Search PubMed⌕ Search

Biomedical subjects

C D Claussen

Publications and source records attributed to C D Claussen.

At least 127 records · Page 7Linked to original sources

Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.

OBJECTIVES: The aim of the present study was to evaluate the accuracy in determining coronary lesion configuration by multislice computed tomography (MSCT). The results were compared with the findings of intracoronary ultrasound (ICUS). BACKGROUND: The risk of acute coronary syndromes caused by plaque disruption and thrombosis depends on plaque composition rather than stenosis severity. Thus, the reliable noninvasive assessment of plaque configuration would constitute an important step forward for risk stratification in patients with known or suspected coronary artery disease. Just recently, MSCT scanners became available for general purpose scanning. Due to improved spatial and temporal resolution, this new technology holds promise to allow for differentiation of coronary lesion configuration. METHODS: The ICUS and MSCT scans (Somatom Volume Zoom, Siemens, Forchheim, Germany) were performed in 15 patients. Plaque composition was analyzed according to ICUS (plaque echogenity: soft, intermediate, calcified) and MSCT criteria (plaque density expressed by Hounsfield units [HU]). RESULTS: Thirty-four plaques were analyzed. With ICUS, the plaques were classified as soft (n = 12), intermediate (n = 5) and calcified (n = 17). Using MSCT, soft plaques had a density of 14 +/- 26 HU (range -42 to +47 HU), intermediate plaques of 91 +/- 21 HU (61 to 112 HU) and calcified plaques of 419 +/- 194 HU (126 to 736 HU). Nonparametric Kruskal-Wallis test revealed a significant difference of plaque density among the three groups (p < 0.0001). CONCLUSIONS: Our results indicate that coronary lesion configuration might be correctly differentiated by MSCT. Since also rupture-prone soft plaques can be detected by MSCT, this noninvasive method might become an important diagnostic tool for risk stratification in the near future.

Adult↗

Accuracy and reliability of quantitative measurements in coronary arteries by multi-slice computed tomography: experimental and initial clinical results.

AIM: To evaluate the accuracy of non-invasive measurements within coronary arteries by multi-slice computed tomography (MSCT). We present experimental as well as clinical data. MATERIALS AND METHODS: Silicon tubes simulating coronary arteries (outer diameter 6 mm, lumen diameter within stenotic area 2 mm) were used for experimental studies. Clinical data were derived from 15 patients in whom vessel diameters were assessed by MSCT, intracoronary ultrasound (ICUS) and quantitative coronary angiography (QCA). MSCT were performed in a Somatom Volume Zoom(trade mark)CT system (Siemens, Forchheim, Germany) at 2 collimated slice widths (2.5 mm, 1.0 mm). RESULTS: Outer silicon tube diameters were overestimated by MSCT (6.56 mm +/- 0.32 mm). All measurements revealed significantly better results on 1.0 collimation compared to 2.5 mm collimation (outer diameter: 6.36 mm +/- 0.22 mm vs 6.76 mm +/- 0.27 mm, P < 0.0001; lumen diameters: 1.83 mm +/- 0.14 mm vs 1.51 mm +/- 0.19 mm, P < 0.0001). The comparison of vessel diameters within human coronary arteries revealed comparable results between ICUS and MSCT (4.89 mm +/- 0.67 mm vs 4.91 mm +/- 0.71 mm, P = 0.79, r = 0.79, P < 0.0001). QCA-measurements showed significantly lower results (3.67 +/- 0.71, P < 0.0001, r = 0.62, P < 0.001). CONCLUSIONS: Experimental as well as initial clinical results indicate acceptable reliability and accuracy of quantitative measurements by MSCT, when using thin collimated slice widths. Partial volume effects lead to a systematic overestimation of vessel size. MSCT has the potential to become an important non-invasive diagnostic tool in patients with coronary artery disease.

Coronary Angiography↗

New strategies in platelet inhibition in noncoronary interventions.

Thrombembolic complications frequently occur during and after endovascular procedures because of associated arterial injury and thrombotic characteristics of implanted devices such as stents. New strategies in platelet aggregation inhibition are now available blocking the final and common pathway of platelet aggregation, the glycoprotein IIb/IIIa receptor. This treatment modality seems to be more effective for prophylaxis and prevention of thrombembolic complications than standard antiplatelet therapy. Most of the data provided for glycoprotein IIb/IIIa receptor blockade are derived from studies of coronary interventions. This report reviews the pharmacodynamic differences of classic and new drugs for platelet inhibition and the basic considerations for antiplatelet therapy in noncoronary interventions.

