Search PubMed⌕ Search

Biomedical subjects

C D Gottlieb

Publications and source records attributed to C D Gottlieb.

At least 19 recordsLinked to original sources

Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy.

BACKGROUND: Conventional activation mapping is difficult without inducible, stable ventricular tachycardia (VT). METHODS AND RESULTS: We evaluated 16 patients with drug refractory, unimorphic, unmappable VT. Nine patients had ischemic and 7 had nonischemic cardiomyopathy. All patients had implantable defibrillators and had experienced 6 to 55 VT episodes during the month before treatment. Patients underwent bipolar catheter mapping during baseline rhythm. The amount of endocardium with an abnormal electrogram amplitude was estimated using fluoroscopy in 3 patients and a magnetic mapping system (CARTO) in 13 patients. For the magnetic mapping, normal endocardium was defined by an amplitude >1.5 mV; this measurement was based on sinus rhythm maps in 6 patients who did not have structural heart disease. Radiofrequency point lesions extended linearly from the "dense scar," which had a voltage amplitude <0.5 mV, to anatomic boundaries or normal endocardium. To limit radiofrequency applications, 12-lead ECG during VT and pacemapping guided placement of linear lesions. No new antiarrhythmic drug therapy was added. The amount of endocardium demonstrating an abnormal electrogram amplitude ranged from 25 to 127 cm(2). A total of 8 to 87 radiofrequency lesions (mean, 55) produced a median of 4 linear lesions that had an average length of 3.9 cm (range, 1.4 to 9. 4 cm). Twelve patients (75%) have been free of VT during 3 to 36 months of follow-up (median, 8 months); 4 patients had VT episodes at 1, 3, 9, and 13 months, respectively. Only one of these patient had frequent VT. CONCLUSIONS: Radiofrequency linear endocardial lesions extending from the dense scar to the normal myocardium or anatomic boundary seem effective in controlling unmappable VT.

Adult↗

Efficacy and safety of catheter ablation in octogenarians.

OBJECTIVES: To determine whether catheter ablation is safe and effective in patients over the age of 80. BACKGROUND: There is a tendency to withhold invasive therapy in the elderly until it has been proven safe and effective. METHODS: Over a two-year period from February 1, 1996 to February 1, 1998, 695 consecutive patients underwent 744 catheter ablation procedures of supraventricular and ventricular arrhythmias. These patients were divided into three groups based on age: > or =80 years, 60 to 79 years and <60 years. Acute ablation success, using standard criteria and complication rates for these three groups were determined. RESULTS: There were 37 patients > or =80 years, 275 patients 60 to 79 years and 383 patients <60 years old. The overall acute ablation success rate for the entire group was 95% with no difference in rates among the three groups (97%, > or =80 years; 94%, 60-79 years; 95%, <60 years). The percentage of patients undergoing His bundle ablation was greatest in the > or =80-year-old group (43% vs. 19% vs. 2%, p < 0.01), and the percentage of patients undergoing accessory pathway ablation was greatest in the <60-year-old patients (0% vs. 4% vs. 25%, p < 0.01). The overall complication rate for the entire group was 2.6%, and there was only one major/life-threatening complication. There was no difference in complication rates among the groups (0%, > or =80 years; 2.2%, 60 to 79 years; 3.1%, <60 years). Based on the sample size, the 95% confidence interval is 0% to 7.8% for an adverse event in the octogenarian. CONCLUSIONS: Catheter ablative therapy for the arrhythmias attempted in the very elderly appears to be effective with low risk. Ablation results appear to be comparable with those noted in younger patients.

Aged↗

Accuracy of fluoroscopic localization of the Crista terminalis documented by intracardiac echocardiography.

