Search PubMed⌕ Search

Biomedical subjects

C D Claussen

Publications and source records attributed to C D Claussen.

At least 37 records · Page 2Linked to original sources

Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology.

OBJECTIVE: To report an initial experience with multislice spiral computed tomography (MSCT) coronary imaging, as well as differences in diagnostic accuracy between 4 slice and 16 slice MSCT technology. METHODS AND RESULTS: 210 patients underwent MSCT coronary angiography (4 slices, n = 120; 16 slices, n = 90; suspicion of coronary artery disease, n = 158; suspicion of restenosis, n = 52). Recommendations for further diagnostic tests were based on the MSCT results. Patients were interviewed by telephone after a mean (SD) of 449 (169) days to evaluate their further clinical course. MSCT detected significant lesions in 90 of 210 (43%) patients and invasive coronary angiography (ICA) was recommended. MSCT excluded significant lesions in 120 of 210 (57%) patients. ICA was actually performed in 44 of 210 (21%) patients (corresponding results, 27 of 44 (61%); false positive, 11 of 44 (25%); false negative, 6 of 44 (14%)). No significant differences were found between 4 and 16 slice imaging. No major cardiac event occurred during follow up. CONCLUSIONS: MSCT was found to be useful to evaluate the need for invasive diagnostic procedures. However, the false negative results underline that further improvements of image quality are required before MSCT can replace ICA in carefully selected patients.

Coronary Artery Disease↗

Image fusion of CT and MRI for the visualization of the auditory and vestibular system.

The aim of this study was to perform a realistic visualization of the auditory and vestibular system using volume data sets from high-resolution computed tomography (HR-CT) and high-resolution magnetic resonance imaging (HR-MRI). - In 10 patients with conductive and/or sensorineural hearing loss, vertigo and tinnitus, HR-CT and HR-MRI of the petrous bone were performed consecutively. CT was performed with a 16-slice computed tomography scanner using a high spatial resolution. MRI was performed with a 3.0 Tesla scanner using a three-dimensional-constructive interference in steady state (3D-CISS) gradient-echo, and T2-weighted, unenhanced and gadolinium (GD)-enhanced T1-weighted turbo spin-echo sequences. The middle ear structures were interactively segmented and visualized with a color-coded shaded-surface rendering method using the HR-CT volume data sets. The inner ear structures were interactively segmented and visualized with a color-coded shaded-surface rendering method using the high-resolution 3D-CISS MRI volume data sets. Finally, both shaded-surface rendered models were superimposed semi-automatically using a commercial available software program to visualize the auditory and vestibular system. - The representation of the middle and inner ear structures with image fusion of HR-CT and HR-MRI takes advantage of both the high bony contrast of HR-CT and the high soft tissue contrast discrimination and sensitivity to fluids of HR-MRI, as well as the high spatial resolution of both modalities. In comparison to the fused axial CT/MRI, the images of 3D CT/MRI fusion facilitates a clear representation and better spatial orientation. - The middle and inner ear consists of bony structures, soft tissue structures and fluid-filled spaces. For this reason, the image fusion of volume data sets from HR-CT and HR-MRI allowed an optimized and realistic visualization of the auditory and vestibular system.

Adolescent↗

Initial CT manifestations of invasive pulmonary aspergillosis in 45 non-HIV immunocompromised patients: association with patient outcome?