Arteries↗

[Can follow-up controls improve the accuracy of MR mammography? A retrospective analysis of MR mammography follow-up studies].

PURPOSE: To assess the change in diagnostic confidence between first and follow-up dynamic MR examination of the breast (MRM). METHODS: The reports of a total of 175 MRM in 77 patients (mean age 50 years; 36-76) with 98 follow-up MRM were analyzed. All examinations were performed as a dynamic study (Gd-DTPA, 0.16 mmol/kg; 6-7 repetitive studies). The change in diagnostic confidence was retrospectively classified as follows: controlled lesion vanished during follow-up (category I); diagnostic confidence increases during follow-up (II), more likely benign (IIa), more suspicious (IIb); no difference in diagnostic confidence (III). Long-term follow-up over an average of four years was obtained for 57 patients with category IIa/III findings. RESULTS: In 98 follow-up examinations, only two lesions vanished (2%). In 77/98 cases a category IIa lesion was diagnosed, in 11 cases a category IIb lesion. In 8 cases (8%) there was no change in diagnostic confidence during follow-up. Lesions in category IIb underwent biopsy in 10/11 cases, in one case long-term follow-up proved a completely regredient inflammatory change. In 8/11 suspicious findings (IIb) a malignant tumor was detected. The mean time interval between first and follow-up MRM was 8 months for I-IIb lesions, and 4 months for category III lesions. In the long-term follow-up two patients with a category IIa lesion developed a carcinoma in a different breast area after four and five years. CONCLUSION: MRM follow up increases the diagnostic confidence if the time interval is adequate (> 4 months). A persistently or increasingly suspicious finding warrants biopsy.

Adult↗

[MR tomographic characterization of suspicious breast lesions with dynamic susceptibility-weighted T2* sequences].

PURPOSE: To increase specificity of MR-mammography by using dynamic T2* sequences. METHODS: 23 patients with suspicious lesions of the breast underwent conventional dynamic T1-weighted (T1-dynamic) breast MRI and, subsequently, dynamic T2*-weighted (T2*-dynamic) perfusion studies. To assess the T1-dynamic, signal enhancement during the first minute (E1) was calculated. To evaluate the T2*-dynamic, relative signal intensity loss after administration of contrast medium was determined. RESULTS: After administration of contrast medium, 6 of 13 malignant lesions did not show a signal decrease during the T2*-dynamic. Two of them exhibited an atypical signal enhancement in the T1-dynamic, with E1 < 100%. On the other hand, in 5 of 10 benign tumors a relative signal decrease of between 5-17% occurred during the T2*-dynamic. Four benign lesions showed a strong early signal enhancement during the T1-dynamic (E1 > 100%), which is more typical for malignant lesions. DISCUSSION: The use of dynamic T2* sequences, following dynamic T1-weighted breast MRI and administration of contrast medium, does not sufficiently increase diagnostic sensitivity. Thus, this study does not support the potential advantage of susceptibility MR imaging for a further characterization of breast lesions.

Adult↗

[Use of VR (virtual reality) software for preoperative implantation fitting with an implantable hearing aid as an example].

PURPOSE: To prove the feasibility of a preoperative fitting test for an implantable hearing aid using a VR environment. METHODS: A high-resolution spiral CT was performed after mastoidectomy in 10 temporal bone specimens. The bony structures were segmented and merged with the Computer-Aided Design (CAD) data of the hearing aid in a VR environment. For each specimen a three-dimensional fitting test was carried out by three examiners determining the implantability of the hearing aid. The implantation simulation was compared with the real implantation procedure performed by an experienced ENT surgeon. RESULTS: The used VR system enabled real-time 3D-visualisation and manipulation of CT- and CAD-data. All objects could be independently moved in all three dimensions. The VR fitting test corresponded closely with the real implantation. The implantability of the hearing aid was properly predicted by all three examiners. CONCLUSION: Merging CT and CAD data in a virtual reality environment bears high potential for the pre-surgical determination of the fit and mountability of medical implants in complex anatomical regions.

Cochlear Implantation↗

[Analysis of artefacts by virtual endoscopy visualization of spiral CT data].