The crista terminalis is an important anatomic target for ablation of atrial arrhythmias. We determined the accuracy of catheter placement guided by fluoroscopy alone when directed to 24 sites along the crista terminalis in 6 patients. The sites selected included the most medial superior, most lateral superior, mid lateral, and most inferolateral sites along the crista terminalis in each patient. These sites were selected because of their recognized importance in sinus node and/or atrial tachycardia ablation and the importance of avoiding caval structures when targeting the most superior and/or inferior right atrium. The position of the catheter tip was documented using a catheter based ultrasound transducer in the right atrium or vena cava. The operator was blinded to the intracardiac echocardiographic (ICE) results until reviewing the images after the procedure in each patient. The catheter tip, guided by fluoroscopy alone, was identified by ICE to be within the right atrium and within 1cm of the crista terminalis at only 10 of the 24 sites (42%). Importantly, when targeting the most superior and inferior sites along the crista terminalis, the catheter tip, guided by fluoroscopy, was noted to be adjacent to the venous junction with the right atrium but actually located in the superior or inferior vena cava at 5 of the 18 such sites. The catheter was positioned appropriately (within 1 cm of the crista and within the right atrium) guided by fluoroscopy alone when targeting 1 of the 12 sites in the first 3 patients versus 9 of 12 sites in the last 3 patients, p<0.05. In conclusion, it appears that using fluoroscopic guidance alone: 1) localization of the crista terminalis is frequently inaccurate and 2) catheter positioning in the superior/inferior vena cava is commonly noted when targeting very superior and inferior sites along the crista terminalis. A learning curve, assisted by review of ICE recordings after each procedure, appears to improve the accuracy of catheter placement by fluoroscopy alone but still does not result in uniform success. ICE appears to facilitate and ensure accurate targeting of specific anatomic sites along the crista terminalis and thus may serve as an important adjunctive imaging technique in electrophysiology.

Adult↗

Electroanatomic magnetic mapping during ablation of isthmus-dependent atrial flutter.

INTRODUCTION: Although recent studies have demonstrated that the endpoint of isthmus conduction block is superior to that of termination and subsequent inability to induce atrial flutter (AFl), the optimal method for determining isthmus conduction block has not been determined. Electroanatomic magnetic mapping during coronary sinus (CS) pacing may provide a reliable endpoint for AFl ablation. METHODS AND RESULTS: Catheter mapping and ablation was performed in 42 patients with isthmus-dependent AFl. The patients were divided into two groups, based on procedural endpoint: Group I (28 patients) - isthmus conduction block was determined based on multipolar catheter recordings and electroanatomic mapping, and Group II (14 patients) - isthmus conduction block was determined by electroanatomic mapping during CS pacing alone. In Group I, ablation procedures were acutely successful in 25 of 28 patients (89 %). A 100 % concordance between the data presented by multipolar catheter recordings and electroanatomic mapping was noted in determining the presence or absence of isthmus conduction block. In Group II, ablation procedures were acutely successful in 13 of 14 patients, 13 (93 %). After a mean of 16.3+/-3.7 months follow up, there was 1 atrial flutter recurrence in the 38 patients (2.6 %) with demonstrated isthmus block at the end of the procedure. CONCLUSIONS: Electroanatomic magnetic mapping during CS pacing is comparable to the multipolar catheter mapping technique for assessing isthmus conduction block as an endpoint for AFl ablation procedures.

Adult↗

Using intracardiac catheter recordings from the His and proximal coronary sinus to distinguish isthmus conduction block during catheter ablation of type I atrial flutter.

Isthmus conduction block, demonstrated with the use of multipolar catheter recordings, is considered the preferred endpoint for ablation of type I atrial flutter. This study investigated the feasibility of using recordings from the His and coronary sinus (CS) to document isthmus conduction block. Isthmus conduction block was produced with linear radiofrequency (RF) ablation in 27 patients with type I atrial flutter. In 13 patients (group I), RF was delivered until bidirectional isthmus conduction block was demonstrated with multipolar Halo catheter recordings. In 14 patients (group II), RF was delivered during pacing from the lateral isthmus at 600 ms until a reversal in activation of the proximal CS and His occurred. At this point, data from the Halo recordings were reviewed to see if reversal correlated with conduction block; if not, further ablation was performed until block was demonstrated. The initial reversal in His and CS activation during RF energy delivery correlated with isthmus block in only 4 (28.6%) of 14 patients in group II. Additional RF delivery produced isthmus block in the other ten patients resulting in a further increase in the St-CS interval of 35 +/- 20 ms. A His-CS interval of at least -40 ms signified isthmus block with a sensitivity and specificity of 48% and 100%, respectively. Reversal in His-CS activation during pacing from the lateral margin of the isthmus is not specific for the creation of isthmus block. While activation of the proximal CS bipole > 40 ms after activation of the His appears specific for isthmus block, the low sensitivity of this finding limits its clinical use.