PURPOSE: To assess early high-resolution computer tomographic (CT) signs of invasive pulmonary aspergillosis (IPA) in non-HIV immunosuppressed patients and their potential association with patient's outcome, including frequency and severity of pulmonary hemorrhage, taking also in consideration the impact of other known risk factors contributory to IPA. MATERIAL AND METHODS: A retrospective review of serial CT scans was performed in 45 immunocompromised patients with a total of 46 episodes of invasive pulmonary aspergillosis. All patients underwent CT beginning with the day they showed clinical or laboratory signs of infection. Serial follow-up CT included more than two, up to 12 CT examinations. Patient's outcome was judged by clinical and radiological follow-up and classified as survival, death by IPA, or death unrelated to IPA. The influence of patient's age, underlying disease, hematopoietic stem cell transplantation, neutropenia, graft versus host disease, and antifungal therapy onset was also statistically considered. RESULTS: Three main CT findings were identified: small nodules (<1cm) 43% (20/46), large nodules 21% (10/46) and consolidations, either in patchy+/-segmental 26% (12/46), or peribronchial distribution+/-tree in bud 9% (4/46). In 11 patients (24%) we found a combination of two or more of these signs: 9 (19%) patients presented concurrent small nodules accompanied by reticulation, tree in bud or peribronchial infiltrates, while 2 (4%) patients showed large pulmonary nodules accompanied by large consolidations. An accompanying "halo" sign was observed in 38 patients (82%). Crescent sign followed by cavitation was encountered in 29 patients (63%). Two patients succumbed to massive pulmonary bleeding caused by IPA. Twenty-one patients (15/46) deceased in this series, 12 of them succumbed to IPA, 1 died from cerebral invasive aspergillosis, while in 9 patients the cause of death was not primarily IPA. Manifest pulmonary hemorrhage occurred in 19% (9/46) of IPA episodes. CONCLUSION: Initial CT findings of invasive pulmonary aspergillosis consist mainly of small nodules or patchy consolidations, showing in 82% of cases an early halo sign. Serious pulmonary hemorrhage was an infrequent clinical complication in our series, with an attributable mortality of 4.3%. IPA-related lethality was 26%, in our cohort. None of the early HRCT signs seemed to predict outcome.

Adolescent↗

Significance of the "halo" sign for progression and regression of nodular pulmonary amyloidosis: radiographic-pathological correlation (2005:6b).

We describe a case of a systemic amyloidosis of kappa-AL type, presenting at CT as focal lung parenchymal nodules or areas of consolidation with or without a halo,showing different sizes and morphologic kinetics at follow-up. Lesions accompanied by a halo revealed faster progression and earlier response to chemotherapy with almost complete resolution after high dose therapy with a cytostatic alkylating agent(Melphalan) and autologous peripheral stem cell transplantation than their counterparts without a halo. Amyloid deposition was histologically confirmed, and severe inflammatory activity was found in and at the margins of the amyloidomas, the latter correlating in CT with the halo sign. In our case, this sign had a high prediction for growth kinetics and response to therapy of pulmonary amyloid.

Amyloid↗

[Left ventricular functional parameters: comparison of 16-slice spiral CT with MRI].

PURPOSE: The quantitative measurement of left ventricular functional parameters using multislice computed tomography (MSCT) with retrospective ECG-gating and comparison of the results with magnetic resonance imaging (MRI). MATERIALS AND METHODS: Thirty-one patients with suspected or known coronary artery disease underwent MSCT angiography with retrospective ECG-gating (Sensation 16, Siemens). Based on the CT data set, short axis reformations of the left ventricle were performed for functional analysis. On a commercially available workstation, end-diastolic- (EDV), end-systolic- (ESV), stroke volume (SV), ejection fraction (EF) and myocardial mass (MM) were calculated from MSCT (temporal resolution 105 - 210 ms) data according to the modified Simpson's rule and compared to MRI (1.5 T scanner, temporal resolution 48 ms) using a 2D TrueFISP cine sequence with respiration hold. RESULTS: In all cases, the quality was adequate for both MSCT and MRI. MSCT and MRI had an excellent correlation for EDV (r = 0.86), ESV (r = 0.91), EF (r = 0.87) and MM (r = 0.88), and a good correlation for SV (r = 0.70). The mean difference was 13.2 +/- 21.9 ml for EDV, 8.7 +/- 15.9 ml for ESV, 4.6 +/- 12.3 ml for SV, 1.4 +/- 5.2 % for EF, and 11.9 +/- 13.8 g for MM. However, EDV (p = 0.002), ESV (p = 0.005), SV (p = 0.048), and MM (p < 0.0001) were significantly overestimated with MSCT compared to MRI. For EF, no significant difference between MSCT and MRI was found (p = 0.15). CONCLUSION: For left ventricular functional parameters, MSCT of the heart with retrospective ECG-gating showed a high correlation with MRI, which has an important implication when using MSCT for non-invasive cardiac imaging. Despite the high correlation, overestimation of EDV, EVS, SV, and MM with MSCT has to be taken into account when applying this technology in clinical practice. EF was not significantly different between both modalities.

