, and implementation of a tool that optimizes segment shapes and weights for step-and-shoot intensity-modulated radiation therapy delivered by multileaf collimators. METHODS AND MATERIALS: The tool, called SOWAT (Segment Outline and Weight Adapting Tool) is applied to a set of segments, segment weights, and corresponding dose distribution, computed by an external dose computation engine. SOWAT evaluates the effects of changing the position of each collimating leaf of each segment on an objective function, as follows. Changing a leaf position causes a change in the segment-specific dose matrix, which is calculated by a fast dose computation algorithm. A weighted sum of all segment-specific dose matrices provides the dose distribution and allows computation of the value of the objective function. Only leaf position changes that comply with the multileaf collimator constraints are evaluated. Leaf position changes that tend to decrease the value of the objective function are retained. After several possible positions have been evaluated for all collimating leaves of all segments, an external dose engine recomputes the dose distribution, based on the adapted leaf positions and weights. The plan is evaluated. If the plan is accepted, a segment sequencer is used to make the prescription files for the treatment machine. Otherwise, the user can restart SOWAT using the new set of segments, segment weights, and corresponding dose distribution. The implementation was illustrated using two example cases. The first example is a T1N0M0 supraglottic cancer case that was distributed as a multicenter planning exercise by investigators from Rotterdam, The Netherlands. The exercise involved a two-phase plan. Phase 1 involved the delivery of 46 Gy to a concave-shaped planning target volume (PTV) consisting of the primary tumor volume and the elective lymph nodal regions II-IV on both sides of the neck. Phase 2 involved a boost of 24 Gy to the primary tumor region only. SOWAT was applied to the Phase 1 plan. Parotid sparing was a planning goal. The second implementation example is an ethmoid sinus cancer case, planned with the intent of bilateral visus sparing. The median PTV prescription dose was 70 Gy with a maximum dose constraint to the optic pathway structures of 60 Gy. RESULTS: The initial set of segments, segment weights, and corresponding dose distribution were obtained, respectively, by an anatomy-based segmentation tool, a segment weight optimization tool, and a differential scatter-air ratio dose computation algorithm as external dose engine. For the supraglottic case, this resulted in a plan that proved to be comparable to the plans obtained at the other institutes by forward or inverse planning techniques. After using SOWAT, the minimum PTV dose and PTV dose homogeneity increased; the maximum dose to the spinal cord decreased from 38 Gy to 32 Gy. The left parotid mean dose decreased from 22 Gy to 19 Gy and the right parotid mean dose from 20 to 18 Gy. For the ethmoid sinus case, the target homogeneity increased by leaf position optimization, together with a better sparing of the optical tracts. CONCLUSIONS: By using SOWAT, the plans improved with respect to all plan evaluation end points. Compliance with the multileaf collimator constraints is guaranteed. The treatment delivery time remains almost unchanged, because no additional segments are created.

Humans↗

An anatomy-based beam segmentation tool for intensity-modulated radiation therapy and its application to head-and-neck cancer.

PURPOSE: In segmental intensity-modulated radiation therapy (IMRT), the beam fluences result from superposition of unmodulated beamlets (segments). In the inverse planning approach, segments are a result of ''clipping'' intensity maps. At Ghent University Hospital, segments are created by an anatomy-based segmentation tool (ABST). The objective of this report is to describe ABST. METHODS AND MATERIALS: For each beam direction, ABST generates segments by a multistep procedure. During the initial steps, beam's eye view (BEV) projections of the planning target volumes (PTVs) and organs at risk (OARs) are generated. These projections are used to make a segmentation grid with negative values across the expanded OAR projections and positive values elsewhere inside the expanded PTV projections. Outside these regions, grid values are set to zero. Subsequent steps transform the positive values of the segmentation grid to increase with decreasing distance to the OAR projections and to increase with longer pathlengths measured along rays from their entrance point through the skin contours to their respective grid point. The final steps involve selection of iso-value lines of the segmentation grid as segment outlines which are transformed to leaf and jaw positions of a multileaf collimator (MLC). Segment shape approximations, if imposed by MLC constraints, are done in a way that minimizes overlap between the expanded OAR projections and the segment aperture. RESULTS: The ABST procedure takes about 3 s/segment on a Compaq Alpha XP900 workstation. In IMRT planning problems with little complexity, such as laryngeal (example shown) or thyroid cancer, plans that are in accordance with the clinical protocol can be generated by weighting the segments generated by ABST without further optimization of their shapes. For complex IMRT plans such as paranasal sinus cancer (not shown), ABST generates a start assembly of segments from which the shapes and weights are further optimized. CONCLUSIONS: ABST is a fast procedure to generate a set of segments for IMRT planning. The plan is finalized by assigning weights to the segments or by direct optimization of segment shapes and weights. ABST allows us to avoid the step of translating optimized intensity maps to sequences of segments.