Atrial Flutter↗

Mechanisms of death in the CABG Patch trial: a randomized trial of implantable cardiac defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery.

BACKGROUND: The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery patients who had a left ventricular ejection fraction <0.36 and an abnormal signal-averaged ECG. There were 102 deaths among the 446 ICD group patients and 96 deaths among the 454 control group patients, a hazard ratio of 1.07 (P=0.63). The mechanisms of death were classified, and hypotheses were tested about the effects of ICD therapy on arrhythmic and nonarrhythmic cardiac deaths in the CABG Patch Trial and the Multicenter Automatic Defibrillator Implantation Trial (MADIT). METHODS AND RESULTS: The 198 deaths in the trial were reviewed by an independent Events Committee and classified by the method of Hinkle and Thaler. Only 54 deaths (27%) occurred out of hospital; 145 deaths (73%) were witnessed. Seventy-nine (82%) of the 96 deaths in the control group and 76 (75%) of the 102 deaths in the ICD group were due to cardiac causes. Cumulative arrhythmic mortality at 42 months was 6.9% in the control group and 4.0% in the ICD group (P=0. 057). Cumulative nonarrhythmic cardiac mortality at 42 months was 12. 4% in the control group and 13.0% in the ICD group (P=0.275). Death due to pump failure was significantly associated with death >1 hour from the onset of symptoms, dyspnea within 7 days of death, and overt heart failure within 7 days of death. CONCLUSIONS: In the CABG Patch Trial, ICD therapy reduced arrhythmic death 45% without significant effect on nonarrhythmic deaths. Because 71% of the deaths were nonarrhythmic, total mortality was not significantly reduced.

Anti-Arrhythmia Agents↗

Intracardiac echocardiography (9 MHz) in humans: methods, imaging views and clinical utility.

A new low-frequency (9 MHz, 9 Fr) catheter-based ultrasound (US) transducer has been designed that allows greater depth of cardiac imaging. To demonstrate the imaging capability and clinical utility, intracardiac echocardiography (ICE) using this lower frequency catheter was performed in 56 patients undergoing invasive electrophysiological procedures. Cardiac imaging and monitoring were performed with the catheter transducer placed in the superior vena cava (SVC), right atrium (RA) and/or right ventricle (RV). In all patients, ICE identified distinct endocardial structures with excellent resolution and detail, including the crista terminalis, RA appendage, caval and coronary sinus orifices, fossa ovalis, pulmonary vein orifices, ascending aorta and its root, pulmonary artery, RV and all cardiac valves. The left atrium and ventricle were imaged with the transducer at the limbus fossa ovalis of the interatrial septum and in the RV, respectively. ICE was important in identifying known or unanticipated aberrant anatomy in 11 patients (variant Eustachian valve, atrial septal aneurysm and defect, lipomatous hypertrophy, Ebstein's anomaly, ventricular septal defect, tetralogy of Fallot, transposition of the great arteries, disrupted chordae tendinae and pericardial effusion) or in detecting procedure-related abnormalities (narrowing of SVC-RA junction orifice or pulmonary venous lumen, atrial thrombus, interatrial communication). In patients with inappropriate sinus tachycardia, ICE was the primary ablation catheter-guidance technique for sinus node modification. With ICE monitoring, the evolution of lesion morphology with the three imaging features including swelling, dimpling and crater formation was observed. In all patients, ICE was contributory to the mapping and ablation process by guiding catheters to anatomically distinct sites and/or assessing stability of the electrode-endocardial contact. ICE was also used to successfully guide atrial septal puncture (n = 9) or RA basket catheter placement (n = 4). Thus, ICE with a new 9-MHz catheter-based transducer has better imaging capability with a greater depth. Normal and abnormal cardiac anatomy can be readily identified. ICE proved useful during electrophysiological mapping and ablation procedures for guiding interatrial septal puncture, assessing placement and contact of mapping and ablation catheters, monitoring ablation lesion morphological changes, and instantly diagnosing cardiac complications.