Aged↗

[Detection of pulmonary nodules with breath-hold magnetic resonance imaging in comparison with computed tomography].

PURPOSE: Evaluation of sensitivity and false positive findings of two fast MRI sequences for the detection of pulmonary nodules in comparison with spiral CT by two independent observers. MATERIALS AND METHODS: All 30 enrolled patients had a spiral CT or MSCT as base line study. MRI was performed with a 1.5 T MR scanner (Sonata, Siemens) using a transverse 3D gradient echo sequence (3D-GRE: TR/TE/flip = 2.9 ms/1.1 ms/5 degrees ) and a half-Fourier single-shot fast spin-echo sequence (HASTE: TR/TE/flip = 800/25/150 degrees ) acquired in three planes. A separate analysis for both sequences was carried out prospectively by two independent readers (A and B) with different experience regarding pulmonary MRI. Additionally, a retrospective reading with knowledge of the CT scans was done. Results were calculated for all lesions and for lesions larger than 4 mm. RESULTS: The sensitivities were 73 %, 70 % and 84 % for the 3D-GRE sequence (reader A, reader B, retrospective reading) and 65 %, 68 % and 81 % for the HASTE sequence. For lesions larger than 4 mm, the sensitivities were 93 %, 89 %, 96 % for the 3D-GRE sequence and 85 %, 85 %, 96 % for the HASTE sequence. The rate of false positive findings depended on the reader's experience, but was generally lower for the 3D-GRE sequence with 2 and 16 (reader A and B) false positive nodules compared to 4 and 40 false positive findings for the HASTE sequence. The 3D-GRE sequence was more accurate for both readers (reader A: p = 0.08, reader B: p = 0.00003). CONCLUSION: The sensitivity of MRI for the detection of lung nodules was only acceptable for lesions larger than 4 mm. The 3D-GRE sequence is superior to the HASTE sequence due to the reduced amount of false positive findings with comparable sensitivity.

Adult↗

[Magnetic resonance imaging -- guided corticosteroid-infiltration of the sacroiliac joints: pain therapy of sacroiliitis in patients with ankylosing spondylitis].

PURPOSE: To evaluate the efficacy and specific properties of MR imaging-guided corticosteroid infiltration of the sacroiliac (SI) joints in the treatment of therapy-refractory sacroiliitis in patients with ankylosing spondylitis. MATERIALS AND METHODS: In this study, 26 patients were prospectively included. Inclusion criteria were AS with therapy refractory acute sacroiliitis and inflammatory back pain > or = 6 months. The intervention was performed using an open low-field MR-scanner. Inflammatory back pain was assessed on a visual analog scale (VAS). Success of the therapy was defined as an absolute reduction of the VAS score </= 5, a relative reduction of the VAS score > or = 35 % and persisting improvement > or = 2 months. The grade of sacroiliitis was documented using high-field MR imaging. Variables were compared using McNemar test and Wilcoxon test. The mean remission time was calculated using a Kaplan-Meier analysis. A p-value < 0.05 was considered statistically significant. RESULTS: The intervention was technically successfully performed in all patients. Following MR imaging-guided corticosteroid infiltration of the SI joints, the VAS score improved from 8 (5 - 10) points to 4.5 (0 - 8) points (- 44 %) in all patients (n = 26), which was statistically significant (p < 0.001). Of 26 patients, 22 (85 %) fulfilled the predefined criteria for successful therapy. This group had a statistically significant (p < 0.01) improvement of the VAS score from 8 (6 - 10) to 3 (0 - 5) (- 63 %). Improvement was seen after 7 (1 - 30) days. There was a marked reduction of the subchondral bone marrow edema (- 38 %). The mean remission time was 12 (4 - 18) months. CONCLUSION: MR imaging-guided corticosteroid infiltration of the SI joints proved to be an effective therapy of inflammatory back pain in patients with therapy refractory AS. With the ability of multiplanar imaging, precise localization of the bone marrow edema and the lack of ionizing radiation, interventional MR imaging currently represents the superior method for the treatment of the predominantly young patient group presenting with ankylosing spondylitis. Owing to short intervention times, open MR-scanners are ideally suited for MR imaging-guided infiltration of the SI joints.