PURPOSE: Analysis of patterns and causes of artifacts found in endographic visualization of spiral CT data. MATERIALS AND METHODS: A straight perspex tube with a diameter of 20 mm was scanned in three different positions with ten scan protocols of varying table feed, increment, kernel, and signal to noise ratio (Tomoscan AVE, Philips). The resulting 30 CT datasets were visualized as a virtual endoscopy (VE) with ten different visualization protocols (Easy Vision 4.2, Philips) of varying threshold, resolution, and perspective angle. 300 VE datasets were analyzed by two radiologists and compared with the visualization of a software-generated tube in order to differentiate scanning and software artifacts. RESULTS: Five different classes of artifacts have been identified. Two of them result from the scanning process and two from the specific visualization method. Spiral patterns and the unevenness of the tube wall vary with the scanning parameter. Moiré-like patterns are caused by the VE software and depend on the visualization matrix. A high perspective angle distorts the size and form of the tube and makes it difficult for the observer to locate his position within the tube. The appearance of pseudoforamina depends on both the scanning and the visualization parameters. CONCLUSION: The knowledge of the patterns and potential causes of artifacts in endographic visualization of spiral CT scans are the basis for interpretation and optimization of this visualization method.

Artifacts↗

Utilisation of intramyocellular lipids (IMCLs) during exercise as assessed by proton magnetic resonance spectroscopy (1H-MRS).

Recently, a 1H-MRS method became available to quantify intramyocellular lipids (IMCL) non-invasively. Currently, little is known about the regulation of this lipid pool. During prolonged exercise of moderate intensity, non-plasma-derived fatty acids play an important role as an energy source; lipids located within the skeletal muscle are considered to be a major source for these fatty acids. To see whether IMCL are reduced by exercise, 12 male runners were studied before and after exercising at different workloads and duration. Six subjects participated in a non-competitive run (NCR), three runners in a competitive half marathon (HM, 21 km) and another three in a competitive marathon (M, 42 km). Intra- and extramyocellular lipids were quantified by 1H-MR spectroscopy in the tibialis anterior (TA) and soleus (SOL) muscles prior to and after the exercise bout. Moderate intensity (MI; 60-70% VO2max in NCR) with a mean exercise time (MET) ranging between 105-110 min decreased IMCL by 10 - 36% in both muscles. Prolonged MI exercise (MET 210-240 min; 68-70% VO2max in M) reduced IMCL by 42-57% in TA and 27 - 56% in SOL. In contrast, high intensity exercise (HI; MET 80-120 min; 83-85% VO2max in HM) did not alter IMCL in either muscle. Extramyocellular lipids (EMCL) did not show any significant change in any group. The data show that one bout of moderate-intensity (60-70% VO2max) aerobic exercise markedly reduces the IMCL in TA and SOL muscles in a time-dependent fashion as assessed by 1H-MRS. However, exercise of similar duration but higher workload (> 80% VO2max) does not reduce IMCL. These data suggest that both exercise duration and workload are important factors in determining the reduction of IMCL.

Adult↗

[Hybrid 3-D rendering of the thorax and surface-based virtual bronchoscopy in surgical and interventional therapy control].

PURPOSE: The aim of this study was to demonstrate the possibilities of a hybrid rendering method, the combination of a color-coded surface and volume rendering method, with the feasibility of performing surface-based virtual endoscopy with different representation models in the operative and interventional therapy control of the chest. MATERIAL AND METHOD: In 6 consecutive patients with partial lung resection (n = 2) and lung transplantation (n = 4) a thin-section spiral computed tomography of the chest was performed. The tracheobronchial system and the introduced metallic stents were visualized using a color-coded surface rendering method. The remaining thoracic structures were visualized using a volume rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle surface model, a shaded-surface model and a transparent shaded-surface model. RESULTS: The hybrid 3D visualization uses the advantages of both the color-coded surface and volume rendering methods and facilitates a clear representation of the tracheobronchial system and the complex topographical relationship of morphological and pathological changes without loss of diagnostic information. Performing virtual bronchoscopy with the transparent shaded-surface model facilitates a reasonable to optimal, simultaneous visualization and assessment of the surface structure of the tracheobronchial system and the surrounding mediastinal structures and lesions. CONCLUSIONS: Hybrid rendering relieve the morphological assessment of anatomical and pathological changes without the need for time-consuming detailed analysis and presentation of source images. Performing virtual bronchoscopy with a transparent shaded-surface model offers a promising alternative to flexible fiberoptic bronchoscopy.