Adult↗

Narrowing of the superior vena cava-right atrium junction during radiofrequency catheter ablation for inappropriate sinus tachycardia: analysis with intracardiac echocardiography.

OBJECTIVES: The study explored the potential for tissue swelling and venous occlusion during radiofrequency (RF) catheter ablation procedures using intracardiac echocardiography (ICE). BACKGROUND: Transient superior vena cava occlusion has been reported following catheter ablation procedures for inappropriate sinus tachycardia (IST). Presumably, venous occlusion could occur owing to thrombus formation or tissue swelling with resultant narrowing of the superior vena cava-right atrial (SVC-RA) junction. METHODS: Intracardiac echocardiography (9 MHz) was used to guide ablation catheter position and for continuous monitoring during RF application in 13 ablation procedures in 10 patients with IST. The SVC-RA junction was measured prior to and following ablation. Successful ablation was marked by abrupt reduction in the sinus rate and a change to a superiorly directed p-wave axis. RESULTS: Eleven of 13 procedures were successful, requiring 29 +/- 20 RF lesions. Prior to the delivery of RF lesions, the SVC-RA junction measured 16.4 +/- 2.9 mm. With RF delivery, local and circumferential swelling was observed, causing progressive reduction in the diameter of the SVC-RA junction to 12.6 +/- 3.3 mm (24% reduction, p = 0.0001). A reduction in SVC-RA orifice diameter of > or = 30% compared to baseline was observed in five patients. CONCLUSIONS: The delivery of multiple RF ablation lesions, often necessary for cure of IST, can cause considerable atrial swelling and resultant narrowing of the SVC-RA junction. Smaller venous structures, such as the coronary sinus and the pulmonary veins, would also be expected to be vulnerable to this complication. Thus, ICE imaging may be helpful in preventing excessive tissue swelling leading to venous occlusion during catheter ablation procedures.

Adult↗

Antidromic reciprocating tachycardia in patients with paraseptal accessory pathways: importance of critical delay in the reentry circuit.

Previous studies in patients with antidromic reciprocating tachycardia (ART) have observed a critical anatomic requirement (> 4 cm) between an antegrade bypass tract limb and a retrograde AV nodal limb. We report two patients with ART utilizing a paraseptal accessory pathway. In both cases, a critical degree of slow conduction within the circuit provides unusual electrophysiologic substrate to overcome the expected anatomical constraints.

Adult↗

Imaging technique and clinical utility for electrophysiologic procedures of lower frequency (9 MHz) intracardiac echocardiography.

Intracardiac echocardiography using a new 9-MHz ultrasound catheter was performed in 30 patients undergoing percutaneous catheter mapping and radiofrequency ablation of a tachyarrhythmia, because the imaging capabilities with this intracardiac echocardiographic catheter permit detailed identification of normal and abnormal cardiac anatomy with improved imaging depth. Intracardiac echocardiography is of significant clinical utility during ablation for guiding interatrial septal puncture, assessing placement and contact of mapping/ablation catheters, monitoring ablation lesion morphologic changes, and diagnosing procedure-related complications.

Adult↗

Efficacy of radiofrequency catheter ablation for ventricular tachycardia in healed myocardial infarction.

Radiofrequency catheter ablation has been useful in the treatment of ventricular tachycardia (VT) in selected patients with healed myocardial infarction. Previous studies have demonstrated success rates of 60% to 96% for targeted VT morphologies; however, these studies included patients only after they have had successful mapping procedures and have received radiofrequency lesions. All patients referred for VT ablation from July 1992 to November 1996 were included in this analysis on an intention-to-treat basis. Ninety-five procedures were performed in 66 patients for 77 distinct presentations with tolerated, sustained VT. Fifty-five procedures were successful (58%) and 40 procedures failed. Reasons for procedural failure included failed radiofrequency application despite adequate VT mapping (21 procedures), no tolerated VT induced (12), and aborted procedures due to complications or technical difficulties (7). Fifty-five patients (71%) eventually had a successful VT ablation, although 10 required > 1 procedure. This analysis revealed factors that contribute to failure of VT ablation procedures in addition to inadequate mapping and lesion formation. Procedural difficulties, particularly the inability to induce tolerated VT, frequently prevent successful catheter ablation in patients who present with tolerated, sustained VT.

