Search PubMed⌕ Search

Biomedical subjects

C Cusatis

Publications and source records attributed to C Cusatis.

4 recordsLinked to original sources

An inelastic X-ray scattering spectrometer at LNLS.

A high-resolution spectrometer aimed at performing experiments of inelastic X-ray scattering by electronic excitations is described. The spectrometer has been installed at the D12A-XRD1 beamline of the National Synchrotron Light Laboratory (LNLS), in Campinas, Brazil. Synchrotron radiation is monochromated to about 6 keV and focused horizontally onto the sample by a sagittally focusing Si(111) double-crystal monochromator in non-dispersive setting. The spectrometer operates in Rowland circle geometry and is based on a focusing Si(333) analyser in near-backdiffraction geometry for energy analysis of inelastically scattered photons. The analyser works at a fixed Bragg angle, so energy transfers are obtained by varying the incident photon energy. A relative energy resolution of the whole spectrometer of approximately 1.5 x 10(-4) at 5.93 keV has been achieved. As an example of application, inelastic X-ray scattering by plasmon excitation in polycrystalline Be was measured. Test results demonstrate that inelastic X-ray scattering experiments with eV energy resolution and an acceptable counting rate are feasible at the LNLS when focused on plasmon and particle-hole excitations.

Journal Article↗

First experiments on diffraction-enhanced imaging at LNLS.

Diffraction-enhanced images have been obtained using two silicon crystals in a non-dispersive set-up at the XRD2 beamline at the Brazilian Synchrotron Light Laboratory (LNLS). A first asymmetrically cut silicon crystal using the (333) reflection vertically expanded the monochromated beam from 1 mm to 20 mm allowing the imaging of the whole sample without movements. A symmetrically cut Si(333) second crystal was used as a Bragg analyzer. Images of biological samples including human tissue were recorded using a direct-conversion CCD detector resulting in enhancement of the contrast compared with absorption-contrast images.

Brazil↗

A versatile X-ray diffraction station at LNLS (Brazil).

Versatility was a major consideration in the project to provide an X-ray diffraction station at LNLS. At least two techniques are possible at the station: powder diffraction and multiple single-crystal diffraction. A two-crystal monochromator based on monolithic elastic translators, developed at LNLS, with sagittal focusing by the second crystal, allows 10 mrad of a >/=2 keV monochromatic beam to be used on the diffractometer. The station is equipped with a fast scintillation detector, imaging plates, a high-energy-resolution pin-diode detector, an ionization chamber and a high-angular-resolution soller slit. The data collection and control hardware and software were also developed at LNLS. The theta-2theta goniometry for powder diffraction on this 1 m-diameter diffractometer is based on commercial rotation tables. The multiple single-crystal goniometry is realized by an independent elastic axis driven by differential micrometers for both high- and low-resolution angular movements. At least four independent axes can be positioned as necessary on the diffractometer table. Powder diffractograms and double-crystal rocking curves collected with the synchrotron beam show the expected quality.

Journal Article↗