Anastomosis, Surgical↗

[CT-guided therapy of osteoid osteoma by drill trepanation of the nidus. Clinical follow-up results].

PURPOSE: Evaluation of technical success and follow-up of patients with osteoid osteoma. MATERIAL AND METHODS: 9 patients (3 w, 6 m) with a mean age of 22.3 years suffering from an osteoid osteoma localized in the femur were treated with a combination therapy based on drill trepanation of the nidus and subsequent installation of 1-2 ml ethanol (96%). The treatment was done under CT-guidance in general anaesthesia. RESULTS: During the follow-up period of 20.6 months (10 to 39 months) one relapse occurred within 3 months. This was treated with the same percutaneous method. CONCLUSIONS: Percutaneous removal of intracortical osteoid osteomas under CT-guidance had success in this study, was technical easy, and a had low relapse rate. In addition the duration of hospitalisation is shorten. Meanwhile other studies have used additive ablation with radiofrequency. A second study has been started in our department using a thermoablative procedure. In a comparison between surgical and radiological methods, the rates of relapse are similar (9% vs. 23% surgically). The CT-guided removal of intracortical osteoid osteomas should be the procedure of first choice.

Adolescent↗

[2D-phase contrast flow evaluation and contrast-enhanced MR angiography for perioperative assessment of internal mammary artery grafts].

PURPOSE: To evaluate LV functional parameters, graft flow and patency in patients with IMA grafts using a combined MR protocol with phase-contrast technique and contrast enhanced MR angiography. MATERIAL AND METHODS: Using a 1.5 T MR system 27 patients with 27 left internal mammary artery (LIMA) and 41 venous grafts were examined before and 6 months after CABG surgery. A T(1)w-TSE sequence (slice thickness 5 mm) was applied for morphological imaging. LV function (EF, CO) was evaluated on cine images (segmented FLASH 2D, TR(eff) 11 ms, TE 4.8 ms, flip angle 25 degrees ). A phase-contrast FLASH 2D (TR 24 ms, TE 5 ms, flip angle 20 degrees ) sequence was applied for aortic and IMA flow measurements. Postoperatively, a contrast enhanced FLASH 3D MR angiography (TR 3.8 ms, TE 1.4 ms, flip angle 30 degrees ) with 25 ml Gd-DTPA was performed to assess bypass patency. RESULTS: In patients with reduced LV function (ejection fraction < 50 %) an improvement of the ejection fraction from 38.4 +/- 10.3 % to 49.8 +/- 15.3 % (p < 0.05) was found postoperatively. LIMA grafts were occluded in 1/27 patients, while 6/41 venous grafts were occluded. Distal LIMA anastomoses were demonstrated in 33 % by MRA. Flow of LIMA decreased from 21.2 +/- 11 ml/min/m(2) preoperatively to 14.4 +/- 9.6 ml/min/m(2) postoperatively (p < 0.01). CONCLUSION: MR imaging allows accurate combined assessment of LV function, bypass patency and flow. The protocol of this study may be applicable for perioperative follow-up studies in patients after CABG surgery.

Aged↗

[MR-venography using manual flow augmentation in an open low field MR system].

OBJECTIVE: To evaluate the feasibility of signal enhancement in the deep veins by means of manual compression of the calf (flow augmentation) as a new approach to MR venography in open configuration, low-field systems. METHODS: 10 healthy volunteers underwent MR venography of the calf unconstrained and during short localized manual compression. Gradient recalled echo sequences (FLASH, FISP) with repeated single slice acquisition and first-order gradient motion refocussing were tested in four protocols with and without arterial presaturation slabs (scan time 2.2 - 5.0 s per slice). The effect on flow enhancement was rated by means of a signal score. Interventional accessories, particularly an in-room LCD screen, were required for interactive application of compression manoeuvres. RESULTS: Sequences with arterial presaturation slabs were superior to those without regardless of the longer acquisition times. Careful targeting of compression to the mid-time of data acquisition was crucial to obtain marked flow acceleration. Enhancement was best in the case of proximally applied calf compression. Signal improvement was consistently achieved in the proximal parts of the posterior tibial and peroneal veins, but was only seen in 4/10 volunteers in the distal part of the anterior tibial vein. CONCLUSION: Flow augmentation by means of manual calf compression is a simple and effective complementary approach to MR venography in open configuration, low field MR systems.

