Deep hypothermic arrest and left thoracotomy for repair of difficult thoracic aneurysms.

Seven patients with complex thoracic aortic aneurysms were operated on using profound hypothermia and circulatory arrest through a left thoracotomy. Three patients had false aneurysms, 2 had large aneurysms precluding access for proximal control, 1 patient had had previous hemiarch replacement, and 1 patient had a thoracoabdominal aneurysm. All patients were cooled on partial cardiopulmonary bypass until the electroencephalogram was isoelectric (approximately 15 degrees C rectal temperature). Circulatory arrest times ranged from 7 to 56 minutes (median, 34 minutes). There was one death due to cardiac failure, and paraplegia developed in 1 patient. The 6 survivors are otherwise well at a median of 12 months postoperatively. Hypothermia and circulatory arrest is an invaluable technique for the treatment of complex aortic aneurysms requiring left thoracotomy for resection. The techniques employed are described and the indications for their use are discussed.

Adult↗

Tricuspid atresia with dextrotransposition, dextrocardia, and mitral insufficiency: successful circulatory correction.

A 13-year-old patient with visceral and atrial situs solitus, dextrocardia, dextro (D) transposition of the great vessels with subaortic conus, tricuspid atresia, massive mitral valve insufficiency, and previously performed pulmonary artery banding was seen at our hospital. A right atrial to pulmonary artery conduit procedure and mitral valve replacement successfully repaired this child's circulation.

Adolescent↗

Pericardial fluid gas analysis in hemorrhagic pericardial tamponade.

Nine patients with hemorrhagic pericardial tamponade were studied to determine the localizing value of gas analysis of pericardial fluid in therapeutic pericardiocentesis. The aspirate and the central venous blood was analyzed simultaneously for partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), and hematocrit at the time of pericardiocentesis. In all 9 patients the difference in hematocrit between the pericardial fluid and the central venous blood was not significant. The PCO2 of pericardial fluid was significantly higher than that of central venous blood (p less than 0.025). The PO2 of pericardial fluid was consistently and significantly lower than that of central venous blood (p less than 0.005). We conclude that in patients with hemorrhagic pericardial tamponade, the simultaneous measurement of PO2 and PCO2 of central venous blood and pericardial fluid is a useful rapid bedside method to confirm the site of aspiration during pericardiocentesis. The PO2 determination is statistically the best discriminator between the two fluids in this setting.

Adolescent↗

Prophylactic use of intra-aortic ballon pump in aortocoronary bypass for patients with left main coronary artery disease.

Aortocoronary bypass surgery in patients with left main coronary artery disease is reported to have an operative mortality of between 1.4 and 39%. It is generally accepted that the operative mortality in this group of patients is considerably greater than in routine bypass candidates, presumably due to the large amount of myocardium threatened by a single lesion. In an effort to preserve threatened left ventricular myocardium, intra-aortic balloon pumping was instituted prophylactically prior to sternotomy in 20 consecutive patients with left main coronary artery disease (luminal narrowing greater than 50%). Sixty per cent of these patients had New York Heart Association Class IV angina, 25% had Class III, and 15% Class II. Fifty per cent of the patients in this group presented with unstable angina. Operative patients requiring left ventricular aneurysmectomy and/or valve replacement, were excluded. No operative deaths have been encountered in 20 consecutive patients managed in this manner. One patient displayed signs of myocardial infarction in the postoperative period. Correctable peripheral vascular ischemic complications of pump insertion were encountered in three patients. Preliminary results from this ongoing study support the hypothesis that prophylactic intra-aortic balloon pumping is a low risk procedure that should be utilized routinely in aortocoronary bypass surgery for left main coronary artery disease.

Assisted Circulation↗