Adrenal Cortex Hormones↗

[Radiofrequency ablation of renal cell carcinomas using MR imaging: initial results].

PURPOSE: First results of a study about the efficacy of magnetic resonance-(MR-)guided radiofrequency ablation of renal cell carcinomas (RCC) are presented. MATERIAL AND METHODS: Eight patients (63 to 82 years old) with RCC up to 3.9 cm in diameter were treated by percutaneous RF ablation under MR-guidance in an open MR scanner at 0.2T field strength. For positioning of the RF-electrode, fluoroscopic rapid gradient echo sequences (acquisition time about 2 sec) were used. The ablation was monitored by intermittent imaging with T1- and T2-weighted spin echo sequences. RESULTS: In each patient, the applicator was successfully positioned within the tumor using MR-guidance. Seven of eight patients were completely treated within one single session; one patient had to be retreated for tumor relapse at 13 months. The mean number of electrode repositionings under MR guidance for complete ablation was 2.0; ablation time ranged between 12 and 28 minutes. Maximum diameter (volume) of induced coagulation necrosis within one session was 3.9 cm (30.2 cm (3)) by using cluster electrodes. With single electrodes, maximum short axis diameter of coagulation without repositioning was 2.4 cm (11.6 cm (3)). All patients are now disease-free after a mean follow up of 13 months (5 to 21 months). No major complications occurred during or after the ablation procedure. CONCLUSION: MR-guided RF ablation in an open interventional 0.2T MR-unit is a safe and effective modality for the treatment of RCC. Fast MR-imaging is a convenient method for exact positioning of MR-compatible RF-electrodes. Near on-line MR-monitoring of ablation procedure with T2-weighted imaging allows for immediate assessment of the coagulation extent.

Aged↗

[MR angiography and determination of the flow reserve after minimal invasive direct coronary artery bypass (MIDCAB) surgery of the left internal mammary artery in comparison to multirow CT].