Adult↗

[Quantitative assessment of therapy related effects after breast conserving therapy with dynamic MRI of the breast].

PURPOSE: To quantify therapy related effects after breast conservation therapy (BCT) with dynamic MRI of the breast. METHODS: Twenty patients (median age 51 years) with breast conserving tumor excision were included. Contrast enhanced dynamic MRI was performed before and 3, 6 and 12 months after adjuvant radiation therapy (RT) with a total dose of 50.0 to 50.4 Gy. The following sequences were applied: axial fat-suppressed T(2)-weighted; coronal contrast enhanced 3D spoiled gradient-echo (first measurement prior to the administration of 0.16 mmol/kg Gd-DTPA, six repetitive measurements); sagittal T(1)-weighted Flash3D. Enhancement data were obtained using a computer software with automated segmentation of regions of interest (ROIs). After defining ROIs for skin, parenchyma and pectoral muscle of each breast the early enhancement after the first post contrast measurement (E(1)) and the slope of enhancement between the second and last postcontrast measurement (SE(2-L)) were calculated. The edema was quantified by assessing the signal intensities (SI) in the T(2)-weighted images. The thickness of the skin was measured in the sagittal T(1)-weighted images. RESULTS: Three months after RT statistically significant increases between 51 and 179 % of the SI and E(1) quotients were detected for all tissues compared to the examinations prior to RT. Six months after RT the skin still presented a by 102 % significantly higher E(1) quotient, and a by 140 % significantly increased SI quotient. No significant differences for SI and E(1) quotients could be observed 12 months after RT compared to the examinations prior to RT. A significant increase of the SE(2-L) difference for the skin from 0.0225 to 0.0691 and 0.0665 was found 3 and 6 months after RT, respectively. No significant differences between the initial MR examination and the follow-up examinations 3, 6 and 12 months could be detected for the SE(2-L) differences of the parenchyma. CONCLUSION: Early therapy related effects after BCT can be exactly quantified with dynamic MRI using an automated ROI-segmentation and whole breast analysis software. Both edema formation and early enhancement show peaks 3 months after RT, and after 12 months there is no statistically significant difference compared with baseline.

Adult↗

[Multidetector CT Angiography - is it a valuable screening tool to detect significant renal artery stenosis?].

PURPOSE: To evaluate the diagnostic value of multidetector CT angiography (MDCTA) of the renal arteries. METHODS: 27 patients underwent MDCTA of the renal arteries. Scan parameters were: collimation 4 x 1 mm, pitch 1.5, effective slice thickness 1.25 mm, reconstruction increment 0.8 mm, circulation time measurement, power injection of 80 ml iomeprol 400, flow 4 ml/sec. Independent reading on laser film was done by two radiologists using edited maximum intensity projections, multiplanar reconstructions and source images. Standard of reference was a 3D-FLASH MR angiography (1.5 T, 3.9/1.2, 10 degrees 0.2 mmol GdDTPA/kg bw) in 10 and intraarterial angiography in 17 patients. RESULTS: Analysing 63 arteries, sensitivity, specificity, positive predictive value and negative predictive value in terms of detection of moderate and high grade renal artery stenosis (n = 10) were 90, 98, 90 and 98 % for reader A, and 90 % each for reader B, respectively (kappa = 0.91 interobserver agreement). 1/11 accessory renal arteries was missed by both angiography and MDCTA. Image quality was graded as excellent or good in 26/27 of cases by both readers. CONCLUSION: MDCTA proved to be a highly accurate tool in the detection of therapeutically relevant renal artery stenosis.

Aged↗

Local intra-arterial drug delivery for prevention of restenosis: comparison of the efficiency of delivery of different radiopharmaceuticals through a porous catheter.