Algorithms↗

An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways.

PURPOSE: To develop a protocol for the irradiation of ethmoid sinus cancer, with the aim of sparing binocular vision; of developing a strategy of intensity-modulated radiation therapy (IMRT) planning that produces dose distributions that (1) are consistent with the protocol prescriptions and (2) are deliverable by static segmental IMRT techniques within a 15-minute time slot; of fine tuning the implementation strategy to a class solution approach that is sufficiently automated and efficient, allowing routine clinical application; of reporting on the early clinical implementation involving 11 patients between February 1999 and July 2000. patients and methods: Eleven consecutive T1-4N0M0 ethmoid sinus cancer patients were enrolled in the study. For Patients 1-8, a first protocol was implemented, defining a planning target volume prescription dose of 60 to 66 Gy in 30-33 fractions and a maximum dose (Dmax) of 50 Gy to optic pathway structures and spinal cord and limit of 60 Gy to brainstem. For Patients 9-11, an adapted (now considered mature) protocol was implemented, defining a (planning target volume) prescription dose of 70 Gy in 35 fractions and a Dmax to optic pathway structures and brainstem of 60 Gy and to spinal cord of 50 Gy. RESULTS: The class solution-directed strategy developed during this study reduced the protocol translation process from a few days to about 2 hours of planner time. The mature class solution involved the use of 7 beam incidences (20-37 segments), which could be delivered within a 15-minute time slot. Acute side effects were limited and mild. None of the patients developed dry eye syndrome or other visual disturbances. The follow-up period is too short for detection of retinopathy or optic nerve and chiasm toxicity. CONCLUSION: Conventional radiotherapy of ethmoid sinus tumors is associated with serious morbidity, including blindness. We hypothesize that IMRT has the potential to save binocular vision. The dose to the optic pathway structures can be reduced selectively by IMRT. Further enrollment of patients and longer follow-up will show whether the level of reduction tested by the clinical protocol is sufficient to save binocular vision. An adaptive strategy of IMRT planning was too inefficient for routine clinical practice. A class solution-directed strategy improved efficiency by eliminating human trial and error during the IMRT planning process.

Adenocarcinoma↗

Combining the advantages of step-and-shoot and dynamic delivery of intensity-modulated radiotherapy by interrupted dynamic sequences.

PURPOSE: A hybrid between step-and-shoot and dynamic operation, called interrupted dynamic sequences, was investigated for prostate intensity-modulated radiotherapy (IMRT) delivered by a multisegment close-in technique. The new delivery mode was compared to the step-and-shoot mode concerning dose distribution. METHODS AND MATERIALS: Segments suitable for dynamic transition were selected using a system of segment classes. Transitions were only allowed between two segments of the same class, keeping intended sharp in-field dose gradients unchanged. Delivery was performed by an Elekta SLiplus (Crawley, UK) linear accelerator equipped with a dynamic multileaf collimator (MLC). Because no modeling of the dose during the transitions is made, accurate dose measurements were performed. Dose profiles were measured using a linear ion chamber array (LA48, PTW-Freiburg). The suitability of this detector for measurements in sharp dose gradients was investigated first. In addition, field flatness was examined for segments with a low monitor unit (MU) count. Uncertainties in dose output were investigated using an ionization chamber (30001, PTW-Freiburg). RESULTS: Because linear array measured penumbrae are only slightly broader (< or = 0.4 mm for MLC collimated field) than those obtained using a diamond detector, the array is a good device for profile measurements. Uncertainties related with the use of low MU beam segments are very small (< 1% for segments of minimum 3 MU), giving no contra-evidence for the step-and-shoot mode. Interrupted dynamic sequences are shown to introduce only small dosimetric differences as compared to the step-and-shoot delivery. CONCLUSION: Both delivery modes, step-and-shoot and interrupted dynamic sequences, result in similar dose distributions for the forward planned prostate class solution.