Aged↗

Type I atrial flutter ablation guided by a basket catheter.

Bidirectional isthmus conduction block has been associated with a low recurrence rate after atrial flutter ablation. We present the case of a type I, typical or "counterclockwise" atrial flutter ablation guided by stimulation and recordings obtained from a basket catheter, which allowed for constant electrogram recording from splines positioned along the right lateral free wall and septum. After atrial flutter termination with radiofrequency application, the ability to record and stimulate from multiple sites in the atrium using the basket catheter was useful to detect residual bidirectional slow conduction through the isthmus. Complete isthmus block could be documented after additional radiofrequency energy applications.

Aged↗

Prediction of outcome of patients with life-threatening ventricular arrhythmias treated with automatic implantable cardioverter-defibrillators using SPECT perfusion imaging.

BACKGROUND: In the present study, we examined the predictors of outcome of 103 patients with coronary artery disease and left ventricular dysfunction who had life-threatening ventricular arrhythmias and were treated with implantable cardioverter-defibrillators with the use of single-photon emission computed tomography (SPECT). METHODS AND RESULTS: During a mean follow-up of 29 months, there were 29 cardiac deaths. In comparison with patients who died, survivors had less diabetes mellitus (45% versus 19%, P < .007), higher left ventricular ejection fraction (23 +/- 9% versus 27 +/- 11%, P = .04), and fewer perfusion defects as determined with stress SPECT (15 +/- 5 versus 12 +/- 5, P < .004). Most of the perfusion defects were fixed, indicative of scarring; the extent of reversible defects did not differ (2 +/- 3 in survivors and 3 +/- 4 in nonsurvivors). Multivariate Cox survival analysis identified the number of fixed defects as the only independent predictor of death (chi 2 = 10, P = .002). There were six deaths among 42 patients (14%) with < 8 fixed defects compared with 23 deaths among 61 patients (38%) with > or = 8 defects (P = .005). The 4-year survival was better in patients with < 8 segmental fixed defects than in those with > or = 8 fixed defects (80% versus 36%) (chi 2 = 8, P = .005). CONCLUSIONS: The myocardial perfusion pattern is an important determinant of outcome in patients with life-threatening ventricular arrhythmias who are treated with a implantable cardioverter-defibrillator. The extent of scarring separates patients into high- and low-risk groups with a 2.7-fold difference in death rate.

Aged↗

Repetitive monomorphic tachycardia from the left ventricular outflow tract: electrocardiographic patterns consistent with a left ventricular site of origin.

OBJECTIVES: This study sought to characterize the electrocardiographic patterns predictive of left ventricular sites of origin of repetitive monomorphic ventricular tachycardia (RMVT). BACKGROUND: RMVT typically arises from the right ventricular outflow tract (RVOT) in patients without structural heart disease. The incidence of left ventricular sites of origin in this syndrome is unknown. METHODS: Detailed endocardial mapping of the RVOT was performed in 33 consecutive patients with RMVT during attempted radiofrequency ablation. Left ventricular mapping was also performed if pace maps obtained from the RVOT did not reproduce the configuration of the induced tachycardia. RESULTS: Pace maps identical in configuration to the induced tachycardia were obtained from the RVOT in 29 of 33 patients. Application of radiofrequency energy at sites guided by pace mapping resulted in elimination of RMVT in 24 (83%) of 29 patients. In four patients (12%), pace maps obtained from the RVOT did not match the induced tachycardia. All four patients had a QRS configuration during RMVT with precordial R wave transitions at or before lead V2. In two patients, RMVT was mapped to the mediosuperior aspect of the mitral valve annulus, near the left fibrous trigone; catheter ablation at that site was successful in both. In two patients, RMVT was mapped to the basal aspect of the superior left ventricular septum. Catheter ablation was not attempted because His bundle deflections were recorded from this site during sinus rhythm. CONCLUSIONS: RMVT can arise from the outflow tract of both the right and left ventricles. RMVTs with a precordial R wave transition at or before lead V2 are consistent with a left ventricular origin.