RATIONALE AND OBJECTIVES: Several radiopharmaceuticals were administered through a porous balloon catheter to compare the absolute amount deposited and the retention in the vessel wall. The reported efficiency of local drug delivery ranges from 0.001% to 0.1%, with poor retention after 24 hours. METHODS: An endothelin derivative (n = 6), pertechnetate (n = 6), hexamethylpropylene amineoxime (HMPAO) (n = 5), ethyl cysteinate dimer (ECD) (n = 5), and tin colloid (n = 5) were labeled with 185 MBq/mL 99m-technetium. After balloon denudation of the infrarenal aorta in 27 New Zealand White rabbits, 100 microL of each agent was administered through a porous balloon at a pressure of 4 bar. Dynamic and static whole-body scintigrams were obtained for 24 hours. The infrarenal aorta was excised and the activity calculated in a gamma counter. RESULTS: Apart from their retention in the region of local administration, the radiopharmaceuticals showed different distribution patterns. The highest regional tracer retention was observed with HMPAO. After administration of HMPAO, a significant difference between regional (vessel wall plus surrounding tissue: 14.5% of injected dose [ID]/24 hours) and local (vessel wall: 1.8% ID/24 hours) delivery was found. In contrast, ECD was eliminated quickly (local retention after 24 hours = 0% ID). The retention efficiencies were HMPAO > endothelin derivative > tin colloid > pertechnetate > ECD. CONCLUSIONS: The different physicochemical and pharmacokinetic properties of radiopharmaceuticals resulted in different delivery efficiencies after local application.

Animals↗

Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.

PURPOSE: To investigate how the technique of retrospective gating can be used to optimize reconstruction of multi-detector row computed tomographic (CT) images for each of the three major coronary arteries during the cardiac cycle. MATERIALS AND METHODS: Multi-detector row coronary CT angiograms obtained in 50 patients were reconstructed at 20%-80% of the cardiac cycle in increments of 10%. Two blinded independent reviewers assessed the image quality, in terms of artifacts and visibility, obtained with three-dimensional postprocessing for segments 1-3 (right coronary artery), segments 5-8 (left main and left anterior descending coronary arteries), and segments 11 and 12 (left circumflex artery). The following grades were assigned: 1, very poor; 2, poor; 3, fair; 4, good; and 5, excellent. RESULTS: The left anterior descending artery was best visualized in middiastole at 60%-70% of the cardiac cycle, and the left circumflex artery was best visualized at 50%. The optimal reconstruction window for the right coronary artery was significantly different at 40% (P < .05). Although there was good agreement (kappa = 0.75) between the two reviewers, there was a high degree of variation in the patient population. CONCLUSION: The image reconstruction window for CT angiography of the coronary arteries should be adapted to each coronary artery. The use of one fixed time point in the cardiac cycle for image reconstruction does not provide optimal image quality.

Aged↗

Peripheral artery occlusion: treatment with abciximab plus urokinase versus with urokinase alone--a randomized pilot trial (the PROMPT Study). Platelet Receptor Antibodies in Order to Manage Peripheral Artery Thrombosis.

PURPOSE: To evaluate the combination of a platelet glycoprotein IIb/IIIa complex receptor inhibitor and urokinase for treatment of recent (<or=6 weeks) arterial occlusion of the legs. MATERIALS AND METHODS: Seventy patients with lower extremity arterial occlusion of less than 6 weeks duration were randomly separated into two treatment groups: urokinase plus abciximab or urokinase plus placebo. Primary end points were the rate of major complications at 30 days after randomization and the rates of amputation-free survival and survival without open surgery or major amputation at follow-up of 90 days. Two readers unaware of the patients' treatment group assignments analyzed digital subtraction angiograms as they related to the study end points, with a final consensus reading. RESULTS: Thrombolysis relative to clot length was faster in the urokinase-plus-abciximab group (odds ratio, 0.52; 95% CI: 0.35, 0.76; P < .001). There were no procedure-related deaths or intracranial hemorrhages, but the rate of nonfatal major bleeding was higher with urokinase plus abciximab (four of 50 patients) than with urokinase alone (none of 20 patients; P = .32). At 90 days, amputation-free survival was 96% (48 of 50 patients) in the urokinase-plus-abciximab group compared with 80% (16 of 20 patients) in the urokinase alone group. The hazard ratio for the two Kaplan-Meier curves was 0.42 (95% CI: 0.16, 0.96; P = .04). CONCLUSION: In patients with lower extremity arterial occlusion who were undergoing urokinase thrombolysis, adjunctive abciximab treatment resulted in faster thrombus dissolution and improved amputation-free survival, despite an increase in major bleeding.

Abciximab↗