PURPOSE: To evaluate graft patency, flow and flow reserve in patients with minimal invasive direct coronary artery bypass (MIDCAB) of internal mammary artery (IMA) grafts using a combined MR protocol with phase-contrast technique and MR angiography. MATERIAL AND METHODS: At a 1.5T Magnetom Sonata (SIEMENS), 19 symptomatic (angina CCS I-III, intermittent thoracic discomfort, scar disorders) patients (59.9 +/- 7.9 years old) with 19 left internal mammary artery (LIMA) grafts implanted in minimal invasive technique were examined 6.9 +/- 1.5 years post surgery. Contrast enhanced MR angiography (TR 2.5 ms, TE 1 ms, flip angle 20 (o), spatial resolution 1.4 x 0.9 x 1.0 mm(3), breath hold technique, no ECG-triggering, 25 ml Gd-DTPA) was performed to assess bypass patency. Phase-contrast flow measurements with retrospective gating (TR 41 msec, TE 3.2 msec, flip angle 30 degrees , spatial resolution 1.1 x 1.1 x 5 mm(3), temporal resolution 42 msec, venc 90 cm/sec) were applied in the IMA grafts at rest and after stress induction with dipyridamole (0.56 mg/kg/BW). For comparison, graft patency was evaluated by multidetector-row computed tomography (16-row CT). In 9 patients a selective catheter angiography was performed. RESULTS: MIDCAB grafts were occluded in 4/19 patients. In 4 patients the anastomosis to LAD was highly stenotic (> 70 %) at MDCT (2 experienced investigators in consensus reading). In MRA 9 grafts could be delineated completely including the distal anastomosis to LAD (47 %). In 9 patients the distal part could not be evaluated. In patients with patent grafts (MDCT), a significant improvement of graft flow (at rest 75.4 +/- 33.3 ml/min; after stress 202.7 +/- 49.6; P < 0.002) and flow reserve (patent grafts 3.0 +/- 1.1; stenotic grafts 1.5 +/- 0.2, P < 0.02; occluded grafts 0.9 +/- 0.2, P < 0.01) after stress induction was detected. Diastolic-to-systolic peak velocity ratios (D/S-PVR) at baseline were not significant between patent and stenotic grafts. Mean flow at baseline and after stress induction and flow reserve show a high sensitivity (91/92 /83 %) and specificity (86 /100/83 %) for detection of graft stenosis. MR angiography combined with flow reserve measurements could distinguish between occluded/stenotic and patent grafts in all MIDCAB grafts. CONCLUSION: MR imaging allows combined assessment of bypass patency and flow with flow reserve in patients after MIDCAB. The protocol of this study is applicable for the evaluation of graft patency in patients after revascularization.

Blood Flow Velocity↗

High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media.

PURPOSE: The feasibility of high-resolution arterial spin labeling (ASL) perfusion imaging of the kidneys was tested and proven at 3 Tesla using a flow-sensitive alternating inversion recovery (FAIR) true fast imaging in steady precession (TrueFISP) technique. MATERIALS AND METHODS: Kidney perfusion maps of six healthy volunteers and two patients were acquired using a clinical 3-Tesla whole-body scanner. An ASL sequence with FAIR spin preparation and a TrueFISP signal detection strategy was adapted for high-resolution perfusion imaging of the kidneys at 3 Tesla. To avoid banding artifacts in TrueFISP images, which are generally prominent at 3 Tesla, a frequency scout was implemented. Perfusion maps with an in-plane resolution of 1.5 mm were recorded in transverse and coronal orientation. For fast mapping of whole-kidney perfusion, an in-plane resolution of 2 mm was applied. RESULTS: In all volunteers and patients, high-resolution perfusion images with excellent image quality were able to be obtained in a measuring time of approximately 10 minutes. The whole kidney was able to be mapped with good image quality in less than 10 minutes. For all slices, a suitable frequency offset made it possible to reproduce the kidneys without TrueFISP artifacts. Perfusion values of the renal cortex ranged from 250 ml/100 g/min up to 400 ml/100 g/min (mean cortical perfusion right kidney 316 +/- 43, left 336 +/- 40). CONCLUSION: High-resolution ASL perfusion images of the whole kidney were able to be obtained with good image quality by means of a 3 Tesla MR setting within a clinically applicable measuring time, thus providing an alternative to conventional perfusion imaging involving potentially nephrotoxic contrast media.

Adult↗

Microcalcifications of the breast: how does radiologic classification correlate with histology?