Humans↗

Evaluation of a leaf position optimization tool for intensity modulated radiation therapy of head and neck cancer.

BACKGROUND AND PURPOSE: Since 1996, patients are treated at Ghent University Hospital with a multi-segment technique using MultiLeaf Collimators. The segments were obtained by using the Beam's eye view projections of the planning target volume (PTV) and the organs at risk (OARs), after which the segments weights were optimized. To investigate if optimization of the leaf positions would further improve the intensity modulated radiation therapy (IMRT) plans, a tool optimizing leaf positions and segment weights simultaneously, was developed. This tool is called SOWAT, which is the acronym for segment outline and weight adapting tool. MATERIAL AND METHODS: The tool evaluates the effects of changing the position of each collimating leaf of all segments on the value of the objective function. Only changes that improve the value of the objective function are retained. Between December 1999 and January 2001, 30 head and neck patients were treated with IMRT. Two patient groups were distinguished: pharyngeal and laryngeal tumors (n=17) and sinonasal tumors (n=13). A specific set of physical endpoints was evaluated for each group. Dose statistics of the treatment plans without and with SOWAT were analyzed. RESULTS: When using SOWAT for the pharyngeal and laryngeal cases, the PTV dose homogeneity increased with a median of 11% (range 2-27%), while the maximum dose to the spinal cord was decreased for 14 of the 17 patients. In four plans where parotid function preservation was a goal, the parotid mean dose was lower than 26 Gy in one plan without SOWAT, and in four plans with SOWAT. For the sinonasal tumors, the PTV dose homogeneity increased with a median of 7% (range 1-14%). SOWAT lowered the mean dose to 53 of the 63 optic pathway structures (retina, optic nerve and optic chiasm). SOWAT leaves the number of segments unchanged and has little or no effect on the delivery time. CONCLUSIONS: SOWAT is a powerful tool to perform the final optimization of IMRT plans, without increasing the complexity of the plan or the delivery time.

Algorithms↗

An isocenter position verification device for electronic portal imaging: physical and dosimetrical characteristics.

The physical and dosimetrical characteristics of a device, designed to visualize the isocenter position on electronic portal images, were examined. The device, to be mounted on the gantry head of the accelerator, containing five spheric lead markers, was designed in order to visualize the isocenter position on portal images. A quality control device was designed to check the reliability of this technique. The disturbance of the dose distribution by the markers was studied with gel dosimetry. The use of markers resulted in a precise and accurate method to visualize the isocenter on portal images. A maximum underdosage of 11%, due to attenuation by the markers, was observed. The use of markers to visualize the isocenter position on portal images, is a fast and reliable method when analyzing patient setup errors with online electronic portal imaging.

Diagnostic Imaging↗

Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning.

In high-precision 3D gel dosimetry, long MR measurement times together with a high amount of RF energy being absorbed by the phantom are very common, and result in a spatially dependent temperature rise in the gel. As T2 of the dosimeter gel is temperature dependent, dose estimation will be affected. In this study we assess the temperature rise in the dosimeter gel by use of MR temperature mapping and computer modelling. It is shown that in conventional MR sequences. where linear k-space sampling is used, a temperature rise of 3 C results in a dose underestimation of 10% over the whole dose map. To correct for these dose errors, a compensation method involving centric k-space ordering is suggested. Computer simulations have been performed to analyse the robustness of the proposed method. Applying the compensated sequence, a temperature rise of 3 C leads to a narrow dose artefact of the order of 3% for a 'worst case' situation in which a single pixel dose gradient is assumed. Negligible deviations are found in the rest of the dose map.

Acrylamide↗

On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source.