Adult↗

Characterization of the excitable gap in human type I atrial flutter.

OBJECTIVES: We sought to characterize the excitable gap of the reentrant circuit in atrial flutter. BACKGROUND: The electrophysiologic substrate of typical atrial flutter has not been well characterized. Specifically, it is not known whether the properties of the tricuspid valve isthmus differ from those of the remainder of the circuit. METHODS: Resetting was performed from two sites within the circuit: proximal (site A) and distal (site B) to the isthmus in 14 patients with type I atrial flutter. Resetting response patterns and the location where interval-dependent conduction slowing occurred were assessed. RESULTS: Some duration of a flat resetting response (mean +/- SD 40.1 +/- 20.9 ms, 16 +/- 8% of the cycle length) was observed in 13 of 14 patients; 1 patient had a purely increasing response. During the increasing portion of the resetting curve, interval-dependent conduction delay most commonly occurred in the isthmus. In most cases, the resetting response was similar at both sites. In three patients, the resetting response differed significantly between the two sites; this finding suggests that paced beats may transiently change conduction within the circuit or the circuit path, or both. CONCLUSIONS: Some duration of a flat resetting response was observed in most cases of type I atrial flutter, signifying a fully excitable gap in all portions of the circuit. The isthmus represents the portion of the circuit most vulnerable to interval-dependent conduction delay at short coupling intervals.

Action Potentials↗

Right ventricular radiofrequency ablation of ventricular tachycardia after myocardial infarction.

Radiofrequency transcatheter ablation of ventricular tachycardia in the setting of a prior myocardial infarction is typically performed with application of energy to the left ventricular endocardium. In this article, two cases are described in which successful radiofrequency transcatheter ablation of ventricular tachycardia occurred with energy delivery to the right ventricular septum after failed ablation attempts from the left ventricle. Both patients had tachycardias with a left bundle branch block morphology and markedly presystolic activity recorded from the right ventricular septum. Right ventricular septal activation mapping during ventricular tachycardia should be performed in patients with left bundle branch block tachycardia morphology and coronary artery disease to maximize efficacy of the catheter ablation procedure.

Aged↗

Does the initial presentation of patients with implantable defibrillator influence the outcome?

The influence of the clinical presentation on the long-term outcome in 213 consecutive patients with ICDs, ECG storage capability, and nonthoracotomy leads, was analyzed. Sixty-six patients presented with cardiac arrest (CA), 81 patients with hemodynamically stable VT, and 66 patients with syncope (SY). Patient characteristics were: mean age CA 62, VT 61, SY 61 years; mean ejection fraction CA 31%, VT 29%, SY 30%; coronary artery disease CA 71%, VT 71%, SY 64% (all P > 0.05 Fisher's exact test); female gender CA 40%, VT 14%, SY 19% (CA vs VT and SY, P < 0.005); inducibility by programmed stimulation CA 50%, VT 84%, SY 61% (VT vs CA and SY, P < 0.001, CA vs SY, P > 0.05). During a mean follow-up of 14.5 months, 29 patients died: CA 12%, VT 14%, SY 9% (P > 0.05). Comparing Kaplan-Meier curves, no difference in the time course of overall mortality was found (log-rank P > 0.05). In the CA, VT, and SY groups, 543, 1,630, and 189 ICD therapies (including antitachycardia pacing, low energy cardioversion, and defibrillation) were observed, respectively. Actuarial analysis showed a shorter interval between implantation and first ICD therapy for VT versus CA and SY (log-rank P < 0.005). Patients presenting with VT experienced earlier and more frequent ICD therapies than patients with CA or SY independent of age, ejection fraction, and heart disease. No difference in overall mortality and time course of fatal events was observed among the three groups.

Actuarial Analysis↗