PURPOSE: To assess the correlation between the pre-biopsy classification of microcalcifications and the underlying histology. MATERIAL AND METHODS: Using the morphology and distribution patterns according to the Breast Imaging-Reporting and Data System (BI-RADS) lexicon, the microcalcifications of 199 lesions in 163 consecutive patients scheduled to undergo 11 G vacuum core biopsy were classified within the BI-RADS categories. The correlation between BI-RADS assessment categories 3, 4, and 5 and the final histological results was statistically evaluated with the chi2 test. The diagnostic indices were calculated. RESULTS: The prospectively classified BI-RADS 3/4/5 findings revealed a malignant histology in 5.9%/17.6%/90.9% of all lesions, respectively. The relationship between BIRADS categories 3, 4, and 5 and histology was statistically highly significant (P<0.0001). The sensitivity, specificity, positive and negative predictive values were 95.7%/21.2%,/37.8%/94.3%, respectively. CONCLUSION: The BI-RADS lexicon describes microcalcifications of the breast and provides diagnostic categories that lead to standardized biopsy recommendations. Nevertheless, how to link description to classification of microcalcifications is still a difficult diagnostic task. The evaluation of microcalcifications as proposed in this article may help to set standards in the clinical routine and in the comparability of scientific data.

Adult↗

Magnetic resonance elastography of the breast: correlation of signal intensity data with viscoelastic properties.

OBJECTIVES: We sought to investigate the potential value of magnetic resonance (MR) elastography to improve the differentiation between benign and malignant tumors. MATERIAL AND METHODS: Measurements of 5 patients with 6 malignant lesions, 11 patients with benign lesions, and 4 patients with no lesions at all were performed at 1.5 Tesla. After breast MR imaging, MR elastography was performed as a targeted measurement. Low-frequency mechanical waves (65 Hz) were transmitted into the breast tissue using an oscillator and were displayed by means of a MR sequence within the phase of the MR image. After reconstruction, the viscoelastic information was correlated with the signal intensity and morphology data. RESULTS: All examinations were technically successful realized in approximately 25 minutes. Malignant tumors documented higher values of elasticity than benign corresponding with signal intensity and morphologic data. CONCLUSION: A good separation exists between benign and malignant lesions in elasticity, corresponding with specific signal intensity and morphologic data. Further clinical studies with a larger number of patients are needed for extended validation.

Adolescent↗

Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution.

OBJECTIVE: To evaluate image quality and clinical accuracy in detecting coronary artery lesions with a new multidetector spiral computed tomography (MDCT) generation with 16 detector slices and a temporal resolution of 188 ms. METHODS: 124 consecutive patients scheduled for invasive coronary angiography (ICA) were additionally studied by MDCT (Sensation 16 Speed 4D). MDCTs were analysed with regard to image quality and presence of coronary artery lesions. The results were compared with ICA. RESULTS: 120 of 124 scans were successful. The image quality of all remaining 120 scans was sufficient (mean (SD) heart rate 64.2 (9.8) beats/min, range 43-95). The mean calcium mass was 167 (223) mg (range 0-1038). Thirteen coronary segments were evaluated for each patient (1560 segments in total). Image quality was graded as follows: excellent, 422 (27.1%) segments; good, 540 (34.6%) segments; moderate, 277 (17.7%) segments; heavily calcified, 215 (13.8%) segments; and blurred, 106 (6.8%) segments. ICA detected 359 lesions with a diameter stenosis > 50% and MDCT detected 304 of 359 (85%). Sensitivity, specificity, and positive and negative predictive values were 85%, 98%, 91%, and 96%, respectively. The correct clinical diagnosis (presence or absence of at least one stenosis > 50%) was obtained for 110 of 120 (92%) patients. CONCLUSIONS: MDCT image quality can be further improved with 16 slices and faster gantry rotation time. These results in an unselected population underline the potential of MDCT to become a non-invasive diagnostic alternative, especially for the exclusion of coronary artery disease, in the near future.

Aged↗

Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol.