The aim of this work was to investigate the applicability of MR-based polymer gel dosimetry to measure the absorbed dose distribution at short distance from an iridium-192 brachytherapy point source. In this paper, different methodological problems that may result in significant errors in the measured dose distribution are discussed. First of all the extent to which physicochemical mechanisms alter the dose response is discussed. The most important among these are the oxygen permeability of the catheter material and monomer-diffusion-related effects during irradiation. The effect of oxygen on the dose-R2 curve has been determined quantitatively and an oxygen map is performed using a well-defined external irradiation beam. The effect of diffusion of monomer during irradiation has been simulated. Another contribution of errors is related to magnetic susceptibility differences between the catheter and the gel during scanning the irradiated gel. The magnetic field distortion has been mapped by using both an experimental MRI technique and by simulation. Moreover, in constructing a dose-versus-distance curve by polar averaging, the sensitivity to the exact distance between source and point of measurement and to partial volume effects is illustrated. An optimization program is proposed to determine the location of the source on a sub-pixel scale.

Acrylamide↗

The value of the LA48 linear ion chamber array for characterization of intensity-modulated beams.

In this paper the performance of the LA48 linear ion chamber array (PTW, Freiburg, Germany) for characterization of intensity-modulated (IM) beams was investigated. First, some elementary properties were explored. A series of beam penumbras and output factors for small rectangular fields were measured at 6 and 18 MV, and the results were compared with data obtained using a diamond detector. The energy and dose rate dependence of the array response were examined, and the leakage current was assessed. In a second step, profiles were measured for two clinically delivered IM beams and for a dynamic wedge. The interplay between the sharpening of the penumbra by the upper metal electrode plate of the array and the volume averaging of the 4 x 4 mm ion chamber elements results in precise measurements, even in regions of high dose gradient. It is true, however, that the metal electrodes imply a small energy spectrum dependence in the array response. The dose rate dependence is found to be negligible. All of this makes, the LA48 linear array a suitable device for analysing dose distributions of clinical IM beams.

Dose-Response Relationship, Radiation↗

Radiotherapy of prostate cancer with or without intensity modulated beams: a planning comparison.

PURPOSE: To evaluate whether intensity modulated radiotherapy (IMRT) by static segmented beams allows the dose to the main portion of the prostate target to escalate while keeping the maximal dose at the anterior rectal wall at 72 Gy. The value of such IMRT plans was analyzed by comparison with non-IMRT plans using the same beam incidences. METHODS AND MATERIALS: We performed a planning study on the CT data of 32 consecutive patients with localized adenocarcinoma of the prostate. Three fields in the transverse plane with gantry angles of 0 degrees, 116 degrees, and 244 degrees were isocentered at the center of gravity of the target volume (prostate and seminal vesicles). The geometry of the beams was determined by beam's eye view autocontouring of the target volume with a margin of 1.5 cm. In study 1, the beam weights were determined by a human planner (3D-man) or by computer optimization using a biological objective function with (3D-optim-lim) or without (3D-optim-unlim) a physical term to limit target dose inhomogeneity. In study 2, the 3 beam incidences mentioned above were used and in-field uniform segments were added to allow IMRT. Plans with (IMRT-lim) or without (IMRT-unlim) constraints on target dose inhomogeneity were compared. In the IMRT-lim plan, target dose inhomogeneity was constrained between 15% and 20%. After optimization, plans in both studies were normalized to a maximal rectal dose of 72 Gy. Biological (tumor control probability [TCP], normal tissue complication probability [NTCP]) and physical indices for tumor control and normal tissue complication probabilities were computed, as well as the probability of the uncomplicated local control (P+). RESULTS: The IMRT-lim plan was superior to all other plans concerning TCP (p < 0.0001). The IMRT-unlim plan had the worst TCP. Within the 3D plans, the 3D-optim-unlim had the best TCP, which was significantly different from the 3D-optim-lim plan (p = 0.0003). For rectal NTCP, both IMRT plans were superior to all other plans (p < 0.0001). The IMRT-unlim plan was significantly better than the IMRT-lim plan (p < 0.0001). Again, 3D-optim-unlim was superior to the other 3D plans (p < 0. 0007). Physical endpoints for target showed the mean minimal target dose to be the lowest in the IMRT-unlim plan, caused by a large target dose inhomogeneity (TDI). Medial target dose, 90th percentile, and maximal target dose were significantly higher in both IMRT plans. Physical endpoints for the rectum showed the IMRT-unlim plan to be superior compared to all other plans. There was a strong correlation between the 65th percentile (Rp65) and rectal NTCP (correlation coefficient > or =89%). For bladder, maximal bladder dose was significantly higher in the IMRT-unlim plan compared to all other plans (p < or = 0.0001).P+ was significantly higher in both IMRT-plans than in all other plans. The 3D-optim-unlim plan was significantly better than the two other 3D plans (p < 0.0001). CONCLUSION: IMRT significantly increases the ratio of TCP over NTCP of the rectum in the treatment of prostate cancer. However, constraints for TDI are needed, because a high degree of TDI reduced minimal target dose. IMRT improved uncomplicated local control probability. In our department, IMRT by static segmented beams is planned and delivered in a cost-effective way. IMRT-lim has replaced non-modulated conformal radiotherapy as the standard treatment for prostate cancer.