The objective of this study was to evaluate graft flow (f) and patency (p) in patients with internal mammary artery (f,p) and venous (p only) grafts using a combined MR protocol with phase-contrast technique and MR angiography. 42 patients with 42 left internal mammary artery (LIMA) and 63 venous grafts were examined pre and 6 months post coronary artery bypass graft (CABG) surgery. Phase-contrast flow measurements were applied to the IMA. Post-operatively, a contrast enhanced MR angiogram was performed to assess bypass patency. LIMA/venous grafts were occluded in 3/42 and 13/63, respectively. Flow in LIMA decreased from 19.4+/-10.4 ml min(-1) m(-2) pre-operatively to 13.4+/-9.7 ml min(-1) m(-2) post-operatively (p<0.002). In contrast, flow in the native right IMA increased from 17.6+/-8.7 ml min(-1) m(-2) pre-operatively to 24.8+/-9.0 ml min(-1) m(-2) post-operatively (p<0.001). MRI allows a combined assessment of bypass patency and flow. This study protocol may be applicable to perioperative follow-up studies in patients after CABG surgery.

Aged↗

Comparison of full-field digital mammography and film-screen mammography: image quality and lesion detection.

The objective of this study is to compare image quality and lesion detection for full field digital mammography (FFDM) and film-screen mammography (FSM). In 200 women we performed digital mammography of one breast and film-screen mammography of the other breast. Imaging parameters were set automatically. Image quality, visualization of calcifications and masses were rated by three readers independently. Mean glandular dose was calculated for both systems. We found no significant difference in mean glandular dose. Image quality was rated by reader A/B/C as excellent for FFDM in 153/155/167 cases and for FSM in 139/116/114 cases (p<0.03/0.001/0.001). Microcalcifications were detected by FFDM in 103/89/98 and by FSM in 76/76/76 cases (p<0.01/0.06/0.01). Detection of masses did not differ significantly. FFDM provided significantly better visibility of skin and nipple-areola region (p<0.01). FFDM demonstrated improved image quality compared with film-screen mammography. Microcalcification detection was also significantly better with the digital mammography system for two of the three readers.

Adult↗

Invasive pulmonary aspergillosis: frequency and meaning of the "hypodense sign" on unenhanced CT.

The purpose of this study was to establish the diagnostic value of central hypointensity ("hypodense sign") in lung consolidations or nodules, in severely immunocompromised or neutropenic patients, suspected of having invasive pulmonary aspergillosis (IPA), and to assess its recognition on unenhanced CT scans. Serial CT scans of the lung were retrospectively reviewed in 43 consecutive immunosuppressed patients with IPA, and assessed for the presence of the hypodense sign using standard mediastinal and lung windowing settings, as well as a special, narrower window setting (width 110-140 HU; level 15-40 HU). The temporal relationship between the occurrence of the first CT-finding suspicious of IPA and the appearance of the hypodense sign, as well as between this and the occurrence of the crescent sign, cavitation or reduction in lesion size, was evaluated. Additionally, CT-scans from 89 immunocompromised patients with viral (n=45) or bacterial (n=44) pneumonia, investigated in the same time period at our institution were reviewed, with respect to the presence of the "hypodense" sign. Unenhanced CT scans revealed the hypodense sign in 11 neutropenic patients and 2 severely immunocompromised patients, out of a total of 43 patients with IPA evaluated in this study (30.2%). The mean time between the appearance of the first CT-findings of IPA (large nodule or consolidation +/- positive halo sign) and the hypodense sign was 7.8 days, while the time interval between the hypodense sign and the occurrence of crescent sign, cavitation, or decrease of the lesion's size was 8.3 days. The hypodense sign did not occur in any of the patients with viral or bacterial pneumonia, in the control series. We consider the hypodense sign to be a supplementary tool in the diagnosis of IPA. Its sensitivity was low in our series, but the high specificity makes it valuable in predicting IPA, anticipating the occurrence of cavitation or crescent sign, which are considered specific, but late findings of IPA. The hypodense sign is recognizable also on unenhanced CT, when a narrower lung window setting is used.

Adolescent↗