Adenocarcinoma↗

Optimization of beam weights in conformal radiotherapy planning of stage III non-small cell lung cancer: effects on therapeutic ratio.

PURPOSE: To evaluate the effects of beam weight optimization for 3D conformal radiotherapy plans, with or without beam intensity modulation, in Stage III non-small cell lung cancer (NSCLC). METHODS AND MATERIALS: Ten patients with Stage III NSCLC were planned using a conventional 3D technique and a technique involving noncoplanar beam intensity modulation (BIM). Two planning target volumes (PTVs) were defined: PTV1 included macroscopic tumor volume and PTV2 included macroscopic and microscopic tumor volume. Virtual simulation defined the beam shapes and incidences as well as the wedge orientations (3D) and segment outlines (BIM). Weights of wedged beams, unwedged beams, and segments were determined by human trial and error for the 3D-plans (3D-manual), by a standard weight table (SWT) for the BIM-plans (BIM-SWT) and by optimization (3D-optimized and BIM-optimized) using an objective function with a biological and a physical component. The resulting non-optimized and optimized dose distributions were compared, using physical endpoints, after normalizing the median dose of PTV1 to 80 Gy. RESULTS: Optimization improved dose homogeneity at the target for 3D- and BIM-plans and the minimum dose at PTV1. The minimum dose at PTV2 was decreased by optimization especially in 3D-plans. After optimization, the dose-volume histograms (DVHs) of lung and heart were shifted to lower doses for 80-90% of the organ volume. Since lung is the dose-limiting organ in Stage III NSCLC, an increased minimum dose at PTV1 together with a decreased dose at the main lung volume suggests an improved therapeutic ratio. Optimization allows 10% dose escalation for 3D-plans and 20% for BIM-plans at isotoxicity levels of lung and spinal cord. Upon dose escalation, esophagus may become the dose-limiting structure when PTV1 extends close to the esophagus. CONCLUSIONS: Optimization using a biophysical objective function allowed an increase of the therapeutic ratio of radiotherapy planning for Stage III NSCLC.

Algorithms↗

Validation of MR-based polymer gel dosimetry as a preclinical three-dimensional verification tool in conformal radiotherapy.

The aim of this work was to investigate MR-based polymer gel dosimetry as a three-dimensional (3D) dosimetry technique in conformal radiotherapy. A cylindrical container filled with polymer gel was placed in a water-filled torso phantom to verify a treatment plan for the conformal irradiation of a mediastinal tumor located near the esophagus. Magnetic resonance spin-spin relaxation rate images were acquired and, after calibration, converted to absorbed dose distributions. The dose maps were compared with dose distributions measured using radiographic film. The average root-mean-square structural deviation, for the complete dose distribution, amounted to less than 3% between gel and film dose maps. It may be expected that MR gel dosimetry will become a valuable tool in the verification of 3D dose distributions. The influence of imaging artifacts arising from eddy currents, temperature drift during scanning, and B1 field inhomogeneity on the dose maps was taken into account and minimized.

Acrylamide↗